The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Multi-wavelength photoplethysmography method for skin arterial pulse extraction
Open accessAbstract
In this work, we present a multi-wavelength (MW) PPG method exploiting the wavelength dependence of light penetration in skin tissue to provide depth resolution of skin blood pulsation. The MW PPG system requires two to three light sources in different wavelengths and extracts the arterial blood pulsation through a multi-wavelength multi-layer light-skin interaction model, which removes the capillary pulsation (determined from the short-wavelength PPG signal) from the long-wavelength PPG signal using absorption weighting factors that are quasi-analytically calibrated. The extracted pulsations are used to calculate blood pressure (BP) through pulse transit time (PTT), and the results are compared with those obtained from the single wavelength PPG method. The comparative study is clinically performed on 20 subjects including 10 patients diagnosed with cardiovascular diseases and 10 healthy subjects. The result demonstrates that the MW PPG method significantly improves the measurement accuracy of systolic BP (SBP), reducing the mean absolute difference between the reference and the estimated SBP values from 5.7 mmHg (for single-wavelength PPG) to 2.9 mmHg (for three-wavelength PPG).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, in a study by Liu et al., where instead of using a single wavelength PPG, three wavelengths were used, the accuracy was increased about two times [114].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [114]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., van der Zee, P., Arridge, S., Wray, S., & Wyatt, J. S. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,251
The modified Beer–Lambert law revisited
Kocsis, L., Hermán, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 682
Okada, E., Firbank, M., Schweiger, M. J., Arridge, S., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 285
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 265
陳, 文. (2001) · Medical Entomology and Zoology · Cited by 115
Non-invasive physiological measurements
Escourrou, P. (1988) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1988.95111 · Cited by 102
Flagged first, then by citations
Research works printed but not linked: 1
- Tamura, 2014, Electronics (Basel), 3, 282
Cited by
Sorted by citations
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
Self-citationKim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 260
A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China
Liang, Y., Chen, Z., Liu, G., & Elgendi, M. (2018) · Scientific Data · doi:10.1038/sdata.2018.20 · Cited by 215
Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 233
Self-citationA Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155
Liu, J., Yan, B. P., Zhang, Y., Ding, X., Su, P., & Zhao, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874957 · Cited by 139
Self-citationEmerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring
Zhao, L., Liang, C., Huang, Y., Zhou, G., Xiao, Y., Ji, N., Zhang, Y., & Zhao, N. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00835-6 · Cited by 137
Self-citationFranklin, D., Tzavelis, A., Lee, J. Y., Chung, H. U., Trueb, J. T., Arafa, H., Kwak, S. S., Huang, I. A., Liu, Y., Rathod, M., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01098-y · Cited by 119
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103
Pankaj, Kumar, A., Komaragiri, R., & Kumar, M. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09597-4 · Cited by 84
Cuffless Blood Pressure Measurement Using Smartwatches: A Large-Scale Validation Study
Liu, Z.-D., Li, Y., Zhang, Y., Zeng, J., Chen, Z.-X., Cui, Z., Liu, J., & Miao, F. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3278168 · Cited by 83
Self-citationWireless and battery-free platforms for collection of biosignals
Stuart, T., Cai, L., Burton, A., & Gutruf, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113007 · Cited by 78
Diaphragm‐based optical fiber sensor for pulse wave monitoring and cardiovascular diseases diagnosis
