Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Robot-assisted stereoelectroencephalography (SEEG) may represent a simplified, precise, and safe alternative to the more traditional SEEG techniques. OBJECTIVE: To report our clinical experience with robotic SEEG implantation and to define its utility in the management of patients with medically refractory epilepsy. METHODS: The prospective observational analyses included all patients with medically refractory focal epilepsy who underwent robot-assisted stereotactic placement of depth electrodes for extraoperative brain monitoring between November 2009 and May 2013. Technical nuances of the robotic implantation technique are presented, as well as an analysis of demographics, time of planning and procedure, seizure outcome, in vivo accuracy, and procedure-related complications. RESULTS: One hundred patients underwent 101 robot-assisted SEEG procedures. Their mean age was 33.2 years. In total, 1245 depth electrodes were implanted. On average, 12.5 electrodes were implanted per patient. The time of implantation planning was 30 minutes on average (range, 15-60 minutes). The average operative time was 130 minutes (range, 45-160 minutes). In vivo accuracy (calculated in 500 trajectories) demonstrated a median entry point error of 1.2 mm (interquartile range, 0.78-1.83 mm) and a median target point error of 1.7 mm (interquartile range, 1.20-2.30 mm). Of the group of patients who underwent resective surgery (68 patients), 45 (66.2%) gained seizure freedom status. Mean follow-up was 18 months. The total complication rate was 4%. CONCLUSION: The robotic SEEG technique and method were demonstrated to be safe, accurate, and efficient in anatomically defining the epileptogenic zone and subsequently promoting sustained seizure freedom status in patients with difficult-to-localize seizures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery
Kwoh, Y. S., Hou, J., Jonckheere, E. A., & Hayati, S. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1354 · Cited by 1,278
Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
PATEL, V. R., TULLY, A. S., HOLMES, R., & LINDSAY, J. (2005) · Journal of Urology · doi:10.1097/01.ju.0000162082.12962.40 · Cited by 447
Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181d323ab · Cited by 407
Surgical outcome and prognostic factors of frontal lobe epilepsy surgery
Jeha, L. E., Najm, I., Bingaman, W., Dinner, D., Widdess-Walsh, P., & Luders, H. (2007) · Brain · doi:10.1093/brain/awl364 · Cited by 402
Self-citationThe cingulate gyrus and human behaviour
Talairach, J., Bancaud, J., Geier, S., Bordas-Ferrer, M., Bonis, A., Szikla, G., & Rusu, M. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90149-1 · Cited by 382
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.706 · Cited by 332
Engel, J., Henry, T. R., Risinger, M. W., Mazziotta, J. C., Sutherling, W. W., Levesque, M. F., & Phelps, M. E. (1990) · Neurology · doi:10.1212/wnl.40.11.1670 · Cited by 316
Neural networks involving the medial temporal structures in temporal lobe epilepsy
Bartolomei, F., Wendling, F., Bellanger, J.-J., Régis, J., & Chauvel, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00591-0 · Cited by 276
Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method
Guenot, M., Isnard, J., Ryvlin, P., Fischer, C., Ostrowsky, K., Mauguiere, F., & Sindou, M. (2001) · Stereotactic and Functional Neurosurgery · doi:10.1159/000064595 · Cited by 232
In Touch with Robotics: Neurosurgery for the Future
Nathoo, N., Çavuşoğlu, M. C., Vogelbaum, M. A., & Barnett, G. H. (2005) · Neurosurgery · doi:10.1227/01.neu.0000153929.68024.cf · Cited by 221
Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note
Gonzalez-Martinez, J., Mullin, J., Vadera, S., Bulacio, J., Hughes, G., Jones, S., Enatsu, R., & Najm, I. (2014) · Journal of Neurosurgery · doi:10.3171/2013.11.jns13635 · Cited by 209
Self-citationWendling, F., Bartolomei, F., Bellanger, J. J., & Chauvel, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00547-8 · Cited by 204
Lesion, "Irritative" Zone and Epileptogenic Focus
Talairach, J., & Bancaud, J. (1966) · Stereotactic and Functional Neurosurgery · doi:10.1159/000103937 · Cited by 200
Tassi, L. (2004) · Brain · doi:10.1093/brain/awh357 · Cited by 200
Close to you? Bias and precision in patent-based measures of technological proximity
Benner, M., & Waldfogel, J. (2008) · Research Policy · doi:10.1016/j.respol.2008.05.011 · Cited by 185
Fear as the main feature of epileptic seizures
Biraben, A. (2001) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.70.2.186 · Cited by 183
Functional stereotaxic exploration (SEEG) of epilepsy.
