Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
One of the challenges of using Raman spectroscopy for biological applications is the inherent fluorescence generated by many biological molecules that underlies the measured spectra. This fluorescence can sometimes be several orders of magnitude more intense than the weak Raman scatter, and its presence must be minimized in order to resolve and analyze the Raman spectrum. Several techniques involving hardware and software have been devised for this purpose; these include the use of wavelength shifting, time gating, frequency-domain filtering, first- and second-order derivatives, and simple curve fitting of the broadband variation with a high-order polynomial. Of these, polynomial fitting has been found to be a simple but effective method. However, this technique typically requires user intervention and thus is time consuming and prone to variability. An automated method for fluorescence subtraction, based on a modification to least-squares polynomial curve fitting, is described. Results indicate that the presented automated method is proficient in fluorescence subtraction, repeatability, and in retention of Raman spectral lineshapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near‐Infrared Raman Spectroscopy for In Vitro Detection of Cervical Precancers
Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujamf, N., Malpica, A., Thomsen, S., Utzinger, U., & Richards‐Kortumt, R. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb03262.x · Cited by 282
Self-citationBarclay, V. J., Bonner, R. F., & Hamilton, I. P. (1997) · Analytical Chemistry · doi:10.1021/ac960638m · Cited by 253
Mosier-Boss, P. A., Lieberman, S. H., & Newbery, R. (1995) · Applied Spectroscopy · doi:10.1366/0003702953964039 · Cited by 221
Automated Fluorescence Rejection Using Shifted Excitation Raman Difference Spectroscopy
Zhao, J., Carrabba, M. M., & Allen, F. S. (2002) · Applied Spectroscopy · doi:10.1366/000370202760171491 · Cited by 186
Duyne, R. P. V., Jeanmaire, D. L., & Shriver, D. F. (1974) · Analytical Chemistry · doi:10.1021/ac60338a012 · Cited by 141
Near-Infrared Raman Spectrometer Systems for Human Tissue Studies
Brennan, J. F., Wang, Y., Dasari, R. R., & Feld, M. S. (1997) · Applied Spectroscopy · doi:10.1366/0003702971940134 · Cited by 126
O'Grady, A., Dennis, A. C., Denvir, D. J., McGarvey, J. J., & Bell, S. E. J. (2001) · Analytical Chemistry · doi:10.1021/ac0010072 · Cited by 97
Curve Fitting and Linearity: Data Processing in Raman Spectroscopy
Vickers, T. J., Wambles, R. E., & Mann, C. K. (2001) · Applied Spectroscopy · doi:10.1366/0003702011952127 · Cited by 82
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
“For a simple Raman signal like a Raman spectrum of a non-fluorescent solid compound, a straight line fit through a couple of points could be sufficient enough, whereas for a complex Raman signal like a Raman spectrum of tissues/cells one might need many base points along with a fifth-order or higher polynomial fit [24…”
BackgroundHigh-fat diet alters gut microbiota physiology in mice
Daniel, H., Gholami, A. M., Berry, D., Desmarchelier, C., Hahne, H., Loh, G., Mondot, S., Lepage, P., Rothballer, M., Walker, A., et al. (2014) · The ISME Journal · doi:10.1038/ismej.2013.155 · Cited by 678
Metadata
- Authors
- Lieber, C. A., & Mahadevan-Jansen, A.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2003-11
- Volume
- 57
- Issue
- 11
- Pages
- 1363-1367
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2127673401
- Cited by
- 1,049
- References
- 8
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.