The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Rapid 3D light-sheet microscopy with a tunable lens
Open accessAbstract
The in-vivo investigation of highly dynamic biological samples, for example the beating zebrafish heart, requires high-speed volume imaging techniques. Light-sheet microscopy is ideal for such samples as it records high-contrast images of entire planes within large samples at once. However, in order to obtain images of different planes, it has been necessary to move the sample relative to the fixed focal plane of the detection objective lens. This mechanical movement limits speed, precision and may be harmful to the sample. We have built a light-sheet microscope that uses remote focusing with an electrically tunable lens (ETL). Without moving specimen or objective we have thereby achieved flexible volume imaging at much higher speeds than previously reported. Our high-speed microscope delivers 3D snapshots of sensitive biological samples. As an example, we imaged 17 planes within a beating zebrafish heart at 510 frames per second, equivalent to 30 volume scans per second. Movements, shape changes and signals across the entire volume can be followed which has been impossible with existing reconstruction techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Self-citationSelective plane illumination microscopy techniques in developmental biology
Huisken, J., & Stainier, D. Y. R. (2009) · Development · doi:10.1242/dev.022426 · Cited by 608
Self-citationFast multicolor 3D imaging using aberration-corrected multifocus microscopy
Abrahamsson, S., Chen, J., Hajj, B., Stallinga, S., Katsov, A. Y., Wisniewski, J., Mizuguchi, G., Soule, P., Mueller, F., Darzacq, C. D., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2277 · Cited by 425
Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM)
Huisken, J., & Stainier, D. Y. R. (2007) · Optics Letters · doi:10.1364/ol.32.002608 · Cited by 424
Self-citationOptically sectioned imaging by oblique plane microscopy
Dunsby, C. (2008) · Optics Express · doi:10.1364/oe.16.020306 · Cited by 348
Holekamp, T. F., Turaga, D., & Holy, T. E. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.011 · Cited by 336
Fast two-layer two-photon imaging of neuronal cell populations using an electrically tunable lens
Grewe, B. F., Voigt, F. F., van ’t Hoff, M., & Helmchen, F. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002035 · Cited by 310
Self-citationRam, S., Prabhat, P., Chao, J., Sally Ward, E., & Ober, R. J. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.140392 · Cited by 259
An optical technique for remote focusing in microscopy
Botcherby, E. J., Juskaitis, R., Booth, M. J., & Wilson, T. (2007) · Optics Communications · doi:10.1016/j.optcom.2007.10.007 · Cited by 254
Multilayer mounting enables long-term imaging of zebrafish development in a light sheet microscope
Kaufmann, A., Mickoleit, M., Weber, M., & Huisken, J. (2012) · Development · doi:10.1242/dev.082586 · Cited by 251
Self-citationPanier, T., Romano, S. A., Olive, R., Pietri, T., Sumbre, G., Candelier, R., & Debrégeas, G. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00065 · Cited by 206
Aberration-free three-dimensional multiphoton imaging of neuronal activity at kHz rates
Botcherby, E. J., Smith, C. W., Kohl, M. M., Débarre, D., Booth, M. J., Juškaitis, R., Paulsen, O., & Wilson, T. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1111662109 · Cited by 187
Liebling, M., Forouhar, A. S., Wolleschensky, R., Zimmermann, B., Ankerhold, R., Fraser, S. E., Gharib, M., & Dickinson, M. E. (2006) · Developmental Dynamics · doi:10.1002/dvdy.20926 · Cited by 126
High-speed 2D and 3D fluorescence microscopy of cardiac myocytes
Kumar, S., Wilding, D., Sikkel, M. B., Lyon, A. R., MacLeod, K. T., & Dunsby, C. W. (2011) · Optics Express · doi:10.1364/oe.19.013839 · Cited by 77
Cited by
A guide to light-sheet fluorescence microscopy for multiscale imaging
Power, R. M., & Huisken, J. (2017) · Nature Methods · doi:10.1038/nmeth.4224 · Cited by 636
Self-citationBouchard, M. B., Voleti, V., Mendes, C. S., Lacefield, C., Grueber, W. B., Mann, R. S., Bruno, R. M., & Hillman, E. M. C. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.323 · Cited by 566
In vivo imaging of neural activity
Yang, W., & Yuste, R. (2017) · Nature Methods · doi:10.1038/nmeth.4230 · Cited by 406
Light sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0
Voleti, V., Patel, K. B., Li, W., Perez Campos, C., Bharadwaj, S., Yu, H., Ford, C., Casper, M. J., Yan, R. W., Liang, W., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0579-4 · Cited by 320
Metadata
- Authors
- Fahrbach, F. O., Voigt, F. F., Schmid, B., Helmchen, F., & Huisken, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-08-30
- Volume
- 21
- Issue
- 18
- Pages
- 21010
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1964574783
- Cited by
- 347
- References
- 14
- FWCI
- 16.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.