CoChat

New joints for the Millennium: Wear control in total replacement hip joints

Dowson, D · 2001 · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Cited by 177

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Hip joint replacement is described as the greatest achievement in orthopaedic surgery in the twentieth century. The field has been dominated for some forty years by implants based upon metallic femoral heads and stems and polymeric acetabular cups. At the dawn of the new Millennium, many alternative materials and designs are now being proposed or evaluated. The reasons for these developments and the current contributions of engineering science and tribology to advances in hip replacement are discussed. Illustrations are presented of the significant changes being proposed or introduced. While the new designs of total hip replacements offer exciting engineering contributions to the future of joint replacement, the long-term benefits to patients will depend upon the biological response to the new devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1243/0954411011535939

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 86

  1. Dowson D. Bio-tribology. Plenary Lecture In Proceedings of the International Conference on New Frontiers in Biomechanical Engineering (Eds Tanishita K., Sato M.), July 1997, pp. 9–14 (The Japanese Society of Mechanical Engineers, Tokyo).
  2. 10.1302/0301-620X.48B2.245 · doi:10.1302/0301-620x.48b2.245
  3. Journal. Proc. Instn Mech. Engrs, 1967, 181 (3 J), 1–172.
  4. 10.1007/BF02474667 · doi:10.1007/bf02474667
  5. 10.1243/0954411971534656 · doi:10.1243/0954411971534656
  6. 10.1097/00003086-197811000-00004 · doi:10.1097/00003086-197811000-00004
  7. 10.1016/0043-1648(85)90050-X · doi:10.1016/0043-1648(85)90050-x
  8. Murakami T., Ohtsuki N., Higaki H. The adaptive multimode lubrication in biotribological systems. In Proceedings of the International Tribology Conference, Yokohama, 1995, pp. 1–6 (Japanese Society of Mechanical Engineers).
  9. 10.1243/0954406001522822 · DOI
  10. 10.1115/1.3452608 · doi:10.1115/1.3452608
  11. O'Kelly J., Unsworth A., Dowson D., Jobbins B., Wright V. Pendulum and simulator for studies of friction in hip joints In Evaluation of Artificial Joints (Eds Dowson D., Wright V.), 1977, Ch. 2, pp. 19–29 (The Biological Engineering Society).
  12. 10.1243/EMED_JOUR_1988_017_029_02 · doi:10.1243/emed_jour_1988_017_029_02
  13. 10.1016/0043-1648(94)90179-1 · doi:10.1016/0043-1648(94)90179-1
  14. Unsworth A. Hall R. M. Burgess I. C. Wroblewski B. M. Streicher R. M. Semlitsch M. Frictional resistance of new and explanted artificial hip joints In Proceedings of the 4th International Tribology Conference Austrib ′94 Perth Western Australia 1994 pp. 383–390.
  15. 10.1016/0041-2678(73)90172-3 · doi:10.1016/0041-2678(73)90172-3
  16. 10.1016/0043-1648(93)90090-9 · doi:10.1016/0043-1648(93)90090-9
  17. 10.1016/0043-1648(85)90048-1 · doi:10.1016/0043-1648(85)90048-1
  18. 10.1302/0301-620X.32B2.166 · doi:10.1302/0301-620x.32b2.166
  19. 10.1097/00003086-197510000-00021 · doi:10.1097/00003086-197510000-00021
  20. 10.1302/0301-620X.54B1.61 · doi:10.1302/0301-620x.54b1.61
  21. 10.1302/0301-620X.78B1.0780082 · doi:10.1302/0301-620x.78b1.0780082
  22. 10.1097/00003086-199706000-00019 · doi:10.1097/00003086-199706000-00019
  23. 10.2106/00004623-199711000-00001 · doi:10.2106/00004623-199711000-00001
  24. 10.1016/S0883-5403(97)90169-8 · doi:10.1016/s0883-5403(97)90169-8
  25. 10.2106/00004623-199705000-00007 · doi:10.2106/00004623-199705000-00007
  26. 10.1302/0301-620X.67B5.4055876 · doi:10.1302/0301-620x.67b5.4055876
  27. 10.1243/PIME_PROC_1992_206_286_02 · doi:10.1243/pime_proc_1992_206_286_02
