Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to determine the accuracy and reliability of the following electronic pedometers for measuring steps: Freestyle Pacer Pro (FR), Kenz Lifecorder (KZ), New Lifestyles NL-2000 (NL), Omron HJ-105 (OM), Oregon Scientific PE316CA (OR), Sportline 330 (SL330) and 345 (SL345), Walk4Life LS 2525 (WL), Yamax Skeletone EM-180 (SK), and the Yamax Digi-Walker SW-701 (DW). METHODS: Ten males (34.7 +/- 12.6 yr) (mean +/- SD) and 10 females (43.1 +/- 19.9 yr) ranging in BMI from 19.8 to 33.6 kg.m-2 walked 400-m around an outdoor track while wearing two pedometers of the same model (one on the right and left sides of the body) for each of 10 models. Four pedometers of each model were assessed in this fashion. The actual steps taken were tallied by a researcher. RESULTS: The KZ, NL, and DW were the most accurate in counting steps, displaying values that were within +/-3% of the actual steps taken, 95% of the time. The SL330 and OM were the least accurate, displaying values that were within +/-37% of the actual steps, 95% of the time. The reliability within a single model (Cronbach's alpha) was >0.80 for all pedometers with the exception of the SL330. The intramodel reliability was exceptionally high (>0.99) in the KZ, OM, NL, and the DW. CONCLUSION: Due to the variation that exists among models in regard to the internal mechanism and sensitivity, not all pedometers count steps accurately. Thus, it is important for researchers who use pedometers to assess physical activity to be aware of their accuracy and reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PHYSICAL ACTIVITY AS AN INDEX OF HEART ATTACK RISK IN COLLEGE ALUMNI1
PAFFENBARGER, R. S., WING, A. L., & HYDE, R. T. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112608 · Cited by 1,980
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Self-citationTudor-Locke, C. E., & Myers, A. M. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608926 · Cited by 518
Objective Monitoring of Physical Activity Using Motion Sensors and Heart Rate
Freedson, P. S., & Miller, K. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082782 · Cited by 482
Comparison of pedometer and accelerometer measures of free-living physical activity
TUDOR-LOCKE, C., AINSWORTH, B. E., THOMPSON, R. W., & MATTHEWS, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 386
Comprehensive evaluation of the Minnesota leisure time physical activity questionnaire
Richardson, M. T., Leon, A. S., Jacobs, D. R., Ainsworth, B. E., & Serfass, R. (1994) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)90008-6 · Cited by 363
Yamanouchi, K., Shinozaki, T., Chikada, K., Nishikawa, T., Ito, K., Shimizu, S., Ozawa, N., Suzuki, Y., Maeno, H., Kato, K., et al. (1995) · Diabetes Care · doi:10.2337/diacare.18.6.775 · Cited by 330
Increasing daily walking lowers blood pressure in postmenopausal women
MOREAU, K. L., DEGARMO, R., LANGLEY, J., MCMAHON, C., HOWLEY, E. T., BASSETT, D. R., & THOMPSON, D. L. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00005 · Cited by 280
Self-citationMeasurement of daily walking distance-questionnaire versus pedometer
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200005000-00021 · Cited by 260
Self-citation
Cited by
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
“Sixteen studies used the Yamax pedometer (Yamax Corp, Tokyo, Japan)—a model that has been well validated for accuracy and reliability and is frequently used in physical activity research.(41-44) The physical activity interventions evaluated in the included studies varied considerably: mean (SD) duration was 18 (24) we…”
MethodConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
How many steps/day are enough? for adults
Tudor-Locke, C., Craig, C. L., Brown, W. J., Clemes, S. A., De Cocker, K., Giles-Corti, B., Hatano, Y., Inoue, S., Matsudo, S. M., Mutrie, N., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-79 · Cited by 1,087
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Pedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752
Self-citationAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“We focused our interpretation of measurement accuracy based on predefined acceptable limits for measurement accuracy in controlled settings as a percentage difference of ±3% and acceptable limits for relative accuracy in free-living settings as a percentage difference of ±10% [19-22].”
MethodAssessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
An official European Respiratory Society statement on physical activity in COPD
Watz, H., Pitta, F., Rochester, C. L., Garcia-Aymerich, J., ZuWallack, R., Troosters, T., Vaes, A. W., Puhan, M. A., Jehn, M., Polkey, M. I., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00046814 · Cited by 526
How many days of pedometer monitoring predict weekly physical activity in adults?
TUDORLOCKE, C., BURKETT, L., REIS, J., AINSWORTH, B., MACERA, C., & WILSON, D. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2004.06.003 · Cited by 479
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Translating Physical Activity Recommendations into a Pedometer-Based Step Goal
Marshall, S. J., Levy, S. S., Tudor-Locke, C. E., Kolkhorst, F. W., Wooten, K. M., Ji, M., Macera, C. A., & Ainsworth, B. E. (2009) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2009.01.021 · Cited by 447
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Three studies (1 examining the inter-instrument reliability of a single pedometer and 2 examining the interinstrument reliability of multiple pedometers), identified that the majority of devices had acceptable levels of inter-instrument reliability (ICC ≥ 080) [446, 449, 457].”
BackgroundMethodInfluentialAssessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321
Physical Activity in Preschoolers: Understanding Prevalence and Measurement Issues
Oliver, M., Schofield, G. M., & Kolt, G. S. (2007) · Sports Medicine · doi:10.2165/00007256-200737120-00004 · Cited by 315
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
“The high level of accuracy of the NL-2000 outdoors supports the findings of Schneider et al. (2003), who reported the device’s accuracy to be within 3% of actual steps taken over a 400-m walk at a normal speed.”
