The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head
Open accessAbstract
We describe a novel Monte Carlo code for photon migration through 3D media with spatially varying optical properties. The code is validated against analytic solutions of the photon diffusion equation for semi-infinite homogeneous media. The code is also cross-validated for photon migration through a slab with an absorbing heterogeneity. A demonstration of the utility of the code is provided by showing time-resolved photon migration through a human head. This code, known as 'tMCimg', is available on the web and can serve as a resource for solving the forward problem for complex 3D structural data obtained by MRI or CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Experimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomography
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1995) · Optics Letters · doi:10.1364/ol.20.000426 · Cited by 440
Self-citationHielscher, A. H., Alcouffe, R. E., & Barbour, R. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/5/017 · Cited by 332
Photon-measurement density functions Part 2: Finite-element-method calculations
Arridge, S. R., & Schweiger, M. (1995) · Applied Optics · doi:10.1364/ao.34.008026 · Cited by 310
Three-dimensional optical tomography of hemodynamics in the human head
Bluestone, A. Y., Abdoulaev, G., Schmitz, C. H., Barbour, R. L., & Hielscher, A. H. (2001) · Optics Express · doi:10.1364/oe.9.000272 · Cited by 259
Monte Carlo Modeling of Light Transport in Tissues
Jacques, S. L., & Wang, L. (1995) · Optical-Thermal Response of Laser-Irradiated Tissue · doi:10.1007/978-1-4757-6092-7_4 · Cited by 252
Noninvasive Functional Imaging of Human Brain Using Light
Benaron, D. A., Hintz, S. R., Villringer, A., Boas, D., Kleinschmidt, A., Frahm, J., Hirth, C., Obrig, H., van Houten, J. C., Kermit, E. L., et al. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200003000-00005 · Cited by 239
Self-citationOn-line optical imaging of the human brain with 160-ms temporal resolution
Franceschini, M. A., Toronov, V., Filiaci, M. E., Gratton, E., & Fantini, S. (2000) · Optics Express · doi:10.1364/oe.6.000049 · Cited by 237
Diffusion approximation for a dissipative random medium and the applications
Furutsu, K., & Yamada, Y. (1994) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.50.3634 · Cited by 202
An investigation of light transport through scattering bodies with non-scattering regions
Firbank, M., Arridge, S. R., Schweiger, M., & Delpy, D. T. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/4/012 · Cited by 189
Firbank, M., Okada, E., & Delpy, D. T. (1998) · NeuroImage · doi:10.1006/nimg.1998.0348 · Cited by 172
Bedside functional imaging of the premature infant brain during passive motor activation
Hintz, S. R., Benaron, D. A., Siegel, A. M., et al. (2001) · Journal of Perinatal Medicine · doi:10.1515/jpm.2001.048 · Cited by 131
Does the photon-diffusion coefficient depend on absorption?
Durduran, T., Yodh, A. G., Chance, B., & Boas, D. A. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.003358 · Cited by 123
Self-citationBoundary conditions for light propagation in diffusive media with nonscattering regions
Ripoll, J., Nieto‐Vesperinas, M., Arridge, S., & Dehghani, H. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.001671 · Cited by 75
Robertson, C. S., Gopinath, S. P., & Chance, B. (1995) · Journal of Neurotrauma · doi:10.1089/neu.1995.12.591 · Cited by 74
Okada, E., Schweiger, M. J., Arridge, S., Firbank, M., & Delpy, D. T. (1996) · Applied Optics · doi:10.1364/ao.35.003362 · Cited by 52
Cited by
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationRecent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Self-citationJan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Self-citation
Metadata
- Authors
- Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2002-02-11
- Volume
- 10
- Issue
- 3
- Pages
- 159
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2169523701
- Cited by
- 599
- References
- 26
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.