CoChat

NASA's first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research

Open access

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index; 11 of the 31 sources its claims cite were checked for support.

Abstract

With exciting new NASA plans for a sustainable return to the moon, astronauts will once again leave Earth's protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPEs with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including circulatory and heart disease, as well as potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy-ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the "GCR Simulator" to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (approximately 65%-75%) and helium ions (approximately 10%-20%) with heavier ions (Z ≥ 3) contributing the remainder. The GCR simulator exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the 5 heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader system is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low-energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires approximately 75 minutes. To more closely simulate the low-dose rates found in space, sequential field exposures can be divided into daily fractions over 2 to 6 weeks, with individual beam fractions as low as 0.1 to 0.2 mGy. In the large beam configuration (60 × 60 cm2), 54 special housing cages can accommodate 2 to 3 mice each for an approximately 75 min duration or 15 individually housed rats. On June 15, 2018, the NSRL made a significant achievement by completing the first operational run using the new GCR simulator. This paper discusses NASA's innovative technology solution for a ground-based GCR simulator at the NSRL to accelerate our understanding and mitigation of health risks faced by astronauts. Ultimately, the GCR simulator will require validation across multiple radiogenic risks, endpoints, doses, and dose rates.

Overview

CoChat Summary

## TL;DR

NASA’s GCR Simulator at NSRL was built to reproduce a shielded deep-space galactic cosmic ray environment using fast sequential beam switching, with a 33-beam reference field normalized to 500 mGy and delivered in about 70–75 minutes. The paper reports that the system was commissioned in 2017 and first used in 2018, enabling mixed-field, chronic, and countermeasure-oriented radiobiology studies in animal and cell models.

## Key findings

  • The simulator’s reference field is based on the shielded tissue environment behind 20 g/cm2 aluminum during solar minimum, and is designed to deliver most dose from protons and helium, with heavier ions making up the remainder.
  • The full simulator uses 33 sequential beams: 4 proton energies plus degrader, 4 helium energies plus degrader, and 5 heavy ions (C, O, Si, Ti, Fe); a 500 mGy exposure requires approximately 75 minutes.
  • For the reference field, the paper reports that Z = 1 ions account for approximately 64% of dose behind 20 g/cm2, Z = 2 ions approximately 17%, and Z ≥ 3 ions approximately 7%; in free space, HZE particles contribute approximately 89% of total dose equivalent.
  • Facility tests reported smooth dose distributions in phantoms: the Digimouse organ average dose was 500.7 mGy with soft-tissue variation less than 3%, and the digirat organ average dose was 490.7 mGy with soft-tissue variation less than 5%.

## Methods

  • Design paper describing development and implementation of a ground-based GCR simulator at NASA’s Space Radiation Laboratory (NSRL), including reference-field definition, beam selection, facility modifications, animal/cell handling, and dose-rate/fractionation strategy.
  • The reference environment was modeled using the Badhwar–O’Neill GCR model, HZETRN transport code, CAD vehicle geometries, human phantoms, Digimouse/digirat voxel models, and Geant4 transport.
  • The paper compares alternative implementation strategies (external field, local tissue field, hybrid) and adopts a local tissue approach; analyses include shielding/environment calculations, LET and dose distribution comparisons, and operational testing of beam delivery, dosimetry, and phantoms.

## Limitations

  • The paper states that NSRL’s upper energy limit of 1.5 to 2.5 GeV/n is the largest constraint on implementation strategy, and that the simulator does not represent the detailed LET spectra for all shield designs or time in solar cycle.
  • It also states that some components are not explicitly simulated, including heavy target fragments from inelastic neutron interactions and π/EM cascades.
  • Evident from the text: this is primarily a capability/development paper rather than a completed outcomes study; the “first GCR simulation research studies” are described as ongoing or forthcoming, and most biological results are not reported here.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1371/journal.pbio.3000669

