Multicolor stimulated Raman scattering microscopy with a rapidly tunable optical parametric oscillator
Open accessThe DOI matches its Crossref record.
Abstract
Stimulated Raman scattering (SRS) microscopy allows label-free chemical imaging based on vibrational spectroscopy. Narrowband excitation with picosecond lasers creates the highest signal levels and enables imaging speeds up to video-rate, but it sacrifices chemical specificity in samples with overlapping bands compared to broadband (multiplex) excitation. We develop a rapidly tunable picosecond optical parametric oscillator with an electro-optical tunable Lyot filter, and demonstrate multicolor SRS microscopy with synchronized line-by-line wavelength tuning to avoid spectral artifacts due to sample movement. We show sensitive imaging of three different kinds of polymer beads and live HeLa cells with moving intracellular lipid droplets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of spectral imaging technology in biomedical engineering: achievements and challenges
Li, Q., He, X., Wang, Y., Liu, H., Xu, D., & Guo, F. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.100901 · Cited by 479
Coherent Raman spectro-imaging with laser frequency combs
Ideguchi, T., Holzner, S., Bernhardt, B., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2013) · Nature · doi:10.1038/nature12607 · Cited by 475
Chemically sensitive bioimaging with coherent Raman scattering
Camp Jr, C. H., & Cicerone, M. T. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.60 · Cited by 472
High-speed coherent Raman fingerprint imaging of biological tissues
Camp Jr, C. H., Lee, Y. J., Heddleston, J. M., Hartshorn, C. M., Walker, A. R. H., Rich, J. N., Lathia, J. D., & Cicerone, M. T. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.145 · Cited by 469
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Biological imaging of chemical bonds by stimulated Raman scattering microscopy
Hu, F., Shi, L., & Min, W. (2019) · Nature Methods · doi:10.1038/s41592-019-0538-0 · Cited by 392
Stimulated Raman scattering microscopy with a robust fibre laser source
Freudiger, C. W., Yang, W., Holtom, G. R., Peyghambarian, N., Xie, X. S., & Kieu, K. Q. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.360 · Cited by 345
Self-citationFast Vibrational Imaging of Single Cells and Tissues by Stimulated Raman Scattering Microscopy
Zhang, D., Wang, P., Slipchenko, M. N., & Cheng, J.-X. (2014) · Accounts of Chemical Research · doi:10.1021/ar400331q · Cited by 167
Shedding new light on lipid functions with CARS and SRS microscopy
Yu, Y., Ramachandran, P. V., & Wang, M. C. (2014) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2014.02.003 · Cited by 89
Metadata
- Authors
- Kong, L., Ji, M., Holtom, G. R., Fu, D., Freudiger, C. W., & Xie, X. S.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2013-01-08
- Volume
- 38
- Issue
- 2
- Pages
- 145
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1985376284
- Cited by
- 99
- References
- 0
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.