Non-Invasive Magnetocardiography for the Early Diagnosis of Coronary Artery Disease in Patients Presenting With Acute Chest Pain
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurate identification of patients with acute coronary syndrome (ACS) is often difficult especially when an electrocardiogram (ECG) does not show typical elevation of ST segment. The aim of the present study was therefore to evaluate the efficacy of magnetocardiography (MCG) for diagnosis of ACS in patients with acute chest pain presenting without ST segment elevation. METHODS AND RESULTS: In the present retrospective study 364 patients with the suspected ACS without ST segment elevation were selected. Significant coronary artery disease (CAD) was defined as a stenosis > or =50% in at least one of 16 segments of the 3 major coronary arteries and their branches. The MCG recordings were obtained at resting state using a 64-channel MCG system in a magnetically shielded room. The patients were classified on the basis of the probability distribution. The presence of significant CAD was identified with a sensitivity of 84.0% and a specificity of 85.0%, compared to 44.7% and 89.8% on ECG. In the subgroup of patients without specific findings on ECG or biomarker test, MCG had a sensitivity of 73.5% and a specificity of 82.3%. CONCLUSIONS: MCG was acceptably sensitive and specific in identifying patients with ACS even in the absence of specific findings on ECG and positive biomarker tests. Thus, MCG seems beneficial for the early triage of patients with acute chest pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, MCG is expected to be more sensitive and can be especially helpful for early diagnosis of numerous heart diseases (2–6) and monitoring the fetal heart health (7–9).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [2]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995 · cited 1×
“Unstable angina, n (%) 128 (54) 28 (22) –”
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123 · cited 1×
“UA was defined as angina pectoris or an equivalent type of ischemic discomfort with ≥1 of the following 3 features and negative results of cardiac biomarker tests (such as troponin T and creatine kinase-MB): (1) prolonged (usually ≥20 min) angina occurring at rest; (2) newonset (within 1 month) angina of Canadian Card…”
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00889-5 · Cited by 963
Bertrand, M. (2002) · European Heart Journal · doi:10.1053/euhj.2002.3385 · Cited by 900
Clinical Electrocardiography: A Simplified Approach
(2006) · Elsevier eBooks · doi:10.1016/b0-323-04038-1/x5001-x · Cited by 273
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Magnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109
Self-citationTolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006) · Cardiology · doi:10.1159/000093490 · Cited by 78
Engblom, H., Foster, J. E., Martin, T. N., Groenning, B. A., Pahlm, O., Dargie, H. J., Wagner, G. S., & Arheden, H. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.10.041 · Cited by 65
Research works printed but not linked: 3
- 1. Battler A. European heart survey of acute coronary syndromes. Eur Heart J 2002; 23: 1190 - 1201.
- 5. Stroink G, Moshage W, Achenbach S. Cardiomagnetism. In : Andrä W, Nowak H, editors. Magnetism in Medicine. Wiley-VCH, Berlin: 1998; 136 - 189.
- 11. tion in detection of myocardial ischemia in exercise magnetocardiography. Basic Res Cardiol 2002; 97: 88 - 96.
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
“Kwon and co-workers conducted a retrospective study of 364 patients with suspected ACS without ST-segment elevation [47].”
BackgroundPena, M. E., Pearson, C. L., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. B. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 70
Houston, M. C. (2018) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/1753944717743920 · Cited by 71
Magnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 68
“(44) Algorithm of weighted maximum of posteriori as a function of five prespecified MCG variables, T_FMA, T_FMA—R_FMA, TT_CAMx, TT_CAMx—R_FMA, and TT_CMD ACS and non-ACS CAD/Patients admitted to hospital with suspected ACS diagnosed as CAD with angiographically proven ≥50% stenosis of a vessel (237) Subgroup of patien…”
BackgroundGirão, H., & Pereira, P. (2003) · PubMed · Cited by 54
Huang, X., Chen, P., Tang, F., & Hua, N. (2021) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-200905 · Cited by 33
“…study of their group showed a sensitivity of 84.0% and a specificity of 85.0% of these parameters to identify CAD patients(a stenosis (cid:2) 50% in at least one of 16 segments of the 3 major coronary arteries and their branches), when ECG had a sensitivity of 44.7% and a specificity of 89.8% [10].”
