Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
One of the challenges of using Raman spectroscopy for biological applications is the inherent fluorescence generated by many biological molecules that underlies the measured spectra. This fluorescence can sometimes be several orders of magnitude more intense than the weak Raman scatter, and its presence must be minimized in order to resolve and analyze the Raman spectrum. Several techniques involving hardware and software have been devised for this purpose; these include the use of wavelength shifting, time gating, frequency-domain filtering, first- and second-order derivatives, and simple curve fitting of the broadband variation with a high-order polynomial. Of these, polynomial fitting has been found to be a simple but effective method. However, this technique typically requires user intervention and thus is time consuming and prone to variability. An automated method for fluorescence subtraction, based on a modification to least-squares polynomial curve fitting, is described. Results indicate that the presented automated method is proficient in fluorescence subtraction, repeatability, and in retention of Raman spectral lineshapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near‐Infrared Raman Spectroscopy for In Vitro Detection of Cervical Precancers
Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujamf, N., Malpica, A., Thomsen, S., Utzinger, U., & Richards‐Kortumt, R. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb03262.x · Cited by 282
Self-citationBarclay, V. J., Bonner, R. F., & Hamilton, I. P. (1997) · Analytical Chemistry · doi:10.1021/ac960638m · Cited by 253
Mosier-Boss, P. A., Lieberman, S. H., & Newbery, R. (1995) · Applied Spectroscopy · doi:10.1366/0003702953964039 · Cited by 221
Automated Fluorescence Rejection Using Shifted Excitation Raman Difference Spectroscopy
Zhao, J., Carrabba, M. M., & Allen, F. S. (2002) · Applied Spectroscopy · doi:10.1366/000370202760171491 · Cited by 186
Duyne, R. P. V., Jeanmaire, D. L., & Shriver, D. F. (1974) · Analytical Chemistry · doi:10.1021/ac60338a012 · Cited by 141
Near-Infrared Raman Spectrometer Systems for Human Tissue Studies
Brennan, J. F., Wang, Y., Dasari, R. R., & Feld, M. S. (1997) · Applied Spectroscopy · doi:10.1366/0003702971940134 · Cited by 126
O'Grady, A., Dennis, A. C., Denvir, D. J., McGarvey, J. J., & Bell, S. E. J. (2001) · Analytical Chemistry · doi:10.1021/ac0010072 · Cited by 97
Curve Fitting and Linearity: Data Processing in Raman Spectroscopy
Vickers, T. J., Wambles, R. E., & Mann, C. K. (2001) · Applied Spectroscopy · doi:10.1366/0003702011952127 · Cited by 82
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
“For a simple Raman signal like a Raman spectrum of a non-fluorescent solid compound, a straight line fit through a couple of points could be sufficient enough, whereas for a complex Raman signal like a Raman spectrum of tissues/cells one might need many base points along with a fifth-order or higher polynomial fit [24…”
BackgroundHigh-fat diet alters gut microbiota physiology in mice
Daniel, H., Gholami, A. M., Berry, D., Desmarchelier, C., Hahne, H., Loh, G., Mondot, S., Lepage, P., Rothballer, M., Walker, A., et al. (2014) · The ISME Journal · doi:10.1038/ismej.2013.155 · Cited by 678
Choy, C. A., Robison, B. H., Gagne, T. O., Erwin, B., Firl, E., Halden, R. U., Hamilton, J. A., Katija, K., Lisin, S. E., Rolsky, C., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-44117-2 · Cited by 560
Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy
Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053641450 · Cited by 548
Deep convolutional neural networks for Raman spectrum recognition: a unified solution
Liu, J., Osadchy, M., Ashton, L., Foster, M., Solomon, C. J., & Gibson, S. J. (2017) · The Analyst · doi:10.1039/c7an01371j · Cited by 507
Label-free Raman observation of cytochrome c dynamics during apoptosis
Okada, M., Smith, N. I., Palonpon, A. F., Endo, H., Kawata, S., Sodeoka, M., & Fujita, K. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1107524108 · Cited by 478
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Raman and SERS microscopy for molecular imaging of live cells
Palonpon, A. F., Ando, J., Yamakoshi, H., Dodo, K., Sodeoka, M., Kawata, S., & Fujita, K. (2013) · Nature Protocols · doi:10.1038/nprot.2013.030 · Cited by 377
Guo, S., Popp, J., & Bocklitz, T. (2021) · Nature Protocols · doi:10.1038/s41596-021-00620-3 · Cited by 361
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Self-citationLemaître, G., Martí, R., Freixenet, J., Vilanova, J. C., Walker, P. M., & Meriaudeau, F. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.02.009 · Cited by 348
