Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
Abstract
PURPOSE: The purpose of this study was to determine the accuracy and reliability of the following electronic pedometers for measuring steps: Freestyle Pacer Pro (FR), Kenz Lifecorder (KZ), New Lifestyles NL-2000 (NL), Omron HJ-105 (OM), Oregon Scientific PE316CA (OR), Sportline 330 (SL330) and 345 (SL345), Walk4Life LS 2525 (WL), Yamax Skeletone EM-180 (SK), and the Yamax Digi-Walker SW-701 (DW). METHODS: Ten males (34.7 +/- 12.6 yr) (mean +/- SD) and 10 females (43.1 +/- 19.9 yr) ranging in BMI from 19.8 to 33.6 kg.m-2 walked 400-m around an outdoor track while wearing two pedometers of the same model (one on the right and left sides of the body) for each of 10 models. Four pedometers of each model were assessed in this fashion. The actual steps taken were tallied by a researcher. RESULTS: The KZ, NL, and DW were the most accurate in counting steps, displaying values that were within +/-3% of the actual steps taken, 95% of the time. The SL330 and OM were the least accurate, displaying values that were within +/-37% of the actual steps, 95% of the time. The reliability within a single model (Cronbach's alpha) was >0.80 for all pedometers with the exception of the SL330. The intramodel reliability was exceptionally high (>0.99) in the KZ, OM, NL, and the DW. CONCLUSION: Due to the variation that exists among models in regard to the internal mechanism and sensitivity, not all pedometers count steps accurately. Thus, it is important for researchers who use pedometers to assess physical activity to be aware of their accuracy and reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PHYSICAL ACTIVITY AS AN INDEX OF HEART ATTACK RISK IN COLLEGE ALUMNI1
PAFFENBARGER, R. S., WING, A. L., & HYDE, R. T. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112608 · Cited by 1,980
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Self-citationTudor-Locke, C. E., & Myers, A. M. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608926 · Cited by 518
Objective Monitoring of Physical Activity Using Motion Sensors and Heart Rate
Freedson, P. S., & Miller, K. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082782 · Cited by 482
Comparison of pedometer and accelerometer measures of free-living physical activity
TUDOR-LOCKE, C., AINSWORTH, B. E., THOMPSON, R. W., & MATTHEWS, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 386
Comprehensive evaluation of the Minnesota leisure time physical activity questionnaire
Richardson, M. T., Leon, A. S., Jacobs, D. R., Ainsworth, B. E., & Serfass, R. (1994) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)90008-6 · Cited by 363
Yamanouchi, K., Shinozaki, T., Chikada, K., Nishikawa, T., Ito, K., Shimizu, S., Ozawa, N., Suzuki, Y., Maeno, H., Kato, K., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.775 · Cited by 330
Increasing daily walking lowers blood pressure in postmenopausal women
MOREAU, K. L., DEGARMO, R., LANGLEY, J., MCMAHON, C., HOWLEY, E. T., BASSETT, D. R., & THOMPSON, D. L. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00005 · Cited by 280
Self-citationMeasurement of daily walking distance-questionnaire versus pedometer
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200005000-00021 · Cited by 260
Self-citationSequeira, M. M., Rickenbach, M., Wietlisbach, V., Tullen, B., & Schutz, Y. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117748 · Cited by 250
IWANE, M., ARITA, M., TOMIMOTO, S., SATANI, O., MATSUMOTO, M., MIYASHITA, K., & NISHIO, I. (2000) · Hypertension Research · doi:10.1291/hypres.23.573 · Cited by 212
The relationship between pedometer-determined ambulatory activity and body composition variables
Tudor-Locke, C., Ainsworth, B., Whitt, M., Thompson, R., Addy, C., & Jones, D. (2001) · International Journal of Obesity · doi:10.1038/sj.ijo.0801783 · Cited by 202
Step activity monitor: Increased accuracy in quantifying ambulatory activity
Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170512 · Cited by 182
White, W. B., Lund-Johansen, P., & Omvik, P. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90026-w · Cited by 169
Cox, A. (1977) · The Lancet · doi:10.1016/s0140-6736(77)91841-4 · Cited by 158
A 10,000-Step Count as a Physical Activity Target for Sedentary Women
Wilde, B. E., Sidman, C. L., & Corbin, C. B. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608977 · Cited by 155
Pedometer-determined ambulatory activity in individuals with type 2 diabetes
Tudor-Locke, C. E., Bell, R. C., Myers, A. M., Harris, S. B., Lauzon, N., & Rodger, N. W. (2002) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(01)00317-5 · Cited by 108
Cited by
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
“Sixteen studies used the Yamax pedometer (Yamax Corp, Tokyo, Japan)—a model that has been well validated for accuracy and reliability and is frequently used in physical activity research.(41-44) The physical activity interventions evaluated in the included studies varied considerably: mean (SD) duration was 18 (24) we…”
MethodConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
How many steps/day are enough? for adults
Tudor-Locke, C., Craig, C. L., Brown, W. J., Clemes, S. A., De Cocker, K., Giles-Corti, B., Hatano, Y., Inoue, S., Matsudo, S. M., Mutrie, N., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-79 · Cited by 1,087
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Pedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752
Self-citation
Metadata
- Authors
- SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-10
- Volume
- 35
- Issue
- 10
- Pages
- 1779-1784
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2016387175
- Cited by
- 633
- References
- 18
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.