Wang, J., Liu, K., Sun, Q., Ni, X., Ai, F., Wang, S., Yan, Z., & Liu, D. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201900084 · Cited by 75
Ueafuea, K., Boonnag, C., Sudhawiyangkul, T., Leelaarporn, P., Gulistan, A., Chen, W., Mukhopadhyay, S. C., Wilaiprasitporn, T., & Piyayotai, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3046259 · Cited by 72
Investigating the origin of photoplethysmography using a multiwavelength Monte Carlo model
Chatterjee, S., Budidha, K., & Kyriacou, P. A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/aba008 · Cited by 67
Ha, J., Eun, H. J., Park, B., Ahn, H., Hwang, D. R., Shim, Y., Heo, J., Lee, C., Yoon, S. C., Kim, J. H., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202211486 · Cited by 65
Liu, J., Qiu, S., Luo, N., Lau, S.-K., Yu, H., Kwok, T. C. Y., Zhang, Y., & Zhao, N. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3004032 · Cited by 62
Self-citationZhao, J. C., Zhang, S., Sun, Y., Zhou, N., Yu, H., Zhang, H., & Jia, D. (2022) · ACS Photonics · doi:10.1021/acsphotonics.2c00898 · Cited by 63
Yousefian, P., Shin, S., Mousavi, A. S., Kim, C., Mukkamala, R., Jang, D.-G., Ko, B.-H., Lee, J., Kwon, U.-K., Kim, Y. H., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-46936-9 · Cited by 54
Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension
Welykholowa, K., Hosanee, M., Chan, G., Cooper, R. E., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C., Lovell, N. H., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9041203 · Cited by 51
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Advanced thermal sensing techniques for characterizing the physical properties of skin
Madhvapathy, S. R., Arafa, H., Patel, M. J., Winograd, J., Kong, J., Zhu, J., Xu, S., & Rogers, J. A. (2022) · Applied Physics Reviews · doi:10.1063/5.0095157 · Cited by 48
Non-invasive hemoglobin measurement using embedded platform
Pinto, C. F., Parab, J. S., & Naik, G. M. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100370 · Cited by 42
Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography
Han, S., Roh, D., Park, J., & Shin, H. (2019) · Sensors · doi:10.3390/s19245441 · Cited by 41
PPG/ECG Multisite Combo System Based on SiPM Technology
Vinciguerra, V., Ambra, E., Maddiona, L., Romeo, M. F., Mazzillo, M. C., Rundo, F., Fallica, G., Pompeo, F., Chiarelli, A. M., Zappasodi, F., et al. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-3-030-04324-7_44 · Cited by 38
Premkumar, S., & Hemanth, D. J. (2022) · Informatics · doi:10.3390/informatics9030057 · Cited by 37
Andreozzi, E., Sabbadini, R., Centracchio, J., Bifulco, P., Irace, A., Breglio, G., & Riccio, M. (2022) · Sensors · doi:10.3390/s22197566 · Cited by 38
Garrett, A., Kim, B., Sie, E. J., Gurel, N. Z., Marsili, F., Boas, D. A., & Roblyer, D. M. (2023) · Biomedical Optics Express · doi:10.1364/boe.482740 · Cited by 32
MW-PPG Sensor: An on-Chip Spectrometer Approach
Chang, C.-C., Wu, C.-T., Choi, B. I., & Fang, T.-J. (2019) · Sensors · doi:10.3390/s19173698 · Cited by 30
Advances in PPG Sensors Data Acquisition With Light-to-Digital Converters: A Review
Chettri, N., Aprile, A., Bonizzoni, E., & Malcovati, P. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3420170 · Cited by 29
Balmer, J., Pretty, C. G., Davidson, S. M., Desaive, T., Kamoi, S., Pironet, A., Morimont, P., Janssen, N., Lambermont, B. C., Shaw, G. M., et al. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aada72 · Cited by 28
IoT-based smart triage of Covid-19 suspicious cases in the Emergency Department
Fyntanidou, B., Zouka, M., Apostolopoulou, A., Bamidis, P. D., Billis, A. S., Mitsopoulos, K., Angelidis, P. A., & Fourlis, A. (2020) · IEEE Globecom Workshops (GC Wkshps) · doi:10.1109/gcwkshps50303.2020.9367584 · Cited by 25
Ndabakuranye, J. P., Li, S., Burchall, G., Fox, K. E., Piva, T. J., Xu, Z., Kavehei, O., Prawer, S., & Ahnood, A. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00033d · Cited by 24
Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths
Martín-Escudero, P., Cabanas, A. M., Fuentes, M. E., & Galindo-Canales, M. (2021) · Biosensors · doi:10.3390/bios11100391 · Cited by 25
Carek, A. M., & Holz, C. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3264906 · Cited by 22