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig 1 Three key areas that must be developed together to ultimately provide the GCR simulator at NSRL. Development focused on establishing irradiation requirements and balancing facility capabilities and limitations, including constraints imposed by animal and cellular model systems. GCR, galactic cosmic radiation; NSRL, NASA Space Radiation Laboratory.
Fig 1 Three key areas that must be developed together to ultimately provide the GCR simulator at NSRL. Development focused on establishing irradiation requirements and balancing facility capabilities and limitations, including constraints imposed by animal and cellular model systems. GCR, galactic cosmic radiation; NSRL, NASA Space Radiation Laboratory.CC0 · PubMed Central
Fig 2 Relative contribution to fluence (squares), dose (diamonds), and dose equivalent (circles) of different elements in the free-space GCR environment during solar minimum conditions (June 1976) as described by the Badhwar–O'Neill 2010 GCR model [14] (Adapted from Durante and Cucinotta [3]). Plot data available in S1 Data. GCR, galactic cosmic radiation.
Fig 2 Relative contribution to fluence (squares), dose (diamonds), and dose equivalent (circles) of different elements in the free-space GCR environment during solar minimum conditions (June 1976) as described by the Badhwar–O'Neill 2010 GCR model [14] (Adapted from Durante and Cucinotta [3]). Plot data available in S1 Data. GCR, galactic cosmic radiation.CC0 · PubMed Central
Fig 3 GCR particle spectra at solar minimum conditions (June 1976) denoted by solid lines and solar maximum conditions (June 2001) denoted by dashed lines in (A) free space and (B) behind 20 g/cm2 of aluminum to female BFOs as described by the Badhwar–O’Neill 2010 GCR model [14], HZETRN transport code [13,16,17], and human phantoms [15,18,19]. Plot data available in S1 Data. BFO, blood-forming organ; GCR, galactic cosmic radiation; HZETRN, High Charge and Energy Transport.
Fig 3 GCR particle spectra at solar minimum conditions (June 1976) denoted by solid lines and solar maximum conditions (June 2001) denoted by dashed lines in (A) free space and (B) behind 20 g/cm2 of aluminum to female BFOs as described by the Badhwar–O’Neill 2010 GCR model [14], HZETRN transport code [13,16,17], and human phantoms [15,18,19]. Plot data available in S1 Data. BFO, blood-forming organ; GCR, galactic cosmic radiation; HZETRN, High Charge and Energy Transport.CC0 · PubMed Central
Fig 4 Vehicle shielding is combined with shielding afforded by a crew member’s body surrounding critical organs to determine the primary and secondary radiation environment at points within the crew member. (A) Human phantoms are used to calculate the body’s self-shielding of critical organs. (B) Shield thickness provided by the vehicle are depicted as green intersecting rays in a crew exploration vehicle (similar to Orion).
Fig 4 Vehicle shielding is combined with shielding afforded by a crew member’s body surrounding critical organs to determine the primary and secondary radiation environment at points within the crew member. (A) Human phantoms are used to calculate the body’s self-shielding of critical organs. (B) Shield thickness provided by the vehicle are depicted as green intersecting rays in a crew exploration vehicle (similar to Orion).CC0 · PubMed Central
Fig 5 Three basic strategies for beam selection. (A) Beam selection is representative of the external, free-space GCR spectrum and is approximated by discrete ion and energy beams delivered onto a shielding and tissue equivalent material placed within the beam line, in front of the biological target. (B) Beam selection is representative of the shielded tissue spectrum found in space (e.g., average tissue flux behind vehicle shielding) and is approximated by discrete ion and energy beams delivered directly onto the biological target. (C) Beam selection is representative of energies less than free space with thinner amounts of vehicle shielding and variable thicknesses of tissue equivalent materials to represent the differences in body self-shielding between the physical sizes of species. GCR, galactic cosmic radiation.
Fig 5 Three basic strategies for beam selection. (A) Beam selection is representative of the external, free-space GCR spectrum and is approximated by discrete ion and energy beams delivered onto a shielding and tissue equivalent material placed within the beam line, in front of the biological target. (B) Beam selection is representative of the shielded tissue spectrum found in space (e.g., average tissue flux behind vehicle shielding) and is approximated by discrete ion and energy beams delivered directly onto the biological target. (C) Beam selection is representative of energies less than free space with thinner amounts of vehicle shielding and variable thicknesses of tissue equivalent materials to represent the differences in body self-shielding between the physical sizes of species. GCR, galactic cosmic radiation.CC0 · PubMed Central
Fig 6 Reference field spectra in the female BFOs behind 20 g/cm2 of aluminum shielding during solar minimum conditions. (A) Neutron, hydrogen, and helium energy spectra. (B) The corresponding differential LET spectra with and without contributions from hydrogen and helium. Based on calculations from Slaba and colleagues, 2016 [8]. Plot data available in S1 Data. BFO, blood forming organ; LET, lineal energy transfer.
Fig 6 Reference field spectra in the female BFOs behind 20 g/cm2 of aluminum shielding during solar minimum conditions. (A) Neutron, hydrogen, and helium energy spectra. (B) The corresponding differential LET spectra with and without contributions from hydrogen and helium. Based on calculations from Slaba and colleagues, 2016 [8]. Plot data available in S1 Data. BFO, blood forming organ; LET, lineal energy transfer.CC0 · PubMed Central
Fig 7 Illustration of beam selection strategy for GCR simulator. The total LET spectrum (light blue) and the HZE spectrum (dark blue) are shown separately. The green bars are representative of the number of single-ion beam experiments performed at NSRL as a function of LET (scaled for plot clarity). The black line is representative of ICRP-60 quality factor weighting [11] to estimate biological damage (scaled for plot clarity). Plot data available in S1 Data. GCR, galactic cosmic radiation; HZE, high charge and high energy ions; ICRP, International Commission on Radiological Protection; LET, linear energy transfer; NSRL, NASA Space Radiation Laboratory.
