Incidence of V˙O2max Responders to Personalized versus Standardized Exercise Prescription
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Introduction: Despite knowledge of cardiorespiratory fitness (CRF) training responders and nonresponders, it is not well understood how the exercise intensity prescription affects the incidence of response. The purpose of this study was to determine CRF training responsiveness based on cohort-specific technical error after 12 wk of standardized or individually prescribed exercise and the use of a verification protocol to confirm maximal oxygen uptake (V˙O 2 max). Methods: Sedentary adult participants (9 men, 30 women; 48.2 ± 12.2 yr) completed exercise training on 3 d·wk−1 for 12 wk, with exercise intensity prescribed based on standardized methods using heart rate reserve or an individualized approach using ventilatory thresholds. A verification protocol was used at baseline and 12 wk to confirm the identification of a true V˙O 2 max and subsequent relative percent changes to quantify CRF training responsiveness. A cohort-specific technical error (4.7%) was used as a threshold to identify incidence of response. Results: Relative V˙O 2 max significantly increased (P < 0.05) from 24.3 ± 4.6 to 26.0 ± 4.2 and 29.2 ± 7.5 to 32.8 ± 8.6 mL·kg−1·min−1 for the standardized and individualized groups, respectively. Absolute V˙O 2 max significantly increased (P < 0.05) from 2.0 ± 0.6 to 2.2 ± 0.6 and 2.4 ± 0.8 to 2.6 ± 0.9 L·min−1 for the standardized and individualized groups, respectively. A significant difference in responsiveness was found between the individualized and standardized groups with 100% and 60% of participants categorized as responders, respectively. Conclusions: A threshold model for exercise intensity prescription had a greater effect on the incidence of CRF training response compared with a standardized approach using heart rate reserve. The use of thresholds for intensity markers accounts for individual metabolic characteristics and should be considered as a viable and practical method to prescribe exercise intensity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kodama, S. (2009) · JAMA · doi:10.1001/jama.2009.681 · Cited by 3,035
Individual differences in response to regular physical activity
BOUCHARD, C., & RANKINEN, T. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106001-00013 · Cited by 939
Bouchard, C., An, P., Rice, T., Skinner, J. S., Wilmore, J. H., Gagnon, J., Pérusse, L., Leon, A. S., & Rao, D. C. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.3.1003 · Cited by 875
Exercise and the Cardiovascular System: Clinical Science and Cardiovascular Outcomes
Lavie, C. J., Arena, R., Swift, D. L., Johannsen, N. M., Sui, X., Lee, D.-C., Earnest, C. P., Church, T. S., O’Keefe, J. H., Milani, R. V., et al. (2015) · Circulation Research · doi:10.1161/circresaha.117.305205 · Cited by 782
Measurement of the maximum oxygen uptake V̇ o 2max : V̇ o 2peak is no longer acceptable
Poole, D. C., & Jones, A. M. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01063.2016 · Cited by 533
Adverse metabolic response to regular exercise: is it a rare or common occurrence?
Bouchard, C., Blair, S. N., Church, T. S., Earnest, C. P., Hagberg, J. M., Häkkinen, K., Jenkins, N. T., Karavirta, L., Kraus, W. E., Leon, A. S., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037887 · Cited by 404
Montero, D., & Lundby, C. (2017) · The Journal of Physiology · doi:10.1113/jp273480 · Cited by 384
Mann, T. N., Lamberts, R. P., & Lambert, M. I. (2014) · Sports Medicine · doi:10.1007/s40279-014-0197-3 · Cited by 379
Ross, R., de Lannoy, L., & Stotz, P. J. (2015) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2015.07.024 · Cited by 224
Vollaard, N. B. J., Constantin-Teodosiu, D., Fredriksson, K., Rooyackers, O., Jansson, E., Greenhaff, P. L., Timmons, J. A., & Sundberg, C. J. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91453.2008 · Cited by 205
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Hansen, D., Abreu, A., Ambrosetti, M., Cornelissen, V., Gevaert, A., Kemps, H., Laukkanen, J. A., Pedretti, R., Simonenko, M., Wilhelm, M., et al. (2022) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwab007 · Cited by 321
Meyler, S., Bottoms, L., & Muniz‐Pumares, D. (2021) · Experimental Physiology · doi:10.1113/ep089565 · Cited by 67
Bossi, A. H., Naumann, U., Passfield, L., & Hopker, J. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05340-y · Cited by 13
“Moreover, conflicting evidence exists as to whether certain intensity prescription methods could minimise adaptive variability (Weatherwax et al. 2019; McLel-lan and Skinner 1981; Preobrazenski et al. 2019).”
BackgroundMethodResultInfluential
Metadata
- Authors
- WEATHERWAX, R. M., HARRIS, N. K., KILDING, A. E., & DALLECK, L. C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2019-04
- Volume
- 51
- Issue
- 4
- Pages
- 681-691
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2900164501
- Cited by
- 101
- References
- 17
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidence of V˙O2max Responders to Personalized versus Standardized Exercise Prescription. https://app.cochat.ai/papers/10.1249/mss.0000000000001842
- The paper
- WEATHERWAX, R. M., HARRIS, N. K., KILDING, A. E., & DALLECK, L. C. (2019). Incidence of V˙O2max Responders to Personalized versus Standardized Exercise Prescription. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.