VIRTUAL REALITY IN NEUROSURGICAL EDUCATION: PART-TASK VENTRICULOSTOMY SIMULATION WITH DYNAMIC VISUAL AND HAPTIC FEEDBACK
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Mastery of the neurosurgical skill set involves many hours of supervised intraoperative training. Convergence of political, economic, and social forces has limited neurosurgical resident operative exposure. There is need to develop realistic neurosurgical simulations that reproduce the operative experience, unrestricted by time and patient safety constraints. Computer-based, virtual reality platforms offer just such a possibility. The combination of virtual reality with dynamic, three-dimensional stereoscopic visualization, and haptic feedback technologies makes realistic procedural simulation possible. Most neurosurgical procedures can be conceptualized and segmented into critical task components, which can be simulated independently or in conjunction with other modules to recreate the experience of a complex neurosurgical procedure. METHODS: We use the ImmersiveTouch (ImmersiveTouch, Inc., Chicago, IL) virtual reality platform, developed at the University of Illinois at Chicago, to simulate the task of ventriculostomy catheter placement as a proof-of-concept. Computed tomographic data are used to create a virtual anatomic volume. RESULTS: Haptic feedback offers simulated resistance and relaxation with passage of a virtual three-dimensional ventriculostomy catheter through the brain parenchyma into the ventricle. A dynamic three-dimensional graphical interface renders changing visual perspective as the user's head moves. The simulation platform was found to have realistic visual, tactile, and handling characteristics, as assessed by neurosurgical faculty, residents, and medical students. CONCLUSION: We have developed a realistic, haptics-based virtual reality simulator for neurosurgical education. Our first module recreates a critical component of the ventriculostomy placement task. This approach to task simulation can be assembled in a modular manner to reproduce entire neurosurgical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rheingold, H. (1991) · Cited by 1,867
Guidelines for the Management of Severe Head Injury: What we Know and What we Think we Know
Chesnut, R. M. (1997) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199705001-00004 · Cited by 798
Guidelines for the management of severe head injury
BULLOCK, R., CHESNUT, R. M., CLIFTON, G., GHAJAR, J., MARION, D. W., NARAYAN, R. K., NEWELL, D. W., PITTS, L. H., ROSNER, M. J., & WILBERGER, J. W. (1996) · European Journal of Emergency Medicine · doi:10.1097/00063110-199606000-00010 · Cited by 684
Narayan, R. K., Kishore, P. R. S., Becker, D. P., Ward, J. D., Enas, G. G., Greenberg, R. P., Da Silva, A. D., Lipper, M. H., Choi, S. C., Mayhall, C. G., et al. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.56.5.0650 · Cited by 591 · cited 1×
“Optimal catheter trajectory and positioning are critical to prevent damage to vital neural and vascular structures (7, 10, 29, 31, 34).”
Background(1980) · Springer eBooks · doi:10.1007/978-3-642-67543-0 · Cited by 553
Korndorffer, J. R., Dunne, J. B., Sierra, R., Stefanidis, D., Touchard, C. L., & Scott, D. J. (2005) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2005.02.021 · Cited by 420 · cited 2×
“The system is limited by lower visual acuity (20/112), which would not provide adequate visualization of finer detail (e.g., catheter depth markings) for our ventriculostomy model.”
BackgroundBland, K. I. (2006) · Yearbook of Surgery · doi:10.1016/s0090-3671(08)70537-8 · Cited by 367
Planning and Simulation of Neurosurgery in a Virtual Reality Environment
Kockro, R. A., Serra, L., Tseng-Tsai, Y., Chan, C., Yih-Yian, S., Guan, C. G., Lee, E., Hoe, L. Y., Hern, N., & Nowinski, W. L. (2000) · Neurosurgery · doi:10.1093/neurosurgery/46.1.118 · Cited by 229 · cited 1×
“Often, these simulations can import patient-specific data and act as a form of “operative rehearsal” (4, 19, 38, 41).”
BackgroundStandard setting in medical education
Cusimano, M. D. (1996) · Academic Medicine · doi:10.1097/00001888-199610000-00062 · Cited by 175
Virtual Endoscopy for Planning and Simulation of Minimally Invasive Neurosurgery
Auer, L. M., Auer, L. M., & Auer, D. P. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00072 · Cited by 96 · cited 1×
“Often, these simulations can import patient-specific data and act as a form of “operative rehearsal” (4, 19, 38, 41).”