Bancaud, J., Angelergues, R., Bernouilli, C., Bonis, A., Bordas-Ferrer, M., Bresson, M., Buser, P., Covello, L., Morel, P., Szikla, G., et al. (1970) · PubMed · Cited by 176
Battaglia, G., Chiapparini, L., Franceschetti, S., Freri, E., Tassi, L., Bassanini, S., Villani, F., Spreafico, R., D'Incerti, L., & Granata, T. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00374.x · Cited by 173
Use of the NeuroMate stereotactic robot in a frameless mode for functional neurosurgery
Varma, T. R. K., & Eldridge, P. R. (2006) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.88 · Cited by 165
Subdural electrode analysis in focal cortical dysplasia: Predictors of surgical outcome
Widdess-Walsh, P., Jeha, L., Nair, D., Kotagal, P., Bingaman, W., & Najm, I. (2007) · Neurology · doi:10.1212/01.wnl.0000267427.91987.21 · Cited by 160
Self-citationFrontal Lobe Seizures: Electroclinical Syndromes
Salanova, V., Morris, H. H., Ness, P. V., Kotagal, P., Wyllie, E., & Lüders, H. O. (1995) · Epilepsia · doi:10.1111/j.1528-1157.1995.tb01659.x · Cited by 156
Epilepsy Surgery in Children: Results and Predictors of Outcome on Seizures
Cossu, M., Russo, G. L., Francione, S., Mai, R., Nobili, L., Sartori, I., Tassi, L., Citterio, A., Colombo, N., Bramerio, M., et al. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01207.x · Cited by 153
Chronic subdural electrodes in the management of epilepsy
Nair, D. R., Burgess, R. C., McIntyre, C. C., & Lüders, H. O. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.117 · Cited by 147
Computer-Driven Robot for Stereotactic Surgery Connected to CT Scan and Magnetic Resonance Imaging
Benabid, A., Cinquin, P., Lavalle, S., Bas, J. F. L., Jacques Demongeot, A., & Rougemont, J. (1987) · Stereotactic and Functional Neurosurgery · doi:10.1159/000100701 · Cited by 140
McBeth, P. B., Louw, D. F., Rizun, P., & Sutherland, G. R. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.004 · Cited by 121
Woerdeman, P. A., Willems, P. W. A., Noordmans, H. J., Tulleken, C. A. F., & van der Sprenkel, J. W. B. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.6.1012 · Cited by 119
SEEG-guided thermocoagulations
Catenoix, H., Mauguı̀ere, F., Guénot, M., Ryvlin, P., Bissery, A., Sindou, M., & Isnard, J. (2008) · Neurology · doi:10.1212/01.wnl.0000335166.20451.88 · Cited by 113
La Stereo-Electroencephalographie dans l' Epilepsie.
Charlton, M. H. (1965) · Archives of Neurology · doi:10.1001/archneur.1965.00470030113016 · Cited by 112
Robotics in the neurosurgical treatment of glioma
Sutherland, G. R., Maddahi, Y., Gan, L. S., Lama, S., & Zareinia, K. (2015) · Surgical Neurology International · doi:10.4103/2152-7806.151321 · Cited by 88
Application of Stereotactic Concepts to the Surgery of Epilepsy
Talairach, J., & Szikla, G. (1980) · Acta neurochirurgica. Supplementum · doi:10.1007/978-3-7091-8592-6_5 · Cited by 86
Cossu, M., Cardinale, F., Castana, L., Nobili, L., Sartori, I., & Russo, G. L. (2006) · Child s Nervous System · doi:10.1007/s00381-006-0127-2 · Cited by 81
Distance Geometry : Theory, Methods, and Applications
Mucherino, A., Lavor, C., Liberti, L., & Maculan, N. (2013) · HAL · doi:10.1007/978-1-4614-5128-0 · Cited by 74
Subdural Monitoring in the Evaluation of Children for Epilepsy Surgery
Jayakar, P. A., DUCHOWNY, M. S., & Resnick, T. (1994) · Journal of Child Neurology · doi:10.1177/0883073894009002091 · Cited by 74
[Clinical value of electromyographic studies of the ocular muscles].
