Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
A significant advantage of Raman spectroscopy as a noninvasive optical technique is its ability to detect subtle molecular or biochemical signatures within tissue. One of the major challenges for biomedical Raman spectroscopy is the removal of intrinsic autofluorescence background signals, which are usually a few orders of magnitude stronger than those arising from Raman scattering. A number of methods have been proposed for fluorescence background removal including excitation wavelength shifting, Fourier transformation, time gating, and simple or modified polynomial fitting. The single polynomial and the modified multi-polynomial fitting methods are relatively simple and effective, and thus are widely used in biological applications. However, their performance in real-time in vivo applications and low signal-to-noise ratio environments is sub-optimal. An improved automated algorithm for fluorescence removal has been developed based on modified multi-polynomial fitting, but with the addition of (1) a peak-removal procedure during the first iteration, and (2) a statistical method to account for signal noise effects. Experimental results demonstrate that this approach improves the automated rejection of the fluorescence background during real-time Raman spectroscopy and for in vivo measurements characterized by low signal-to-noise ratios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Self-citationRaman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Combined In Vivo Confocal Raman Spectroscopy and Confocal Microscopy of Human Skin
Caspers, P. J., Lucassen, G. W., & Puppels, G. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74501-9 · Cited by 446
Investigation of Selected Baseline Removal Techniques as Candidates for Automated Implementation
Schulze, G., Jirasek, A., Yu, M. M. L., Lim, A., Turner, R. F. B., & Blades, M. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053945985 · Cited by 315
In vitro andin vivo Raman spectroscopy of human skin
Caspers, P. J., Lucassen, G. W., Wolthuis, R., Bruining, H. A., & Puppels, G. J. (1998) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1998)4:5+<s31::aid-bspy4>3.0.co;2-m · Cited by 314
Shreve, A. P., Cherepy, N. J., & Mathies, R. A. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125122 · Cited by 312
Raman spectroscopy for noninvasive glucose measurements
Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W.-C., Sasic, S., Horowitz, G. L., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920212 · Cited by 271
Raman spectroscopy of in vivo cutaneous melanin
Huang, Z., Lui, H., Chen, X. K., Alajlan, A., McLean, D. I., & Zeng, H. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1805553 · Cited by 248
Self-citationMosier-Boss, P. A., Lieberman, S. H., & Newbery, R. (1995) · Applied Spectroscopy · doi:10.1366/0003702953964039 · Cited by 221
Rapid near-infrared Raman spectroscopy system for real-time in vivo skin measurements
Huang, Z., Zeng, H., Hamzavi, I., McLean, D. I., & Lui, H. (2001) · Optics Letters · doi:10.1364/ol.26.001782 · Cited by 197
Self-citationDevelopment of a Fiber Optic Probe to Measure NIR Raman Spectra of Cervical Tissue In Vivo
Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujam, N., Utzinger, U., & Richards‐Kortum, R. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb09703.x · Cited by 192
Development of a Fiber Optic Probe to Measure NIR Raman Spectra of Cervical Tissue In Vivo
Mahadevan-Jansen, A., Mitchell, M. F., Ramanujam, N., Utzinger, U., & Richards-Kortum, R. (1998) · Photochemistry and Photobiology · doi:10.1562/0031-8655(1998)068<0427:doafop>2.3.co;2 · Cited by 168
In vivo Raman spectral pathology of human atherosclerosis and vulnerable plaque
Motz, J. T., Fitzmaurice, M., Miller, A., Gandhi, S. J., Haka, A. S., Galindo, L. H., Dasari, R. R., Kramer, J. R., & Feld, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2190967 · Cited by 151
Real-time Raman system for in vivo disease diagnosis
Motz, J. T., Gandhi, S. J., Scepanovic, O. R., Haka, A. S., Kramer, J. R., Dasari, R. R., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920247 · Cited by 139
Development of anIn Vivo Raman Spectroscopic System for Diagnostic Applications
Shim, M. G., & Wilson, B. C. (1997) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199702)28:2/3<131::aid-jrs68>3.0.co;2-s · Cited by 132
Rapid Near-Infrared Raman Spectroscopy of Human Tissue with a Spectrograph and CCD Detector
Baraga, J. J., Feld, M. S., & Rava, R. P. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125555 · Cited by 130
Near-Infrared Raman Spectrometer Systems for Human Tissue Studies
Brennan, J. F., Wang, Y., Dasari, R. R., & Feld, M. S. (1997) · Applied Spectroscopy · doi:10.1366/0003702971940134 · Cited by 126
In vivo chemical investigation of human skin using a confocal Raman fiber optic microprobe
Chrit, L., Hadjur, C., Morel, S., Sockalingum, G. D., Bourdon, G. L., Leroy, F., & Manfait, M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2003747 · Cited by 95
Analysis of luminescent samples using subtracted shifted Raman spectroscopy
Bell, S. E. J., Bourguignon, E., & Dennis, A. C. (1998) · The Analyst · doi:10.1039/a802802h · Cited by 86
Glucose determination in human aqueous humor with Raman spectroscopy
Lambert, J. L., Pelletier, C. C., & Borchert, M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1914843 · Cited by 80
Kerr-gated time-resolved Raman spectroscopy of equine cortical bone tissue
Morris, M. D., Matousek, P., Towrie, M., Parker, A. W., Goodship, A. E., & Draper, E. R. C. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1827605 · Cited by 63
Simple Reconstruction Algorithm for Shifted Excitation Raman Difference Spectroscopy
Matousek, P., Towrie, M., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702054280757 · Cited by 55
Cited by
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Intraoperative brain cancer detection with Raman spectroscopy in humans
Jermyn, M., Mok, K., Mercier, J., Desroches, J., Pichette, J., Saint-Arnaud, K., Bernstein, L., Guiot, M.-C., Petrecca, K., & Leblond, F. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2384 · Cited by 618
Microplastic Spectral Classification Needs an Open Source Community: Open Specy to the Rescue!
Cowger, W., Steinmetz, Z., Gray, A., Munno, K., Lynch, J., Hapich, H., Primpke, S., De Frond, H., Rochman, C., & Herodotou, O. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00123 · Cited by 569
Feng, S., Chen, R., Lin, J., Pan, J., Chen, G., Li, Y., Cheng, M., Huang, Z., Chen, J., & Zeng, H. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.033 · Cited by 450
Self-citation
Metadata
- Authors
- Zhao, J., Lui, H., McLean, D. I., & Zeng, H.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2007-11
- Volume
- 61
- Issue
- 11
- Pages
- 1225-1232
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2091998550
- Cited by
- 810
- References
- 25
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.