NASA's first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index; 11 of the 31 sources its claims cite were checked for support.
Abstract
With exciting new NASA plans for a sustainable return to the moon, astronauts will once again leave Earth's protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPEs with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including circulatory and heart disease, as well as potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy-ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the "GCR Simulator" to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (approximately 65%-75%) and helium ions (approximately 10%-20%) with heavier ions (Z ≥ 3) contributing the remainder. The GCR simulator exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the 5 heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader system is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low-energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires approximately 75 minutes. To more closely simulate the low-dose rates found in space, sequential field exposures can be divided into daily fractions over 2 to 6 weeks, with individual beam fractions as low as 0.1 to 0.2 mGy. In the large beam configuration (60 × 60 cm2), 54 special housing cages can accommodate 2 to 3 mice each for an approximately 75 min duration or 15 individually housed rats. On June 15, 2018, the NSRL made a significant achievement by completing the first operational run using the new GCR simulator. This paper discusses NASA's innovative technology solution for a ground-based GCR simulator at the NSRL to accelerate our understanding and mitigation of health risks faced by astronauts. Ultimately, the GCR simulator will require validation across multiple radiogenic risks, endpoints, doses, and dose rates.
Overview
CoChat Summary
## TL;DR
NASA’s GCR Simulator at NSRL was built to reproduce a shielded deep-space galactic cosmic ray environment using fast sequential beam switching, with a 33-beam reference field normalized to 500 mGy and delivered in about 70–75 minutes. The paper reports that the system was commissioned in 2017 and first used in 2018, enabling mixed-field, chronic, and countermeasure-oriented radiobiology studies in animal and cell models.
## Key findings
- The simulator’s reference field is based on the shielded tissue environment behind 20 g/cm2 aluminum during solar minimum, and is designed to deliver most dose from protons and helium, with heavier ions making up the remainder.
- The full simulator uses 33 sequential beams: 4 proton energies plus degrader, 4 helium energies plus degrader, and 5 heavy ions (C, O, Si, Ti, Fe); a 500 mGy exposure requires approximately 75 minutes.
- For the reference field, the paper reports that Z = 1 ions account for approximately 64% of dose behind 20 g/cm2, Z = 2 ions approximately 17%, and Z ≥ 3 ions approximately 7%; in free space, HZE particles contribute approximately 89% of total dose equivalent.
- Facility tests reported smooth dose distributions in phantoms: the Digimouse organ average dose was 500.7 mGy with soft-tissue variation less than 3%, and the digirat organ average dose was 490.7 mGy with soft-tissue variation less than 5%.
## Methods
- Design paper describing development and implementation of a ground-based GCR simulator at NASA’s Space Radiation Laboratory (NSRL), including reference-field definition, beam selection, facility modifications, animal/cell handling, and dose-rate/fractionation strategy.
- The reference environment was modeled using the Badhwar–O’Neill GCR model, HZETRN transport code, CAD vehicle geometries, human phantoms, Digimouse/digirat voxel models, and Geant4 transport.
- The paper compares alternative implementation strategies (external field, local tissue field, hybrid) and adopts a local tissue approach; analyses include shielding/environment calculations, LET and dose distribution comparisons, and operational testing of beam delivery, dosimetry, and phantoms.
## Limitations
- The paper states that NSRL’s upper energy limit of 1.5 to 2.5 GeV/n is the largest constraint on implementation strategy, and that the simulator does not represent the detailed LET spectra for all shield designs or time in solar cycle.
- It also states that some components are not explicitly simulated, including heavy target fragments from inelastic neutron interactions and π/EM cascades.
- Evident from the text: this is primarily a capability/development paper rather than a completed outcomes study; the “first GCR simulation research studies” are described as ongoing or forthcoming, and most biological results are not reported here.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures

![Fig 2 Relative contribution to fluence (squares), dose (diamonds), and dose equivalent (circles) of different elements in the free-space GCR environment during solar minimum conditions (June 1976) as described by the Badhwar–O'Neill 2010 GCR model [14] (Adapted from Durante and Cucinotta [3]). Plot data available in S1 Data. GCR, galactic cosmic radiation.](https://figures.cochat.ai/paper-figures/3c142d47831149e99ec63c4356a32980/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-2.jpg)
![Fig 3 GCR particle spectra at solar minimum conditions (June 1976) denoted by solid lines and solar maximum conditions (June 2001) denoted by dashed lines in (A) free space and (B) behind 20 g/cm2 of aluminum to female BFOs as described by the Badhwar–O’Neill 2010 GCR model [14], HZETRN transport code [13,16,17], and human phantoms [15,18,19]. Plot data available in S1 Data. BFO, blood-forming organ; GCR, galactic cosmic radiation; HZETRN, High Charge and Energy Transport.](https://figures.cochat.ai/paper-figures/f89b8bf1a48a4a58a3289262b8e0ced5/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-3.jpg)


![Fig 6 Reference field spectra in the female BFOs behind 20 g/cm2 of aluminum shielding during solar minimum conditions. (A) Neutron, hydrogen, and helium energy spectra. (B) The corresponding differential LET spectra with and without contributions from hydrogen and helium. Based on calculations from Slaba and colleagues, 2016 [8]. Plot data available in S1 Data. BFO, blood forming organ; LET, lineal energy transfer.](https://figures.cochat.ai/paper-figures/f3261835f12d4d23a7ee76410333b85d/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-6.jpg)
![Fig 7 Illustration of beam selection strategy for GCR simulator. The total LET spectrum (light blue) and the HZE spectrum (dark blue) are shown separately. The green bars are representative of the number of single-ion beam experiments performed at NSRL as a function of LET (scaled for plot clarity). The black line is representative of ICRP-60 quality factor weighting [11] to estimate biological damage (scaled for plot clarity). Plot data available in S1 Data. GCR, galactic cosmic radiation; HZE, high charge and high energy ions; ICRP, International Commission on Radiological Protection; LET, linear energy transfer; NSRL, NASA Space Radiation Laboratory.](https://figures.cochat.ai/paper-figures/8a620274454c4517995943c613c293c2/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-7.jpg)







Verification
Claims the paper makes
8 Valid · 8 Not valid · 13 Not checked · 114 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The radiation transport code, HZETRN [13,16,17], used to calculate reference field quantities, propagates secondary neutrons and any of their reaction products with charge of Z ≤ 2.”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Methods and models > Determination of GCR reference environment
What the sources say
- Not checked — no full text of the sourcecites [13] JW Wilson, 1991
- Not checked — no full text of the sourcecites [16] TC Slaba, 2010, Faster and more accurate transport procedures for HZETRN, J. Comp. Phys source
- Partly supportedcites [17] TC Slaba, 2010, Coupled neutron transport for HZETRN, Radiat. Meas sourceExperimental — accuracy not yet measured
The Results (p. not available) describe HZETRN transporting neutrons and light ions, including protons, ²H, ³He, and ⁴He. The Conclusions (p. not available) say coupling neutron transport to low-energy light-ion transport is a first-order approximation recommended for use, not an unqualified feature of every HZETRN calculation. The paper also does not establish that *any* neutron reaction product with Z ≤ 2 is propagated. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“A number of radiobiology studies have indicated that the order of exposure to protons and heavy ions may be an important parameter for GCR simulator design due to varied responses observed for different sequences of fractionated doses [31,32].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Methods and models > Implementing the GCR simulator at the NSRL
What the sources say
- Supportedcites [31] SP Sasi, 2017, Different Sequences of Fractionated Low-Dose Proton and Single Iron-Radiation-Induced Divergent Biological Responses in the Heart, Radiation Research source
The Methods compare opposite orders of fractionated proton doses and a single iron-ion dose in mice. The Discussion (Mixed Ion Fractionated Radiation Treatment Groups; page not provided) reports cardiac dysfunction and fibrosis when iron preceded protons, but no negative heart effect over three months when protons preceded iron. The Introduction describes the experiment as emulating a possible space-like environment, supporting the hedged implication that exposure order may matter for simulator design. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [32] G Zhou, 2006, Proton-HZE-Particle sequential dual-beam exposures increase anchorage-independent growth frequencies in primary human fibroblasts, Radiation Research source
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Given the continuous low-dose rates found in space (<1 mGy/day), challenges remain in simulating the galactic cosmic ray environment in Earth-based analogs [4].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Methods and models > Implementing the GCR simulator at the NSRL
What the sources say
- Supportedcites [4] JW Norbury, 2016, Galactic cosmic ray simulation at the NASA Space Radiation Laboratory, Life Sciences in Space Research source