InfluentialSteinisch, M., Torke, P. R., Haueisen, J., Hailer, B., Grönemeyer, D. H. W., Leeuwen, P. V., & Comani, S. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.11.014 · Cited by 29
“In contrast to ECG signals, MCG recordings are unaltered by the tissues surrounding the heart and are not affected by the problems related to bad lead contact, hence providing more ry artery disease in patients studied with magnetocardiography: 2012), http://dx.doi.org/10.1016/j.compbiomed.2012.11.014i Table 1 Patient…”
MethodInfluentialAgarwal, R., Saini, A., Alyousef, T., & Umscheid, C. A. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2012.00538.x · Cited by 28
Wang, Y., Zhao, Z., Chai, Z., Fang, J., & Chen, M. (2023) · The FASEB Journal · doi:10.1096/fj.202300201rr · Cited by 27
Han, X., Xue, X., Yang, Y., Liang, X., Gao, Y., Xiang, M., Sun, J., & Ning, X. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ace497 · Cited by 25
Wu, Y., Lin, L. C., Tseng, W., Liu, Y., Kao, H.-L., Lin, M. S., Huang, H. C., Wang, S. Y., Horng, H. E., Yang, H. C., et al. (2014) · PubMed Central · Cited by 24
An Integrated Maximum Current Density Approach for Noninvasive Detection of Myocardial Infarction
Zhao, C., Jiang, S., Wu, Y., Zhu, J., Zhou, D., Hailer, B., Grönemeyer, D. H. W., & Leeuwen, P. V. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2649570 · Cited by 22
“0% [11].”
Han, X., Pang, J., Xu, D., Xie, F., Li, Y., Xiang, M., Sun, J., Chen, Y., & Ning, X. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108764 · Cited by 21
Wu, Y.-W., Lee, C.-M., Liu, Y.-B., Wang, S.-S., Huang, H.-C., Tseng, W.-K., Jui, H.-Y., Wang, S.-Y., Horng, H.-E., Yang, H.-C., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-12-1170 · Cited by 18
“Diabetes mellitus 18 (35) 5 (21) 10 (38) NS”
Sorbo, A. R., Lombardi, G., La Brocca, L., Guida, G., Fenici, R., & Brisinda, D. (2018) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12526 · Cited by 18
“…et al., 2007; Brockmeier et al., 1997; Fenici, Brisinda, Meloni, Sternickel, & Fenici, 2005; Hailer, Van Leeuwen et al., 2005; Kandori et al., 2010; Kwon et al., 2010; Kwong et al., 2013; Leithäuser et al., 2013; Li et al., 2015; Lim et al., 2007; Ogata et al., 2009; Park & Hill, 2005; Park et…”
Diagnostic Value of Magnetocardiography to Detect Abnormal Myocardial Perfusion: A Pilot Study
Zhang, H., Ma, Z., Mi, H., Jiao, J., Dong, W., Yang, S., Liu, L., Zhou, S., Feng, L., Zhao, X., et al. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2510379 · Cited by 18
“Traditionally, MCG assessments required magnetically shielded rooms to mitigate environmental magnetic noise [33–35].”
BackgroundHer, A., & Park, J. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1305 · Cited by 18
Gapelyuk, A., Schirdewan, A., Fischer, R., & Wessel, N. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/10/004 · Cited by 16
Ramesh, R., Senthilnathan, S., Satheesh, S., Swain, P. P., Patel, R., Pillai, A. A., Katholil, G., & Selvaraj, R. J. (2019) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12715 · Cited by 14
“These parameters of MCG showed sensi‐ tivity of 84% and specificity of 85% in diagnosing coronary ischemia in patients presenting with acute onset chest pain with normal ECG (Kwon et al., 2010).”
