Twenty-four Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Getting enough sleep, exercising, and limiting sedentary activities can greatly contribute to disease prevention and overall health and longevity. Measuring the full 24-h activity cycle-sleep, sedentary behavior (SED), light-intensity physical activity (LPA), and moderate-to-vigorous physical activity (MVPA)-may now be feasible using small wearable devices. PURPOSE: This study compared nine devices for accuracy in a 24-h activity measurement. METHODS: Adults (n = 40, 47% male) wore nine devices for 24 h: ActiGraph GT3X+, activPAL, Fitbit One, GENEactiv, Jawbone Up, LUMOback, Nike Fuelband, Omron pedometer, and Z-Machine. Comparisons (with standards) were made for total sleep time (Z-machine), time spent in SED (activPAL), LPA (GT3X+), MVPA (GT3X+), and steps (Omron). Analysis included mean absolute percent error, equivalence testing, and Bland-Altman plots. RESULTS: Error rates ranged from 8.1% to 16.9% for sleep, 9.5% to 65.8% for SED, 19.7% to 28.0% for LPA, 51.8% to 92% for MVPA, and 14.1% to 29.9% for steps. Equivalence testing indicated that only two comparisons were significantly equivalent to standards: the LUMOback for SED and the GT3X+ for sleep. Bland-Altman plots indicated GT3X+ had the closest measurement for sleep, LUMOback for SED, GENEactiv for LPA, Fitbit for MVPA, and GT3X+ for steps. CONCLUSIONS: Currently, no device accurately captures activity data across the entire 24-h day, but the future of activity measurement should aim for accurate 24-h measurement as a goal. Researchers should continue to select measurement devices on the basis of their primary outcomes of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“The ActiGraph GT3X+ is a frequently used device for LPA and MVPA measurement (40).”
(2007) · Circulation · doi:10.1161/circulationaha.107.185649 · Cited by 6,545 · cited 2×
“S ubstantial evidence has led to recommendations for adequate exercise, healthy sleep habits, and limited sedentary behavior for increased longevity, improved health, and disease prevention (7,14,21).”
Self-citation2011 Compendium of Physical Activities: A Second Update of Codes and MET Values
AINSWORTH, B. E., HASKELL, W. L., HERRMANN, S. D., MECKES, N., BASSETT, D. R., TUDOR-LOCKE, C., GREER, J. L., VEZINA, J., WHITT-GLOVER, M. C., & LEON, A. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821ece12 · Cited by 6,317 · cited 7×
“The GT3X+ provides a measure of MVPA different from the measures of MVPA provided by the other devices, but it is not necessarily more accurate at measuring activities with energy expenditure above 3 METs.”
InfluentialSelf-citationCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 3×
“Fuelband A GT3X+ cut point of Q1580 counts per minute was used as the standard (11).”
Too Much Sitting: The Population Health Science of Sedentary Behavior
Owen, N., Healy, G. N., Matthews, C. E., & Dunstan, D. W. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181e373a2 · Cited by 2,202 · cited 8×
“The GT3X+ provides a measure of MVPA different from the measures of MVPA provided by the other devices, but it is not necessarily more accurate at measuring activities with energy expenditure above 3 METs.”
InfluentialCappuccio, F. P., Cooper, D., D'Elia, L., Strazzullo, P., & Miller, M. A. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr007 · Cited by 2,146
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
CORONARY HEART-DISEASE AND PHYSICAL ACTIVITY OF WORK
Morris, J. N., Heady, J. A., Raffle, P. A. B., Roberts, C. G., & Parks, J. W. (1953) · The Lancet · doi:10.1016/s0140-6736(53)90665-5 · Cited by 1,698
A simultaneous evaluation of 10 commonly used physical activity questionnaires
JACOBS, D. R., AINSWORTH, B. E., HARTMAN, T. J., & LEON, A. S. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199301000-00012 · Cited by 1,675
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[34,49,52,73,80,88,90,92,93,98,100,102,103,110, 116-118,120-138] Ankle/foot, pant pocket, waist/hip, or wrist Discontinued 2012 One Fitbit”
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Association of daily step count and step intensity with mortality among US adults
Saint-Maurice, P. F., Troiano, R. P., Bassett, D. R., Graubard, B. I., Carlson, S. A., Shiroma, E. J., Fulton, J. E., & Matthews, C. E. (2020) · JAMA · doi:10.1001/jama.2020.1382 · Cited by 660
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625
Sullivan, A. N., & Lachman, M. E. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00289 · Cited by 458
Health at hand: A systematic review of smart watch uses for health and wellness
Reeder, B., & David, A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2016.09.001 · Cited by 407
Lobelo, F., Rohm Young, D., Sallis, R., Garber, M. D., Billinger, S. A., Duperly, J., Hutber, A., Pate, R. R., Thomas, R. J., Widlansky, M. E., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000559 · Cited by 402
Self-citationThe 24-Hour Activity Cycle: A New Paradigm for Physical Activity
ROSENBERGER, M. E., FULTON, J. E., BUMAN, M. P., TROIANO, R. P., GRANDNER, M. A., BUCHNER, D. M., & HASKELL, W. L. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001811 · Cited by 372
Self-citationWearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
Mantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314
Nelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310
“We recognize that this is more lenient than some prior health sciences research on wearable HR accuracy [7] and pedometer step counting accuracy [40,41] that have defined an acceptable error rate to be ±5%.”
