The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy
Abstract
This paper reports in situ noninvasive blood glucose monitoring by use of near-infrared (NIR) diffuse-reflectance spectroscopy. The NIR spectra of the human forearm were measured in vivo by using a pair of source and detector optical fibers separated by a distance of 0.65 mm on the skin surface. This optical geometry enables the selective measurement of dermis tissue spectra due to the skin's optical properties and reduces the interference noise arising from the stratum corneum. Oral glucose intake experiments were performed with six subjects (including a single subject with type I diabetes) whose NIR skin spectra were measured at the forearm. Partial least-squares regression (PLSR) analysis was carried out and calibration equations were obtained with each subject individually. Without exception among the six subjects, the regression coefficient vectors of their calibration models were similar to each other and had a positive peak at around 1600 nm, corresponding to the characteristic absorption peak of glucose. This result indicates that there is every possibility of glucose detection in skin tissue using our measurement system. We also found that there was a good correlation between the optically predicted values and the directly measured values of blood samples with individual subjects. The potential of noninvasive blood glucose monitoring using our methodology was demonstrated by the present study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Research works printed but not linked: 23
- 10.1093/clinchem/45.2.165 · DOI · Paper page
- 10.1093/jn/131.5.1596S · DOI
- 10.1093/clinchem/38.9.1618 · DOI · Paper page
- 10.1055/s-2000-8137 · doi:10.1055/s-2000-8137
- 10.1255/jnirs.156 · doi:10.1255/jnirs.156
- 10.1002/jrs.871 · DOI
- 10.1089/152091599317341 · DOI
- 10.1007/BF02446645 · DOI
- Heise H. M., 2002, Near-Infrared Spectroscopy, 289
- Heise H. M., 1997, Biosensors in the Body Continuous in vivo Monitoring, 79
- 10.1021/ac9710801 · DOI
- 10.1016/S0022-2143(97)90044-5 · DOI
- Iino K., Maruo K., Yamada Y., Proc. Asian Symp. Biomed. Opt. Photomedicine (Sapporo, Japan), pp. 232, 233 (2002).
- Maruo K., 2001, First Diabetes Technology Meeting, 33
- Maruo K., 2002, Proc. SPIE-Int. Soc. Opt. Eng., 4624, 20
- 10.1366/0003702991946046 · DOI
- Reeves J. B., 1994, J. AOCA Int., 77, 814, 10.1093/jaoac/77.4.814 · doi:10.1093/jaoac/77.4.814
- Maruo K., Oka M., U.S. Patent 5,957,841 (1999).
- Maruo K., Shimizu K., Oka M., U. S. Patent 6,016,435 (2000).
- 10.2337/diacare.8.6.529 · DOI · Paper page
- 10.2337/diacare.10.5.622 · DOI · Paper page
- 10.1366/0003702981943103 · DOI
- Arimoto H., Tarumi M., Yamada Y., Proc. Asian Symp. Biomed. Opt. Photomedicine (Sapporo, Japan), pp. 214–215 (2002).
Cited by
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Metadata
- Authors
- Maruo, K., Tsurugi, M., Tamura, M., & Ozaki, Y.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 57
- Issue
- 10
- Pages
- 1236-1244
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2012508783
- Cited by
- 162
- References
- 1
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy. https://app.cochat.ai/papers/10.1366/000370203769699090
- The paper
- Maruo, K., Tsurugi, M., Tamura, M., & Ozaki, Y. (2003). In Vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy. Applied Spectroscopy. https://doi.org/10.1366/000370203769699090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.