Accuracy of Posture Allocation Algorithms for Thigh- and Waist-Worn Accelerometers
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE: The objective of this study is to compare the accuracy of the activPAL and ActiGraph GT3X+ (waist and thigh) proprietary postural allocation algorithms and an open-source postural allocation algorithm applied to GENEActiv (thigh) and ActiGraph GT3X+ (thigh) data. METHODS: Thirty-four adults (≥18 yr) wore the activPAL3, GENEActiv, and ActiGraph GT3X+ on the right thigh and an ActiGraph on the right hip while performing four lying, seven sitting, and five upright activities in the laboratory. Lying and sitting tasks incorporated a range of leg angles (e.g., lying with legs bent and sitting with legs crossed). Each activity was performed for 5 min while being directly observed. The percentage of the time the posture was correctly classified was calculated. RESULTS: Participants consisted of 14 males and 20 females (mean age, 27.2 ± 5.9 yr; mean body mass index, 23.8 ± 3.7 kg·m). All postural allocation algorithms applied to monitors worn on the thigh correctly classified ≥93% of the time lying, ≥91% of the time sitting, and ≥93% of the time upright. The ActiGraph waist proprietary algorithm correctly classified 72% of the time lying, 58% of the time sitting, and 74% of the time upright. Both the activPAL and ActiGraph thigh proprietary algorithms misclassified sitting on a chair with legs stretched out (58% and 5% classified incorrectly, respectively). The ActiGraph thigh proprietary and open-source algorithm applied to the thigh-worn ActiGraph misclassified participants lying on their back with their legs bent 27% and 9% of the time, respectively. CONCLUSION: All postural allocation algorithms when applied to devices worn on the thigh were highly accurate in identifying lying, sitting, and upright postures. Given the poor accuracy of the waist algorithm for detecting sitting, caution should be taken if inferring sitting time from a waist-worn device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biswas, A., Oh, P. I., Faulkner, G. E., Bajaj, R. R., Silver, M. A., Mitchell, M. S., & Alter, D. A. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1651 · Cited by 2,726
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Wilmot, E. G., Edwardson, C. L., Achana, F. A., Davies, M. J., Gorely, T., Gray, L. J., Khunti, K., Yates, T., & Biddle, S. J. H. (2012) · Diabetologia · doi:10.1007/s00125-012-2677-z · Cited by 1,789 · cited 1×
“However, the majority of epidemiological studies to date have used either self-reported sedentary behavior measures or objective measures that infer sedentary behavior through lack of movement (5,29).”
BackgroundSelf-citationSedentary Behaviors and Subsequent Health Outcomes in Adults
Thorp, A. A., Owen, N., Neuhaus, M., & Dunstan, D. W. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.004 · Cited by 1,455
Sedentary behavior and health outcomes among older adults: a systematic review
Rezende, L. F. M. D., Rey-López, J. P., Matsudo, V. K. R., & Luiz, O. D. C. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-333 · Cited by 685
Methods of Measurement in epidemiology: Sedentary Behaviour
Atkin, A. J., Gorely, T., Clemes, S. A., Yates, T., Edwardson, C., Brage, S., Salmon, J., Marshall, S. J., & Biddle, S. J. (2012) · International Journal of Epidemiology · doi:10.1093/ije/dys118 · Cited by 518
Self-citationAssessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359 · cited 1×
“A key recommendation from the 2009 Objective Measurement of Physical Activity Meeting, cosponsored by the National Institutes of Health and the American College of Sports Medicine, was that monitor data should be collected and saved as raw signals, with data transformation carried out postprocessing to facilitate comp…”
MethodHenson, J., Davies, M. J., Bodicoat, D. H., Edwardson, C. L., Gill, J. M. R., Stensel, D. J., Tolfrey, K., Dunstan, D. W., Khunti, K., & Yates, T. (2016) · Diabetes Care · doi:10.2337/dc15-1240 · Cited by 270
Self-citationProtocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124 · cited 1×
“A key recommendation from the 2009 Objective Measurement of Physical Activity Meeting, cosponsored by the National Institutes of Health and the American College of Sports Medicine, was that monitor data should be collected and saved as raw signals, with data transformation carried out postprocessing to facilitate comp…”
MethodStanding-based office work shows encouraging signs of attenuating post-prandial glycaemic excursion
Buckley, J. P., Mellor, D. D., Morris, M., & Joseph, F. (2014) · Occupational and Environmental Medicine · doi:10.1136/oemed-2013-101823 · Cited by 124 · cited 1×
“This is important given that recent experimental research has demonstrated that even light activity such as standing still can have a positive effect on markers of health (6,16,26).”
Background
Cited by
Prince, S. A., Cardilli, L., Reed, J. L., Saunders, T. J., Kite, C., Douillette, K., Fournier, K., & Buckley, J. P. (2020) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-020-00938-3 · Cited by 520
Effectiveness of the Stand More AT (SMArT) Work intervention: cluster randomised controlled trial
Edwardson, C. L., Yates, T., Biddle, S. J. H., Davies, M. J., Dunstan, D. W., Esliger, D. W., Gray, L. J., Jackson, B., O’Connell, S. E., Waheed, G., et al. (2018) · BMJ · doi:10.1136/bmj.k3870 · Cited by 272
Self-citationYates, T., Edwardson, C. L., Celis-Morales, C., Biddle, S. J. H., Bodicoat, D., Davies, M. J., Esliger, D., Henson, J., Kazi, A., Khunti, K., et al. (2020) · The Journals of Gerontology: Series A · doi:10.1093/gerona/gly252 · Cited by 87
Self-citationValidity of the ActivPAL monitor to distinguish postures: A systematic review
O’Brien, M. W., Wu, Y., Petterson, J. L., Bray, N. W., & Kimmerly, D. S. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2022.03.002 · Cited by 81
Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V. (2022) · Sensors · doi:10.3390/s22249984 · Cited by 30
Self-citation
Metadata
- Authors
- EDWARDSON, C. L., ROWLANDS, A. V., BUNNEWELL, S., SANDERS, J., ESLIGER, D. W., GORELY, T., O’CONNELL, S., DAVIES, M. J., KHUNTI, K., & YATES, T.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2016-06
- Volume
- 48
- Issue
- 6
- Pages
- 1085-1090
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2265508650
- Cited by
- 131
- References
- 10
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Posture Allocation Algorithms for Thigh- and Waist-Worn Accelerometers. https://app.cochat.ai/papers/10.1249/mss.0000000000000865
- The paper
- EDWARDSON, C. L., ROWLANDS, A. V., BUNNEWELL, S., SANDERS, J., ESLIGER, D. W., GORELY, T., O’CONNELL, S., DAVIES, M. J., KHUNTI, K., & YATES, T. (2016). Accuracy of Posture Allocation Algorithms for Thigh- and Waist-Worn Accelerometers. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000865
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.