Improving Energy Expenditure Estimation for Physical Activity
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to validate the Intelligent Device for Energy Expenditure and Activity (IDEEA) for estimation of energy expenditure during a variety of activities. An additional aim was to improve the accuracy of the estimation of energy expenditure of physical activity based on second-by-second information of type, onset, and duration of activity. METHODS: This study included two tests: a mask calorimetry test with 27 subjects [age = 33.7 +/- 13.8 (mean +/- SD) yr; BMI = 24.8 +/- 4.8 kg x m] and a respiratory chamber calorimetry test with 10 subjects (age = 32.9 +/- 12.4 yr; BMI = 26.1 +/- 5.6 kg x m). In the mask test, the subjects performed activities (sitting, standing, lying down, level treadmill walking, and running at different speeds) for 50-min durations. For the chamber test, subjects lived in the metabolic chamber for 23 h and performed three exercise sessions to compensate for the confined environment. RESULTS: The results showed significant correlations (P < 0.0001) between energy expenditure estimated by IDEEA and energy expenditure measured by the calorimeters with an accuracy >95%. After corrections for the decrease in sleeping metabolic rate, the estimation accuracy for the chamber test was increased by 1-96.2%, whereas the estimation accuracy for nighttime activity was significantly improved by 4-99%. CONCLUSION: IDEEA provides a suitable method for estimating the energy expenditure of physical activity. It provides both instantaneous and cumulative estimates of energy expenditure over a given period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compendium of Physical Activities: Classification of energy costs of human physical activities
AINSWORTH, B. E., HASKELL, W. L., LEON, A. S., JACOBS, D. R., MONTOYE, H. J., SALLIS, J. F., & PAFFENBARGER, R. S. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199301000-00011 · Cited by 4,102
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643 · cited 1×
“Heart rate monitors (8,14,15), pedometers (8,9,27), and accelerometers (3,5– 7,10,12,16,17,25) give poor and inconsistent results in estimating individual energy expenditure of physical activity (EEpa).”
BackgroundHow accurate is self-reported dietary energy intake?
Schoeller, D. A. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1990.tb02882.x · Cited by 559 · cited 1×
“Diet records (22,24,28) and activity questionnaires (1,18,26) are less reliable.”
Background
Cited by
The evolving definition of “sedentary.”
Pate, R. R., O'Neill, J. R., & Lobelo, F. (2008) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181877d1a · Cited by 1,280
“Some of these instruments are currently in development and testing, and they are promising because they detect the energy expended in activities that typically are considered sedentary, such as sitting, lying down, changing postures, moving limbs, and fidgeting, as well as light, moderate, and vigorous activities (13,…”
BackgroundCalibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
“The IDEEA has been used in monitoring PA of obese people in real life environment [82], and has been validated in the study of ambulatory measurement for gait analysis [83], and EE estimation of PA [84].”
MethodStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Young, D. R., Hivert, M.-F., Alhassan, S., Camhi, S. M., Ferguson, J. F., Katzmarzyk, P. T., Lewis, C. E., Owen, N., Perry, C. K., Siddique, J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000440 · Cited by 791
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
“, raw acceleration or 1-s epochs) recently have been used to identify specific types of behavior (6,25,29,40) and energy expenditure (6,26,29,39).”
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Measurement of Adults' Sedentary Time in Population-Based Studies
Healy, G. N., Clark, B. K., Winkler, E. A. H., Gardiner, P. A., Brown, W. J., & Matthews, C. E. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.005 · Cited by 628
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Assessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
A Practical Approach to Recognizing Physical Activities
Lester, J., Choudhury, T., & Borriello, G. (2006) · Lecture Notes in Computer Science · doi:10.1007/11748625_1 · Cited by 464
Assessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
Qasem, L., Cardew, A., Wilson, A., Griffiths, I., Halsey, L. G., Shepard, E. L. C., Gleiss, A. C., & Wilson, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031187 · Cited by 399
“Fundamental to the amount of oxygen used by a body is the amount of muscle tissue that is active [46] and the precise orientation of various muscle groups involved in limb movement is critical in this regard.”
BackgroundAssessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Graves, L., Stratton, G., Ridgers, N. D., & Cable, N. T. (2007) · BMJ · doi:10.1136/bmj.39415.632951.80 · Cited by 334
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Calibration and Validation of Wearable Monitors
BASSETT, D. R., ROWLANDS, A., & TROST, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 292
Active Video Games for Youth: A Systematic Review
Barnett, A., Cerin, E., & Baranowski, T. (2011) · Journal of Physical Activity and Health · doi:10.1123/jpah.8.5.724 · Cited by 282
Field Validation of the MTI Actigraph and BodyMedia Armband Monitor Using the IDEEA Monitor
Welk, G. J., McClain, J. J., Eisenmann, J. C., & Wickel, E. E. (2007) · Obesity · doi:10.1038/oby.2007.624 · Cited by 244
“A follow-up report (16) evaluated the accuracy of the EE estimates from the internal IDEEA algorithms.”
BackgroundMethodMonitoring of Posture Allocations and Activities by a Shoe-Based Wearable Sensor
Sazonov, E. S., Fulk, G., Hill, J., Schutz, Y., & Browning, R. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2046738 · Cited by 238
“An array of 32 plantar pressure sensors was used in [25] to classify locomotion (walking, running, and up/down stairs) with reported accuracies of ∼98%.”
Development of Novel Techniques to Classify Physical Activity Mode Using Accelerometers
POBER, D. M., STAUDENMAYER, J., RAPHAEL, C., & FREEDSON, P. S. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000227542.43669.45 · Cited by 210
“used probabilistic neural networks to extract information about the type, duration, and intensity of activity from a new type of accelerometer-based PA monitor (35,36).”
BackgroundMethodMETs in Adults While Playing Active Video Games: A Metabolic Chamber Study
MIYACHI, M., YAMAMOTO, K., OHKAWARA, K., & TANAKA, S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c51c78 · Cited by 195
Lagerros, Y. T., & Lagiou, P. (2007) · European Journal of Epidemiology · doi:10.1007/s10654-007-9154-x · Cited by 178
“Among them are a combined heart rate recorder and movement sensor [50] and a device for analyzing body motion and posture changes resulting in a detailed record of performed activity [51].”
BackgroundProtocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124
“The Intelligent Device for Energy Expenditure and Activity (MiniSun LLC, Fresno, CA) monitor operates similarly and integrates data from five sensors to detect postures and then applies standard prediction equations to estimate energy cost (34).”
BackgroundModeling Physical Activity Outcomes from Wearable Monitors
HEIL, D. P., BRAGE, S., & ROTHNEY, M. P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399dcc · Cited by 121
“, sitting, standing, walking, lifestyle activities) or the actual identification of specific activities (standing quietly vs standing and washing dishes) will require the use of more sophisticated wearable monitors, such as those based on artificial neural networks (24,25,33,34).”
BackgroundInfluentialPhysical activity monitoring in obese people in the real life environment
Benedetti, M. G., Di Gioia, A., Conti, L., Berti, L., Esposti, L. D., Tarrini, G., Melchionda, N., & Giannini, S. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-47 · Cited by 44
Metadata
- Authors
- ZHANG, K., PI-SUNYER, F. X., & BOOZER, C. N.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-05
- Volume
- 36
- Issue
- 5
- Pages
- 883-889
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2108955267
- Cited by
- 180
- References
- 3
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.