  28. 10.1097/00003086-199203000-00015 · doi:10.1097/00003086-199203000-00015
  29. 10.2106/00004623-199608000-00009 · doi:10.2106/00004623-199608000-00009
  30. 10.1016/1350-4533(94)90042-6 · doi:10.1016/1350-4533(94)90042-6
  31. Weber B. G. Total hip replacement: rotating versus fixed and metal versus ceramic heads. In Proceedings of the 9th Hip Society Meeting 1981 264–275.
  32. 10.3928/0147-7447-19960901-06 · doi:10.3928/0147-7447-19960901-06
  33. 10.1177/112070009900900310 · doi:10.1177/112070009900900310
  34. 10.1302/0301-620X.80B4.7361 · doi:10.1302/0301-620x.80b4.7361
  35. 10.1177/112070000001000104 · doi:10.1177/112070000001000104
  36. Dowson D., El-Hady Diab M. M., Gillis B. J., Atkinson J. R. Influence of counterface topography on the wear of ultra-high molecular weight polyethylene under wet or dry conditions In Polymer Wear and Its Control (Ed. Lieng-Huang Lee), ACS Symposium Series 287, Ch. 12, pp. 171–187 (American Chemical Society).
  37. Lancaster J. G., Dowson D., Fisher J. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current surfaces in joint replacement Proc. Instn Mech. Engrs, Part H, Journal of Engineering in Medicine, 1997, 211 (H3), 197–207.
  38. 10.1243/PIME_PROC_1996_210_413_02 · doi:10.1243/pime_proc_1996_210_413_02
  39. Dowson D., Taheri S., Wallbridge N. C. The role of counterface imperfections in the wear of polyethylene. In International Conference on Wear of Materials, Houston, Texas, 5-9 April 1987, pp. 415–425 (Elsevier, Amsterdam).
  40. 10.1243/PIME_PROC_1995_209_353_02 · doi:10.1243/pime_proc_1995_209_353_02
  41. 10.1016/S0043-1648(00)00370-7 · doi:10.1016/s0043-1648(00)00370-7
  42. McKellop H. A., Campbell P., Park Sang-Hyun, Schmalzried T. P., Grigoris P., Amstutz H. C., Sarmiento A. The origin of submicron polyethylene wear debris in total hip arthroplasty Clin. Orthop. Related Res., 1995, 311, 3–20.
  43. 10.1023/A:1018537001366 · doi:10.1023/a:1018537001366
  44. Boutin P. Arthroplastic totale de la hanche par prosthese en alumine fritte Rev. Chir. Orthop., 1972, 58, 229–246.
  45. 10.1002/jbm.820110409 · doi:10.1002/jbm.820110409
  46. 10.1243/0954411971534647 · doi:10.1243/0954411971534647
  47. 10.1016/0043-1648(96)80015-9 · doi:10.1016/0043-1648(96)80015-9
  48. 10.1243/0954411991534825 · doi:10.1243/0954411991534825
  49. McKellop H., Lu B. Friction lubrication and wear of polyethylene-metal and polyethylene-ceramic hip prostheses in a joint simulator. In Transactions of the Fourth World Biomaterials Congress, Berlin, 1992, p. 118 (The Program and Organising Committees of the Constituent Societies and the authors).
  50. 10.1243/0954411991535068 · doi:10.1243/0954411991535068
  51. McKee G. K. McKee-Farrar total prosthetic replacement of the hip In Total Hip Replacement (Ed. Jayson M.), 1971, pp. 47–67 (Sector Publishing, London).
  52. 10.1302/0301-620X.50B4.720 · doi:10.1302/0301-620x.50b4.720
  53. Ring P. A. Ring total hip replacement In Total Hip Replacement (Ed. Jayson M.), 1971, pp. 26–46 (Sector Publishing, London).
  54. 10.1302/0301-620X.68B4.3733823 · doi:10.1302/0301-620x.68b4.3733823
  55. 10.1097/00003086-199608001-00003 · doi:10.1097/00003086-199608001-00003
  56. 10.1097/00003086-199608001-00005 · doi:10.1097/00003086-199608001-00005
  57. Müller M. E. The benefits of metal-on-metal total hip replacements Clin. Orthop. Related Res., 1995, 311, 54–59.
  58. 10.1097/00003086-199612000-00009 · doi:10.1097/00003086-199612000-00009
  59. Scales J. T. Arthroplasty of the hip using foreign materials: A history Proc. Instn Mech. Engrs, 1967, 181 (3J), 63–84.
  60. McKee G. K. Developments in total hip replacement Proc. Instn Mech. Engrs, 1967, 181 (3J), 85–89.
