The Respiratory Compensation Point and the Deoxygenation Break Point Are Valid Surrogates for Critical Power and Maximum Lactate Steady State
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
For any type of endurance exercise, there exists a range of task-specific intensities (e.g., speed or power output) that can be sustained in steady-state conditions by oxidative metabolism without a progressive depletion of high-energy phosphates or continuous lactate accumulation. The task-specific intensity at the ceiling of this range identifies a metabolic rate above which oxidative phosphorylation must be further supported at the substrate level for exercise to continue, leading to non–steady-state conditions, accumulation of muscle metabolites, acidification of the tissue, and a hastening of exhaustion. This “critical metabolic rate” that defines sustainable from unsustainable exercise often is identified by measuring critical power (CP) or the maximal lactate steady-state (MLSS). We suggest also that the respiratory compensation point (RCP) and the near infrared spectroscopy-derived muscle deoxygenation break point (deoxy-BP) of ramp-incremental exercise reflect this important boundary. Our group showed that the oxygen uptakes (V˙O2) associated with CP, MLSS, RCP, and deoxy-BP were not different in a single cohort of healthy volunteers (1). Although this is the only study to compare simultaneously all of these variables, other comparative studies have corroborated V˙O2 as a common denominator among these indices (2,3), supporting the idea that all represent different physiological expressions of the same underlying phenomenon. Still, others have denied the equivalence…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Multiple studies have validated various stationary NIRS sensors with each of the physiological and performance markers outlined above, during various modes of exercise (12, 17, 22, 29–31).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [12]
Citations
Cites
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Self-citationMeyer, T., Faude, O., Scharhag, J., Urhausen, A., & Kindermann, W. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.007815 · Cited by 114
Using ramp-incremental V̇O2 responses for constant-intensity exercise selection
Keir, D. A., Paterson, D. H., Kowalchuk, J. M., & Murias, J. M. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0826 · Cited by 97
Self-citationCritical power: How different protocols and models affect its determination
Mattioni Maturana, F., Fontana, F. Y., Pogliaghi, S., Passfield, L., & Murias, J. M. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.11.015 · Cited by 93
Self-citationCan measures of critical power precisely estimate the maximal metabolic steady-state?
Mattioni Maturana, F., Keir, D. A., McLay, K. M., & Murias, J. M. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2016-0248 · Cited by 69
Self-citationDetermination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65
Self-citationKeir, D. A., Benson, A. P., Love, L. K., Robertson, T. C., Rossiter, H. B., & Kowalchuk, J. M. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00804.2015 · Cited by 49
Self-citationThe Respiratory Compensation Point is Not a Valid Surrogate for Critical Power
LEO, J. A., SABAPATHY, S., SIMMONDS, M. J., & CROSS, T. J. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001226 · Cited by 47
Exercise Thresholds on Trial: Are They Really Equivalent?
CAEN, K., VERMEIRE, K., BOURGOIS, J. G., & BOONE, J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001547 · Cited by 42
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
Identification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Self-citationGalán‐Rioja, M. Á., González‐Mohíno, F., Poole, D. C., & González‐Ravé, J. M. (2020) · Sports Medicine · doi:10.1007/s40279-020-01314-8 · Cited by 144
Iannetta, D., de Almeida Azevedo, R., Keir, D. A., & Murias, J. M. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00508.2019 · Cited by 109
Self-citationA “Step–Ramp–Step” Protocol to Identify the Maximal Metabolic Steady State
IANNETTA, D., INGLIS, E. C., POGLIAGHI, S., MURIAS, J. M., & KEIR, D. A. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002343 · Cited by 84
Self-citationA Simple Method to Quantify the V˙O2 Mean Response Time of Ramp-Incremental Exercise
IANNETTA, D., MURIAS, J. M., & KEIR, D. A. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001880 · Cited by 78
Self-citationIannetta, D., Ingram, C. P., Keir, D. A., & Murias, J. M. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002831 · Cited by 74
Self-citationBioenergetics of the VO2 slow component between exercise intensity domains
Colosio, A. L., Caen, K., Bourgois, J., Boone, J., & Pogliaghi, S. (2020) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-020-02437-7 · Cited by 61
Self-citationGonzales, T. I., Westgate, K., Strain, T., Hollidge, S., Jeon, J., Christensen, D. L., Jensen, J., Wareham, N. J., & Brage, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-94768-3 · Cited by 59
Yogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
The Respiratory Compensation Point: Mechanisms and Relation to the Maximal Metabolic Steady State
Keir, D. A., Pogliaghi, S., Inglis, E. C., Murias, J. M., & Iannetta, D. (2024) · Sports Medicine · doi:10.1007/s40279-024-02084-3 · Cited by 43
Self-citationCaen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
Critical Power and Maximal Lactate Steady State in Cycling: “Watts” the Difference?
