Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee
Abstract
In six unloaded cadaver knees we used MRI to determine the shapes of the articular surfaces and their relative movements. These were confirmed by dissection. Medially, the femoral condyle in sagittal section is composed of the arcs of two circles and that of the tibia of two angled flats. The anterior facets articulate in extension. At about 20° the femur ‘rocks’ to articulate through the posterior facets. The medial femoral condyle does not move anteroposteriorly with flexion to 110°. Laterally, the femoral condyle is composed entirely, or almost entirely, of a single circular facet similar in radius and arc to the posterior medial facet. The tibia is roughly flat. The femur tends to roll backwards with flexion. The combination during flexion of no antero-posterior movement medially (i.e., sliding) and backward rolling (combined with sliding) laterally equates to internal rotation of the tibia around a medial axis with flexion. About 5° of this rotation may be obligatory from 0° to 10° flexion; thereafter little rotation occurs to at least 45°. Total rotation at 110° is about 20°, most if not all of which can be suppressed by applying external rotation to the tibia at 90°.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI
Hill, P. F., Vedi, V., Williams, A., Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821196 · Cited by 393
Self-citationTibial anatomy and functional axes
Yoshioka, Y., Siu, D. W., Scudamore, R. A., & Cooke, T. D. V. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070118 · Cited by 265
Kärrholm, J., Brandsson, S., & Freeman, M. A. R. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b8.10715 · Cited by 122
Self-citationAlbrecht, H. (1877) · Deutsche Zeitschrift für Chirurgie · doi:10.1007/bf02805278 · Cited by 12
Cited by
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
Self-citationTibiofemoral movement 2: the loaded and unloaded living knee studied by MRI
Hill, P. F., Vedi, V., Williams, A., Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821196 · Cited by 393
Self-citationJohal, P., Williams, A., Wragg, P., Hunt, D., & Gedroyc, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.008 · Cited by 360
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820027 · Cited by 305
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
"Profession": A Working Definition for Medical Educators
Cruess, S. R., Johnston, S., & Cruess, R. L. (2004) · Teaching and Learning in Medicine · doi:10.1207/s15328015tlm1601_15 · Cited by 298
Effect of posterior tibial slope on knee biomechanics during functional activity
Shelburne, K. B., Kim, H., Sterett, W. I., & Pandy, M. G. (2011) · Journal of Orthopaedic Research · doi:10.1002/jor.21242 · Cited by 293
Tibiofemoral movement 3: full flexion in the living knee studied by MRI
Nakagawa, S., Kadoya, Y., Todo, S., Kobayashi, A., Sakamoto, H., Freeman, M. A. R., & Yamano, Y. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821199 · Cited by 288
Self-citationBrandon, S. C. E., Miller, R. H., Thelen, D. G., & Deluzio, K. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.01.038 · Cited by 277
Murray, P. J., Alexander, J. W., Gold, J. E., Icenogle, K. D., Noble, P. C., & Lowe, W. R. (2010) · Arthroscopy · doi:10.1016/j.arthro.2009.07.014 · Cited by 48
The clinical epicondylar axis is not the functional flexion axis of the human knee
Mochizuki, T., Sato, T., Watanabe, S., Koga, Y., Blaha, J. D., Tanifuji, O., Yamagiwa, H., Endo, N., Kobayashi, K., & Omori, G. (2014) · Journal of Orthopaedic Science · doi:10.1007/s00776-014-0536-0 · Cited by 34
Facebook use among early-career veterinarians in Ontario, Canada (March to May 2010)
Weijs, C. A., Coe, J. B., Christofides, E., Muise, A., & Desmarais, S. (2013) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.242.8.1083 · Cited by 16
Otani, T., Kobayashi, Y., & Tanaka, M. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.07.015 · Cited by 7
An in vivo subject-specific 3D functional knee joint model using combined MR imaging
Chen, B., Lambrou, T., Offiah, A. C., Gondim Teixeira, P. A., Fry, M., & Todd-Pokropek, A. (2013) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-012-0801-7 · Cited by 7
Metadata
- Authors
- Iwaki, H., Pinskerova, V., & Freeman, M. A. R.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2000-11
- Volume
- 82-B
- Issue
- 8
- Pages
- 1189-1195
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2141614436
- Cited by
- 736
- References
- 4
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.