Pedometer Accuracy in Nursing Home and Community-Dwelling Older Adults
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
PURPOSE: The accuracy of pedometers has not been thoroughly tested with older adult populations. The purpose of the present study was to examine the effects of walking speed and gait disorders on the accuracy of Yamax pedometers with nursing home residents (NH) relative to older adults living in the community. METHODS: Pedometer accuracy was evaluated against observed steps taken during a self-paced walking test (slow, normal, and fast speeds) in 26 NH residents and 28 seniors' recreation center members (SC). Devices were attached to clothing at the waist. Walking speed was ascertained from the timed walk and a gait assessment was conducted. Percent error was calculated as ([pedometer steps - observed steps]/observed steps) x 100. RESULTS: The walking speeds of both samples increased across self-selected paces (P < 0.0001). The community-dwelling older adults walked significantly faster (P < 0.0001) in all trials and had significantly higher (P < 0.0001) gait assessment scores (indicating fewer gait problems). Gait scores were positively associated with walking speed and pedometer percent error. Pedometers significantly underestimated NH residents' observed steps taken by 74% (slow), 55% (normal), and 46% (fast) paces (P < 0.0001). In the SC sample, the instruments failed to detect 25%, 13%, and 7% of actual steps taken, respectively (P < 0.0001). The magnitude of the error was greater for NH versus SC older adults (P < 0.0001) across all trials. CONCLUSIONS: Slow walking speed and gait disorders hamper the utility of pedometers for physical activity measurement in frail seniors, such as NH residents, when worn at the usual attachment site. Pedometers, however, can be confidently used with ostensibly healthy older adult populations for both assessment and motivation purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance‐Oriented Assessment of Mobility Problems in Elderly Patients
Tinetti, M. E. (1986) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1986.tb05480.x · Cited by 3,352
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Steffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
An Objective Measure of Physical Function of Elderly Outpatients: The Physical Performance Test
Reuben, D. B., & Siu, A. L. (1990) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1990.tb01373.x · Cited by 728
Physical activity interventions targeting older adults
King, A. C., Rejeski, W. J., & Buchner, D. M. (1998) · American Journal of Preventive Medicine · doi:10.1016/s0749-3797(98)00085-3 · Cited by 567
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Challenges and Opportunities for Measuring Physical Activity in Sedentary Adults
Tudor-Locke, C. E., & Myers, A. M. (2001) · Sports Medicine · doi:10.2165/00007256-200131020-00002 · Cited by 519
Self-citationTudor-Locke, C. E., & Myers, A. M. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608926 · Cited by 518
Self-citationValidity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Cited by
How many steps/day are enough? For older adults and special populations
Tudor-Locke, C., Craig, C. L., Aoyagi, Y., Bell, R. C., Croteau, K. A., De Bourdeaudhuij, I., Ewald, B., Gardner, A. W., Hatano, Y., Lutes, L. D., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-80 · Cited by 1,076
Self-citationNormal walking speed: a descriptive meta-analysis
Bohannon, R. W., & Williams Andrews, A. (2011) · Physiotherapy · doi:10.1016/j.physio.2010.12.004 · Cited by 922
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Pedometers had relatively high levels of accuracy across all speeds, but appear to be more accurate at determining step-count at higher walking speeds compared to lower walking speeds (Additional file 1: Table S11) [306, 436, 438, 439].”
BackgroundMurphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Miles, L. (2007) · Nutrition Bulletin · doi:10.1111/j.1467-3010.2007.00668.x · Cited by 299
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
Validity of physical activity monitors during daily life in patients with COPD
Rabinovich, R. A., Louvaris, Z., Raste, Y., Langer, D., Van Remoortel, H., Giavedoni, S., Burtin, C., Regueiro, E. M. G., Vogiatzis, I., Hopkinson, N. S., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00134312 · Cited by 293
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Harris, T. J., Owen, C. G., Victor, C. R., Adams, R., & Cook, D. G. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.048033 · Cited by 236
Kowalski, K., Rhodes, R., Naylor, P.-J., Tuokko, H., & MacDonald, S. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-148 · Cited by 212
“Eleven studies compared indirect measures with other indirect PA measures [16,32,33,37,45,47,48,5154] and fourteen studies compared direct measures with other direct PA measures [38,41,43,55-65].”
