Sensitivity to titanium. A cause of implant failure?
The DOI matches its Crossref record.
Abstract
Tissues from five patients who underwent revision operations for failed total hip replacements were found to contain large quantities of particulate titanium. In four cases this metal must have come from titanium alloy screws used to fix the acetabular component; in the fifth case it may also have originated from a titanium alloy femoral head. Monoclonal antibody labelling showed abundant macrophages and T-lymphocytes, in the absence of B-lymphocytes, suggesting sensitisation to titanium. Skin patch testing with dilute solutions of titanium salts gave negative results in all five patients. However, two of them had a positive skin test to a titanium-containing ointment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Metal Sensitivity in Patients with Orthopaedic Implants
Hallab, N., Merritt, K., & Jacobs, J. J. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200103000-00017 · Cited by 935
Biomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Widespread dissemination of metal debris from implants
Case, C., Langkamer, V., James, C., Palmer, M., Kemp, A., Heap, P., & Solomon, L. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b5.8083255 · Cited by 444
General review of titanium toxicity
Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019) · International Journal of Implant Dentistry · doi:10.1186/s40729-019-0162-x · Cited by 404
Are ceramic implants a viable alternative to titanium implants? A systematic literature review
Andreiotelli, M., Wenz, H. J., & Kohal, R. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01785.x · Cited by 380
Wear particles, periprosthetic osteolysis and the immune system
Goodman, S. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.035 · Cited by 340
“Periprosthetic tissues harvested from failed implants containing titanium screws and a cobalt chrome or titanium alloy femoral head articulating with a high density polyethylene socket demonstrated abundant macrophages containing titanium particles, numerous T lymphocytes but few B lymphocytes [18].”
BackgroundPeri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
Lymphocyte responses in patients with total hip arthroplasty
Hallab, N. J., Anderson, S., Stafford, T., Glant, T., & Jacobs, J. J. (2005) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.09.001 · Cited by 253
Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity
Fage, S. W., Muris, J., Jakobsen, S. S., & Thyssen, J. P. (2016) · Contact Dermatitis · doi:10.1111/cod.12565 · Cited by 222
Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants
Merritt, K., & Rodrigo, J. J. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199605000-00009 · Cited by 222
Goodman, S. B., Huie, P., Song, Y., Schurman, D. J., Maloney, W. J., Woolson, S. T., & Sibley, R. K. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b3.8158 · Cited by 217
Current Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
Spinal Implant Debris-Induced Osteolysis
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003) · Spine · doi:10.1097/00007632-200310151-00006 · Cited by 201
Revell, P. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0142 · Cited by 197
“These cells are seen as a diffuse infiltrate mixed with the macrophages and MNGCs and in aggregations having a perivascular distribution (Lalor et al. 1991; Lalor & Revell 1993b; Revell et al. 1997; Al-Saffar & Revell 1999; Revell 2006b), observations that have recently been confirmed by Willert (Davies et al.”
BackgroundSelf-citationBiological reaction to debris in relation to joint prostheses
Revell, P. A., AL-Saffar, N., & Kobayashi, A. (1997) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411971534304 · Cited by 195
Self-citationCadosch, D., Chan, E., Gautschi, O. P., & Filgueira, L. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32625 · Cited by 180
Size of metallic and polyethylene debris particles in failed cemented total hip replacements
Lee, J., Salvati, E., Betts, F., DiCarlo, E., Doty, S., & Bullough, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b3.1587882 · Cited by 176
Akagawa, Y., Hosokawa, R., Sato, Y., & Kamayama, K. (1998) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70031-9 · Cited by 173
Metal hypersensitivity testing in patients undergoing joint replacement: A systematic review
Granchi, D., Cenni, E., Giunti, A., & Baldini, N. (2012) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.94b8.28135 · Cited by 164
Metadata
- Authors
- Lalor, P., Revell, P., Gray, A., Wright, S., Railton, G., & Freeman, M.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1991-01
- Volume
- 73-B
- Issue
- 1
- Pages
- 25-28
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2135657116
- Cited by
- 393
- References
- 0
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.