Caen, K., Poole, D. C., Vanhatalo, A., & JONES, A. M. (2024) · Sports Medicine · doi:10.1007/s40279-024-02075-4 · Cited by 35
BROXTERMAN, R. M., CRAIG, J. C., & RICHARDSON, R. S. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001699 · Cited by 34
Time to exhaustion during cycling is not well predicted by critical power calculations
Pallarés, J. G., Lillo-Beviá, J. R., Morán‐Navarro, R., Cerezuela‐Espejo, V., & Mora‐Rodríguez, R. (2020) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2019-0637 · Cited by 30
A Single Test Protocol to Establish the Full Spectrum of Exercise Intensity Prescription
Iannetta, D., Mackie, M. Z., Keir, D. A., & Murias, J. M. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003249 · Cited by 30
Self-citationTeso, M., Colosio, A. L., & Pogliaghi, S. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002835 · Cited by 27
Self-citationGildea, N., McDermott, A., Rocha, J., O'Shea, D. B., Green, S., & Egaña, M. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00952.2020 · Cited by 25
van Rassel, C. R., Ajayi, O. O., Sales, K. M., Azevedo, R. D. A., Murias, J. M., & MacInnis, M. J. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003066 · Cited by 22
Self-citationInglis, E. C., Iannetta, D., Keir, D. A., & Murias, J. M. (2020) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0046 · Cited by 21
Self-citationBarranco‐Gil, D., Gil-Cabrera, J., Valenzuela, P. L., Alejo, L. B., Montalvo‐Pérez, A., Talavera, E., Moral-González, S., & Lucía, A. (2020) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0402 · Cited by 21
Kontro, H., Bertagnolli, C., Murias, J. M., & MacInnis, M. J. (2022) · Experimental Physiology · doi:10.1113/ep090642 · Cited by 20
Self-citationFat Oxidation Kinetics Is Related to Muscle Deoxygenation Kinetics During Exercise
Zurbuchen, A., Lanzi, S., Voirol, L., Trindade, C. B., Gojanovic, B., Kayser, B., Bourdillon, N., Chenevière, X., & Malatesta, D. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00571 · Cited by 20
Mackie, M. Z., Iannetta, D., Keir, D. A., & Murias, J. M. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003362 · Cited by 20
Self-citationRelationship between Exhaled Aerosol and Carbon Dioxide Emission Across Respiratory Activities
Moseley, B., Archer, J., Orton, C. M., Symons, H. E., Watson, N. A., Saccente‐Kennedy, B., Philip, K. E. J., Hull, J. H., Costello, D. A. E., Calder, J. D. F., et al. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.4c01717 · Cited by 19
Time to Exhaustion at the Respiratory Compensation Point in Recreational Cyclists
Moral-González, S., González-Sánchez, J., Valenzuela, P. L., García-Merino, S., Barbado, C., Lucía, A., Foster, C., & Barranco‐Gil, D. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176352 · Cited by 17
Fleitas‐Paniagua, P. R., Marinari, G., Rasica, L., Rogers, B., & Murias, J. M. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003412 · Cited by 16
Self-citationFleitas‐Paniagua, P. R., Azevedo, R. D. A., Trpcic, M., Murias, J. M., & Rogers, B. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004597 · Cited by 15
Self-citationRocha, J., Gildea, N., O'Shea, D. B., Green, S., & Egaña, M. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00344.2019 · Cited by 14
Dissociation between exercise intensity thresholds: mechanistic insights from supine exercise
Goulding, R. P., Marwood, S., Lei, T., Okushima, D., Poole, D. C., Barstow, T. J., Kondo, N., & Koga, S. (2021) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00096.2021 · Cited by 13
SITKO, S., Cirer-Sastre, R., Corbi, F., & LÓPEZ-LAVAL, I. (2022) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.21.12285-6 · Cited by 13
Colosio, A. L., Teso, M., & Pogliaghi, S. (2020) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2019-0981 · Cited by 11
Self-citationCritical Power and Respiratory Compensation Point Are Not Equivalent in Patients with COPD
Tiller, N. B., Pórszász, J., Casaburi, R. H., Rossiter, H. B., & Ferguson, C. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003124 · Cited by 11
Can We Accurately Predict Critical Power and W′ from a Single Ramp Incremental Exercise Test?
