The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Chromophore concentrations, absorption and scattering properties of human skin in-vivo
Open accessAbstract
Absorption and reduced scattering coefficients of in-vivo human skin provide critical information on non-invasive skin diagnoses for aesthetic and clinical purposes. To date, very few in-vivo skin optical properties have been reported. Previously, we reported absorption and scattering properties of in-vivo skin in the wavelength range from 650 to 1000 nm using the diffusing probe in the "modified two-layer geometry". In this study, we determine the spectra of skin optical properties continuously in the range from 500 to 1000 nm. It was found that the concentration of chromophores, such as oxy-hemoglobin, deoxy-hemoglobin, and melanin, calculated based on the absorption spectra of eighteen subjects at wavelengths above and below 600 nm were distinct because of the inherent difference in the interrogation region. The scattering power, which is related to the average scatterer's size, demonstrates a clear contrast between skin phototypes, skin sites, and wavelengths. We also applied venous occlusion on forearms and found that the concentrations of oxy- and deoxy-hemoglobin as assessed at wavelengths above and below 600 nm were different. Our results suggest that diffuse reflectance techniques with the visible and near infrared light sources can be employed to investigate the hemodynamics and optical properties of upper dermis and lower dermis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the 600 to 800 nm spectrum, scattering by FST V–VI was greater than the other FSTs.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“A small peak in absorption was observed at ∼970 nm for all skin types corresponding with water absorption.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“A decrease in absorption as the wavelength increased from 500 to 600 nm of twofold was observed for both skin types I–II and III–IV.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“The mean absorption coefficients for FST III–IV were greater between 500 and 600 nm (the region coinciding with high melanin absorption) than for FST I–II.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“The differences between skin types I–II and V–VI were shown to be significant for both absorption and scattering in 600 to 850 nm and 600 to 750 nm ranges, respectively.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“Measurements by Tseng et al.41 show that in the near-infrared (NIR) region of the spectrum, FSTs I–II and III–IV had very similar absorption and scattering properties.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“For FST V–VI absorption and scattering converged with the other skin types at 850 and 750 nm, respectively, indicating that the NIR is likely to be the region where FST may have less impact on optical properties.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“Scattering measurements by Tseng et al.41 for FST V–VI were greater than those measured by Saager et al.39 by twofold at 600 nm down to 18% at 900 nm.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“the maximum sample number for FST V–VI is 6.41,42,44,46,48”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“At 600 nm, absorption data published by Bosschaart et al.42 are progressively greater with increasing skin pigmentation than Tseng et al.’s41 data, being 25%, 45%, and 77% greater for FST I–II, III–IV, and V–VI, respectively.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“At 500 nm, the differences are more marked, with Bosschaart et al.’s42 data being 73% and 77% greater than Tseng et al.’s41 for FST I–II and III–IV, respectively.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“This coincides with the region discussed in Sec. 3.1 where elevated scattering by FST V–VI in the 600 to 800 nm region is attributed to the scattering power of melanosomes.41”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [41]
In the citing paper
“These authors showed that skin location and colour have important effects on measured absorption and scattering in the skin.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“Numerous authors have measured the optical properties of skin on the forearm using DRS and the absorption coefficients vary 9-fold amongst the publications from 0.01 mm-1 - 0.09 mm-1 at 700 nm [37,46,55,57,60].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“Like Tseng et al., skin location was shown to have an important effect on absorption and scattering coefficients by Doornbos et al. [55,57].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“However, their scattering and absorption profiles followed a similar pattern to the other authors’ with absorption being greatest between 500 nm and 600 nm beyond which it declines steadily with increasing wavelength except for a small peak observed at ∼970 nm.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“Similarly, measured reduced scattering coefficients have up to 10-fold variability using DRS at this wavelength, ranging from 0.184 mm-1 to 2.19 mm-1 [55,57,60,61].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“In the visible region both melanin in the epidermis and haemoglobin in the blood supply to the dermis contributed to the high absorption coefficients in some subjects.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“MC simulations were used to determine the penetration depth of photons in the skin and showed that the interrogation depth at 500 nm was at least 46% less than at 900 nm.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“At 800 nm the absorption coefficients described by Tseng et al., were 5-fold greater than those measured by Hsu et al. [55,56].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“A small peak in absorption was observed at ∼970 nm for all skin-types corresponding with water absorption.”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
In the citing paper
“Taking measurements from 18 subjects in the wavelength range 500 nm-1000 nm, Tseng et al., showed that there was a 2-fold decrease in absorption as the wavelength increased from 500 nm to 600 nm [55].”
From Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited] (2023) · cites this paper as [55]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L. V., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,330
The Protective Role of Melanin Against UV Damage in Human Skin †
Brenner, M., & Hearing, V. J. (2008) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2007.00226.x · Cited by 1,741
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M. M., Grossman, M. C., Esterowitz, D., Webb, R. H., & Anderson, R. R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,090
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Mourant, J. R., Fuselier, T., Boyer, J. D., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 530
Zonios, G., Bykowski, J., & Kollias, N. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2001.01577.x · Cited by 477
Self-citationCerussi, A. E., Shah, N. S., Hsiang, D. J. B., Durkin, A. F., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Self-citationOptical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
Troy, T. L., & Thennadil, S. N. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1344191 · Cited by 420
When does the diffusion approximation fail to describe photon transport in random media?