Fig 7 Illustration of beam selection strategy for GCR simulator. The total LET spectrum (light blue) and the HZE spectrum (dark blue) are shown separately. The green bars are representative of the number of single-ion beam experiments performed at NSRL as a function of LET (scaled for plot clarity). The black line is representative of ICRP-60 quality factor weighting [11] to estimate biological damage (scaled for plot clarity). Plot data available in S1 Data. GCR, galactic cosmic radiation; HZE, high charge and high energy ions; ICRP, International Commission on Radiological Protection; LET, linear energy transfer; NSRL, NASA Space Radiation Laboratory.CC0 · PubMed Central
Fig 8 Representation of the reference field using discrete monoenergetic beams. The hydrogen and helium energy spectra are considered directly (A), whereas HZE ions are represented within the LET spectrum (B). Solid blue lines are the reference spectra from Fig 6. The bin widths for 1 GeV/n protons and helium particles are at lower fluences and not shown on the figure; however, these data are included in supplementary data file. All plot data available in S1 Data. HZE, high charge and high energy ions; LET, linear energy transfer.
Fig 8 Representation of the reference field using discrete monoenergetic beams. The hydrogen and helium energy spectra are considered directly (A), whereas HZE ions are represented within the LET spectrum (B). Solid blue lines are the reference spectra from Fig 6. The bin widths for 1 GeV/n protons and helium particles are at lower fluences and not shown on the figure; however, these data are included in supplementary data file. All plot data available in S1 Data. HZE, high charge and high energy ions; LET, linear energy transfer.CC0 · PubMed Central
Fig 9 Mouse and rat voxel models used to evaluate dose distributions in tissues from exposure to GCR simulation. Digimouse (A) has been scaled by a factor of 3.15 to obtain and estimate of a rat’s body self-shielding, referred to here as “digirat” (B). Transport of full GCR simulation field provides homogeneous dose distribution within voxel mouse model (A) and scaled rat model (B). GCR, galactic cosmic radiation.
Fig 9 Mouse and rat voxel models used to evaluate dose distributions in tissues from exposure to GCR simulation. Digimouse (A) has been scaled by a factor of 3.15 to obtain and estimate of a rat’s body self-shielding, referred to here as “digirat” (B). Transport of full GCR simulation field provides homogeneous dose distribution within voxel mouse model (A) and scaled rat model (B). GCR, galactic cosmic radiation.CC0 · PubMed Central
Fig 10 Cumulative dose as a function of LET comparing simulated environments within phantoms to the reference field and GCR simulation beam exposure. Plot data available in S1 Data. GCR, galactic cosmic radiation; LET, linear energy transfer.
Fig 10 Cumulative dose as a function of LET comparing simulated environments within phantoms to the reference field and GCR simulation beam exposure. Plot data available in S1 Data. GCR, galactic cosmic radiation; LET, linear energy transfer.CC0 · PubMed Central
Fig 11 Facility layout of NSRL at BNL. (A) Tools to reliably control system hardware settings, from ion production by the LIS through booster injection, acceleration, extraction, and delivery to the NSRL target room were developed to sequentially deliver the GCR simulator ion-energy beam combinations. (B) Position of imaging chamber behind target (top, left-hand side), cut-off chamber (top, right-hand side) near beam entrance to target room, and photo of large-area degrader (binary filter) system (bottom) in NSRL beam line to maintain control and uniformity of 60 × 60 cm2 beam. BNL, Brookhaven National Laboratory; EBIS, Electron Beam Ion Source; GCR, galactic cosmic radiation; LINAC, Linear Accelerator; LIS, laser ion source; NSRL, NASA Space Radiation Laboratory.
Fig 11 Facility layout of NSRL at BNL. (A) Tools to reliably control system hardware settings, from ion production by the LIS through booster injection, acceleration, extraction, and delivery to the NSRL target room were developed to sequentially deliver the GCR simulator ion-energy beam combinations. (B) Position of imaging chamber behind target (top, left-hand side), cut-off chamber (top, right-hand side) near beam entrance to target room, and photo of large-area degrader (binary filter) system (bottom) in NSRL beam line to maintain control and uniformity of 60 × 60 cm2 beam. BNL, Brookhaven National Laboratory; EBIS, Electron Beam Ion Source; GCR, galactic cosmic radiation; LINAC, Linear Accelerator; LIS, laser ion source; NSRL, NASA Space Radiation Laboratory.CC0 · PubMed Central
Fig 12 Housing array for mouse (A) and rat (B) irradiations in the 60 × 60 cm2 beam. Exposure boxes, made of approximately 2-mm thick polyethylene, stack together and are held in an array using a fabricated frame strucure. (C) Ventilation lids for air circulation are provided. The nonventilated sides of the lids are painted red to serve as a quick visual cue that the lids are in the correct orientation for air flow.
Fig 12 Housing array for mouse (A) and rat (B) irradiations in the 60 × 60 cm2 beam. Exposure boxes, made of approximately 2-mm thick polyethylene, stack together and are held in an array using a fabricated frame strucure. (C) Ventilation lids for air circulation are provided. The nonventilated sides of the lids are painted red to serve as a quick visual cue that the lids are in the correct orientation for air flow.CC0 · PubMed Central
Fig 13 Modified incubator for use in beamline (A) with a holder that can accommodate up to 15 T75 flasks in a 3 × 5 array or 44 T25 flasks (B).
Fig 13 Modified incubator for use in beamline (A) with a holder that can accommodate up to 15 T75 flasks in a 3 × 5 array or 44 T25 flasks (B).CC0 · PubMed Central
Fig 14 Computer screen shot measuring GCR simulator doses per particle for the 20.8 mGy cycle. GCR, galactic cosmic radiation.
Fig 14 Computer screen shot measuring GCR simulator doses per particle for the 20.8 mGy cycle. GCR, galactic cosmic radiation.CC0 · PubMed Central