  61. Duff-Barclay I., Scales J. T., Wilson J. N. The development of the Stanmore total hip replacement Proc. R. Soc. Medicine, 1966, 59 (10), 948–951.
  62. 10.1007/978-3-642-79306-6_4 · doi:10.1007/978-3-642-79306-6_4
  63. 10.1243/0954411971534359 · doi:10.1243/0954411971534359
  64. 10.1243/0954406001522822 · DOI
  65. Hulbert S. F. A history of alumina ceramics as implant materials In Bioceramics, Proceedings of 1st International Bioceramic Symposium (Eds Oonishi H., Aoki H., Sawai K.), Ishiyaku EuroAmerica, Tokyo, 1989, pp. 189–194.
  66. 10.1142/9789814317351_0002 · doi:10.1142/9789814317351_0002
  67. 10.1002/jbm.820221210 · doi:10.1002/jbm.820221210
  68. 10.1302/0301-620X.76B1.8300682 · doi:10.1302/0301-620x.76b1.8300682
  69. Miller J. A., Talton J. D., Bhatia S. Alumina-alumina and alumina-polyethylene total hip prostheses In Clinical Performance of Skeletal Prostheses (Eds Hench L. L., Wilson J.), 1996, Ch. 4, pp. 41–55 (Chapman and Hall, London).
  70. 10.1016/S0883-5403(96)80006-4 · doi:10.1016/s0883-5403(96)80006-4
  71. Mittelmeir H., Heisel J. Sixteen-years experience with ceramic hip prostheses Clin. Orthop., 1992, 282, 64–72.
  72. Wallbridge N. C., Dowson D., Roberts E. W. A study of the wear characteristics of sliding pairs of high density polycrystalline aluminium oxide with particular reference to their use in total replacement human joints Engng in Medicine, Instn Mech. Engrs, 1983, 12 (1), 23–28.
  73. Sliney H. E., Dellacorte C. The friction and wear of ceramic/ceramic and ceramic/metal combinations in sliding contact Lubric. Engng, Soc. Tribologists and Lubric. Engrs, 1994, 50 (7), 571–576.
  74. 10.3109/17453679808997776 · doi:10.3109/17453679808997776
  75. Firkins P. J. Tipper J. L. Ingham E. Stone M. H. Farrar R. Fisher J. A novel low wearing differential hardness ceramic on metal prosthesis. In British Orthopaedic Research Society Spring Meeting 2000. · doi:10.1016/s0021-9290(01)00096-3
  76. Dowson D. Are our joint replacement materials adequate? In Proceedings of IMechE International Conference on Changing Role of Engineering in Orthopaedics, 1989, pp. 1–5 (Mechanical Engineering Publications, London).
  77. 10.1016/0043-1648(76)90036-3 · doi:10.1016/0043-1648(76)90036-3
  78. Medley J. B., Pilliar R. M., Wong E. W., Strong A. B. Hydrophylic polyurethane elastomers for hemiarthroplasty: A preliminary in vitro study Engng in Medicine, Instn. Mech. Engrs, 1980, 9 (2), 59–65.
  79. Unsworth A. U., Pearcy M. J., White E. F.T., White G. Soft layer lubrication of artificial hip joints In Proceedings of IMechE International Conference on Fifty Years On, 1987, pp. 715–724 (Mechanical Engineering Publications, London).
  80. 10.1016/0141-5425(91)90123-O · doi:10.1016/0141-5425(91)90123-o
  81. 10.1007/BF00120132 · doi:10.1007/bf00120132
  82. 10.1243/PIME_PROC_1991_205_269_02 · doi:10.1243/pime_proc_1991_205_269_02
  83. Auger D. D., Dowson D., Fisher J. F. Cushion form bearings for total knee joint replacement. Part 1: Design, friction and lubrication Proc. Instn Mech. Engrs, Part H, Journal of Engineering in Medicine, 1995, 209 (H2), 72–81.
  84. 10.1243/PIME_PROC_1995_209_324_02 · doi:10.1243/pime_proc_1995_209_324_02
  85. 10.1016/S0021-9290(98)00034-7 · doi:10.1016/s0021-9290(98)00034-7
  86. 10.1243/PIME_PROC_1991_205_297_02 · doi:10.1243/pime_proc_1991_205_297_02

Cited by

See all 177

Metadata

Authors
Dowson, D.
Venue
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Published
2001-04
Volume
215
Issue
4
Pages
335-358
ISSN
  • 0954-4119 (ISSN-L)
  • 2041-3033
OpenAlex
W2065749233
Cited by
177
References
20
FWCI
4.97
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.