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334
Optimal Choice of Baseline Correction for Multivariate Calibration of Spectra
Liland, K. H., Almøy, T., & Mevik, B.-H. (2010) · Applied Spectroscopy · doi:10.1366/000370210792434350 · Cited by 317
Raman microscopy for dynamic molecular imaging of living cells
Hamada, K., Fujita, K., Smith, N. I., Kobayashi, M., Inouye, Y., & Kawata, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2952192 · Cited by 316
Background removal from spectra by designing and minimising a non-quadratic cost function
Mazet, V., Carteret, C., Brie, D., Idier, J., & Humbert, B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.10.003 · Cited by 316
Investigation of Selected Baseline Removal Techniques as Candidates for Automated Implementation
Schulze, G., Jirasek, A., Yu, M. M. L., Lim, A., Turner, R. F. B., & Blades, M. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053945985 · Cited by 315
Cowger, W., Gray, A., Christiansen, S. H., DeFrond, H., Deshpande, A. D., Hemabessiere, L., Lee, E., Mill, L., Munno, K., Ossmann, B. E., et al. (2020) · Applied Spectroscopy · doi:10.1177/0003702820929064 · Cited by 302
Raman Spectroscopy Detects Biochemical Changes Due to Proliferation in Mammalian Cell Cultures
Short, K. W., Carpenter, S., Freyer, J. P., & Mourant, J. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.103.038604 · Cited by 286
How to pre-process Raman spectra for reliable and stable models?
Bocklitz, T., Walter, A., Hartmann, K., Rösch, P., & Popp, J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.043 · Cited by 282
Raman Spectroscopy for the Analysis of Microplastics in Aquatic Systems
Nava, V., Frezzotti, M. L., & Leoni, B. (2021) · Applied Spectroscopy · doi:10.1177/00037028211043119 · Cited by 280
Ravikanth, L., Jayas, D. S., White, N. D. G., Fields, P. G., & Sun, D.-W. (2017) · Food and Bioprocess Technology · doi:10.1007/s11947-016-1817-8 · Cited by 279
Extended multiplicative signal correction in vibrational spectroscopy, a tutorial
Afseth, N. K., & Kohler, A. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.004 · Cited by 263
Raman spectroscopy coupled with chemometrics for food authentication: A review
Xu, Y., Zhong, P., Jiang, A., Shen, X., Li, X., Xu, Z., Shen, Y., Sun, Y., & Lei, H. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116017 · Cited by 244
Liland, K. H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.02.007 · Cited by 242
Bonnier, F., & Byrne, H. J. (2012) · The Analyst · doi:10.1039/c1an15821j · Cited by 237
In vivo nonmelanoma skin cancer diagnosis using Raman microspectroscopy
Lieber, C. A., Majumder, S. K., Ellis, D. L., Billheimer, D. D., & Mahadevan‐Jansen, A. (2008) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20653 · Cited by 218
“High frequency spectral noise was removed with a 2nd order Savitzky-Golay filter (17) with a window size of two-times the spectral resolution, and broadband tissue autofluorescence was subtracted using an automated polynomial fitting technique.(18)”
MethodSelf-citationRaman Spectra of Biological Samples: A Study of Preprocessing Methods
Afseth, N. K., Segtnan, V. H., & Wold, J. P. (2006) · Applied Spectroscopy · doi:10.1366/000370206779321454 · Cited by 205
In Vivo Bladder Cancer Diagnosis by High-Volume Raman Spectroscopy
Draga, R. O. P., Grimbergen, M. C. M., Vijverberg, P. L. M., Swol, C. F. P. V., Jonges, T. G. N., Kummer, J. A., & Ruud Bosch, J. L. H. (2010) · Analytical Chemistry · doi:10.1021/ac100448p · Cited by 196
Keller, M. D., Vargis, E., de Matos Granja, N., Wilson, R. H., Mycek, M.-A., Kelley, M. C., & Mahadevan-Jansen, A. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3600708 · Cited by 194
Self-citationAssessment tools for microplastics and natural fibres ingested by fish in an urbanised estuary
Halstead, J. E., Smith, J. A., Carter, E. A., Lay, P. A., & Johnston, E. L. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2017.11.085 · Cited by 188
Chan, J. W., Lieu, D. K., Huser, T., & Li, R. A. (2009) · Analytical Chemistry · doi:10.1021/ac801665m · Cited by 187
Eliasson, C., & Matousek, P. (2007) · Analytical Chemistry · doi:10.1021/ac062223z · Cited by 186
Raman technologies in cancer diagnostics
Austin, L. A., Osseiran, S., & Evans, C. L. (2016) · The Analyst · doi:10.1039/c5an01786f · Cited by 182
In vivo diagnostics of early abiotic plant stress response via Raman spectroscopy
Altangerel, N., Ariunbold, G. O., Gorman, C., Alkahtani, M. H., Borrego, E. J., Bohlmeyer, D., Hemmer, P., Kolomiets, M. V., Yuan, J. S., & Scully, M. O. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701328114 · Cited by 168
“The baselines of Raman raw spectral data were corrected by fitting the high-order polynomials with multiple iterations (27).”
