Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Open accessThe DOI matches its Crossref record; 156 of the 156 references it cites were found in a registry or an index.
Abstract
This document contains recommendations for terminology in mass spectrometry. Development of standard terms dates back to 1974 when the IUPAC Commission on Analytical Nomenclature issued recommendations on mass spectrometry terms and definitions. In 1978, the IUPAC Commission on Molecular Structure and Spectroscopy updated and extended the recommendations and made further recommendations regarding symbols, acronyms, and abbreviations. The IUPAC Physical Chemistry Division Commission on Molecular Structure and Spectroscopy’s Subcommittee on Mass Spectroscopy revised the recommended terms in 1991 and appended terms relating to vacuum technology. Some additional terms related to tandem mass spectrometry were added in 1993 and accelerator mass spectrometry in 1994. Owing to the rapid expansion of the field in the intervening years, particularly in mass spectrometry of biomolecules, a further revision of the recommendations has become necessary. This document contains a comprehensive revision of mass spectrometry terminology that represents the current consensus of the mass spectrometry community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
The Conservation of Orbital Symmetry
Woodward, R. B., & Hoffmann, R. (1969) · Angewandte Chemie International Edition in English · doi:10.1002/anie.196907811 · Cited by 4,090
Time-of-Flight Mass Spectrometer with Improved Resolution
Wiley, W. C., & McLaren, I. H. (1955) · Review of Scientific Instruments · doi:10.1063/1.1715212 · Cited by 3,678
Disintegration of water drops in an electric field
Taylor, G. I. (1964) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1964.0151 · Cited by 3,305
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Cited by
INTERPRETATION OF MASS SPECTRA
(1991) · Analytical Chemistry · doi:10.1021/ac00022a726 · Cited by 1,840
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
The Molecular Identification of Organic Compounds in the Atmosphere: State of the Art and Challenges
Nozière, B., Kalberer, M., Claeys, M., Allan, J., D’Anna, B., Decesari, S., Finessi, E., Glasius, M., Grgić, I., Hamilton, J. F., et al. (2015) · Chemical Reviews · doi:10.1021/cr5003485 · Cited by 656
Demarque, D. P., Crotti, A. E. M., Vessecchi, R., Lopes, J. L. C., & Lopes, N. P. (2016) · Natural Product Reports · doi:10.1039/c5np00073d · Cited by 513
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Salem, M. A., Perez de Souza, L., Serag, A., Fernie, A. R., Farag, M. A., Ezzat, S. M., & Alseekh, S. (2020) · Metabolites · doi:10.3390/metabo10010037 · Cited by 361
Perez de Souza, L., Alseekh, S., Scossa, F., & Fernie, A. R. (2021) · Nature Methods · doi:10.1038/s41592-021-01116-4 · Cited by 358
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part I
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.017 · Cited by 300
Terminology of bioanalytical methods (IUPAC Recommendations 2018)
Labuda, J., Bowater, R. P., Fojta, M., Gauglitz, G., Glatz, Z., Hapala, I., Havliš, J., Kilar, F., Kilar, A., Malinovská, L., et al. (2018) · Pure and Applied Chemistry · doi:10.1515/pac-2016-1120 · Cited by 287
Gilman, J. B., Lerner, B. M., Kuster, W. C., Goldan, P. D., Warneke, C., Veres, P. R., Roberts, J. M., de Gouw, J. A., Burling, I. R., & Yokelson, R. J. (2015) · Atmospheric Chemistry and Physics · doi:10.5194/acp-15-13915-2015 · Cited by 282
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
NORMAN guidance on suspect and non-target screening in environmental monitoring
Hollender, J., Schymanski, E. L., Ahrens, L., Alygizakis, N., Béen, F., Bijlsma, L., Brunner, A. M., Celma, A., Fildier, A., Fu, Q., et al. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00779-4 · Cited by 278
Malachová, A., Stránská, M., Václavíková, M., Elliott, C. T., Black, C., Meneely, J., Hajšlová, J., Ezekiel, C. N., Schuhmacher, R., & Krska, R. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0750-7 · Cited by 163
A Comparison of Common Mass Spectrometry Approaches for Paleoproteomics
Cleland, T. P., & Schroeter, E. R. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00703 · Cited by 62
Hawley, J. M., Owen, L. J., MacKenzie, F., Mussell, C., Cowen, S., & Keevil, B. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.243576 · Cited by 36
Zhou, W. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460400 · Cited by 28
DeltaMS: a tool to track isotopologues in GC- and LC-MS data
Baumeister, T. U. H., Ueberschaar, N., Schmidt-Heck, W., Mohr, J. F., Deicke, M., Wichard, T., Guthke, R., & Pohnert, G. (2018) · Metabolomics · doi:10.1007/s11306-018-1336-x · Cited by 25
Metadata
- Authors
- Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y.
- Venue
- Pure and Applied Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2013-06-06
- Volume
- 85
- Issue
- 7
- Pages
- 1515-1609
- ISSN
- 0033-4545 (ISSN-L)
- 1365-3075
- OpenAlex
- W2105084411
- Cited by
- 687
- References
- 156
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.