The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Surface morphology and mechanical properties of MDCK monolayers by atomic force microscopy
Abstract
We describe the morphology and mechanical stability of the apical surface of MDCK monolayers by atomic force microscopy (AFM). Living cells could be imaged in physiological solution for several hours without noticeable deterioration. Cell boundaries appear as ridges that clearly demarcate neighboring cells. In some cases the nucleus of individual cells could be seen, though apparently only in very thin areas of the monolayer. Two types of protrusions on the surface could be visualized. Smooth bulges that varied in width from a few hundred nanometers to several micrometers, which appear to represent relatively rigid subapical structures. Another type of protrusion extended well above the membrane and was swept back and forth during the imaging. However, the microvilli that are typically present on the apical surface could not be resolved. For comparison, a transformed MDCK cell line expressing the K-rasoncogene was also examined. When cultured on solid substrata at low density, the R5 cells spread out and are less than 100 nm thick over large areas with both extensive processes and rounded edges. Many intracellular structures such as the nucleus, cytoskeletal elements and vesicles could be visualized. None of the intracellular structures seen in the AFM images could be seen by scanning electron microscopy. Both R5 cells and MDCK monolayers required imaging forces of >2 nN for good image contrast. Force measurements on the MDCK monolayers show that they are very soft, with an effective spring constant of ∼0.002 N/m for the apical plasma membrane, over the first micrometer of deformation, resulting in a height deformation of approximately 500 nm per nanoNewton of applied force. The mechanical properties of the cells could be manipulated by addition of glutaraldehyde. These changes were monitored in real time by collecting force curves during the fixation reaction. The curves show a stiffening of the apical plasma membrane that was completed in ∼1 minute. On the basis of these measurements and the imaging forces required, we conclude that deformation of the plasma membrane is an important component of the contrast mechanism, in effect ‘staining’ structures based on their relative rigidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Dystrophin protects the sarcolemma from stresses developed during muscle contraction
Petrof, B. J., Shrager, J. B., Stedman, H. H., Kelly, A. M., & Sweeney, H. L. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3710 · Cited by 1,526
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Cell Surface Polarity in Epithelia
Simons, K., & Fuller, S. D. (1985) · Annual Review of Cell Biology · doi:10.1146/annurev.cb.01.110185.001331 · Cited by 876
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Charles, A. C., Merrill, J. E., Dirksen, E. R., & Sandersont, M. J. (1991) · Neuron · doi:10.1016/0896-6273(91)90238-u · Cited by 736
Burnham, N. A., & Colton, R. J. (1989) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576168 · Cited by 651
Forces in atomic force microscopy in air and water
Weisenhorn, A. L., Hansma, P. K., Albrecht, T. R., & Quate, C. F. (1989) · Applied Physics Letters · doi:10.1063/1.101024 · Cited by 632
Matlin, K. S., & Simons, K. (1983) · Cell · doi:10.1016/0092-8674(83)90154-x · Cited by 508
Deformation and height anomaly of soft surfaces studied with an AFM
Weisenhorn, A. L., Khorsandi, M., Kasas, S., Gotzos, V, & Butt, H. J. (1993) · Nanotechnology · doi:10.1088/0957-4484/4/2/006 · Cited by 427
Actin Filament Dynamics in Living Glial Cells Imaged by Atomic Force Microscopy
Henderson, E., Haydon, P. G., & Sakaguchi, D. S. (1992) · Science · doi:10.1126/science.1411511 · Cited by 415
Decreased osmotic stability of dystrophin-less muscle cells from the mdx mouse
Menke, A., & Jockusch, H. (1991) · Nature · doi:10.1038/349069a0 · Cited by 331
Imaging cells with the atomic force microscope
Butt, H.-J., Wolff, E. K., Gould, S. A. C., Dixon Northern, B., Peterson, C. M., & Hansma, P. K. (1990) · Journal of Structural Biology · doi:10.1016/1047-8477(90)90098-w · Cited by 266
Quantized adhesion detected with the atomic force microscope
Hoh, J. H., Cleveland, J. P., Prater, C. B., Revel, J. P., & Hansma, P. K. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00038a075 · Cited by 252
Self-citationBiological Applications of Scanning Probe Microscopes
Engel, A. (1991) · Annual Review of Biophysics and Biophysical Chemistry · doi:10.1146/annurev.bb.20.060191.000455 · Cited by 199
Structure of the extracellular surface of the gap junction by atomic force microscopy
Hoh, J. H., Sosinsky, G. E., Revel, J. P., & Hansma, P. K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81074-9 · Cited by 172
Self-citationAFM images of dissolution and growth on a calcite crystal
Hillner, P. E., Manne, S., Gratz, A. J., & Hansma, P. K. (1992) · Ultramicroscopy · doi:10.1016/0304-3991(92)90454-r · Cited by 167
Three-dimensional imaging of living neurons and glia with the atomic force microscope
Parpura, V., Haydon, P. G., & Henderson, E. R. (1993) · Journal of Cell Science · doi:10.1242/jcs.104.2.427 · Cited by 144
Multilayering and loss of apical polarity in MDCK cells transformed with viral K-ras.
Schoenenberger, C., Żuk, A., Kendall, D., & Matlin, K. S. (1991) · The Journal of Cell Biology · doi:10.1083/jcb.112.5.873 · Cited by 99
Self-citationCellular and molecular adaptations to injurious mechanical stress
McNeil, P. L. (1993) · Trends in Cell Biology · doi:10.1016/0962-8924(93)90012-p · Cited by 86
Investigation of living cells in the nanometer regime with the scanning force microscope.
Hörber, J. K., Häberle, W., Ohnesorge, F. M., Binnig, G. K., Liebich, H., Czerny, C., Mahnel, H., & Mayr, A. (1992) · PubMed · Cited by 68
Cytoskeleton of living, unstained cells imaged by scanning force microscopy
Chang, L., Kious, T., Yorgancioglu, M., Keller, D., & Pfeiffer, J. R. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81493-0 · Cited by 59
Cell polarity and epithelial oncogenesis
Schoenenberger, C., & Matlin, K. S. (1991) · Trends in Cell Biology · doi:10.1016/0962-8924(91)90035-8 · Cited by 46
Self-citation
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Rotsch, C., & Radmacher, M. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76614-8 · Cited by 971
Imaging modes of atomic force microscopy for application in molecular and cell biology
Dufrêne, Y. F., Ando, T., Garcia, R., Alsteens, D., Martinez-Martin, D., Engel, A., Gerber, C., & Müller, D. J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.45 · Cited by 945
Measuring the viscoelastic properties of human platelets with the atomic force microscope
Radmacher, M., Fritz, M., Kacher, C. M., Cleveland, J. P., & Hansma, P. K. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79602-9 · Cited by 839
Atomic force microscopy-based mechanobiology
Krieg, M., Fläschner, G., Alsteens, D., Gaub, B. M., Roos, W. H., Wuite, G. J. L., Gaub, H. E., Gerber, C., Dufrêne, Y. F., & Müller, D. J. (2018) · Nature Reviews Physics · doi:10.1038/s42254-018-0001-7 · Cited by 799
Metadata
- Authors
- Hoh, J. H., & Schoenenberger, C.-A.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 1994-05-01
- Volume
- 107
- Issue
- 5
- Pages
- 1105-1114
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2169969818
- Cited by
- 418
- References
- 25
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.