Photoplethysmography signal quality assessment using attractor reconstruction analysis
Schmith, J., Kelsch, C., Cunha, B., Prade, L. R., Martins, E. A., Keller, A. L., & de Figueiredo, R. M. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105142 · Cited by 20
Mohapatra, P., Premkumar, P. S., & Sivaprakasam, M. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2786677 · Cited by 20
Double-Sided Pressure-Sensitive Adhesive Materials under Human-Centric Extreme Environments
Jeon, J., Kim, J., Park, S., Bryan, G. M., Broderick, T. J., Stone, M. O., & Tsukruk, V. V. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c09327 · Cited by 18
Sondej, T., Jannasz, I., Sieczkowski, K., Dobrowolski, A. P., Obiała, K., Targowski, T., & Olszewski, R. (2021) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2021.11.001 · Cited by 19
Photoacoustic remote sensing elastography
Yuan, Y., Wen, X., Yuan, B., Xin, H., Fang, B., Yang, S., & Xiong, K. (2023) · Optics Letters · doi:10.1364/ol.485623 · Cited by 17
Lapitan, D. G., & Tarasov, A. P. (2019) · CAOL . International Conference on Advanced Optoelectronics and Lasers · doi:10.1109/caol46282.2019.9019552 · Cited by 18
Ballaji, H. K., Correia, R. G., Korposh, S., Hayes‐Gill, B., Hernandez, F. U., Salisbury, B., & Morgan, S. P. (2020) · Sensors · doi:10.3390/s20226568 · Cited by 19
Liu, J., Yan, B. P., Chen, S., Zhang, Y., Sodini, C. G., & Zhao, N. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3055760 · Cited by 17
Self-citationMeasurement of stress-induced sympathetic nervous activity using multi-wavelength PPG
Udhayakumar, R. K., Rahman, S., Buxi, D., Macefield, V. G., Dawood, T., Mellor, N. E., & Karmakar, C. K. (2023) · Royal Society Open Science · doi:10.1098/rsos.221382 · Cited by 16
Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation
Cheung, M. Y., Sabharwal, A., Coté, G. L., & Veeraraghavan, A. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3434344 · Cited by 23
Chen, S., Chuang, Y.-C., & Chang, C. (2020) · Sensors · doi:10.3390/s20226556 · Cited by 19
Clinical grade SpO2 prediction through semi-supervised learning
Priem, G., Martinez, C., Bodinier, Q., & Carrault, G. (2020) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe50027.2020.00155 · Cited by 13
A State‐Of‐The‐Art Survey of Remote Photoplethysmography for Contactless Health Parameters Sensing
Sakib, S., Hasan, Z., & Roy, N. (2025) · Wiley Interdisciplinary Reviews Data Mining and Knowledge Discovery · doi:10.1002/widm.70039 · Cited by 11
Measurement and Analysis of Local Pulse Transit Time for Emotion Recognition
Beckmann, N., Viga, R., Doğangün, A., & Grabmaier, A. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2915529 · Cited by 10
Acevedo, R. U., Sánchez, L. O., Londoño, S. V., Mejía‐Mejía, E., Villa, R. T., & Montoya, Y. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.1.017001 · Cited by 9
A switchable multi-wavelength mode-locked fiber laser based on a multi-mode interference device
Geng, X., Jiang, Y., Gu, H., Luo, S., Sun, M., & Li, L. (2023) · Infrared Physics & Technology · doi:10.1016/j.infrared.2023.104812 · Cited by 9
Non-invasive glucose measurement using 950 nm reflective short wave NIR technique
Naresh, M. S., & Peddakrishna, S. (2023) · Research on Biomedical Engineering · doi:10.1007/s42600-023-00308-5 · Cited by 9
Lu, Y., Yu, Z., Liu, J., An, Q., Chen, C., Li, Y., & Wang, Y. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac7841 · Cited by 11
Self-citationPasta, S., Blanos, P., Yan, L., Hu, S., Scardulla, F., D’Acquisto, L., & Barrett, L. A. (2018) · Design and Quality for Biomedical Technologies · doi:10.1117/12.2287845 · Cited by 9
Awan, M. A., Ahmed, M., & Wang, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3180927 · Cited by 8
Sirkiä, J., Panula, T., & Kaisti, M. (2024) · Advanced Science · doi:10.1002/advs.202310022 · Cited by 7
Rundo, F., Sabrina Conoci, A., Spampinato, C., Leotta, R., Trenta, F., & Battiato, S. (2021) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2021.667008 · Cited by 10
Exploring the Usage of Time-of-Flight Cameras for Contact and Remote Photoplethysmography
