Cited by 30Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesAdvanced Sensor and Energy Harvesting Materials

MW-PPG Sensor: An on-Chip Spectrometer Approach

Open access
Chang, Cheng-Chun, Wu, Chien-Ta, Choi, Byung Il, Fang, Tong-Jing·2019·Sensors

Abstract

Multi-wavelength photoplethysmography (MW-PPG) sensing technology has been known to be superior to signal-wavelength photoplethysmography (SW-PPG) sensing technology. However, limited by the availability of sensing detectors, many prior studies can only use conventional bulky and pricy spectrometers as the detectors, and hence cannot bring the MW-PPG technology to daily-life applications. In this study we developed a chip-scale MW-PPG sensor using innovative on-chip spectrometers, aimed at wearable applications. Also in this paper we present signal processing methods for robustly extracting the PPG signals, in which an increase of up to 50% in the signal-to-noise ratio (S/N) was observed. Example measurements of saturation of peripheral blood oxygen (SpO2) and blood pressure were conducted.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s19173698

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Blood oxygenation is proportional to reflected red light (622-780 nm) and IR (780-2400 nm).

    “Blood oxygenation is proportional to reflected red light (622–780 nm) and IR (780–2400 nm) [87].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [87]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Chang, C.-C., Wu, C.-T., Choi, B. I., & Fang, T.-J.
Affiliations
  • National Taipei University of Technology (TW)
  • nanoLambda Co. Ltd., Daejeon 34141, Korea
  • National Defense Medical Center (TW)
Corresponding author
Chang, Cheng-Chun
Venue
Sensors
Publisher
MDPI AG
Published
2019-08-26
Volume
19
Issue
17
Pages
3698
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2969406974
Cited by
30
References
29
Citations by year
2026: 2 · 2025: 5 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 6 · 2020: 5
FWCI
1.41
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Ministry of Science and Technology, Taiwan (MOST107-2221-E027-084-MY2)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
on-chip spectrometer, chip-scale sensors, wearable sensors, signal-to-noise ratio, blood pressure measurement, non-invasive vital sign monitoring
MeSH terms
Humans, Spectrum Analysis, Biosensing Techniques, Photoplethysmography, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review