Caen, K., Bourgois, J., Stuer, L., MERMANS, V., & BOONE, J. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003171 · Cited by 11
Iannetta, D., Marinari, G., & Murias, J. M. (2023) · Journal of Sports Sciences · doi:10.1080/02640414.2023.2259206 · Cited by 10
Self-citationKominami, K., Imahashi, K., Katsuragawa, T., Murakami, M., & Akino, M. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.769387 · Cited by 10
Mckee, J. R., Marco, K. D., Girard, O., Peiffer, J. J., & Scott, B. R. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2457863 · Cited by 8
Micheli, L., Teso, M., Guluzade, N. A., Rizzo, M., Marini, C. F., Lucertini, F., Keir, D. A., & Pogliaghi, S. (2024) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2024-0042 · Cited by 8
Self-citationGildea, N., Rocha, J., O'Shea, D. B., Green, S., & Egaña, M. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04518-y · Cited by 8
Keir, D. A., Pogliaghi, S., & Murias, J. M. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001851 · Cited by 7
Self-citationDetermining the Upper Limit of the Metabolic Steady State
Marwood, S., Goulding, R. P., & Roche, D. M. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001819 · Cited by 7
A comparative analysis of critical power models in elite road cyclists
Clark, B., & Macdermid, P. W. (2021) · Current Research in Physiology · doi:10.1016/j.crphys.2021.05.001 · Cited by 7
Vasquez-Bonilla, A. A., González-Custodio, A., Timón, R., & Olcina, G. J. (2022) · Sport Sciences for Health · doi:10.1007/s11332-022-00985-2 · Cited by 6
Gildea, N., McDermott, A., Rocha, J., Crognale, D., Nevin, A., O'Shea, D. B., Green, S., & Egaña, M. (2022) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00148.2022 · Cited by 6
Easy Prediction of the Maximal Lactate Steady-State in Young and Older Men and Women
Pogliaghi, S., Teso, M., Ferrari, L., Boone, J., Murias, J. M., & Colosio, A. L. (2023) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2023.68 · Cited by 6
Self-citationKeir, D. A., Pogliaghi, S., & Murias, J. M. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001820 · Cited by 6
Self-citationMicheli, L., Lucertini, F., Grossi, T., Pogliaghi, S., Keir, D. A., & Marini, C. F. (2025) · PeerJ · doi:10.7717/peerj.19060 · Cited by 5
Self-citationThe Question Should Be: Is HHbBP Equivalent to RCP?
Boone, J., Caen, K., Vermeire, K., Bourgois, G., & Bourgois, J. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001850 · Cited by 5
Faricier, R., Keltz, R. R., Hartley, T., MACKAY, N., Murias, J. M., Huitema, A., McKelvie, R. S., Suskin, N., & Keir, D. A. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003684 · Cited by 5
Self-citationVigorous intensity heart rate-clamp exercise does not elicit recommended oxygen consumption rates
Mitchinson, C. J., Gustave, D., Succi, P. J., Benitez, B., Kwak, M., & Bergstrom, H. C. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05665-2 · Cited by 4
Metabolic and Perceptual Responses to Constant Heart Rate Exercise at Vigorous Intensities in Women
Gustave, D., Mitchinson, C. J., Succi, P. J., Benitez, B., Kwak, M., Lanphere, K. R., Clasey, J. L., & Bergstrom, H. C. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003381 · Cited by 3
Rogers, B., Murias, J. M., & Fleitas‐Paniagua, P. R. (2025) · PubMed · doi:10.1519/jsc.0000000000005196 · Cited by 3
Self-citationMarwood, S., Simpson, L. P., Wilkerson, D. P., Jones, A. M., & Goulding, R. P. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.12291 · Cited by 3
Caen, K. (2021) · Ghent University Academic Bibliography (Ghent University) · Cited by 3
Priego‐Quesada, J. I., MacKay, N., Adejuwon, D. C., & Keir, D. A. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae8a10 · Cited by 2
Self-citationZubac, D., Ivančev, V., Martin, V., Iacono, A. D., Meulenberg, C. J. W., & McDonnell, A. C. (2022) · PeerJ · doi:10.7717/peerj.13199 · Cited by 2