BackgroundMethodA synthetic optically pumped gradiometer for magnetocardiography measurements*
Zhang, S., & Cao, N. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab7801 · Cited by 14
Diagnostic accuracy of the magnetocardiograph for patients with suspected acute coronary syndrome
Goodacre, S., Walters, S. J., Qayyum, H., Coffey, F., Carlton, E., Coats, T., Glazebrook, W., & Unitt, L. (2021) · Emergency Medicine Journal · doi:10.1136/emermed-2020-210396 · Cited by 13
Advances of magnetocardiography in application of adult and fetal cardiac diseases
Li, J., Shen, Y., Shen, C., Ning, X., & Xiang, M. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1522467 · Cited by 16
Closed-cycle cryocooled SQUID system with superconductive shield for biomagnetism
Yu, K. K., Lee, Y. H., Lee, S.-J., Shim, J. H., Hwang, S. M., Kim, J. M., Kwon, H., & Kim, K. (2014) · Superconductor Science and Technology · doi:10.1088/0953-2048/27/10/105007 · Cited by 13
Self-citationJian-Guo, C. U. I., Feng, T. I. A. N., Yu-Hao, M. I. A. O., Qin-Hua, J. I. N., Shi, Y., Li, L., Meng-Jun, S. H. E. N., Xie, X., ZHANG, S.-L., & Chen, Y. (2024) · 老年心脏病学杂志:英文版 · doi:10.26599/1671-5411.2024.04.006 · Cited by 12
Bedside Magnetocardiography with a Scalar Sensor Array
Iwata, G. Z., Nguyen, C. T., Tharratt, K., Ruf, M., Reinhardt, T., Crivelli-Decker, J. E., Liddy, M. S. Z., Rugar, A. E., Lu, F., Aschbacher, K., et al. (2024) · Sensors · doi:10.3390/s24165402 · Cited by 12
“MCG has already been utilized for diagnosis of ischemic heart conditions, where blood vessels may narrow due to plaque buildup, resulting in an inadequate and non-uniform distribution of blood and oxygen in the heart (i.e., coronary artery disease) [4,5].”
MethodChang, Y., Wu, C., Lin, C., Wu, Y., Yang, Y., Chang, T., Jiang, Y., & Chuang, L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0133192 · Cited by 9
Noninvasively diagnosing coronary artery disease with 61-channel MCG data
Chen, T., Zhao, C., Jiang, S., Leeuwen, P. V., & Grönemeyer, D. H. W. (2014) · Chinese Science Bulletin · doi:10.1007/s11434-014-0177-x · Cited by 8
Liang, S., Qi, J., He, J., Jia, Y., Wang, A., Zhao, T., Wei, C., Jiao, H., Feng, L., & Cheng, H. (2025) · Biosensors · doi:10.3390/bios15040243 · Cited by 7
“Some researchers have studied MCG using superconducting quantum interference devices due to the advantages of MCG [6,7].”
Caiani, G., Chiaramello, E., Ravazzani, P., & Fiocchi, S. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00198-1 · Cited by 7
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Magnetoionography enhances diagnostic accuracy of magnetocardiography in coronary artery disease
Dischl, D., Kranz, D. D., Bannasch, S., Gapelyuk, A., Landmesser, U., Park, J.-W., & Wessel, N. (2025) · Scientific Reports · doi:10.1038/s41598-025-14054-4 · Cited by 6
Greedy Optimization of Sensor Array Geometry for Magnetocardiographic Source Localization
Veen, B. D. V., Stenroos, M., & Wakai, R. T. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3524374 · Cited by 6
“Manyimportant clinical applications of MCG, such as diagnosis of coronary artery disease [15], [16] and risk assessment for ventricular tachycardia [17], utilize sensor space analysis of magnetic field maps.”
Dou, S., Liu, X., Song, P., Cao, Y., Wen, T., Feng, R., & Han, B. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3584984 · Cited by 5
“Compared to electrocardiograms (ECG) signals, MCG signals are less susceptible to interference from the lungs, chest wall, and other media due to the characteristics of magnetic signals [10], [11].”
