The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Optical image reconstruction using frequency-domain data: simulations and experiments
Abstract
Optical image reconstruction in a heterogeneous turbid medium with the use of frequency-domain measurements is investigated in detail. A finite-element reconstruction algorithm for optical data based on a diffusion equation approximation is presented and confirmed by a series of simulations and experiments using phantoms having optical properties in the range of those expected for tissues. Simultaneous reconstruction of absorption and scattering coefficients is achieved both theoretically and experimentally. Images with different target locations and contrast levels between target and background are also successfully recovered. All reconstructed images from both simulated and experimental data are derived directly from absolute optical data in which no differential measurement scheme is used. Results from the use of simulated and measured data suggest that quantitative images can be produced in terms of absorption and scattering coefficient values and location, size, and shape of heterogeneities within a circular background region over a range of contrast levels. Further, the effects of modulation frequency are found to be relatively modest, although boundary conditions appear to be important factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Self-citationBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
The multiplier method of Hestenes and Powell applied to convex programming
Rockafellar, R. T. (1973) · Journal of Optimization Theory and Applications · doi:10.1007/bf00934777 · Cited by 705
Experimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomography
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1995) · Optics Letters · doi:10.1364/ol.20.000426 · Cited by 440
Optical properties of normal and diseased human breast tissues in the visible and near infrared
Peters, V. G., Wyman, D. R., Patterson, M. S., & Frank, G. L. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/010 · Cited by 414
Self-citationFishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Fantini, S., Franceschini, M. A., Fishkin, J. B., Barbieri, B., & Gratton, E. (1994) · Applied Optics · doi:10.1364/ao.33.005204 · Cited by 259
Frequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory
Pogue, B. W., & Patterson, M. S. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/7/008 · Cited by 184
Self-citationUltrafast time-gated imaging in thick tissues: a step toward optical mammography
Das, B. B., Yoo, K. M., & Alfano, R. R. (1993) · Optics Letters · doi:10.1364/ol.18.001092 · Cited by 173
The use of India ink as an optical absorber in tissue-simulating phantoms
Madsen, S. J., Patterson, M. S., & Wilson, B. C. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/4/012 · Cited by 170
Self-citation(1993) · SPIE Proceedings · doi:10.1117/12.2283746 · Cited by 163
Time-dependent optical spectroscopy and imaging for biomedical applications
Wilson, B. C., Sevick, E., Patterson, M. S., & Chance, B. (1992) · Proceedings of the IEEE · doi:10.1109/5.149454 · Cited by 131
Self-citationA novel approach to laser tomography
Gratton, E., Mantulin, W. W., vandeVen, M., Fishkin, J. B., Maris, M. B., & Chance, B. (1993) · Bioimaging · doi:10.1002/1361-6374(199303)1:1<40::aid-bio7>3.3.co;2-m · Cited by 59
Cited by
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Metadata
- Authors
- Jiang, H., Pogue, B. W., Patterson, M. S., Paulsen, K. D., & Osterberg, U. L.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1996-02-01
- Volume
- 13
- Issue
- 2
- Pages
- 253
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2040626002
- Cited by
- 260
- References
- 16
- FWCI
- 26.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.