Section 5.1 reports space dose rates of 0.3–0.6 mGy/day and says ground-based experiments generally use much higher rates because of facility and running-time constraints. The Introduction also states that ground-based GCR simulation can only approximate the space environment in dose and dose rate. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“With these control modifications and helium gas provided as a source, ion and energy changes are achieved by a single command in less than 2 minutes [39].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Results > NSRL facility modifications Investments in advanced ion-source technology and control systems were essential to enable a mixed-field irradiation capability. GCR simulator ion beams are extracted from BNL’s Booster synchrotron and transported to the shielded target room within the NSRL facility as shown in Fig 11. Three sources can supply ions to the Booster, including the Linear Accelerator (LINAC; protons only), the Tandem Van de Graaff (ions and protons), and the EBIS (any ion except protons) [39]. The GCR simulator relies on EBIS for helium and heavy ions and either the LINAC or Tandem for protons. EBIS has 2 ports for gas sources that are manually changed to switch between ion species generated. Helium occupies one of those ports during GCR simulations. In late 2013, EBIS was equipped with a laser ion source (LIS), which has the capability to produce ions from many different solid targets as well as to rapidly switch between solid-source targets through automated controls software. Modifications to fit the LIS’s vacuum chamber with a translation table enabled the installation of the specific solid targets needed for the production of 12C, 16O, 28Si, 48Ti, and 56Fe required by the simulator. With these control modifications and helium gas provided as a source, ion and energy changes are achieved by a single command in less than 2 minutes [39]. In late 2016, a variable thickness stripping foil changer was installed at the upstream end of the D6 septum magnet to improve control of source-beam optics after Booster extraction and prior to injection into the NSRL beam line. The foil changer consists of 8 individual thicknesses of foils from 0.25 to 16 mil (6.35 × 10−4 cm to 4.064 × 10−2 cm) with the thinnest foils made of aluminum and the thicker foils (≥1 mil or ≥2.54 × 10−3 cm) made of copper which are remotely controlled in the beam line to provide a range of thicknesses from 0.25 to 63.75 mils (6.35 × 10−4 to 1.619 × 10−1 cm). This upgrade from the previous 2 foil filter system enables better control of the beam shape at the target location in switching from one ion-energy combination to another [39]. In the summer of 2021, EBIS II will be installed replacing the current EBIS and provide the capability for direct gas injection into the beam line. Initial feasibility tests have provided confidence that EBIS II will have the capability to deliver protons to the NSRL and reduce the dependence on LINAC or Tandem as sources. Given the simulator delivers approximately 70% of dose from protons, this upgrade will provide an added level of autonomy and efficiency during operations. The software controlling the order and dose of ion-energy beam combinations to the target is run locally from the NSRL dosimetry console. After ion production at the source, all hardware control settings along the beam lines, including moving species through the EBIS, the transfer line to the Booster (including the big-bend magnet), the Booster itself (injection and extraction), and the NSRL beam line (R-line), must be able to change to sequentially deliver different beams within a reasonable amount of time (Fig 11). A single software application was developed and extensively tested to reliably move from one hardware setting to another. The simulator control file contains the sequential list of ion-energy-dose combinations (Table 3) to which various elements of the accelerator and dosimetry systems must respond in a precisely choreographed sequence. A significant challenge was developing the software architecture to archive and recall the unique hardware control settings for each beam. The ion-energy beam combinations are selected and controlled by the BNL complex-wide Linux cluster while a NSRL local software program controls dose delivered using essentially a dose-based beam cut-off system. Because there are many opportunities for any part of the system to fail at any given time, a means to exit the sequence without overexposing the targets is essential. This was challenging and added much complexity to the software control system. Incremental demonstration of the modified system was successfully demonstrated in 2016 with the delivery of H, Si, and Fe ions to the NSRL target room in a single day. As described previously (see Dose-rate studies), chronic GCR simulations require the delivery of individual beam fractions as low as 0.1 to 0.2 mGy. This represented another significant challenge for operations. In 2017, a series of tests were performed to demonstrate NSRL’s capability to image the beam at such low-dose rates, to retain sufficient monitoring and control over the beam shape, and to reliably measure the low daily doses specified for each beam. The Booster is a synchrotron, so the beam is delivered in “spills,” which last a few seconds. However, the beam can be terminated at a specified dose at any time during a spill. Located behind the biological target (or behind the cage array) is a digital imaging chamber capable of detecting doses as low as 0.05 mGy per beam spill. A cut-off chamber is positioned to intercept the beam at the upstream end of the optical bench or experimental rail system (see Fig 11B), where the beam area is smaller and the dose rate is about 10 times higher. At this location, the cut-off chamber can detect and reliably measure the beam. The cut-off chamber is calibrated against an NIST–(National Institute of Standards and Technology) traceable thimble ion reference chamber placed at the downstream end of the optical bench (in front of the imaging chamber) at the target location. The thimble ion reference chamber has also been verified against scintillation counters with various ions and energies to confirm fluence-dose relationships of delivered beams. Thus, dose calibration is transferred from a sensitive reference chamber at the target location, where the dose rate is low, to a chamber that can cut the accelerator beam off, located where the beam is much more intense. These dosimetry systems were tested at the extremely low doses required for chronic simulations confirming reliability and control over beam parameters. The GCR simulator can be delivered in a 20 × 20 cm2 or in a larger 60 × 60 cm2 beam configuration. Typical dose rates of approximately 10 Gy/min and approximately 0.5 Gy/min are available for the 20 × 20 cm2 and the 60 × 60 cm2 configurations, respectively. Beam uniformity is monitored with segmented thin ion chambers and fluorescent screen techniques during beam preparation and dose delivery. The ion chamber is capable of measuring differences in intensity of 2% to 3% over the 60 × 60 cm2 area. During the 2018 GCR simulator runs, an older variable thickness degrader (binary filter) system was used to deliver the 20 lower energy proton and helium beams to the target from incident beams of 100 MeV/n. The original system was designed to be used with a beam size much smaller than 60 × 60 cm2 and was placed 8-m upstream of the target area to intercept the incident beam where its cross-sectional area was still small (Fig 11B). Because of this distance, the degraded beams arrived at the target with a nonuniform spatial distribution, peaking in the center and reduced to approximately 75% intensity at the corners. This represented a nonuniformity in overall dose of about 4% over the entire 33-beam cycle. During the first GCR simulations in the fall of 2018, animals in exposure cages were limited to the central portion of the large beam, leaving the corner cage boxes vacant, and were rotated through locations within the beam spot during fractionated runs. In 2019, a large-area degrader system was installed approximately 1-m upstream of the target location to enhance spatial uniformity across the 60 × 60 cm2 beam spot (See Fig 11B). This now allows for the full utilization of the beam area and alleviates the need to rotate animal cage positions within the beam spot. The binary filter thicknesses are the same thicknesses as the previous system ranging from 0.1, 0.2, …, 12.8 cm of polyethlylene (with a density of 0.93 g/cm3). The resolution of this system enables verification of incoming beam energies through Bragg curve/range measurements, which is especially important for the lowest energy proton and helium beams utilized in the simulation. Because of its closer proximity to the target, these energy-degraded beams do not lose their shape and maintain good uniformity in dose, intensity, and calibration quality. Prior to experimental runs, set-up and calibration files are tested several times to ensure the control systems are correctly reading files and providing required hardware settings. On a daily basis, operators confirm all ion beams are availble from the EBIS and run various ion-energy beam combinations (H20, He20, Si600, C1000, Ti1000, Fe600) to ensure the cut-off record is automatically created and that calibration and ion chambers readings are correctly recorded. These test runs help capture and track daily drifts in calibration, which are mainly caused by small drifts in beam shape and are typically within 4%. Other uncertainties, or errors, come from the beam cut-off system. The magnitude of the uncertainty depends on the dose delivered from a given ion-energy combination with larger percent errors associated with the smaller doses. Thus, this error is 0.1% to 2% for individual beams and about 0.2% for the cumulative dose delivered by the 33-beam cycle. These measures ensure the stability of the beam over long irradiation periods and over multiple days. Simulator set-up typically requires approximately 1 to 1.5 hours prior to daily experimental runs but can be much longer with unforeseen circumstances. Preparing for Simplified 5-Ion Simulator (Table 6) runs requires significantly less set-up time. Each GCR simulation run requires 21 switches of unique ion-energy beam combinations to the target room. Switch times range between approximately 2 to 4 minutes with longer switch times required for He species to wait for the EBIS to clear prior to the introduction of a new species. The additional 12 beams (lower energy H and He) are generated via the binary filter in the NSRL beam line. Approximately 70 to 75 minutes is required to deliver the doses from all 33 beams for either acute (250 to 750 mGy) or daily fractionated exposures, which may pose a challenge for certain animal or cell model systems. The simplified 5-ion GCR simulation requires approximately 20 to 25 minutes to deliver either acute or fractionated exposures. Additional software records dose over each individual GCR simulation ion as well as cumulative dose for both acute and fractionated dose-rate protocols. Each investigator is provided with a detailed record of the absorbed dose in tissue and the duration of each radiation exposure.
