Three-photon neuronal imaging in deep mouse brain
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Three-photon microscopy has been increasingly adopted for probing neural activities beyond the typical two-photon imaging depth. In this review, we outline the unique properties that differentiate three-photon microscopy from two-photon microscopy for in vivo imaging in biological samples, especially in the mouse brain. We present a systematic summary of the optimization of three-photon imaging parameters for neural imaging, based on their effects on calcium imaging quality and perturbation to brain tissues. Furthermore, we review the existing techniques for volumetric imaging and discuss their prospects in mesoscale three-photon imaging in deep tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
A century of trends in adult human height
NCD Risk Factor Collaboration (NCD-RisC) (2016) · eLife · doi:10.7554/elife.13410 · Cited by 1,558
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Self-citationFunctional imaging of hippocampal place cells at cellular resolution during virtual navigation
Dombeck, D. A., Harvey, C. D., Tian, L., Looger, L. L., & Tank, D. W. (2010) · Nature Neuroscience · doi:10.1038/nn.2648 · Cited by 873
Impermanence of dendritic spines in live adult CA1 hippocampus
Attardo, A., Fitzgerald, J. E., & Schnitzer, M. J. (2015) · Nature · doi:10.1038/nature14467 · Cited by 399
Cited by
Streich, L., Boffi, J. C., Wang, L., Alhalaseh, K., Barbieri, M., Rehm, R., Deivasigamani, S., Gross, C. T., Agarwal, A., & Prevedel, R. (2021) · Nature Methods · doi:10.1038/s41592-021-01257-6 · Cited by 185
Multiphoton fluorescence microscopy for in vivo imaging
Xu, C., Nedergaard, M., Fowell, D. J., Friedl, P., & Ji, N. (2024) · Cell · doi:10.1016/j.cell.2024.07.036 · Cited by 165
Self-citationFluorescence imaging of large-scale neural ensemble dynamics
Kim, T. H., & Schnitzer, M. J. (2022) · Cell · doi:10.1016/j.cell.2021.12.007 · Cited by 159
“Notwithstanding its virtues for deep imaging, three-photonmicroscopy involves challenges related to the difficulty of generating three-photon excitation (Wang and Xu, 2020; Yildirim et al., 2019).”
BackgroundMethodInfluentialLi, D., Deng, X., Xu, Z., Wang, D., Xu, G., Zhang, P., Qiu, P., Xie, W., Wang, D., Tang, B. Z., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202303967 · Cited by 63
Metadata
- Authors
- Wang, T., & Xu, C.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2020-08-07
- Volume
- 7
- Issue
- 8
- Pages
- 947
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W3041600666
- Cited by
- 176
- References
- 7
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.