Verification

Claims the paper makes

8 Valid · 8 Not valid · 13 Not checked · 114 Own results and interpretations

60 more claims

Create a free account to see all 143 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 45
  • Probably not a substantial claim. 45
  • Borderline: one of the tests for a substantial claim is unclear. 1
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 43 references

Research works printed but not linked: 2

  1. National Research Council (NRC), 2006, BEIR VII Phase 2 report
  2. International Commission on Radiological Protection (ICRP), 1991, ICRP Publication 60

Cited by

Items 201–260 of 260

Metadata

Authors
Simonsen, L. C., Slaba, T. C., Guida, P., & Rusek, A.
Affiliations
  • Langley Research Center (US)
  • Brookhaven National Laboratory (US)
Corresponding author
Simonsen, Lisa C.
Venue
PLOS Biology
Published
2020-05-19
Volume
18
Issue
5
Pages
e3000669
ISSN
  • 1544-9173 (ISSN-L)
  • 1545-7885
OpenAlex
W3026227230
Cited by
263
References
42
Citations by year
2026: 39 · 2025: 46 · 2024: 45 · 2023: 34 · 2022: 40 · 2021: 46 · 2020: 13
FWCI
22.92
Type
journal article
Language
en
Open access
Locations
  • PLoS Biology (publishedVersion, public-domain)
  • PubMed Central (publishedVersion, public-domain)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
NASA
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
  • Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
Keywords
galactic cosmic rays, space radiation, low-dose-rate exposure, heavy ions, radiation-induced cancer, central nervous system effects, immunological effects, radiation countermeasures, lunar and Mars missions, NASA Space Radiation Laboratory
MeSH terms
Animals, Cosmic Radiation, Humans, Radiobiology, Space Flight, Space Simulation, Mice, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.