What the sources say
- Partly supportedcites [39] C La Tessa, 2016, Overview of the NASA Space Radiation Laboratory, Life Sci Space Res (Amst) sourceExperimental — accuracy not yet measured
Section 2.3 (p. 7) says control upgrades allow ion and energy changes by a single command in less than two minutes. Section 2.1 (p. 5) mentions two additional gas sources, but does not identify either as helium, so the helium-specific part is unsupported. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“This upgrade from the previous 2 foil filter system enables better control of the beam shape at the target location in switching from one ion-energy combination to another [39].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Results > NSRL facility modifications Investments in advanced ion-source technology and control systems were essential to enable a mixed-field irradiation capability. GCR simulator ion beams are extracted from BNL’s Booster synchrotron and transported to the shielded target room within the NSRL facility as shown in Fig 11. Three sources can supply ions to the Booster, including the Linear Accelerator (LINAC; protons only), the Tandem Van de Graaff (ions and protons), and the EBIS (any ion except protons) [39]. The GCR simulator relies on EBIS for helium and heavy ions and either the LINAC or Tandem for protons. EBIS has 2 ports for gas sources that are manually changed to switch between ion species generated. Helium occupies one of those ports during GCR simulations. In late 2013, EBIS was equipped with a laser ion source (LIS), which has the capability to produce ions from many different solid targets as well as to rapidly switch between solid-source targets through automated controls software. Modifications to fit the LIS’s vacuum chamber with a translation table enabled the installation of the specific solid targets needed for the production of 12C, 16O, 28Si, 48Ti, and 56Fe required by the simulator. With these control modifications and helium gas provided as a source, ion and energy changes are achieved by a single command in less than 2 minutes [39]. In late 2016, a variable thickness stripping foil changer was installed at the upstream end of the D6 septum magnet to improve control of source-beam optics after Booster extraction and prior to injection into the NSRL beam line. The foil changer consists of 8 individual thicknesses of foils from 0.25 to 16 mil (6.35 × 10−4 cm to 4.064 × 10−2 cm) with the thinnest foils made of aluminum and the thicker foils (≥1 mil or ≥2.54 × 10−3 cm) made of copper which are remotely controlled in the beam line to provide a range of thicknesses from 0.25 to 63.75 mils (6.35 × 10−4 to 1.619 × 10−1 cm). This upgrade from the previous 2 foil filter system enables better control of the beam shape at the target location in switching from one ion-energy combination to another [39]. In the summer of 2021, EBIS II will be installed replacing the current EBIS and provide the capability for direct gas injection into the beam line. Initial feasibility tests have provided confidence that EBIS II will have the capability to deliver protons to the NSRL and reduce the dependence on LINAC or Tandem as sources. Given the simulator delivers approximately 70% of dose from protons, this upgrade will provide an added level of autonomy and efficiency during operations. The software controlling the order and dose of ion-energy beam combinations to the target is run locally from the NSRL dosimetry console. After ion production at the source, all hardware control settings along the beam lines, including moving species through the EBIS, the transfer line to the Booster (including the big-bend magnet), the Booster itself (injection and extraction), and the NSRL beam line (R-line), must be able to change to sequentially deliver different beams within a reasonable amount of time (Fig 11). A single software application was developed and extensively tested to reliably move from one hardware setting to another. The simulator control file contains the sequential list of ion-energy-dose combinations (Table 3) to which various elements of the accelerator and dosimetry systems must respond in a precisely choreographed sequence. A significant challenge was developing the software architecture to archive and recall the unique hardware control settings for each beam. The ion-energy beam combinations are selected and controlled by the BNL complex-wide Linux cluster while a NSRL local software program controls dose delivered using essentially a dose-based beam cut-off system. Because there are many opportunities for any part of the system to fail at any given time, a means to exit the sequence without overexposing the targets is essential. This was challenging and added much complexity to the software control system. Incremental demonstration of the modified system was successfully demonstrated in 2016 with the delivery of H, Si, and Fe ions to the NSRL target room in a single day. As described previously (see Dose-rate studies), chronic GCR simulations require the delivery of individual beam fractions as low as 0.1 to 0.2 mGy. This represented another significant challenge for operations. In 2017, a series of tests were performed to demonstrate NSRL’s capability to image the beam at such low-dose rates, to retain sufficient monitoring and control over the beam shape, and to reliably measure the low daily doses specified for each beam. The Booster is a synchrotron, so the beam is delivered in “spills,” which last a few seconds. However, the beam can be terminated at a specified dose at any time during a spill. Located behind the biological target (or behind the cage array) is a digital imaging chamber capable of detecting doses as low as 0.05 mGy per beam spill. A cut-off chamber is positioned to intercept the beam at the upstream end of the optical bench or experimental rail system (see Fig 11B), where the beam area is smaller and the dose rate is about 10 times higher. At this location, the cut-off chamber can detect and reliably measure the beam. The cut-off chamber is calibrated against an NIST–(National Institute of Standards and Technology) traceable thimble ion reference chamber placed at the downstream end of the optical bench (in front of the imaging chamber) at the target location. The thimble ion reference chamber has also been verified against scintillation counters with various ions and energies to confirm fluence-dose relationships of delivered beams. Thus, dose calibration is transferred from a sensitive reference chamber at the target location, where the dose rate is low, to a chamber that can cut the accelerator beam off, located where the beam is much more intense. These dosimetry systems were tested at the extremely low doses required for chronic simulations confirming reliability and control over beam parameters. The GCR simulator can be delivered in a 20 × 20 cm2 or in a larger 60 × 60 cm2 beam configuration. Typical dose rates of approximately 10 Gy/min and approximately 0.5 Gy/min are available for the 20 × 20 cm2 and the 60 × 60 cm2 configurations, respectively. Beam uniformity is monitored with segmented thin ion chambers and fluorescent screen techniques during beam preparation and dose delivery. The ion chamber is capable of measuring differences in intensity of 2% to 3% over the 60 × 60 cm2 area. During the 2018 GCR simulator runs, an older variable thickness degrader (binary filter) system was used to deliver the 20 lower energy proton and helium beams to the target from incident beams of 100 MeV/n. The original system was designed to be used with a beam size much smaller than 60 × 60 cm2 and was placed 8-m upstream of the target area to intercept the incident beam where its cross-sectional area was still small (Fig 11B). Because of this distance, the degraded beams arrived at the target with a nonuniform spatial distribution, peaking in the center and reduced to approximately 75% intensity at the corners. This represented a nonuniformity in overall dose of about 4% over the entire 33-beam cycle. During the first GCR simulations in the fall of 2018, animals in exposure cages were limited to the central portion of the large beam, leaving the corner cage boxes vacant, and were rotated through