Exercise Dose in Clinical Practice
Wasfy, M. M., & Baggish, A. L. (2016) · Circulation · doi:10.1161/circulationaha.116.018093 · Cited by 268
Sallis, J. F., Adlakha, D., Oyeyemi, A., & Salvo, D. (2020) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2020.05.005 · Cited by 254
Kuzik, N., Poitras, V. J., Tremblay, M. S., Lee, E.-Y., Hunter, S., & Carson, V. (2017) · BMC Public Health · doi:10.1186/s12889-017-4851-1 · Cited by 246
McConnell, M. V., Shcherbina, A., Pavlovic, A., Homburger, J. R., Goldfeder, R. L., Waggot, D., Cho, M. K., Rosenberger, M. E., Haskell, W. L., Myers, J., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.4395 · Cited by 239
Self-citationHow consumer physical activity monitors could transform human physiology research
Wright, S. P., Hall Brown, T. S., Collier, S. R., & Sandberg, K. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00349.2016 · Cited by 234
Fitbit-based interventions for healthy lifestyle outcomes: systematic review and meta-analysis
Ringeval, M., Wagner, G., Denford, J., Paré, G., & Kitsiou, S. (2020) · Journal of Medical Internet Research · doi:10.2196/23954 · Cited by 225
“We focused on Fitbit devices because they are among the most accurate commercially available wearables [39-43] and are, in some cases, comparable to research-grade monitors [44].”
ResultBaron, K. G., Duffecy, J., Berendsen, M. A., Cheung Mason, I., Lattie, E. G., & Manalo, N. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.12.002 · Cited by 186
“Multiple studies published comparisons between devices, typically focusing on comparing different brands of consumer-targeted actigraphy [18,22,25,27,28,30,36].”
Wearable Technology and How This Can Be Implemented into Clinical Practice
Greiwe, J., & Nyenhuis, S. M. (2020) · Current Allergy and Asthma Reports · doi:10.1007/s11882-020-00927-3 · Cited by 167
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
Gothe, N. P., Ehlers, D. K., Salerno, E. A., Fanning, J., Kramer, A. F., & McAuley, E. (2020) · Behavioral Sleep Medicine · doi:10.1080/15402002.2019.1690493 · Cited by 125
“This is of particular interest, as there is at present limited evidence on the optimal structure of physical activity for promoting healthy sleep (Rosenberger et al., 2016).”
BackgroundChowdhury, E. A., Western, M. J., Nightingale, T. E., Peacock, O. J., & Thompson, D. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171720 · Cited by 118
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O’Flynn, B. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216891 · Cited by 116
Promises and Challenges in the Use of Consumer-Grade Devices for Sleep Monitoring
Roomkham, S., Lovell, D., Cheung, J., & Perrin, D. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2811735 · Cited by 79
Liang, Z., & Chapa-Martell, M. A. (2019) · JMIR mHealth and uHealth · doi:10.2196/13384 · Cited by 76
“In line with previous studies [62,63], we defined the acceptable error range as e i ≤5%, as this approximates a widely acceptable standard for statistical significance in literature [64].”
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Degroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
“The validity to measure PA in free-living conditions has been examined for several activity trackers, such as Fitbit One, Zip, Ultra, Classic, Flex [16-18,33-38], Misfit Shine [18], and Withings Pulse [18].”
BackgroundMethodInfluentialO’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“92% were reported when compared with EEG based sleep duration (134), indicating none were capable of accurately capturing activity data across the entire day.”
BackgroundMelton, B. F., Buman, M. P., Vogel, R. L., Harris, B. S., & Bigham, L. E. (2016) · Journal of Black Studies · doi:10.1177/0021934716653349 · Cited by 36
Self-citationReconnecting the Brain With the Rest of the Body in Musculoskeletal Pain Research
Langevin, H. M. (2021) · The Journal of Pain · doi:10.1016/j.jpain.2020.02.006 · Cited by 24
Mahloko, L., & Adebesin, F. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-45002-1_9 · Cited by 23
Metadata
- Authors
- ROSENBERGER, M. E., BUMAN, M. P., HASKELL, W. L., MCCONNELL, M. V., & CARSTENSEN, L. L.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2016-03
- Volume
- 48
- Issue
- 3
- Pages
- 457-465
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2395057358
- Cited by
- 295
- References
- 42
- FWCI
- 20.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.