Cited by 44Advanced Sensor and Energy Harvesting MaterialsLuminescence Properties of Advanced MaterialsAdvanced Fiber Optic Sensors

Stretchable and upconversion-luminescent polymeric optical sensor for wearable multifunctional sensing

Guo, Jingjing, Zhou, Bingqian, Yang, Changxi, Dai, Qionghai, Kong, Lingjie·2019·Optics Letters

Abstract

Stretchable sensors with multiple sensory functions are in high demand for healthcare monitoring and artificial intelligence. Despite recent advances in wearable electronic sensors, it remains a significant challenge to achieve simultaneous sensing of both thermal and mechanical stimuli with a single sensor while integrating high stretchability. Herein, a stretchable and multifunctional optical sensor (SMOS) with simultaneous readout of temperature and strain is developed for wearable physiological monitoring of the human body. The SMOS primarily consists of a stretchable optical sensing fiber made from polymer nanocomposites containing lanthanide-based upconversion nanoparticles (UCNPs). Temperature measurements are achieved by ratiometric intensity measurements of the dual-emission UCNPs upon near-infrared excitation. By virtue of the ratiometric detection, the temperature readout of the SMOS is independent of strain deformations, enabling stable and continuous measurements of skin temperature during body motions. Furthermore, deformation of the SMOS by stretching leads to detectable and reversible changes in its light transmission, allowing tensile strains to be simultaneously measured. As a proof of concept, we demonstrate the capabilities of the SMOS in real time and simultaneous detection of both skin temperature and motion activities of the human body.

Integrity signals

Registry

Crossref · 10.1364/ol.44.005747

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Guo et al. presented a stretchable and multifunctional optical sensor with simultaneous readout of body temperature and strain for wearable physiological monitoring of the human body.

    “Guo et al. [319] presented a stretchable and multifunctional optical sensor (SMOS) with simultaneous readout of BT and strain for wearable physiological monitoring of the human body.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [319]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Guo, J., Zhou, B., Yang, C., Dai, Q., & Kong, L.
Affiliations
Tsinghua University (CN)
Venue
Optics Letters
Published
2019-11-27
Volume
44
Issue
23
Pages
5747
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W2990556001
Cited by
44
References
23
Citations by year
2026: 4 · 2025: 6 · 2024: 10 · 2023: 7 · 2022: 10 · 2021: 5 · 2020: 2
FWCI
1.50
Type
journal article
Language
en
Open access
closed
Locations
  • Optics Letters (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (61805126)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence Properties of Advanced Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
Keywords
upconversion nanoparticles, lanthanide nanoparticles, polymer nanocomposites, ratiometric thermometry, strain sensing, wearable sensors, skin temperature monitoring, multifunctional sensing, near-infrared excitation, fiber optic sensors, physiological monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review