locations within the beam spot during fractionated runs. In 2019, a large-area degrader system was installed approximately 1-m upstream of the target location to enhance spatial uniformity across the 60 × 60 cm2 beam spot (See Fig 11B). This now allows for the full utilization of the beam area and alleviates the need to rotate animal cage positions within the beam spot. The binary filter thicknesses are the same thicknesses as the previous system ranging from 0.1, 0.2, …, 12.8 cm of polyethlylene (with a density of 0.93 g/cm3). The resolution of this system enables verification of incoming beam energies through Bragg curve/range measurements, which is especially important for the lowest energy proton and helium beams utilized in the simulation. Because of its closer proximity to the target, these energy-degraded beams do not lose their shape and maintain good uniformity in dose, intensity, and calibration quality. Prior to experimental runs, set-up and calibration files are tested several times to ensure the control systems are correctly reading files and providing required hardware settings. On a daily basis, operators confirm all ion beams are availble from the EBIS and run various ion-energy beam combinations (H20, He20, Si600, C1000, Ti1000, Fe600) to ensure the cut-off record is automatically created and that calibration and ion chambers readings are correctly recorded. These test runs help capture and track daily drifts in calibration, which are mainly caused by small drifts in beam shape and are typically within 4%. Other uncertainties, or errors, come from the beam cut-off system. The magnitude of the uncertainty depends on the dose delivered from a given ion-energy combination with larger percent errors associated with the smaller doses. Thus, this error is 0.1% to 2% for individual beams and about 0.2% for the cumulative dose delivered by the 33-beam cycle. These measures ensure the stability of the beam over long irradiation periods and over multiple days. Simulator set-up typically requires approximately 1 to 1.5 hours prior to daily experimental runs but can be much longer with unforeseen circumstances. Preparing for Simplified 5-Ion Simulator (Table 6) runs requires significantly less set-up time. Each GCR simulation run requires 21 switches of unique ion-energy beam combinations to the target room. Switch times range between approximately 2 to 4 minutes with longer switch times required for He species to wait for the EBIS to clear prior to the introduction of a new species. The additional 12 beams (lower energy H and He) are generated via the binary filter in the NSRL beam line. Approximately 70 to 75 minutes is required to deliver the doses from all 33 beams for either acute (250 to 750 mGy) or daily fractionated exposures, which may pose a challenge for certain animal or cell model systems. The simplified 5-ion GCR simulation requires approximately 20 to 25 minutes to deliver either acute or fractionated exposures. Additional software records dose over each individual GCR simulation ion as well as cumulative dose for both acute and fractionated dose-rate protocols. Each investigator is provided with a detailed record of the absorbed dose in tissue and the duration of each radiation exposure.
What the sources say
- Could not verifycites [39] C La Tessa, 2016, Overview of the NASA Space Radiation Laboratory, Life Sci Space Res (Amst) sourceExperimental — accuracy not yet measured
Section 2.2 (p. 7) describes beam shaping with magnets, collimators and shielding blocks; Section 3.6 (p. 16) describes changing beam energy with a range shifter. Searches for a stripping-foil changer, a previous two-foil system and the claimed improvement in beam-shape control found no passage addressing that upgrade. (LLM, conf=0.74)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
60 more claims
Create a free account to see all 143 claims and every source verdict.
- It may state two separate claims as one. 45
- Probably not a substantial claim. 45
- Borderline: one of the tests for a substantial claim is unclear. 1
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“considering that the relative contribution to the GCR total dose is about 40% for protons, 20% for He-ions, 10% for Fe-ions, and 30% for ions between Helium and Iron [38]”
From Radiobiological damage by space radiation: extension of the BIANCA model to heavy ions up to iron, and pilot application to cosmic ray exposure (2022) · cites this paper as [38]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“HZE ions, although a small fraction of the overall GCR spectrum compared to protons, are more biologically damaging. They differ from terrestrial forms of radiation, such as X-rays and gamma-rays, in both the amount (dose) of exposure as well as in the patterns of DNA double-strand breaks and oxidative damage that they impart as they traverse through tissue and cells (Fig. 3)5.”
From Red risks for a journey to the red planet: The highest priority human health risks for a mission to Mars (2020) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Estimates of exposure for a round-trip, Mars planetary expedition are in the range of 870-1200 mSv (Simonsen et al., 2020).”
From Breaking the limit: Biological countermeasures for space radiation exposure to enable long-duration spaceflight (2022) · cites this paper as Simonsen et al., 2020
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Rather than studying single ions it is now possible to simulate the full GCR spectrum on Earth both in USA23 and European24 accelerators and this will pave the way to realistic RBE estimation of the full GCR.”
From Towards sustainable human space exploration—priorities for radiation research to quantify and mitigate radiation risks (2023) · cites this paper as [23]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Outside of the Earth’s protective magnetosphere, crews are exposed to pervasive, low dose-rate galactic cosmic rays (GCR) and to intermittent solar particle events (SPEs)5.”
From Red risks for a journey to the red planet: The highest priority human health risks for a mission to Mars (2020) · cites this paper as [5]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 2×
“The voxel models have been coupled to the Monte Carlo transport code, Geant4 [33], for radiation transport of single-particle beams and the complete 33 ion beam GCR simulator.”
MethodHealth Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Recommendations of the International Commission on Radiological Protection
(1959) · Health Physics · doi:10.1097/00004032-195901000-00001 · Cited by 1,703
Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
(2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 904
Measurements of energetic particle radiation in transit to Mars on the Mars Science Laboratory
Zeitlin, C., Hassler, D. M., Cucinotta, F. A., Ehresmann, B., Wimmer-Schweingruber, R. F., Brinza, D. E., Kang, S., Weigle, G., Böttcher, S., Böhm, E., et al. (2013) · Science · doi:10.1126/science.1235989 · Cited by 641
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528 · cited 4×
“Physical shielding strategies designed to significantly reduce the health risks from GCR become prohibitively costly because of the high charge (Z) and energy (E) of the primary constituent particles, referred to as high charge and high energy (HZE) particles, and from the production of secondary protons, neutrons, an…”
BackgroundMethodInfluential(1991) · NASA STI Repository (National Aeronautics and Space Administration) · Cited by 384
Self-citationSpace radiation risks to the central nervous system
Cucinotta, F. A., Alp, M., Sulzman, F. M., & Wang, M. (2014) · Life Sciences in Space Research · doi:10.1016/j.lssr.2014.06.003 · Cited by 262 · cited 1×
“Computational analyses of accelerator GCR simulations have shown that a large percentage of cells will be hit with 2 or more particles in simulated chronic exposures of a week or less and recommend exposures of several weeks with times approaching 30 days or longer to avoid any high dose-rate artifacts [36,37].”
BackgroundKramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239 · cited 2×
“[13,16,17], vehicle computer-aided design (CAD) geometries, and human phantoms [15,18,19].”
