Validation of the GENEA Accelerometer
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Perkins, N. J., & Schisterman, E. F. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj063 · Cited by 1,759
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring Physical Activity and Energy Expenditure
Kemper, H. C. G., & Saris, W. H. M. (1996) · Cited by 554
Prevalence of obesity in Great Britain
Rennie, K. L., & Jebb, S. A. (2005) · Obesity Reviews · doi:10.1111/j.1467-789x.2005.00164.x · Cited by 395
Validation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Calibration and Evaluation of an Objective Measure of Physical Activity in Preschool Children
Sirard, J. R., Trost, S. G., Pfeiffer, K. A., Dowda, M., & Pate, R. R. (2005) · Journal of Physical Activity and Health · doi:10.1123/jpah.2.3.345 · Cited by 311
Measurement of Human Daily Physical Activity
Zhang, K., Werner, P., Sun, M., Pi‐Sunyer, F. X., & Boozer, C. N. (2003) · Obesity Research · doi:10.1038/oby.2003.7 · Cited by 306
Technical Reliability Assessment of Three Accelerometer Models in a Mechanical Setup
ESLIGER, D. W., & TREMBLAY, M. S. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000239394.55461.08 · Cited by 244
Self-citationEvidence-informed physical activity guidelines for Canadian adults.
Warburton, D. E. R., Katzmarzyk, P. T., Rhodes, R. E., & Shephard, R. J. (2007) · PubMed · Cited by 201
Comparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Absolute versus relative intensity of physical activity in a dose-response context
SHEPHARD, R. J. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106001-00008 · Cited by 174
Technical reliability of the CSA activity monitor: The EarlyBird Study
Metcalf, B. S., Curnow, J. S. H., Evans, C., Voss, L. D., & Wilkin, T. J. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200209000-00022 · Cited by 142
Esliger, D. W., & Tremblay, M. S. (2007) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-107 · Cited by 131
Self-citationTechnical Variability of the RT3 Accelerometer
POWELL, S. M., JONES, D. I., & ROWLANDS, A. V. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089341.68754.ba · Cited by 109
Self-citationBrage, S., Brage, N., Wedderkopp, N., & Froberg, K. (2003) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0702_4 · Cited by 93
Technical Reliability Assessment of the Actigraph GT1M Accelerometer
Silva, P., Mota, J. A. P. S., Esliger, D., & Welk, G. J. (2010) · Measurement in Physical Education and Exercise Science · doi:10.1080/10913671003715524 · Cited by 74
Self-citationJago, R., Zakeri, I., Baranowski, T., & Watson, K. (2007) · Journal of Sports Sciences · doi:10.1080/02640410600908027 · Cited by 71
Reproducibility of a Triaxial Seismic Accelerometer (DynaPort)
VAN HEES, V. T., SLOOTMAKER, S. M., DE GROOT, G., VAN MECHELEN, W., & VAN LUMMEL, R. C. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818ff636 · Cited by 70
Ware, L. J., Hurling, R., Bataveljic, O., Fairley, B. W., Hurst, T. L., Murray, P., Rennie, K. L., Tomkins, C. E., Finn, A., Cobain, M. R., et al. (2008) · Journal of Medical Internet Research · doi:10.2196/jmir.1108 · Cited by 65
Self-citationCalibration of the RT3 Accelerometer for Ambulation and Nonambulation in Children
CHU, E. Y. W., McMANUS, A. M., & YU, C. C. W. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318148436c · Cited by 65
Is Fast Walking an Adequate Aerobic Training Stimulus for 30- to 69-Year-Old Men and Women?
Porcari, J. P., McCarron, R., KLINE, G. M., Freedson, P. S., Ward, A., Ross, J. A., & Rippe, J. M. (1987) · The Physician and Sportsmedicine · doi:10.1080/00913847.1987.11709285 · Cited by 50
Interunit and Intraunit Reliability of the RT3 Triaxial Accelerometer
Krasnoff, J. B., Kohn, M. A., Choy, F. K. K., Doyle, J., Johansen, K., & Painter, P. L. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.4.527 · Cited by 46
Adaptive control for a multi-axis hydraulic test rig
Gizatullin, A. O., & Edge, K. A. (2007) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1243/09596518jsce314 · Cited by 46
Calibration of the Biotrainer Pro Activity Monitor in Children
Welk, G. J., Eisenmann, J. C., Schaben, J. A., Trost, S. G., & Dale, D. (2007) · Pediatric Exercise Science · doi:10.1123/pes.19.2.145 · Cited by 26
Møller, N. C., Korsholm, L., Kristensen, P. L., Andersen, L. B., Wedderkopp, N., & Froberg, K. (2008) · BMC Medical Research Methodology · doi:10.1186/1471-2288-8-19 · Cited by 23
Declining left-handedness in Victorian England seen in the films of Mitchell and Kenyon
McManus, I. C., & Hartigan, A. (2007) · Current Biology · doi:10.1016/j.cub.2007.07.008 · Cited by 18
Cited by
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
“Previous studies have suggested that a wristworn raw accelerometer accurately assesses overall PA among both children and adults (8,23); however, a wrist-mounted raw accelerometer may present challenges when trying to accurately identify different PA intensity thresholds (28).”
BackgroundMethodResultInfluentialStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
“See Hildebrand et al. (15) for a discussion on the subtle differences between SVMgs and ENMO.”
Metadata
- Authors
- ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
- Affiliations
- University of Exeter (GB)
- Unilever (United Kingdom) (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2011-06
- Volume
- 43
- Issue
- 6
- Pages
- 1085-1093
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084103512
- Cited by
- 625
- References
- 32
- Citations by year
- 2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc-nd
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
- MeSH terms
- Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.