In Vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
This paper reports in situ noninvasive blood glucose monitoring by use of near-infrared (NIR) diffuse-reflectance spectroscopy. The NIR spectra of the human forearm were measured in vivo by using a pair of source and detector optical fibers separated by a distance of 0.65 mm on the skin surface. This optical geometry enables the selective measurement of dermis tissue spectra due to the skin's optical properties and reduces the interference noise arising from the stratum corneum. Oral glucose intake experiments were performed with six subjects (including a single subject with type I diabetes) whose NIR skin spectra were measured at the forearm. Partial least-squares regression (PLSR) analysis was carried out and calibration equations were obtained with each subject individually. Without exception among the six subjects, the regression coefficient vectors of their calibration models were similar to each other and had a positive peak at around 1600 nm, corresponding to the characteristic absorption peak of glucose. This result indicates that there is every possibility of glucose detection in skin tissue using our measurement system. We also found that there was a good correlation between the optically predicted values and the directly measured values of blood samples with individual subjects. The potential of noninvasive blood glucose monitoring using our methodology was demonstrated by the present study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Overview of Evolutionary Algorithms in Multiobjective Optimization
Fonseca, C. M., & Fleming, P. J. (1995) · Evolutionary Computation · doi:10.1162/evco.1995.3.1.1 · Cited by 2,266
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Orthogonal signal correction of near-infrared spectra
Wold, S., Antti, H., Lindgren, F., & Öhman, J. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00109-9 · Cited by 1,089
Jiang, J., Berry, R. J., Siesler, H. W., & Ozaki, Y. (2002) · Analytical Chemistry · doi:10.1021/ac011177u · Cited by 461
Self-citationSpectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Noninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation
Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1618 · Cited by 284
Du, Y. P., Liang, Y., Jiang, J., Berry, R. J., & Ozaki, Y. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.041 · Cited by 248
Self-citationAccuracy of Perceiving Blood Glucose in IDDM
Cox, D. J., Clarke, W. L., Gonder-Frederick, L., Pohl, S., Hoover, C., Snyder, A., Zimbelman, L., Carter, W. R., Bobbitt, S., & Pennebaker, J. (1985) · Diabetes Care · doi:10.2337/diacare.8.6.529 · Cited by 169
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Marbach, R., Koschinsky, T., Gries, F. A., & Heise, H. M. (1993) · Applied Spectroscopy · doi:10.1366/0003702934415354 · Cited by 164
Research works printed but not linked: 8
- 10.1255/jnirs.156 · doi:10.1255/jnirs.156
- Iino K., Maruo K., Yamada Y., Proc. Asian Symp. Biomed. Opt. Photomedicine (Sapporo, Japan), pp. 232, 233 (2002).
- Maruo K., 2001, First Diabetes Technology Meeting, 33
- Maruo K., 2002, Proc. SPIE-Int. Soc. Opt. Eng., 4624, 20
- Reeves J. B., 1994, J. AOCA Int., 77, 814, 10.1093/jaoac/77.4.814 · doi:10.1093/jaoac/77.4.814
- Maruo K., Oka M., U.S. Patent 5,957,841 (1999).
- Maruo K., Shimizu K., Oka M., U. S. Patent 6,016,435 (2000).
- Arimoto H., Tarumi M., Yamada Y., Proc. Asian Symp. Biomed. Opt. Photomedicine (Sapporo, Japan), pp. 214–215 (2002).
Cited by
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Near-Infrared Spectroscopy—Its Versatility in Analytical Chemistry
Ozaki, Y. (2012) · Analytical Sciences · doi:10.2116/analsci.28.545 · Cited by 283
Self-citationNon-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Near-infrared spectroscopy for medical applications: Current status and future perspectives
Sakudo, A. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.02.009 · Cited by 248
Tissue optical immersion clearing
Genina, E. A., Bashkatov, A. N., & Tuchin, V. V. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.50 · Cited by 208
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Recent Advances in Application of Biosensors in Tissue Engineering
Hasan, A., Nurunnabi, M., Morshed, M., Paul, A., Polini, A., Kuila, T., Al Hariri, M., Lee, Y.-K., & Jaffa, A. A. (2014) · BioMed Research International · doi:10.1155/2014/307519 · Cited by 192
“In the contrary, polarimetry [42, 43], diffuse reflection spectroscopy [44, 45], absorption/transmission spectroscopy [46, 47], thermal emission spectroscopy [48, 49], photoacoustic spectroscopy [50], and near-infrared spectroscopy (NIRS) [51–53] have demonstrated promising successes in measuring blood glucose levels…”
BackgroundStuart, D. A., Yonzon, C. R., Zhang, X., Lyandres, O., Shah, N. C., Glucksberg, M. R., Walsh, J. T., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac0501238 · Cited by 182
Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Sim, J. Y., Ahn, C.-G., Jeong, E.-J., & Kim, B. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-19340-y · Cited by 161
Metadata
- Authors
- Maruo, K., Tsurugi, M., Tamura, M., & Ozaki, Y.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 57
- Issue
- 10
- Pages
- 1236-1244
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2012508783
- Cited by
- 162
- References
- 30
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.