BackgroundMethodSpace Radiation Cancer Risk Projections and Uncertainties – 2012
Cucinotta, F. A., Y.Kim, M.-H., & Chappell, L. J. (2013) · NASA · doi:10.13140/rg.2.1.1413.3528 · Cited by 218
Research works printed but not linked: 2
- National Research Council (NRC), 2006, BEIR VII Phase 2 report
- International Commission on Radiological Protection (ICRP), 1991, ICRP Publication 60
Cited by
Items 101–200 of 260
Corti, G., Kim, J., Enguita, F. J., Guarnieri, J. W., Grossman, L. I., Costes, S. V., Fuentealba, M., Scott, R. T., Magrini, A., Sanders, L., et al. (2024) · Communications Biology · doi:10.1038/s42003-024-06944-6 · Cited by 9
Hellweg, C. E., Arena, C., Baatout, S., Baselet, B., Beblo‐Vranesevic, K., Caplin, N., Coos, R., Pieve, F. D., Micco, V. D., Foray, N., et al. (2023) · Springer eBooks · doi:10.1007/978-3-031-18810-7_10 · Cited by 18
Very-High-Energy Heavy Ion Beam Dosimetry Using Solid State Detectors for Electronics Testing
Waets, A., Biłko, K., Coronetti, A., Emriskova, N., Barbero, M. S., Alía, R. G., Durante, M., Schuy, C., Wagner, T., Esposito, L. S., et al. (2024) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2024.3350667 · Cited by 9
“This approach is used in particle therapy centers [13] and in dedicated facilities such as the NASA Space Radiation Laboratory [14], [15] in the USA.”
MethodCombined Environment Simulator for Low-Dose-Rate Radiation and Partial Gravity of Moon and Mars
Takahashi, A., Yamanouchi, S., Takeuchi, K., Takahashi, S., Tashiro, M., Hidema, J., Higashitani, A., Adachi, T., Zhang, S., Guirguis, F. N. L., et al. (2020) · Life · doi:10.3390/life10110274 · Cited by 10
“In the NASA Space R diatio Labor tory (NS L) at Brookh ven National Lab ratory (BNL), SPE nd GCR simulated beam an be used by r pid switching technology of ion species and i n e ergies [3].”
MethodInfluentialLaiakis, E. C., Pinheiro, M., Nguyen, T., Nguyen, H., Beheshti, A., Dutta, S. M., Russell, W. K., Emmett, M. R., & Britten, R. A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.971282 · Cited by 10
Simmons, P., Trujillo, M., McElroy, T., Binz, R. L., Pathak, R., & Allen, A. R. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.908632 · Cited by 9
“However, the deep space radiation environment consists of a much more complex variety of species over a broad range of energies (Simonsen et al., 2020), and a clearer understanding of the consequences of GCR irradiation on CNS functionality is needed.”
BackgroundEffects of Simulated 5-Ion Galactic Cosmic Radiation on Function and Structure of the Mouse Heart
Nemec-Bakk, A. S., Sridharan, V., Desai, P., Landes, R. D., Hart, B. P., Allen, A. R., & Boerma, M. (2023) · Life · doi:10.3390/life13030795 · Cited by 11
“This study used NSRL’s 5-ion simulated galactic cosmic ray (GCRsim) beam [12] to evaluate the cardiac structure and function in murine models.”
MethodA new type of ground-based simulator of radiation field inside a spacecraft in deep space
Gordeev, I. S., & Тимошенко, Г. Н. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2021.05.002 · Cited by 31
Plante, I., Daniels, V., Young, M., Gaza, R., Wu, H., & Reichard, J. F. (2025) · npj Microgravity · doi:10.1038/s41526-025-00469-w · Cited by 7
Wang, H., Dong, J., Li, G., Tan, Y., Hai, Z., Zhang, L., Wang, Y., Hu, Z., Cao, X., Shi, F., et al. (2021) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2021.03.133 · Cited by 7
Suman, S., Kumar, S., Kallakury, B., Moon, B., Angdisen, J. J., Datta, K., & Fornace, A. J. (2022) · Radiation and Environmental Biophysics · doi:10.1007/s00411-022-00997-z · Cited by 9
Radioprotective effect of the anti-diabetic drug metformin
Siteni, S., Barron, S., Luitel, K., & Shay, J. W. (2024) · PLoS ONE · doi:10.1371/journal.pone.0307598 · Cited by 11
Rahmanian, S., Slaba, T. C., George, S., Braby, L. A., Bhattacharya, S., Straume, T., & Maria, S. R. S. (2024) · Life Sciences in Space Research · doi:10.1016/j.lssr.2024.10.006 · Cited by 10
Self-citationKumar, K., Angdisen, J. J., Ma, J., Datta, K., Fornace, A. J., & Suman, S. (2024) · Cancers · doi:10.3390/cancers16233954 · Cited by 7
Machine Learning Models to Predict Cognitive Impairment of Rodents Subjected to Space Radiation
Matar, M., Gökoğlu, S. A., Prelich, M. T., Gallo, C. A., Iqbal, A. K., Britten, R. A., Prabhu, R. K., & Myers, J. G. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.713131 · Cited by 9
“In these animal model studies, cancer (Cucinotta et al., 2011; Sridharan et al., 2015; Blattnig and Chappell, 2016), cardiovascular issues (Baker et al., 2011; Boerma, 2015), and central nervous system (CNS) damage (Rabin et al., 2005; Cucinotta et al., 2014; Parihar et al., 2015; Cekanaviciute et…”
BackgroundThymus ad astra, or spaceflight-induced thymic involution
Muramatsu, W., Maryanovich, M., Akiyama, T., & Karagiannis, G. S. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1534444 · Cited by 6
Watkins, P., Knoerzer, K., Ferlazzo, M. L., Banati, R. B., Adorno, P., Stockham, K., & Stobaus, T. (2023) · Advances in Astronautics Science and Technology · doi:10.1007/s42423-023-00140-0 · Cited by 8
He, M., Dong, X., Xiang, M., Ma, Y., Huang, M., Zhang, S., Yu, Q., Cao, S., Lu, Z., Li, Y., et al. (2024) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2024.165288 · Cited by 6
Mehner, C., Krishnan, S., Chou, J., Freeman, M. L., Freeman, W. D., Patel, T. C., & Turnbull, M. T. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2021.01.001 · Cited by 7
Nano-scale simulation of neuronal damage by galactic cosmic rays
Peter, J. S., Schuemann, J., Held, K. D., & McNamara, A. L. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac95f4 · Cited by 6
“While SPEs consist mainly of 10 2 MeV protons, the GCR fi eld contains signi fi cant dose contributions from high linear energy transfer ( LET ) ions ranging from hydrogen ( Z = 1 ) to nickel ( Z = 28 ) on the periodic table and energies ranging from 10 – 10 4 MeV n − 1 ( King 1974, Townsend et al 2003, Durante…”
InfluentialKumar, K., Moon, B., Datta, K., Fornace, A. J., & Suman, S. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.09.006 · Cited by 10
Alwood, J. S., Mulavara, A. P., Iyer, J. S., Mhatre, S. D., Rosi, S., Shelhamer, M., Davis, C. M., Jones, C. W., Mao, X. W., Desai, R. I., et al. (2023) · Life · doi:10.3390/life13091852 · Cited by 10
“To promote the utility of translational models, NASA consistently updates the exposure levels in rodents as they relate to humans; for example, NASA recently adjusted their integrated research platforms involving animal exposures to expected levels of spaceflight radiation related to dose and duration [8].”
MethodAndrade, M. R., Azeez, T. A., Montgomery, M. M., Caldwell, J. T., Park, H., Kwok, A. T., Borg, A. M., Narayanan, S. A., Willey, J. S., Delp, M. D., et al. (2023) · The FASEB Journal · doi:10.1096/fj.202300506rr · Cited by 10
“44 47 The development of the new GCR simulator at the NASA Space Radiation Laboratory (NSRL) was found to better simulate the HZE radiation exposure of deep space travel encountered by astronauts inside the exploration vehicle in space.”
BackgroundMethodKlomchitcharoen, S., Wechakarn, P., Tangwattanasirikun, T., Smerwong, N., Netrapathompornkij, P., Chatmeeboon, T., Nangsue, N., Thitasirivit, V., Kaweewongsunthorn, K., Piyanopharoj, S., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e27406 · Cited by 7
“Experiments on Earth are limited to only simulating a few conditions in the laboratory [14,15].”