BackgroundMethodInfluentialUsing Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
A Comparison of Questionnaire, Accelerometer, and Pedometer: Measures in Older People
HARRIS, T. J., OWEN, C. G., VICTOR, C. R., ADAMS, R., EKELUND, U., & COOK, D. G. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31819b3533 · Cited by 202
“Although treadmill studies suggest pedometers underestimate steps at slow speeds, this is typically approximately 54 mImin (20); the strong agreement between our instruments may be due to a generally higher walking speed in our participants, as suggested by a study where pedometers accurately recorded communitydwellin…”
ResultTaraldsen, K., Chastin, S. F. M., Riphagen, I. I., Vereijken, B., & Helbostad, J. L. (2012) · Maturitas · doi:10.1016/j.maturitas.2011.11.003 · Cited by 197
Physical activity levels in older adults with intellectual disabilities are extremely low
Hilgenkamp, T. I. M., Reis, D., van Wijck, R., & Evenhuis, H. M. (2012) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2011.10.011 · Cited by 183
Number of Pedometer-Assessed Steps Taken Per Day by Adults: A Descriptive Meta-Analysis
Bohannon, R. W. (2007) · Physical Therapy · doi:10.2522/ptj.20060037 · Cited by 174
Wearable systems for monitoring mobility-related activities in older people: a systematic review
de Bruin, E. D., Hartmann, A., Uebelhart, D., Murer, K., & Zijlstra, W. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508090675 · Cited by 170
The Accuracy of Pedometer Steps and Time during Walking in Children
BEETS, M. W., PATTON, M. M., & EDWARDS, S. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000155395.49960.31 · Cited by 166
Position-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
Improving physical activity in COPD: towards a new paradigm
Troosters, T., van der Molen, T., Polkey, M., Rabinovich, R. A., Vogiatzis, I., Weisman, I., & Kulich, K. (2013) · Respiratory Research · doi:10.1186/1465-9921-14-115 · Cited by 158
“Although pedometers may underestimate the amount of physical activity, particularly slow-walking [36], and offer no information on the pattern of physical activity or the time spent in different activities [37], several studies have shown that they can capture physical activity in patients with COPD [38-40].”
BackgroundComparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Vaes, A. W., Cheung, A., Atakhorrami, M., Groenen, M. T. J., Amft, O., Franssen, F. M. E., Wouters, E. F. M., & Spruit, M. A. (2013) · Annals of Medicine · doi:10.3109/07853890.2013.810891 · Cited by 119
Normative Steps/Day Values for Older Adults: NHANES 2005-2006
Tudor-Locke, C., Schuna, J. M., Barreira, T. V., Mire, E. F., Broyles, S. T., Katzmarzyk, P. T., & Johnson, W. D. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glt116 · Cited by 110
Self-citationFitzpatrick, S. E., Reddy, S., Lommel, T. S., Fischer, J. G., Speer, E. M., Stephens, H., Park, S., & Johnson, M. A. (2008) · Journal of Nutrition For the Elderly · doi:10.1080/01639360802060223 · Cited by 64
Validity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
“In nursing-home residents, Yamax pedometers significantly underestimated steps, particularly for those who have significant ambulatory impairment or a slow shuffling gait.(15) The accuracy of these devices, however, has not been tested in assisted-care residents.”
BackgroundGrant, P. M., Granat, M. H., Thow, M. K., & Maclaren, W. M. (2010) · Journal of Aging and Physical Activity · doi:10.1123/japa.18.2.171 · Cited by 60
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46
Manohar, C. U., Koepp, G. A., McCrady-Spitzer, S. K., & Levine, J. A. (2012) · ICAN: Infant, Child, & Adolescent Nutrition · doi:10.1177/1941406412450644 · Cited by 12
Metadata
- Authors
- CYARTO, E. V., MYERS, A. M., & TUDOR-LOCKE, C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-02
- Volume
- 36
- Issue
- 2
- Pages
- 205-209
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1969630774
- Cited by
- 236
- References
- 29
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.