Background
Cited by
Immersive virtual reality as a teaching tool for neuroanatomy
Stepan, K., Zeiger, J., Hanchuk, S., Del Signore, A., Shrivastava, R., Govindaraj, S., & Iloreta, A. (2017) · International Forum of Allergy & Rhinology · doi:10.1002/alr.21986 · Cited by 402
Jang, S., Vitale, J. M., Jyung, R. W., & Black, J. B. (2017) · Computers & Education · doi:10.1016/j.compedu.2016.12.009 · Cited by 320
Virtual Reality and Simulation in Neurosurgical Training
Bernardo, A. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.06.140 · Cited by 314
Tang, Y. M., Chau, K. Y., Kwok, A. P. K., Zhu, T., & Ma, X. (2022) · Educational Research Review · doi:10.1016/j.edurev.2021.100429 · Cited by 281
Virtual Reality and Augmented Reality in Plastic Surgery: A Review
Kim, Y., Kim, H., & Kim, Y. O. (2017) · Archives of Plastic Surgery · doi:10.5999/aps.2017.44.3.179 · Cited by 267
3D printing for preoperative planning and surgical training: a review
Ganguli, A., Pagan-Diaz, G. J., Grant, L., Cvetkovic, C., Bramlet, M., Vozenilek, J., Kesavadas, T., & Bashir, R. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0301-9 · Cited by 248
“Recent advances in virtual surgical simulation for the brain using MRI imaging data and haptic devices have improved surgical outcomes by allowing surgeons to simulate the exact surgery on a computer and finalize the optimal approach (Lemole et al. 2007).”
BackgroundCyber sickness in low-immersive, semi-immersive, and fully immersive virtual reality
Martirosov, S., Bureš, M., & Zítka, T. (2022) · Virtual Reality · doi:10.1007/s10055-021-00507-4 · Cited by 235
“VR is widely used in medical area, where people train for various situations that they might face in real life (Lemole et al. 2007).”
BackgroundMashiko, T., Otani, K., Kawano, R., Konno, T., Kaneko, N., Ito, Y., & Watanabe, E. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2013.10.032 · Cited by 228
A novel three‐dimensional tool for teaching human neuroanatomy
Estevez, M. E., Lindgren, K. A., & Bergethon, P. R. (2010) · Anatomical Sciences Education · doi:10.1002/ase.186 · Cited by 213
“For example, neurosurgeons have developed advanced stereoscopic (Shimizu et al., 2006; Nowinski et al., 2009) and holographic (Ko and Webster, 1995) imaging applications as well as virtual reality (Kockro et al., 2007; Lemole et al., 2007) and stereolithic biomodeling (Wurm et al., 2004) techniques”
BackgroundNeuroTouch: A Physics-Based Virtual Simulator for Cranial Microneurosurgery Training
Delorme, S., Laroche, D., DiRaddo, R., & F. Del Maestro, R. (2012) · Operative Neurosurgery · doi:10.1227/neu.0b013e318249c744 · Cited by 206
Virtual reality training in neurosurgery: Review of current status and future applications
Alaraj, A., Lemole, M., Finkle, J., Yudkowsky, R., Wallace, A., Luciano, C., Banerjee, P., Rizzi, S., & Charbel, F. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.80117 · Cited by 204
Self-citationVirtual Reality in Neurosurgery: Beyond Neurosurgical Planning
Mishra, R., Narayanan, M. D. K., Umana, G. E., Montemurro, N., Chaurasia, B., & Deora, H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19031719 · Cited by 194
“, ventriculostomy catheter insertion models and subpial resection models), procedure simulation (NeuroTouch), surgical rehearsal platform (Dextroscope, virtual endoscopy), and robotic neurosurgery paradigms [8,20,35,84].”
MethodVirtual Reality Cerebral Aneurysm Clipping Simulation With Real-Time Haptic Feedback
Alaraj, A., Luciano, C. J., Bailey, D. P., Elsenousi, A., Roitberg, B. Z., Bernardo, A., Banerjee, P. P., & Charbel, F. T. (2015) · Operative Neurosurgery · doi:10.1227/neu.0000000000000583 · Cited by 185
Self-citationMalone, H. R., Syed, O. N., Downes, M. S., D'Ambrosio, A. L., Quest, D. O., & Kaiser, M. G. (2010) · Neurosurgery · doi:10.1227/neu.0b013e3181ee46d0 · Cited by 171
Virtual and stereoscopic anatomy: when virtual reality meets medical education
de Faria, J. W. V., Teixeira, M. J., de Moura Sousa Júnior, L., Otoch, J. P., & Figueiredo, E. G. (2016) · Journal of Neurosurgery · doi:10.3171/2015.8.jns141563 · Cited by 169
LeBlanc, J., Hutchison, C., Hu, Y., & Donnon, T. (2013) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.01284 · Cited by 66
Simulation in neurosurgery—a brief review and commentary
Cobb, M. I.-P. H., Taekman, J. M., Zomorodi, A. R., Gonzalez, L. F., & Turner, D. A. (2016) · World Neurosurgery · doi:10.1016/j.wneu.2015.11.068 · Cited by 46
Metadata
- Authors
- Lemole, G. M., Banerjee, P. P., Luciano, C., Neckrysh, S., & Charbel, F. T.
- Venue
- Neurosurgery
- Published
- 2007-07
- Volume
- 61
- Issue
- 1
- Pages
- 142-149
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2059205775
- Cited by
- 205
- References
- 21
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.