He, W., Zeng, L., Xie, N.-S., Liu, H., Cui, W.-M., Wang, Y., Zhang, Z., Ye, G.-L., Qin, Z.-Y., Guo, Z., et al. (2025) · Frontiers in Medical Technology · doi:10.3389/fmedt.2025.1611046 · Cited by 5
Dawson, R., O’Dwyer, C., Mrozowski, M. S., Ingleby, S. J., Griffin, P. F., & Riis, E. (2024) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.3002678 · Cited by 5
Chaikovsky, I. A., Primin, M., Владимирович, Н. И., & Будник, М. М. (2012) · InTech eBooks · doi:10.5772/30122 · Cited by 4
“Recent studies has shown significant potential of MCG in diagnosis of myocardial ischemia, although analysis of MCG-generated data is not standardized yet (Hailer et al, 2005; Kwon et al, 2010; Chaikovsky et al, 2011).”
BackgroundMa, Z., Xu, F., Yang, S., Zhang, H., Liu, L., Zhou, S., Feng, L., Tu, C., Song, X., & Zhang, H. (2025) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2025.154085 · Cited by 2
Будник, М. М., Sosnytskyy, V., Voitovych, I., Maiko, V., Minov, Y. D., Sutkovyi, P., Zakorchenyi, O., Ryzhenko, T., & Budnyk, V. (2011) · IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications (IDAACS) · doi:10.1109/idaacs.2011.6072717 · Cited by 2
Bioelectric and biomagnetic measurements are differentially sensitive to spiral currents
Haueisen, J., Dietzel, A., Liehr, M., Weiser, T., Elsarnagawy, T., & Bellemann, M. E. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2011.104 · Cited by 2
Yang, F., & PATTERSON, R. P. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.04.073 · Cited by 2
Chen, J., Ye, C., Sun, L., Xiao, Q., Wang, L., & Niu, Y. (2024) · Academic Conference of China Instrument and Control Society (ACCIS) · doi:10.1109/accis62068.2024.10948626 · Cited by 1
Houston, M. C. (2019) · Alternative and Complementary Therapies · doi:10.1089/act.2019.29233.mho
Qiu, S., Tang, J., Tian, P., & Zhao, F. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3648094
“As a safe and noninvasive diagnostic tool, MCG has demonstrated potential in the early diagnosis of various cardiac diseases [3], [4], [5] and in prenatal evaluation of fetal cardiac health [6], [7].”
Establishment of magnetocardiogromics platform with reference range for normal magnetocardiogram
Guo, Y., Ma, J., Shen, H., Zhang, G., Zang, J., Zhang, Y., & Shen, C. (2025) · BMC Medical Imaging · doi:10.1186/s12880-025-02010-7
“Taking ischemic heart disease as an example, most related studies focus on the T wave or TT segments of the isomagnetic field due to their stable morphology in various phases of MCG [14, 15].”
Meta-analysis of magnetocardiography in diagnosing coronary artery disease and myocardial ischemia
Li, J., Yan, M., Xiang, M., & Ning, X. (2026) · Next research. · doi:10.1016/j.nexres.2026.101496 · Cited by 1
Li, J., Zhou, Y., Wang, R. T., Pang, J., Xiang, M., & Ning, X. (2026) · Balkan Medical Journal · doi:10.4274/balkanmedj.galenos.2026.2026-1-319
“19,20 Specificity is also limited: 85.0–91.1% for ECG, 90.5% for troponin-I, and 76.2% for echocardiography.”
InfluentialWang, Q., Zhang, L., & Huang, Z. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111658
Metadata
- Authors
- Kwon, H., Kim, K., Lee, Y.-H., Kim, J.-M., Yu, K. K., Chung, N., & Ko, Y.-G.
- Affiliations
- Korea Research Institute of Standards and Science (KR)
- Yonsei University (KR)
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2010
- Volume
- 74
- Issue
- 7
- Pages
- 1424-1430
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W1973244464
- Cited by
- 47
- References
- 23
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 6 · 2023: 4 · 2022: 1 · 2020: 4 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 3 · 2012: 3
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Keywords
- magnetocardiography, noninvasive cardiac imaging, acute coronary syndrome, coronary artery disease, acute chest pain, electrocardiogram, sensitivity and specificity, triage
- MeSH terms
- Adult, Aged, Chest Pain, Constriction, Pathologic, Coronary Artery Disease, Female, Humans, Male, Middle Aged, Retrospective Studies, Sensitivity and Specificity, Triage, Early Diagnosis, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.