The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Magnetoencephalography with a chip-scale atomic magnetometer
Open accessAbstract
We report on the measurement of somatosensory-evoked and spontaneous magnetoencephalography (MEG) signals with a chip-scale atomic magnetometer (CSAM) based on optical spectroscopy of alkali atoms. The uncooled, fiber-coupled CSAM has a sensitive volume of 0.77 mm(3) inside a sensor head of volume 1 cm(3) and enabled convenient handling, similar to an electroencephalography (EEG) electrode. When positioned over O1 of a healthy human subject, α-oscillations were observed in the component of the magnetic field perpendicular to the scalp surface. Furthermore, by stimulation at the right wrist of the subject, somatosensory-evoked fields were measured with the sensors placed over C3. Higher noise levels of the CSAM were partly compensated by higher signal amplitudes due to the shorter distance between CSAM and scalp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Engelbrecht, R. S., Hsu, H., Amplifiers, P., et al. (1959) · Cited by 1,413
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
The SQUID Handbook: Applications of SQUIDs and SQUID Systems
(2006) · doi:10.1002/9783527609956 · Cited by 512
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Subpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
Self-citationMEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Presentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Magnetoencephalography in the study of human somatosensory cortical processing
Hari, R., & Forss, N. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0470 · Cited by 338
Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer
Johnson, C., Schwindt, P. D. D., & Weisend, M. (2010) · Applied Physics Letters · doi:10.1063/1.3522648 · Cited by 210
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
Femtotesla atomic magnetometry in a microfabricated vapor cell
Griffith, W. C., Knappe, S., & Kitching, J. (2010) · Optics Express · doi:10.1364/oe.18.027167 · Cited by 183
Self-citationDetection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances
Dupont-Roc, J., Haroche, S., & Cohen-Tannoudji, C. (1969) · Physics Letters A · doi:10.1016/0375-9601(69)90480-0 · Cited by 182
Magnetic resonance imaging with an optical atomic magnetometer
Xu, S., Yashchuk, V. V., Donaldson, M. H., Rochester, S. M., Budker, D., & Pines, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605396103 · Cited by 168
Korvenoja, A., Kirveskari, E., Aronen, H. J., Avikainen, S., Brander, A., Huttunen, J., Ilmoniemi, R. J., Jääskeläinen, J. E., Kovala, T. T., Mäkelä, J. P., et al. (2006) · Radiology · doi:10.1148/radiol.2411050796 · Cited by 149
Early deflections of cerebral magnetic responses to median nerve stimulation
Tiihonen, J., Hari, R., & Hämäläinen, M. (1989) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(89)90059-2 · Cited by 148
Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array
Wyllie, R., Kauer, M., Smetana, G., Wakai, R. T., & Walker, T. G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2619 · Cited by 140
Knappe, S. A., Sander, T. H., Kosch, O., Wiekhorst, F., Kitching, J. E., & Trahms, L. (2010) · Applied Physics Letters · doi:10.1063/1.3491548 · Cited by 130
Self-citationSampling theory for neuromagnetic detector arrays
Ahonen, A., Hämäläinen, M., Ilmoniemi, R. J., Kajola, M., Knuutila, J., Simola, J., & Vilkman, V. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.245606 · Cited by 124
MRI with an atomic magnetometer suitable for practical imaging applications
Savukov, I., Zotev, V. S., Volegov, P. L., Espy, M. A., Matlashov, A. N., Gómez, J. J., & Kraus, R. H. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.04.012 · Cited by 110
Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor
Bison, G., Wynands, R., & Weis, A. (2003) · Optics Express · doi:10.1364/oe.11.000904 · Cited by 100
Clinical applications of magnetoencephalography
Stufflebeam, S. M., Tanaka, N., & Ahlfors, S. P. (2009) · Human Brain Mapping · doi:10.1002/hbm.20792 · Cited by 92
Taue, S., Sugihara, Y., Kobayashi, T., Ichihara, S., Ishikawa, K., & Mizutani, N. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2048576 · Cited by 47
dc Magnetoencephalography: Direct measurement in a magnetically extremely-well shielded room
Burghoff, M., Sander, T. H., Schnabel, A., Drung, D., Trahms, L., Curio, G., & Mackert, B.-M. (2004) · Applied Physics Letters · doi:10.1063/1.1836869 · Cited by 35
Self-citationA microfabricated photonic magnetometer
Preusser, J., Gerginov, V. P., Knappe, S. A., & Kitching, J. E. (2008) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2008.4716451 · Cited by 16
Self-citationSingle evoked somatosensory MEG responses extracted by time delayed decorrelation
Sander, T. H., Burghoff, M., Curio, G., & Trahms, L. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853156 · Cited by 14
Self-citation[Recording of human magnetic fields].
Mn, L., Kozlov, A. N., Korinevskiĭ, A. V., Vp, M., & Sinel'nikova, S. E. (1978) · PubMed · Cited by 12
Cited by
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Self-citationBoto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Self-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Metadata
- Authors
- Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2012-04-17
- Volume
- 3
- Issue
- 5
- Pages
- 981
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2038735815
- Cited by
- 293
- References
- 30
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.