MethodDingari, N. C., Horowitz, G. L., Kang, J. W., Dasari, R. R., & Barman, I. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032406 · Cited by 168
Deep non-invasive Raman spectroscopy of living tissue and powders
Matousek, P. (2007) · Chemical Society Reviews · doi:10.1039/b614777c · Cited by 165
Raman microspectroscopy for microbiology
Lee, K. S., Landry, Z., Pereira, F. C., Wagner, M., Berry, D., Huang, W. E., Taylor, G. T., Kneipp, J., Popp, J., Zhang, M., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00075-6 · Cited by 161
Pretreating and normalizing metabolomics data for statistical analysis
Sun, J., & Xia, Y. (2024) · Genes & Diseases · doi:10.1016/j.gendis.2023.04.018 · Cited by 158
Meran, L., Massie, I., Campinoti, S., Weston, A. E., Gaifulina, R., Tullie, L., Faull, P., Orford, M., Kucharska, A., Baulies, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1024-z · Cited by 143
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
“accumulation of cells or cellular metabolism components within the system; however, the exact identity of compounds responsible for this is currently unknown to the authors.(37,38)”
BackgroundLloyd, G. R., Orr, L. E., Christie-Brown, J., McCarthy, K., Rose, S., Thomas, M., & Stone, N. (2013) · The Analyst · doi:10.1039/c2an36579k · Cited by 83
Analyzing Raman spectroscopic data
Ryabchykov, O., Guo, S., & Bocklitz, T. (2019) · Physical Sciences Reviews · doi:10.1515/psr-2017-0043 · Cited by 74
Towards the in vivo prediction of fragility fractures with Raman spectroscopy
Buckley, K., Kerns, J. G., Vinton, J., Gikas, P. D., Smith, C., Parker, A. W., Matousek, P., & Goodship, A. E. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4706 · Cited by 68
Cordero, E., Korinth, F., Stiebing, C., Krafft, C., Schie, I., & Popp, J. (2017) · Sensors · doi:10.3390/s17081724 · Cited by 58
“Computational methods include, for example, polynomial fitting [21], different least squares methods [22] and extended multiplicative scatter correction (EMSC) [23].”
MethodNovel method to analyze post-yield mechanical properties at trabecular bone tissue level
Carretta, R., Luisier, B., Bernoulli, D., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.12.003 · Cited by 43
Kichou, H., Bonnier, F., Dancik, Y., Bakar, J., Michael-Jubeli, R., Caritá, A. C., Perse, X., Soucé, M., Rapetti, L., Tfayli, A., et al. (2023) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2023.123488 · Cited by 42
A Hybrid Least Squares and Principal Component Analysis Algorithm for Raman Spectroscopy
Van de Sompel, D., Garai, E., Zavaleta, C., & Gambhir, S. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038850 · Cited by 39
Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2015) · BioMed Research International · doi:10.1155/2015/457371 · Cited by 14
Korinth, F., Schmälzlin, E., Stiebing, C., Urrutia, T., Micheva, G., Sandin, C., Müller, A., Maiwald, M., Sumpf, B., Krafft, C., et al. (2020) · Sensors · doi:10.3390/s20236723 · Cited by 13
“Computational methods correct Raman spectra for their background using mathematical algorithms such as extended multiplicative scatter correction (EMSC) [9,10], rubberband [11,12], sensitive nonlinear iterative peak (SNIP) [13,14], and polynomial fittings [15].”
MethodShang, L., Bao, X., Peng, H., Chen, F., Wang, Y., Liu, K., Liang, P., Wang, Y., Tang, X., Masia, F., et al. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-02020-8 · Cited by 4
“One signi fi cant limitation is fl uorescence background 17,18 , which can overwhelm Raman scattering.”
Metadata
- Authors
- Lieber, C. A., & Mahadevan-Jansen, A.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2003-11
- Volume
- 57
- Issue
- 11
- Pages
- 1363-1367
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2127673401
- Cited by
- 1,049
- References
- 8
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.