Nahler, C., Feldhofer, B., Rüther, M., Holweg, G., & Druml, N. (2018) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2018.00079 · Cited by 8
Sensitivity of Video-Based Pulse Arrival Time to Dynamic Blood Pressure Changes
Shirbani, F., Blackmore, C., Kazzi, C., Tan, I., Butlin, M., & Avolio, A. P. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513058 · Cited by 8
Comparisons of Oscillometric Blood Pressure Measurements at Different Sites of the Upper Limb
Liu, J., Ou, Y., Yan, B. P., Sodini, C. G., & Zhao, N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512349 · Cited by 8
Self-citationHe, Q., Sun, Z., Li, Y., Wang, W., & Wang, R. K. (2021) · Biomedical Optics Express · doi:10.1364/boe.423160 · Cited by 9
Cuffless Blood Pressure Estimation Model Based on Prior Information of Physiological Data and LSTM
Guo, P. F., Lu, Y., Li, J., Lv, Y., Feng, J., & Liu, Y. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3438773 · Cited by 8
Gao, Y.-H., Li, J., Fan, C.-H., Leung, K. N., Zhang, Y., & Pun, K. (2025) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2025.3564384 · Cited by 7
Self-citationTAMURA, T., & Maeda, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_6 · Cited by 11
Abdulhadi, A. H., & Al‐Janabi, A. (2022) · Optik · doi:10.1016/j.ijleo.2022.169404 · Cited by 7
Botrugno, C., Leogrande, E., Dell’Olio, F., & Natale, T. (2023) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi58316.2023.10164373 · Cited by 7
Liu, L., Wang, Z., Zhang, X., Zhuang, Y., & Liang, Y. (2025) · Algorithms · doi:10.3390/a18020075 · Cited by 6
Efficacy of Wearable Single-Lead ECG Monitoring during Exercise Stress Testing: A Comparative Study
Choi, H., Lee, S. J., Choi, J. D., Kim, G., Lee, Y.-S., & Lee, J. (2024) · Sensors · doi:10.3390/s24196394 · Cited by 6
Janjua, G. M. W., Finlay, D., Guldenring, D., Haq, A. U., & McLaughlin, J. A. (2019) · IEEE Access · doi:10.1109/access.2019.2944212 · Cited by 6
Performance evaluation of blood pressure estimation using an RGB-NIR camera
Kawasaki, S., Kinefuchi, M., Hino, Y., Kobayashi, A., Kawahito, S., Takahashi, M., & Tsumura, N. (2025) · Artificial Life and Robotics · doi:10.1007/s10015-025-01015-3 · Cited by 5
Baciu, V.-E., Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2023) · Sensors · doi:10.3390/s23156947 · Cited by 5
Intraoperative Optical Monitoring of Spinal Cord Hemodynamics Using Multiwavelength Imaging System
Mainard, N., Tsiakaka, O., Li, S., Denoulet, J., Messaoudene, K., Vialle, R., & Feruglio, S. (2022) · Sensors · doi:10.3390/s22103840 · Cited by 5
Guang, Z., Wang, Z., Hou, F., Wan, Z., Feng, C., Yu, M. Y., Wang, J., & Wang, H. (2021) · Review of Scientific Instruments · doi:10.1063/5.0037661 · Cited by 5
Na, Y., Kim, C., Kim, K., Kim, T. H., Kwon, S. H., Kang, I., Jung, Y. W., Kim, T. W., Cho, D.-H., An, J., et al. (2024) · Biosensors · doi:10.3390/bios14020109 · Cited by 4
Photoplethysmogram analysis and applications: An Integrative Review (Preprint)
Shin, H., Park, J., Seok, H. S., & Kim, S. (2020) · JMIR Biomedical Engineering · doi:10.2196/25567 · Cited by 4
Core body temperature estimation model with thermal contact resistance compensation
Ren, X., Zhang, Y., Yang, H., Li, K., Ye, X., & Zhou, C. (2024) · Measurement · doi:10.1016/j.measurement.2024.115687 · Cited by 3
Self-citationEvaluating Diversity in Open Photoplethysmography Datasets: Protocol for a Systematic Review
Penmetcha, V., Rambabu, L., Smith, B. G., Mantle, O., Edmiston, T., Hobbs, L., Nagraj, S., Charlton, P. H., & Bashford, T. (2025) · JMIR Research Protocols · doi:10.2196/73040 · Cited by 3
Zhao, J. C., Zhang, Z., Han, Z., Wang, Q., Yu, H., Zhang, H., & Jia, D. (2022) · Applied Optics · doi:10.1364/ao.454104 · Cited by 3
Moghaddam, M., Collins, J. P., Gardner, C. E., & Rabel, M. C. (2025) · Sensors · doi:10.3390/s26010176 · Cited by 3
Mohammad, U., Zhang, Y., Zada, M., Zhang, M., Tang, F., Guo, Y., & Bermak, A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3649834 · Cited by 2
Self-citationGao, Y.-H., Fan, C.-H., Li, J., Li, S., Jin, Z., Leung, K. N., Zhang, Y., Tang, X., & Pun, K. (2026) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2026.3675769 · Cited by 2