BackgroundSpring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Self-citationTudor-Locke, C., Sisson, S. B., Collova, T., Lee, S. M., & Swan, P. D. (2005) · Canadian Journal of Applied Physiology · doi:10.1139/h05-147 · Cited by 292
Commercially available pedometers: considerations for accurate step counting
Melanson, E. L., Knoll, J. R., Bell, M. L., Donahoo, W. T., Hill, J. O., Nysse, L. J., Lanningham-Foster, L., Peters, J. C., & Levine, J. A. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2004.01.032 · Cited by 280
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Rowe, D. A., Mahar, M. T., Raedeke, T. D., & Lore, J. (2004) · Pediatric Exercise Science · doi:10.1123/pes.16.4.343 · Cited by 265
de Blok, B. M. J., de Greef, M. H. G., ten Hacken, N. H. T., Sprenger, S. R., Postema, K., & Wempe, J. B. (2006) · Patient Education and Counseling · doi:10.1016/j.pec.2005.02.005 · Cited by 231
Using Cadence to Study Free-Living Ambulatory Behaviour
Tudor-Locke, C., & Rowe, D. A. (2012) · Sports Medicine · doi:10.2165/11599170-000000000-00000 · Cited by 231
Motion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229
Pedestrian tracking using inertial sensors
Feliz Alonso, R., Zalama Casanova, E., & Gómez García-Bermejo, J. (2009) · Journal of Physical Agents (JoPha) · doi:10.14198/jopha.2009.3.1.05 · Cited by 228
“Some methods are based on step counters and estimate the distance covered using an average step length [1], [2], [3].”
MethodUsing Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
Kirwan, M., Duncan, M. J., Vandelanotte, C., & Mummery, W. K. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1950 · Cited by 189
Physical Activity and Depression in Young Adults
McKercher, C. M., Schmidt, M. D., Sanderson, K. A., Patton, G. C., Dwyer, T., & Venn, A. J. (2009) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2008.09.036 · Cited by 174
Can implementation intentions and text messages promote brisk walking? A randomized trial.
Prestwich, A., Perugini, M., & Hurling, R. (2010) · Health Psychology · doi:10.1037/a0016993 · Cited by 158
The Accuracy of Pedometer Steps and Time during Walking in Children
BEETS, M. W., PATTON, M. M., & EDWARDS, S. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000155395.49960.31 · Cited by 166
Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001569 · Cited by 154
Self-citationEvaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159
Self-citationMatsuzawa, R., Matsunaga, A., Wang, G., Kutsuna, T., Ishii, A., Abe, Y., Takagi, Y., Yoshida, A., & Takahira, N. (2012) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03660412 · Cited by 159
“The accuracy and reliability of the instrument have been reported in previous studies (24,25).”
MethodKing, W. C., Hsu, J. Y., Belle, S. H., Courcoulas, A. P., Eid, G. M., Flum, D. R., Mitchell, J. E., Pender, J. R., Smith, M. D., Steffen, K. J., et al. (2012) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2011.07.018 · Cited by 153
Évaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
“Other studies recommend that mean errors of less than 20% have acceptable validity for clinical purposes [43].”
BackgroundComparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Self-citationMeasuring physical activity during pregnancy
Harrison, C. L., Thompson, R. G., Teede, H. J., & Lombard, C. B. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-19 · Cited by 139
Carr, L. J., Bartee, R. T., Dorozynski, C., Broomfield, J. F., Smith, M. L., & Smith, D. T. (2008) · Preventive Medicine · doi:10.1016/j.ypmed.2007.12.005 · Cited by 118
Eather, N., Morgan, P. J., & Lubans, D. R. (2013) · Preventive Medicine · doi:10.1016/j.ypmed.2012.10.019 · Cited by 110
Reactivity: an issue for short-term pedometer studies?: Figure 1
Clemes, S. A., Matchett, N., & Wane, S. L. (2008) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.038521 · Cited by 106
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87
Identification and Classification of Usage Patterns in Long-Term Activity Tracking
Meyer, J., Wasmann, M., Heuten, W., El Ali, A., & Boll, S. C. J. (2017) · Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3025453.3025690 · Cited by 72
Validity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
Self-citationCleland, V., Dwyer, T., Blizzard, L., & Venn, A. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-14 · Cited by 61
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46
Self-citationFour-week pedometer-determined activity patterns in normal weight and overweight UK adults
Clemes, S. A., Griffiths, P. L., & Hamilton, S. L. (2007) · International Journal of Obesity · doi:10.1038/sj.ijo.0803420 · Cited by 36
Effects of Body Mass Index and Tilt Angle on Output of Two Wearable Activity Monitors
FEITO, Y., BASSETT, D. R., TYO, B., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181fefd40 · Cited by 32
“Accelerorheter-based activity monitors and pedometers are often used to provide objective measures of physical activity (11,18,23).”
Self-citationFemiano, R., Werner, C., Wilhelm, M., & Eser, P. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2021.11.035 · Cited by 31
Wahl-Alexander, Z., Brusseau, T., & Burns, R. (2020) · SCHOLE: A Journal of Leisure Studies and Recreation Education · doi:10.1080/1937156x.2020.1718039 · Cited by 5
Metadata
- Authors
- SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-10
- Volume
- 35
- Issue
- 10
- Pages
- 1779-1784
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2016387175
- Cited by
- 633
- References
- 18
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.