Bancaud, J., & Talairach, J. (1973) · PubMed · Cited by 67
Motulsky, H. J., & Neubig, R. R. (2010) · Current Protocols in Neuroscience · doi:10.1002/0471142301.ns0705s52 · Cited by 62
Guénot, M., & Isnard, J. (2008) · Neurochirurgie · doi:10.1016/j.neuchi.2008.02.010 · Cited by 49
Bancaud, J., & Mb, D. (1959) · PubMed · Cited by 47
Najm, I., Bingaman, W. E., & Lüders, H. O. (2002) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(02)80009-2 · Cited by 46
Self-citationCossu, M., Chabardès, S., Hoffmann, D., & Russo, G. L. (2008) · Neurochirurgie · doi:10.1016/j.neuchi.2008.02.031 · Cited by 45
Musolino, A., Tournoux, P., Missir, O., & Talairach, J. (1990) · PubMed · Cited by 44
Robotic Neurological Surgery Applications: Accuracy and Consistency or Pure Fantasy?
Eljamel, S. (2009) · Stereotactic and Functional Neurosurgery · doi:10.1159/000202974 · Cited by 38
[Functional stereotaxic investigations in epilepsy. Methodological remarks concerning a case].
Talairach, J., Bancaud, J., Bonis, A., Tournoux, P., Szikla, G., & Morel, P. (1961) · PubMed · Cited by 32
Bancaud, J., Favel, P., Bonis, A., Bordas-Ferrer, M., Miravet, J., & Talairach, J. (1970) · PubMed · Cited by 32
La thermocoagulation multiple de foyers épileptogènes guidée par la SEEG (thermo-SEEG)
Guénot, M., & Isnard, J. (2008) · Neurochirurgie · doi:10.1016/j.neuchi.2008.02.012 · Cited by 27
A propos du repérage stéréotaxique des noyaux gris centraux
Talairach, J., & Tournoux, P. (1958) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-0028-1095515 · Cited by 24
Nathoo, N., Pesek, T. J., & Barnett, G. H. (2003) · Surgical Clinics of North America · doi:10.1016/s0039-6109(03)00157-9 · Cited by 22
[Introduction to the clinical study of postrolandic epileptic seizures].
Baucaud, J., Talairach, J., Munari, C., et al. (1991) · PubMed · Cited by 18
Robotics in neurosurgery: which tools for what?
Benabid, A., Hoffmann, D., Seigneuret, É., & Chabardès, S. (2007) · Springer eBooks · doi:10.1007/978-3-211-33303-7_7 · Cited by 11
Stereotaxic Accuracy in Vivo of Talairach Method in Temporal Lobes
Crandall, P. H., Brown, W. J., & Brinza, K. C. (2007) · Confinia Neurologica · doi:10.1159/000103946 · Cited by 8
Cited by
Stereoelectroencephalography: retrospective analysis of 742 procedures in a single centre
Cardinale, F., Rizzi, M., Vignati, E., Cossu, M., Castana, L., d’Orio, P., Revay, M., Costanza, M. D., Tassi, L., Mai, R., et al. (2019) · Brain · doi:10.1093/brain/awz196 · Cited by 208
Tandon, N., Tong, B. A., Friedman, E. R., Johnson, J. A., Von Allmen, G., Thomas, M. S., Hope, O. A., Kalamangalam, G. P., Slater, J. D., & Thompson, S. A. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.0098 · Cited by 191
Self-citationRobot-assisted procedures in pediatric neurosurgery
De Benedictis, A., Trezza, A., Carai, A., Genovese, E., Procaccini, E., Messina, R., Randi, F., Cossu, S., Esposito, G., Palma, P., et al. (2017) · Neurosurgical Focus · doi:10.3171/2017.2.focus16579 · Cited by 178
A lexical semantic hub for heteromodal naming in middle fusiform gyrus
Forseth, K. J., Kadipasaoglu, C. M., Conner, C. R., Hickok, G., Knight, R. T., & Tandon, N. (2018) · Brain · doi:10.1093/brain/awy120 · Cited by 161
Deep Brain Stimulation for Depression Informed by Intracranial Recordings
Sheth, S. A., Bijanki, K. R., Metzger, B., Allawala, A., Pirtle, V., Adkinson, J. A., Myers, J., Mathura, R. K., Oswalt, D., Tsolaki, E., et al. (2022) · Biological Psychiatry · doi:10.1016/j.biopsych.2021.11.007 · Cited by 158
“Our trial utilizes stereo-EEG (sEEG), a percutaneous method for placing recording electrodes within the brain and interpreting network-wide activity (13).”
Metadata
- Authors
- González-Martínez, J., Bulacio, J., Thompson, S., Gale, J., Smithason, S., Najm, I., & Bingaman, W.
- Venue
- Neurosurgery
- Published
- 2016-02
- Volume
- 78
- Issue
- 2
- Pages
- 169-180
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2442656190
- Cited by
- 315
- References
- 50
- FWCI
- 17.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.