Diffuse reflectance from a finite blood medium: applications to the modeling of fiber optic catheters
The DOI matches its Crossref record.
Abstract
The scattering and absorption of light by randomly oriented, discretely scattering, red blood cells imbedded in a homogeneous plasma medium can be described by the P1 approximation to the one-speed transport equation, where the cells have the dual role of anisotropic sources for first scattering events and of scattering and absorption sites for subsequent scattering events. Equations for diffuse reflectance defined for a finite size receiver in the plane of a normally incident cylindrical photon beam are derived and compared with experimental data to fundamentally justify the basic sending-receiving characteristics of a fiber optic catheter model. A model of the fiber optic catheter used for the spectrophotometric measurement of oxygen content in blood is developed from the theory and compared with experimental results to further substantiate the theoretical approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
A practical model for subsurface light transport
Jensen, H. W., Marschner, S. R., Levoy, M., & Hanrahan, P. (2001) · Proceedings of the 28th annual conference on Computer graphics and interactive techniques · doi:10.1145/383259.383319 · Cited by 823
Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 819
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Optical reflectance and transmittance of tissues: principles and applications
Wilson, B. C., & Jacques, S. L. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64355 · Cited by 421
Model for photon migration in turbid biological media
Bonner, R. F., Nossal, R., Havlin, S., & Weiss, G. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000423 · Cited by 376
The physics of photodynamic therapy
Wilson, B. C., & Patterson, M. S. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/4/001 · Cited by 338
Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Friebel, M., Roggan, A., Müller, G., & Meinke, M. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2203659 · Cited by 283
Oxygen Saturation-Dependent Absorption and Scattering of Blood
Faber, D. J., Aalders, M. C. G., Mik, E. G., Hooper, B. A., van Gemert, M. J. C., & van Leeuwen, T. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.028102 · Cited by 264
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Takatani, S., & Graham, M. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326455 · Cited by 249
Condensed Monte Carlo simulations for the description of light transport
Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G. (1993) · Applied Optics · doi:10.1364/ao.32.000426 · Cited by 184
Cavinato, A. G., Mayes, D. M., Ge, Z., & Callis, J. B. (1990) · Analytical Chemistry · doi:10.1021/ac00217a015 · Cited by 158
Metadata
- Authors
- Reynolds, L., Johnson, C., & Ishimaru, A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1976-09-01
- Volume
- 15
- Issue
- 9
- Pages
- 2059
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1971052069
- Cited by
- 190
- References
- 0
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.