BackgroundAdvances in space food processing: From farm to outer space
Singh, S., Negi, T., Sagar, N. A., Kumar, Y., Kaur, S., Thakur, R., Verma, K., Sirohi, R., & Tarafdar, A. (2024) · Food Bioscience · doi:10.1016/j.fbio.2024.104893 · Cited by 7
Failla Memorial Lecture: The Many Facets of Heavy-Ion Science
Durante, M. (2021) · Radiation Research · doi:10.1667/rade-21-00029.1 · Cited by 6
Poignant, F., Plante, I., Crespo, L. G., & Slaba, T. C. (2022) · Life · doi:10.3390/life12030358 · Cited by 7
“Galactic cosmic rays are composed of approximately 87% protons, 12% helium nuclei, and 1% high-charge and energy (HZE) ions [1].”
BackgroundMethodSelf-citationRamos, R. L., Bernardini, E., Carante, M. P., FERRARI, A., SALA, P. R., Vercesi, V. I., & Ballarini, F. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad7ff6 · Cited by 5
“Lower doses may be involved for lunar missions: for instance, the doses for lunar operations of 1 year at solar minimum have been estimated to be in the range 0.10–0.12 Gy , corresponding to 0.18–0.22 Gy-Eq Gy-Eq or 0.3–0.4 Sv [3].”
InfluentialPharmacological Innovations in Space: Challenges and Future Perspectives
Aksoyalp, Z. Ş., Temel, A., & Karpuz, M. (2024) · Pharmaceutical Research · doi:10.1007/s11095-024-03788-x · Cited by 9
Mao, X. W., Stanbouly, S., Jones, T., et al. (2021) · Life · doi:10.3390/life11080849 · Cited by 5
“Recognizing the importance of the health and performance of astronauts both during and post-flight, we believe that understanding the impact of space radiation on the retina and optic nerve head (ONH) is crucial in assessing the risk to astronauts during long-duration missions, especially for future deep-space mission…”
BackgroundBennett, P. V., Johnson, A. M., Ackerman, S. E., Chaudhary, P., Keszenman, D. J., & Wilson, P. F. (2021) · Radiation Research · doi:10.1667/rade-21-00138.1 · Cited by 5
“human cells grown in more complex three-dimensional organoid cultures and ‘‘humanized’’ mouse models that more directly assess mission-relevant carcinogenesis endpoints (69), especially for ion species with intermediate LET values of 10–100 keV/lm and LDR/fractionated mixed-field exposures for which data is scarce (70…”
BackgroundWeighing the impact of microgravity on vestibular and visual functions
Dontre, A. J. (2023) · Life Sciences in Space Research · doi:10.1016/j.lssr.2023.12.003 · Cited by 9
Australia’s External Ion Microbeam Irradiation Facility For Space Radiation Effects Testing
Peracchi, S., Pastuović, Ž., Drury, R., et al. (2022) · European Conference on Radiation and Its Effects on Components and Systems · doi:10.1109/radecs55911.2022.10412528 · Cited by 5
Simulated galactic cosmic radiation-induced cancer progression in mice
Luitel, K., Siteni, S., Barron, S., & Shay, J. W. (2024) · Life Sciences in Space Research · doi:10.1016/j.lssr.2024.01.008 · Cited by 10
“With the possibility of higher exposure of GCRsim we also exposed the K-ras LA1 mice with either acute or chronic GCRsim at a dose of 75 cGy (Simonsen et al., 2020; Nelson, 2016).”
InfluentialSlaba, T. C., Poignant, F., & Rahmanian, S. (2025) · Radiation Research · doi:10.1667/rade-25-00021.1 · Cited by 5
Self-citationPeracchi, S., James, B., Psoroulas, S., Großmann, M., Meer, D., Bolst, D., Pastuović, Ž., Vohradsky, J., Guatelli, S., Prokopovich, D. A., et al. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.01.041 · Cited by 5
Ramos, R. L., Embriaco, A., Carante, M. P., FERRARI, A., SALA, P. R., Vercesi, V. I., & Ballarini, A. F. (2022) · EPJ Web of Conferences · doi:10.1051/epjconf/202226103001 · Cited by 6
DiCarlo, A. L., Carnell, L. S., Rios, C. I., & Prasanna, P. G. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.06.004 · Cited by 5
“Characterization and mitigation of these risks require a significant reduction in the large biological uncertainties of chronic (low-dose rate) high charge and energy (HZE) exposures and validation of medical countermeasures (MCMs) in a relevant space environment (Simonsen et al., 2020).”
BackgroundKim, Y. B., Lim, I. J., Lim, H., Joo, Y., Park, J., Hossain, M. M., Cho, H., You, N., Ahn, S., Lee, H., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202510716 · Cited by 8
Borg, A. M., & Baker, J. E. (2021) · Synthetic Biology · doi:10.1093/synbio/ysab023 · Cited by 6
“On the shortest possible return mission to Mars, staying 30 days on the surface, a cosmonaut would absorb more than 500 mGy equivalent over the 650 day mission, empirically suggested as the dose threshold to induce cataracts requiring surgery in Japanese atomic bomb survivors (8, 25).”
BackgroundDiaz, J., Kuhlman, B. M., Edenhoffer, N. P., Evans, A. C., Martin, K. A., Guida, P. M., Rusek, A., Atala, A., Coleman, M. A., Wilson, P. F., et al. (2023) · Frontiers in Astronomy and Space Sciences · doi:10.3389/fspas.2023.1117811 · Cited by 6
“(Simonsen et al., 2020) with delivered tissue doses within 6% of the prescribed doses.”
BackgroundMethodSelf-citationVarma, C., Schroeder, M. K., Price, B. R., Khan, K., da Costa, E. C., Hochman‐Mendez, C., Caldarone, B. J., & Lemere, C. A. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25168948 · Cited by 6
“To better understand the potential risks astronauts will face on their journey through deep space to destinations like Mars, and perhaps one day, beyond, we sought to investigate changes in behavior, biochemistry, and pathology using doses of space radiation relevant to a round trip to Mars [7].”
BackgroundDeep Learning the Forecast of Galactic Cosmic-Ray Spectra
Du, Y.-L., Song, X., & Luo, X. (2025) · The Astrophysical Journal Letters · doi:10.3847/2041-8213/ada427 · Cited by 7
Tan, J., Zhou, Z., Zheng, H., Li, Y., Wang, H., Yang, Q., Tian, H., Chen, H., Xie, J., Li, Z., et al. (2025) · Radiation and Environmental Biophysics · doi:10.1007/s00411-025-01115-5 · Cited by 5
Beyond Low Earth Orbit: Biological Research, Artificial Intelligence, and Self-Driving LabsPreprint
Sanders, L. M., Yang, J. H., Scott, R. T., Qutub, A., Martín, H. G., Berrios, D., Hastings, J. J. A., Rask, J., Mackintosh, G., Hoarfrost, A. L., et al. (2021) · arXiv.org · doi:10.48550/arxiv.2112.12582 · Cited by 3
Hammond, T. G., Panikkanvalappil, S. R., Allen, P., Gaikani, H. K., Nislow, C., Giaever, G. N., Zhang, Y., Levine, H. G., Gaza, R., Dimapilis, D. I., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-05419-w · Cited by 5
“NASA’s ground-based Galactic Cosmic Ray Simulator at the NASA Space Radiation Lab 55 will be critical to understand the biology of galactic cosmic radiation but is beyond the scope and resources of the current study.”
Estrella, L. D., Sveeggen, T. M., de la Guardia, G., Cacho, J., Stauch, K. L., & Bagher, P. (2025) · npj Microgravity · doi:10.1038/s41526-025-00540-6 · Cited by 3
Nuclear data for space exploration
Smith, M. S., Vogt, R., & LaBel, K. A. (2023) · Frontiers in Astronomy and Space Sciences · doi:10.3389/fspas.2023.1228901 · Cited by 5
Beyond Earth's shield: The surprising way antioxidants could pave the road to Mars
Skirzewski, M., & Skirzewski, A. (2024) · Journal of Neurochemistry · doi:10.1111/jnc.16233 · Cited by 3
“[Correction added on 17 January 2025 after first online publication: The Special Issue title has been corrected.]. different ion species and various energy levels of hydrogen and helium (Simonsen et al., 2020).”
