The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Retinal limits to the detection and resolution of gratings
Abstract
The maximum spatial frequency for the detection and resolution of sinusoidal gratings was determined as a function of stimulus location across the visual field. Stimuli were produced directly on the retina as interference fringes, thus avoiding possible loss of image quality, which may occur when the optical system of the eye is used to form the retinal image. Contrary to earlier reports, we found that subjects could detect gratings with spatial frequencies much higher than the resolution limit. At 5 degrees of eccentricity from the fovea, the detection limit was about three times the resolution limit, and this factor increased to about 10 as the test stimulus was moved 35 degrees into the periphery. Quantitative comparison of the data with retinal anatomy and physiology suggests that pattern resolution is limited by the spacing of primate beta (midget) retinal ganglion cells, whereas pattern detection is limited by the size of individual cones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque.
Derrington, A. M., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015498 · Cited by 1,058
Optical quality of the human eye
Campbell, F. W., & Gubisch, R. W. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008056 · Cited by 810
Functional properties of ganglion cells of the rhesus monkey retina.
De Monasterio, F. M., & Gouras, P. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011086 · Cited by 616
Visual resolution, contrast sensitivity, and the cortical magnification factor
Virsu, V., & Rovamo, J. (1979) · Experimental Brain Research · doi:10.1007/bf00236818 · Cited by 536
Boycott, B. B., & Dowling, J. E. (1969) · Philosophical Transactions of the Royal Society of London. Series B, Biological Sciences · doi:10.1098/rstb.1969.0004 · Cited by 534
Quantitative analysis of retinal ganglion cell classifications.
Hochstein, S., & Shapley, R. M. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011594 · Cited by 477
Linear and nonlinear spatial subunits in Y cat retinal ganglion cells.
Hochstein, S., & Shapley, R. M. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011595 · Cited by 471
Parasol and midget ganglion cells of the human retina
Rodieck, R. W., Binmoeller, K. F., & Dineen, J. (1985) · Journal of Comparative Neurology · doi:10.1002/cne.902330107 · Cited by 404
Morphology and mosaic of on- and off-beta cells in the cat retina and some functional considerations
Wässle, H., Boycott, B. B., & Illing, R. B. (1981) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1981.0033 · Cited by 345
Size, scatter and coverage of ganglion cell receptive field centres in the cat retina.
Peichl, L., & Wässle, H. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012803 · Cited by 286
Visual Sensory Units and the Minimal Angle of Resolution
Weymouth, F. W. (1958) · American Journal of Ophthalmology · doi:10.1016/0002-9394(58)90042-4 · Cited by 279
Aliasing in human foveal vision
Williams, D. R. (1985) · Vision Research · doi:10.1016/0042-6989(85)90113-0 · Cited by 277
Rolls, E. T., & Cowey, A. (1970) · Experimental Brain Research · doi:10.1007/bf00235053 · Cited by 274
The neural representation of visual space
DRASDO, N. (1977) · Nature · doi:10.1038/266554a0 · Cited by 244
Photoreceptor diameter and spacing for highest resolving power
Snyder, A. W., & Miller, W. H. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.000696 · Cited by 188
Regional variations in the visual acuity for interference fringes on the retina
Green, D. G. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009065 · Cited by 186
Functional organization of the peripheral retina: Sensitivity to periodic stimuli
Hilz, R., & Cavonius, C. R. (1974) · Vision Research · doi:10.1016/0042-6989(74)90006-6 · Cited by 181
Convergence and interaction of neck and macular vestibular inputs on reticulospinal neurons
Pompeiano, O., Manzoni, D., Srivastava, U. C., & Stampacchia, G. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90142-8 · Cited by 174
Resolution of gratings oriented along and across meridians in peripheral vision.
Rovamo, J. M., Virsu, V., Laurinen, P. I., & Hyvärinen, L. (1982) · PubMed · Cited by 173
Visual Resolution and Receptive Field Size: Examination of Two Kinds of Cat Retinal Ganglion Cell
Cleland, B. G., Harding, T. H., & Tulunay-Keesey, Ü. (1979) · Science · doi:10.1126/science.472720 · Cited by 145
Effect of dioptrics on peripheral visual acuity
Millodot, M., Johnson, C. A., Lamont, A., & Leibowitz, H. W. (1975) · Vision Research · doi:10.1016/0042-6989(75)90190-x · Cited by 129
Modulation thresholds for sinusoidal light distributions on the retina
Westheimer, G. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006469 · Cited by 129
Optical Image Quality and the Cone Mosaic
Snyder, A. W., Bossomaier, T. R. J., & Hughes, A. (1986) · Science · doi:10.1126/science.3941914 · Cited by 96
Averaging over the foveal receptor aperture curtails aliasing
Miller, W. H., & Bernard, G. D. (1983) · Vision Research · doi:10.1016/0042-6989(83)90147-5 · Cited by 78
Seeing through the photoreceptor mosaic
Williams, D. R. (1986) · Trends in Neurosciences · doi:10.1016/0166-2236(86)90058-5 · Cited by 77
Visual resolution in the periphery
Kerr, J. L. (1971) · Perception & Psychophysics · doi:10.3758/bf03212671 · Cited by 74
Chapter 9 New perspectives in retinal organisation
Hughes, A. (1985) · Progress in Retinal Research · doi:10.1016/0278-4327(85)90011-2 · Cited by 53
Orientation bias of brisk-transient y-cells of the cat retina for drifting and alternating gratings
Thibos, L. N., & Levick, W. R. (1985) · Experimental Brain Research · doi:10.1007/bf00238948 · Cited by 52
Self-citationChapter 11 Receptive fields of cat ganglion cells: Classification and construction
Levick, W. R., & Thibos, L. N. (1983) · Progress in Retinal Research · doi:10.1016/0278-4327(83)90012-3 · Cited by 35
Self-citationInterferometric resolution determinations in the fovea and parafovea
Enoch, J. M., & Hope, G. M. (1973) · Documenta Ophthalmologica · doi:10.1007/bf00151803 · Cited by 31
Cited by
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
Towards foveated rendering for gaze-tracked virtual reality
Patney, A., Salvi, M., Kim, J., Kaplanyan, A., Wyman, C., Benty, N., Luebke, D., & Lefohn, A. (2016) · ACM Transactions on Graphics · doi:10.1145/2980179.2980246 · Cited by 491
The mosaic of midget ganglion cells in the human retina
Dacey, D. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-12-05334.1993 · Cited by 480
Dendritic field size and morphology of midget and parasol ganglion cells of the human retina.
Dacey, D. M., & Petersen, M. R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.20.9666 · Cited by 473
Cortical magnification within human primary visual cortex correlates with acuity thresholds
Duncan, R. O., & Boynton, G. M. (2003) · Neuron · doi:10.1016/s0896-6273(03)00265-4 · Cited by 385
Metadata
- Authors
- Thibos, L. N., Cheney, F. E., & Walsh, D. J.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1987-08-01
- Volume
- 4
- Issue
- 8
- Pages
- 1524
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2011672400
- Cited by
- 255
- References
- 30
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.