Self-citationChen, H., Zeng, Z., Zhang, Y., Lyu, L., Chan, R. H. M., Zhang, Y., & Wei, R. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3587042 · Cited by 2
Self-citationTowards pulsatile multilayer tissue phantoms
Jenne, S., Zappe, H. P., & Herdt, S. (2022) · doi:10.1117/12.2608118 · Cited by 2
Using Consumer-Graded Wearable Devices for Sleep Apnea Pre-Diagnosis: A Survey and Recommendations
Wongtaweesup, C., Thapa, K., Anutariya, C., Sujarae, A., & Tisyakorn, J. (2023) · International Joint Conference on Computer Science and Software Engineering · doi:10.1109/jcsse58229.2023.10202122 · Cited by 1
Hino, Y., Ashida, K., Ogawa‐Ochiai, K., & Tsumura, N. (2023) · Journal of Imaging · doi:10.3390/jimaging9100202 · Cited by 1
Automated estimation of blood pressure using PPG recordings: an updated review
Liu, H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-44-314141-6.00014-1 · Cited by 1
Laamanen, P., Laivuori, M., Noronen, K., & Venermo, M. A. (2024) · Vascular · doi:10.1177/17085381241305192 · Cited by 1
TiO 2 /PSi Heterostructure-Based Multiwavelength Photodetector System for AIoT Applications
Chalka, V. K., Singh, M., Vadera, N., Srivastava, P., Giridhar, U., Banerjee, R., Dhanekar, S., & Rangra, K. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3571918 · Cited by 1
Dual-wavelength NIR lasers based on cladding-pumped bismuth-doped heterogeneous fibers
Kharakhordin, A. V., Umnikov, A. A., Alyshev, S. V., Khegai, A. M., Oleinik, D. I., Elopov, A. V., Lipatov, D. S., Riumkin, K. E., Abramov, A. N., Firstova, E., et al. (2025) · Optical Fiber Technology · doi:10.1016/j.yofte.2025.104277 · Cited by 1
Николов, Н. А., Soloviov, O. I., & Burkovskyi, Y. (2022) · Ukrainian Journal of Occupational Health · doi:10.33573/ujoh2022.02.155 · Cited by 1
Review: Manufacturing of fiber optic based glucose sensor and infrared biosensor
Sari, R. P., Alizar, Isa, I. M., & Yulkifli, Y. (2023) · AIP conference proceedings · doi:10.1063/5.0126035 · Cited by 1
Chen, Y. (2022) · medRxiv · doi:10.1101/2022.03.14.22272354 · Cited by 1
Error Prevention in Sensors and Sensor Systems
Chacon, P. J. (2021) · doi:10.31390/gradschool_dissertations.5543
Systolic Blood Pressure Estimation Via Photoplethysmography Features-An Animal Study
Wang, W., Delianides, C. A., Green, D. B., Mohseni, P., Kilgore, K. L., & Najafizadeh, L. (2022) · Optics in the Life Sciences · doi:10.1364/translational.2022.jm3a.6
Comparative Oscillometry on Finger Using Pneumatics and Multi-wavelength Photoplethysmography
Talts, J., Ümarik, S., Kivastik, J., & Jagomägi, K. (2023) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-37132-5_24
Wearable health monitoring system using multispectral sensing with visible and near-infrared light
Li, D., & Li, T. (2025) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.3044071
Continuous and Cuffless Blood Pressure Estimation Using Photoplethysmography for Wearable Devices
Tiwari, S., Saini, S. K., Joshi, A. M., & Maddila, R. K. (2024) · IEEE India Conference · doi:10.1109/indicon63790.2024.10958245
A non-invasive continuous glucose monitoring method based on the Bergman minimal model
Li, A., Zhao, L., Wu, C., Geng, Z., Yang, L., & Tang, F. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-025-03422-x
Metadata
- Authors
- Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N.
- Affiliations
- Chinese University of Hong Kong (HK)
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2016-09-27
- Volume
- 7
- Issue
- 10
- Pages
- 4313
- ISSN
- 2156-7085 (ISSN-L)
- PMC
- PMC5102532
- OpenAlex
- W2526662839
- Cited by
- 107
- References
- 18
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 12 · 2023: 17 · 2022: 17 · 2021: 10 · 2020: 12 · 2019: 10 · 2018: 9 · 2017: 1
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Biomedical Optics Express (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Chow Yuk Ho Technology Centre for Innovative Medicine (TIM Seed Grant)
- Innovation and Technology Commmission of Hong Kong (ITS/275/15FP)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- light penetration depth, pulse transit time, systolic blood pressure estimation, cardiovascular disease
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review