Pérez‐Díaz, S., Baselet, B., Lovrić, A., Lundberg, T. R., Neefs, M., Daenen, L., Rullman, E., & Fernandez‐Gonzalo, R. (2025) · The Journal of Physiology · doi:10.1113/jp288987 · Cited by 5
“These include ground-based radiobiology facilities (Simonsen et al., 2020), long-term bed rest studies in humans (Fernandez-Gonzalo et al., 2020) and hindlimb unloading (HLU) protocols in rodents (Hawliczek et al., 2022).”
Kumar, S., Kumar, K., Angdisen, J. J., Suman, S., Kallakury, B., & Fornace, A. J. (2025) · Cells · doi:10.3390/cells14221767 · Cited by 4
“Long-duration space missions beyond low Earth orbit, such as those to Mars, expose astronauts to galactic cosmic radiation (GCR), a complex, mixed field of high-charge, high-energy (HZE) ions spanning a range of low-and high-linear energy transfer (LET) particles [1–3].”
Examining the Effects of 4He Exposure on the Gut-Brain Axis
Jones, C. B., Peiffer, L. B., Davis, C. M., & Sfanos, K. S. (2021) · Radiation Research · doi:10.1667/rade-20-00285.1 · Cited by 7
Heavy-Ion-Induced Lung Tumors: Dose- & LET-Dependence
Chang, P. Y., Bakke, J. P., Rosen, C. J., Bjornstad, K. A., Mao, J., & Blakely, E. A. (2022) · Life · doi:10.3390/life12060907 · Cited by 3
“Animals were irradiated locally at SRI International and transported to the animal Facility at LBNL for the 16-month health monitoring.”
BackgroundMethodInfluentialPfuhl, T., Weber, U. A., Horst, F., Durante, M., & Schuy, C. (2023) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2023.10.002 · Cited by 3
Effect of Simulated Cosmic Radiation on Cytomegalovirus Reactivation and Lytic Replication
Mehta, S. K., Diak, D. M., Bustos-Lopez, S., Nelman-Gonzalez, M. A., Chen, X., Plante, I., Stray, S. J., Tandon, R., & Crucian, B. E. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms251910337 · Cited by 5
“NSRL has a simulated full GCRsim field, which consists of 33 different ion beams, and a simplified GCRsim, composed of six ion beams (five different ions with protons at two different energies), with protons constituting most of the exposure and delivered first and last in the sequence [18].”
BackgroundNemec-Bakk, A. S., Sridharan, V., Willey, J. S., Koturbash, I., Williams, D. K., Chesal, M., Patel, C. M., Borg, A. M., Reno, K., Gifford, G., et al. (2024) · Life Sciences in Space Research · doi:10.1016/j.lssr.2024.12.001 · Cited by 6
Kondrashev, S., Beebe, E. N., Kanesue, T., et al. (2021) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2021.165563 · Cited by 3
Hertel, N. E., Biegalski, S. R., Nelson, V. I., Nelson, W. A., Mukhopadhyay, S., Su, Z., Chan, A. M., Kesarwala, A. H., & Dynan, W. S. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.10.002 · Cited by 3
Santosh, K. C., & Abolfath, R. (2022) · Research Square · doi:10.21203/rs.3.rs-1666450/v1 · Cited by 4
Paar, V., Jiang, S., Enriquez, A., Kim, J., Brunetta, H. S., Muratani, M., Kubik, A. J., Allen, N. G., Blaber, E. A., Overbey, E. G., et al. (2023) · Research Square · doi:10.21203/rs.3.rs-2351744/v1 · Cited by 3
Spaceborne and spaceborn: Physiological aspects of pregnancy and birth during interplanetary flight
Holden, A. V. (2025) · Experimental Physiology · doi:10.1113/ep092290 · Cited by 5
Ryzhkov, N. V., Janssen, P., & Braun, A. (2025) · Astrobiology · doi:10.1177/15311074251365212 · Cited by 2
“…exposure (numerated 1 – 2) alternating with 10-minute “ dark “ periods) exposure to a 60Co gamma source, both in the gamma irradiation beam and shielded from it. with adjusted ToF but a shorter planetary stay amount to similar estimated mission values (Simonsen et al., 2020; Zeitlin et al., 2013).”
Gulacsi, E., Sabou, M., & Olsen, T. (2025) · International Journal of Radiation Biology · doi:10.1080/09553002.2025.2550438 · Cited by 2
“…research period, NASA carried out radiation experiments (Cohen 2004; Rojdev et al. 2009; Lowenstein et al. 2011; Miller et al. 2014; Norman et al. 2017; Simonsen et al. 2020; Huff et al. 2023; AAAS 2023) to see what materials could be used to reduce Galactic Cosmic Rays (GCRs) and solar radiation.”
Yang, R., Li, Z., Qin, Y., Cheng, Z. J., Zhao, Y., Chen, Y., Zhang, B., Benjakul, S., & Han, T. (2025) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2025.105342 · Cited by 2
A biological and ethical assessment of whether humans could or should reproduce in space
Cole, V. M., Savulescu, J., Illanes, S. E., Bátiz, F., Benny, P.-B. A. T., Huang, Z., Carter, S. W. D., Choolani, M. A., & Kemp, M. W. (2025) · npj Microgravity · doi:10.1038/s41526-025-00535-3 · Cited by 3
“To this end, innovations such as the NASA ground-based Galactic Cosmic Ray Simulator 1 , and studies investigating combined effects of key exposures (i.e. radiation, microgravity), such as that by Todd and colleagues, are of particular importance 2 .”
Utilizing the Life Span Study data in NASA astronaut cancer risk assessment
Stegeman, L., Slaba, T. C., Huff, J. L., Semones, E., Zawaski, J. A., & Saha, J. (2025) · Carcinogenesis · doi:10.1093/carcin/bgaf076 · Cited by 3
Self-citationHealth impacts of radiation in space and countermeasures
Tasoula, A., Poignant, F., Guarnieri, J. W., Schwertz, H., & Nelson, G. A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-32904-3.00034-0 · Cited by 8
Pettinau, F., & Orrù, A. (2026) · Applied Sciences · doi:10.3390/app16041860 · Cited by 3
Blum, R. C., Omrani, D., Kunitskaya, A., Snyder, J., Bui, C., Williams, P. M., Loftus, D. J., & Rothschild, L. J. (2026) · Frontiers in Space Technologies · doi:10.3389/frspt.2025.1692554 · Cited by 2
“The radiation dose equivalent is expected to increase from 50 to 100 mSv during a 6-month ISS mission to 300–400 mSv during 1-year sustained lunar operations, 500–600 mSv in a deep-space habitat for 1 year, and 870–1,200 mSv during a 650–920-day Mars mission (Simonsen et al., 2020).”
Li, S., Zhao, C., Ren, W., Zhang, Z., Wang, W., Zhang, Q., Ma, M., Zhao, G., Chen, F., (281351), H. L., et al. (2026) · The Innovation Life · doi:10.59717/j.xinn-life.2026.100208 · Cited by 4
Reference Radiation Field for GCR Chronic Exposure Simulation
Тимошенко, Г. Н., & Gordeev, I. S. (2021) · Physics of Particles and Nuclei Letters · doi:10.1134/s1547477121070128 · Cited by 1
Effects of neutron radiation as cosmic radiation on food resources
Hatsuda, M., Kawasaki, H., Yamakura, F., et al. (2023) · Journal of Neutron Research · doi:10.3233/jnr-230001 · Cited by 2
POLATOĞLU, A., & Gül, E. (2024) · Journal of Atmospheric and Solar-Terrestrial Physics · doi:10.1016/j.jastp.2024.106360 · Cited by 4
Raber, J., Chaudhari, M., la Torre, A. D., Holden, S. J., Kessler, K., Glaeser, B., Lenarczyk, M., Leonard, S. W., Borg, A. M., Kwok, A. T., et al. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1486767 · Cited by 3
Waets, A., Alía, R. G., Biłko, K., Emriskova, N., Esposito, L. S., Schuy, C., Wagner, T., Nieminen, P. J., & Schneider, U. (2024) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2024.3492039 · Cited by 3
“This is an appropriate choice given the important contribution Fe ions have to the dose in the free space GCR environment [25].”