Yoo, K. M., Liu, F., & Alfano, R. R. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.2647 · Cited by 305
Noninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 295
In vivo absorption and scattering spectroscopy of biological tissues
Taroni, P., Pifferi, A., Torricelli, A. M., Comelli, D., & Cubeddu, R. (2003) · Photochemical & Photobiological Sciences · doi:10.1039/b209651j · Cited by 220
Zonios, G. I., & Dimou, A. D. (2006) · Optics Express · doi:10.1364/oe.14.008661 · Cited by 197
Kollias, N., Gillies, R. J., Moran, M. N., Kochevar, I. E., & Anderson, R. R. (1998) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1998.00377.x · Cited by 179
Self-citationOptical properties of human dermis in vitro and in vivo
Graaff, R., Dassel, A. C. M., Koelink, M. H., de Mul, F. F. M., Aarnoudse, J. G., & Zijlstra, W. G. (1993) · Applied Optics · doi:10.1364/ao.32.000435 · Cited by 177
Ultrastructure and Organization of the Cutaneous Microvasculature in Normal and Pathologic States.
Braverman, I. M. (1989) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12580893 · Cited by 155
Tissue water content in rats measured by desiccation
Reinoso, R. F., Telfer, B. A., & Rowland, M. (1997) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(97)00053-1 · Cited by 150
Description and Analysis of Treatments for Port-wine Stain Birthmarks
Kelly, K. M., Choi, B., McFarlane, S., Motosue, A., Jung, B., Khan, M., Ramirez-San-Juan, J. C., & Nelson, J. S. (2005) · Archives of Facial Plastic Surgery · doi:10.1001/archfaci.7.5.287 · Cited by 143
In vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy
Tseng, S.-H., Grant, A., & Durkin, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2829772 · Cited by 139
Self-citationSpectroscopic Characteristics of Human Melanin In Vivo
Kollias, N., & Baqer, A. (1985) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12275011 · Cited by 135
Self-citationNishidate, I., Aizu, Y., & Mishina, H. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1756918 · Cited by 108
Jacques, S. L., Glickman, R. D., & Schwartz, J. A. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.239608 · Cited by 104
Chang, S. K., Arifler, D., Drezek, R. A., Follen, M. M., & Richards-Kortum, R. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1695559 · Cited by 100
Zhang, R., Verkruysse, W., Choi, B., Viator, J. A., Jung, B., Svaasand, L. O., Aguilar, G., & Nelson, J. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1891147 · Cited by 95
Blood stasis contributions to the perception of skin pigmentation
Stamatas, G. N., & Kollias, N. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1647545 · Cited by 93
Self-citationWolf, U., Wolf, M., Choi, J. H., Levi, M., Choudhury, D., Hull, S., Coussirat, D. J., Paunescu, L. A., Safonova, L. P., Michalos, A., et al. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.214 · Cited by 75
A mathematical model for light dosimetry in photodynamic destruction of human endometrium
Tromberg, B. J., Svaasand, L. O., Fehr, M. K., Madsen, S. J., Wyss, P., Sansone, B., & Tadir, Y. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/2/002 · Cited by 40
Quantitative spectroscopy of superficial turbid media
Tseng, S.-H., Hayakawa, C. K., Tromberg, B. J., Spanier, J., & Durkin, A. J. (2005) · Optics Letters · doi:10.1364/ol.30.003165 · Cited by 26
Self-citationMiyamae, Y., Yamakawa, Y., Kawabata, M., & Ozaki, Y. (2008) · Applied Spectroscopy · doi:10.1366/000370208784658156 · Cited by 19
Flagged first, then by citations
Cited by
Sorted by citations
Refractive index of biological tissues: Review, measurement techniques, and applications
Khan, R., Gul, B., Khan, S., Nisar, H., & Ahmad, I. (2021) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2021.102192 · Cited by 171
Addressing racial and phenotypic bias in human neuroscience methods
Webb, E. K., Etter, J. A., & Kwasa, J. A. C. (2022) · Nature Neuroscience · doi:10.1038/s41593-022-01046-0 · Cited by 122
Multispectral in vivo three-dimensional optical coherence tomography of human skin
Alex, A., Považay, B., Höfer, B., Popov, S. V., Glittenberg, C. G., Binder, S., & Drexler, W. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3400665 · Cited by 110
Kim, A., Roy, M., Dadani, F. N., & Wilson, B. C. (2010) · Optics Express · doi:10.1364/oe.18.005580 · Cited by 101
Review of the progress toward achieving heat confinement—the holy grail of photothermal therapy
Sheng, W., He, S., Seare, W. J., & Almutairi, A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.8.080901 · Cited by 93
Metadata
- Authors
- Tseng, S.-H., Bargo, P., Durkin, A., & Kollias, N.
- Affiliations
- National Cheng Kung University (TW)
- Johnson & Johnson (United States) (US)
- University of California, Irvine (US)
- Corresponding author
- Tseng, Sheng-Hao
- ORCID
- Durkin, Anthony
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2009-08-04
- Volume
- 17
- Issue
- 17
- Pages
- 14599
- ISSN
- 1094-4087 (ISSN-L)
- PMC
- PMC2754563
- OpenAlex
- W2012728588
- Cited by
- 217
- References
- 30
- Citations by year
- 2026: 7 · 2025: 21 · 2024: 18 · 2023: 16 · 2022: 12 · 2021: 18 · 2020: 11 · 2019: 12 · 2018: 8 · 2017: 10 · 2016: 12 · 2015: 13 · 2014: 13 · 2013: 9 · 2012: 15
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Optics Express (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Center for Research Resources (P41 RR01192, P41RR001192)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- chromophore concentration, absorption coefficient, reduced scattering coefficient, oxyhemoglobin, deoxyhemoglobin, melanin, diffuse reflectance spectroscopy, Fitzpatrick skin type, venous occlusion
- MeSH terms
- Adult, Algorithms, Diffusion, Equipment Design, Hemoglobins, Humans, Melanins, Middle Aged, Oxyhemoglobins, Scattering, Radiation, Skin, Spectrophotometry, Infrared, Photons, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review