Gennaro, S. D., Panascì, M., Gallo, G., Filipas, L., Ruggeri, P., & Faelli, E. L. (2025) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0064 · Cited by 2
Measuring muscle oxygenation in endurance sports with wearable nirs - from validation to application
Yogev, A. (2023) · cIRcle (University of British Columbia) · doi:10.14288/1.0431178 · Cited by 1
Considerations for the Measurement of Respiratory Compensation Point and Critical Power in COPD
Keir, D. A., & Murias, J. M. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003210 · Cited by 1
Self-citationIndexes of Fat Oxidation from Ramp vs. Graded Incremental Protocols in Postmenopausal Women
Teso, M., Ferrari, L., Colosio, A. L., & Pogliaghi, S. (2025) · Physiologia · doi:10.3390/physiologia5010003
Self-citationACEITUNO, H. F., Cano-Cappellacci, M. A., Opazo‐Díaz, E., Amador-Castro, P., Yhuma-Laiz, M. J., & Ramírez-Jiménez, M. (2025) · Sport Sciences for Health · doi:10.1007/s11332-025-01563-y
Sendra‐Pérez, C., Carrión‐González, C., Wessling-Intriago, P., Marzano‐Felisatti, J. M., Priego‐Quesada, J. I., & Aparicio, I. (2026) · Applied Sciences · doi:10.3390/app16105009
Snell, E. R., Succi, P. J., Mitchinson, C. J., Benitez, B., Kwak, M., Kuhn, A. N., & Bergstrom, H. C. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10040448
The Effect of Intensity Prescription on Individual Responses to Exercise
Meyler, S. (2024) · University of Hertfordshire Research Archive (University of Hertfordshire)
Yang, X., & Yi, S. (2026) · Clinical and Experimental Gastroenterology · doi:10.2147/ceg.s572842
Kontro, H., & MacInnis, M. J. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06432-1
A critical appraisal of methods to determine the Maximal Metabolic Steady State in cycling
Wong, S. (2024) · Kent Academic Repository (University of Kent) · doi:10.22024/unikent/01.02.104738
Kogoj, T. (2024) · Repository of the University of Primorsk (University of Primorska)
Hesse, A. (2023) · University of Minnesota Digital Conservancy (University of Minnesota)
Novel Wearable Technology Methods to Guide and Monitor Endurance Training
van Rassel, C. R. (2025) · doi:10.11575/prism/49133
The Effects of Simulated Altitude on Maximal and Submaximal Exercise
Beever, A. T. (2021) · doi:10.11575/prism/39840
Abe, M., Ushio, K., Tsubokawa, M., Fukuhara, K., Iwamoto, Y., Iwaki, D., Nakashima, Y., Nakamura, T., & Mikami, Y. (2025) · Medical Sciences · doi:10.3390/medsci13030192
Laboratory, H. P. (2018) · doi:10.11575/prism/39062
The Effects of Nasal Breathing on Aspects of Athletic Performance
Stewart, N. T. H. (2023) · Research Commons (University of Waikato)
CARDIORESPIRATORY AND METABOLIC RESPONSE TO DIFFERENT SINUSOIDAL WORK RATES
Shokohyar, S. (2021) · Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) · doi:10.13130/shokohyar-sheida_phd2021-02-23
Metadata
- Authors
- KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M.
- Affiliations
- University Health Network (CA)
- University of Verona (IT)
- University of Calgary (CA)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-11
- Volume
- 50
- Issue
- 11
- Pages
- 2375-2378
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2888031567
- Semantic Scholar
- 1114728aba7003144614b1fb174226ac94a10bf4
- Cited by
- 65
- References
- 13
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 8 · 2023: 9 · 2022: 8 · 2021: 7 · 2020: 11 · 2019: 8 · 2018: 1
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Keywords
- respiratory compensation point, critical power, maximal lactate steady state, oxygen consumption, near-infrared spectroscopy, muscle oxygenation, endurance exercise, high-energy phosphates, substrate-level phosphorylation, exercise exhaustion
- MeSH terms
- Energy Metabolism, Hemoglobins, Humans, Myoglobin, Oxygen Consumption, Anaerobic Threshold, Respiratory Mechanics, Muscle, Skeletal, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.