Sedrati, R., & Bouchachi, D. (2025) · New Journal of Physics · doi:10.1088/1367-2630/ade46d · Cited by 2
Design of New Shielding Materials for Space Reactor Shielding Structure Optimization
Han, Y., Qinjian, C., Chi, X., et al. (2025) · IEEE Access · doi:10.1109/access.2025.3610902 · Cited by 2
“Compared with traditional energy power systems, Space Nuclear Reactor Power Systems (SNRPSs) have significant advantages in energy density and endurance, and can provide continuous and stable power support for deep space exploration missions [6], [7].”
Kotzé, P. B. (2021) · Solar Physics · doi:10.1007/s11207-021-01925-y · Cited by 2
“Galactic cosmic rays (GCRs) consist predominantly of energetic electrons, protons, and nuclei of elements up to uranium, most of which originate in the Milky Way as well as other galaxies (Simonsen et al., 2020).”
BackgroundMathematical properties of Hand Incremental Effect Additivity and other synergy theories
Hanin, L. G., Xie, L., & Sachs, R. K. (2023) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.9387 · Cited by 2
“Terrestrial linear accelerator (LINAC) and other experiments simulating the action of GCR use compositions of far fewer radiations; even so, some employ 33 different beams [12].”
BackgroundPariset, E., Plante, I., Ponomarev, A. L., Viger, L., Evain, T., Blattnig, S. R., & Costes, S. V. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.11.30.403717 · Cited by 2
Nuclear Data for High Energy Ion Interactions and Secondary Particle Production
Smith, M. S., Vogt, R., & LaBel, K. A. (2022) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1883853 · Cited by 3
Christofidou‐Solomidou, M., Sielecki, T. M., & Chatterjee, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-816196-8.00024-2 · Cited by 2
Computer modeling of a new type galactic cosmic rays simulator
Gordeev, I. S., & Bugay, A. N. (2024) · Computer Physics Communications · doi:10.1016/j.cpc.2024.109346 · Cited by 1
“That version is capable of sequentially delivering protons and HZE ions in order to simulate a mixed GCR field in the energy range up to 1 GeV/nucleon [8–10].”
BackgroundOvarian issues in human spaceflight
Parada, K. L., & Luderer, U. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22259-7.00018-7 · Cited by 1
Characterizing long-term cosmic ray time series with geometric network curvature metrics
Sierra-Porta, D. (2025) · Journal of Atmospheric and Solar-Terrestrial Physics · doi:10.1016/j.jastp.2025.106418 · Cited by 1
“These e ff ects can have significant implications for ground-based technology (Simonsen et al., 2020), including satellite navigation systems such as GPS, orbiting satellites (H¨oe ff gen et al., 2020; K¨oksal et al., 2021), radio communications, and mobile communications networks (Sharma and…”
Hatsuda, M., Hasegawa, M., Nakamura, K., Yamakura, F., Kobayashi, T., Takanashi, T., Wakabayashi, Y., Otake, Y., Naito, T., & Daida, H. (2025) · Life Sciences in Space Research · doi:10.1016/j.lssr.2025.03.006 · Cited by 1
Helvacıoğlu, S., Cools, B., Ong, J., Waisberg, E., Lee, R. S., Lee, A. G., & Vinken, M. (2025) · Life Sciences in Space Research · doi:10.1016/j.lssr.2025.07.001 · Cited by 3
Xu, X., Blattnig, S. R., & Slaba, T. C. (2025) · Life Sciences in Space Research · doi:10.1016/j.lssr.2025.09.006 · Cited by 1
Self-citationVaghef‐Koodehi, A. (2025) · Functional Materials Letters · doi:10.1142/s179360472551066x · Cited by 2
Augusto, R. D. S., Schaefer, C. W., Lee, R. J., Ferrari, A., & SALA, P. R. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113531 · Cited by 2
Kumar, K., Angdisen, J. J., Fornace, A. J., & Suman, S. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms27010211 · Cited by 1
“This beam composition mimics the charge and energy distribution of the galactic cosmic radiation field experienced beyond Earth’s magnetosphere [5,34].”
Research progress on laser photovoltaic converters for laser wireless power transmission
Sun, Y., Shi, L., Liu, K., Sun, C., Wu, Y., Wan, R., & Guo, H. (2026) · Space Solar Power and Wireless Transmission · doi:10.1016/j.sspwt.2026.01.003 · Cited by 1
Radiation risk mitigation in human space exploration: a primer, a vision, and the state of the art
Narici, L., Baiocco, G., Cenci, G., Micco, V. D., Fraboni, B., Tessa, C. L., Ottolenghi, A., Vincenzo, P., Pugliese, M., Rea, G., et al. (2026) · The European Physical Journal Plus · doi:10.1140/epjp/s13360-025-07199-8 · Cited by 9
“…recently, the Brookhaven NASA’s Galactic Cosmic Ray Simulator based on fast beam switching and control system technology made possible to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep space vehicle [19, 73].”
Fluorescent nuclear track detectors for out‐of‐field neutron dosimetry in proton therapy
Schmidt, S., Muñoz, I. D., Yukihara, E. G., et al. (2026) · Medical Physics · doi:10.1002/mp.70303 · Cited by 1
The heavy ion-induced up-regulation of ZIP14 is mediated by the PKCNrf2 pathway
Zhang, Z., Yuan, J., & Hong, M. (2026) · Life Sciences in Space Research · doi:10.1016/j.lssr.2026.03.001 · Cited by 2
Verma, M., Singh, K. K., Bhogra, A., et al. (2026) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2026.187760 · Cited by 1
Mitigating Radiation Effects on Humans During Space Travel: Recent Developments
Shetgaonkar, G. G., & Kumar, L. (2022) · Springer eBooks · doi:10.1007/978-3-030-05526-4_53 · Cited by 3
Applicability of the NASA galactic cosmic ray simulator for mice, rats, and minipigs
Rahmanian, S., & Slaba, T. C. (2023) · Acta Astronautica · doi:10.1016/j.actaastro.2023.04.016 · Cited by 3
Self-citationMammalian reproduction in spaceflight
Wakayama, S., & Wakayama, T. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22259-7.00002-3 · Cited by 1
The space radiation environment and human health risks
Werneth, C. M., & Huff, J. L. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22259-7.00010-2 · Cited by 2
Metadata
- Authors
- Simonsen, L. C., Slaba, T. C., Guida, P., & Rusek, A.
- Affiliations
- Langley Research Center (US)
- Brookhaven National Laboratory (US)
- Corresponding author
- Simonsen, Lisa C.
- Venue
- PLOS Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-05-19
- Volume
- 18
- Issue
- 5
- Pages
- e3000669
- ISSN
- 1544-9173 (ISSN-L)
- 1545-7885
- PMC
- PMC7236977
- OpenAlex
- W3026227230
- Cited by
- 263
- References
- 42
- Citations by year
- 2026: 39 · 2025: 46 · 2024: 45 · 2023: 34 · 2022: 40 · 2021: 46 · 2020: 13
- FWCI
- 22.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/publicdomain/zero/1.0/ (vor)
- Locations
- PLoS Biology (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- NASA
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Keywords
- galactic cosmic rays, space radiation, low-dose-rate exposure, heavy ions, radiation-induced cancer, central nervous system effects, immunological effects, radiation countermeasures, lunar and Mars missions, NASA Space Radiation Laboratory
- MeSH terms
- Animals, Cosmic Radiation, Humans, Radiobiology, Space Flight, Space Simulation, Mice, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.