NASA's first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index; 11 of the 31 sources its claims cite were checked for support.
Abstract
With exciting new NASA plans for a sustainable return to the moon, astronauts will once again leave Earth's protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPEs with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including circulatory and heart disease, as well as potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy-ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the "GCR Simulator" to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (approximately 65%-75%) and helium ions (approximately 10%-20%) with heavier ions (Z ≥ 3) contributing the remainder. The GCR simulator exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the 5 heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader system is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low-energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires approximately 75 minutes. To more closely simulate the low-dose rates found in space, sequential field exposures can be divided into daily fractions over 2 to 6 weeks, with individual beam fractions as low as 0.1 to 0.2 mGy. In the large beam configuration (60 × 60 cm2), 54 special housing cages can accommodate 2 to 3 mice each for an approximately 75 min duration or 15 individually housed rats. On June 15, 2018, the NSRL made a significant achievement by completing the first operational run using the new GCR simulator. This paper discusses NASA's innovative technology solution for a ground-based GCR simulator at the NSRL to accelerate our understanding and mitigation of health risks faced by astronauts. Ultimately, the GCR simulator will require validation across multiple radiogenic risks, endpoints, doses, and dose rates.
Overview
CoChat Summary
## TL;DR
NASA’s GCR Simulator at NSRL was built to reproduce a shielded deep-space galactic cosmic ray environment using fast sequential beam switching, with a 33-beam reference field normalized to 500 mGy and delivered in about 70–75 minutes. The paper reports that the system was commissioned in 2017 and first used in 2018, enabling mixed-field, chronic, and countermeasure-oriented radiobiology studies in animal and cell models.
## Key findings
- The simulator’s reference field is based on the shielded tissue environment behind 20 g/cm2 aluminum during solar minimum, and is designed to deliver most dose from protons and helium, with heavier ions making up the remainder.
- The full simulator uses 33 sequential beams: 4 proton energies plus degrader, 4 helium energies plus degrader, and 5 heavy ions (C, O, Si, Ti, Fe); a 500 mGy exposure requires approximately 75 minutes.
- For the reference field, the paper reports that Z = 1 ions account for approximately 64% of dose behind 20 g/cm2, Z = 2 ions approximately 17%, and Z ≥ 3 ions approximately 7%; in free space, HZE particles contribute approximately 89% of total dose equivalent.
- Facility tests reported smooth dose distributions in phantoms: the Digimouse organ average dose was 500.7 mGy with soft-tissue variation less than 3%, and the digirat organ average dose was 490.7 mGy with soft-tissue variation less than 5%.
## Methods
- Design paper describing development and implementation of a ground-based GCR simulator at NASA’s Space Radiation Laboratory (NSRL), including reference-field definition, beam selection, facility modifications, animal/cell handling, and dose-rate/fractionation strategy.
- The reference environment was modeled using the Badhwar–O’Neill GCR model, HZETRN transport code, CAD vehicle geometries, human phantoms, Digimouse/digirat voxel models, and Geant4 transport.
- The paper compares alternative implementation strategies (external field, local tissue field, hybrid) and adopts a local tissue approach; analyses include shielding/environment calculations, LET and dose distribution comparisons, and operational testing of beam delivery, dosimetry, and phantoms.
## Limitations
- The paper states that NSRL’s upper energy limit of 1.5 to 2.5 GeV/n is the largest constraint on implementation strategy, and that the simulator does not represent the detailed LET spectra for all shield designs or time in solar cycle.
- It also states that some components are not explicitly simulated, including heavy target fragments from inelastic neutron interactions and π/EM cascades.
- Evident from the text: this is primarily a capability/development paper rather than a completed outcomes study; the “first GCR simulation research studies” are described as ongoing or forthcoming, and most biological results are not reported here.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures

![Fig 2 Relative contribution to fluence (squares), dose (diamonds), and dose equivalent (circles) of different elements in the free-space GCR environment during solar minimum conditions (June 1976) as described by the Badhwar–O'Neill 2010 GCR model [14] (Adapted from Durante and Cucinotta [3]). Plot data available in S1 Data. GCR, galactic cosmic radiation.](https://figures.cochat.ai/paper-figures/3c142d47831149e99ec63c4356a32980/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-2.jpg)
![Fig 3 GCR particle spectra at solar minimum conditions (June 1976) denoted by solid lines and solar maximum conditions (June 2001) denoted by dashed lines in (A) free space and (B) behind 20 g/cm2 of aluminum to female BFOs as described by the Badhwar–O’Neill 2010 GCR model [14], HZETRN transport code [13,16,17], and human phantoms [15,18,19]. Plot data available in S1 Data. BFO, blood-forming organ; GCR, galactic cosmic radiation; HZETRN, High Charge and Energy Transport.](https://figures.cochat.ai/paper-figures/f89b8bf1a48a4a58a3289262b8e0ced5/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-3.jpg)


![Fig 6 Reference field spectra in the female BFOs behind 20 g/cm2 of aluminum shielding during solar minimum conditions. (A) Neutron, hydrogen, and helium energy spectra. (B) The corresponding differential LET spectra with and without contributions from hydrogen and helium. Based on calculations from Slaba and colleagues, 2016 [8]. Plot data available in S1 Data. BFO, blood forming organ; LET, lineal energy transfer.](https://figures.cochat.ai/paper-figures/f3261835f12d4d23a7ee76410333b85d/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-6.jpg)
![Fig 7 Illustration of beam selection strategy for GCR simulator. The total LET spectrum (light blue) and the HZE spectrum (dark blue) are shown separately. The green bars are representative of the number of single-ion beam experiments performed at NSRL as a function of LET (scaled for plot clarity). The black line is representative of ICRP-60 quality factor weighting [11] to estimate biological damage (scaled for plot clarity). Plot data available in S1 Data. GCR, galactic cosmic radiation; HZE, high charge and high energy ions; ICRP, International Commission on Radiological Protection; LET, linear energy transfer; NSRL, NASA Space Radiation Laboratory.](https://figures.cochat.ai/paper-figures/8a620274454c4517995943c613c293c2/nasa-s-first-ground-based-galactic-cosmic-ray-simulator-enabling-a-new-era-in-figure-7.jpg)







Verification
Claims the paper makes
8 Valid · 8 Not valid · 13 Not checked · 114 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The radiation transport code, HZETRN [13,16,17], used to calculate reference field quantities, propagates secondary neutrons and any of their reaction products with charge of Z ≤ 2.”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Methods and models > Determination of GCR reference environment
What the sources say
- Not checked — no full text of the sourcecites [13] JW Wilson, 1991
- Not checked — no full text of the sourcecites [16] TC Slaba, 2010, Faster and more accurate transport procedures for HZETRN, J. Comp. Phys source
- Partly supportedcites [17] TC Slaba, 2010, Coupled neutron transport for HZETRN, Radiat. Meas sourceExperimental — accuracy not yet measured
The Results (p. not available) describe HZETRN transporting neutrons and light ions, including protons, ²H, ³He, and ⁴He. The Conclusions (p. not available) say coupling neutron transport to low-energy light-ion transport is a first-order approximation recommended for use, not an unqualified feature of every HZETRN calculation. The paper also does not establish that *any* neutron reaction product with Z ≤ 2 is propagated. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“A number of radiobiology studies have indicated that the order of exposure to protons and heavy ions may be an important parameter for GCR simulator design due to varied responses observed for different sequences of fractionated doses [31,32].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Methods and models > Implementing the GCR simulator at the NSRL
What the sources say
- Supportedcites [31] SP Sasi, 2017, Different Sequences of Fractionated Low-Dose Proton and Single Iron-Radiation-Induced Divergent Biological Responses in the Heart, Radiation Research source
The Methods compare opposite orders of fractionated proton doses and a single iron-ion dose in mice. The Discussion (Mixed Ion Fractionated Radiation Treatment Groups; page not provided) reports cardiac dysfunction and fibrosis when iron preceded protons, but no negative heart effect over three months when protons preceded iron. The Introduction describes the experiment as emulating a possible space-like environment, supporting the hedged implication that exposure order may matter for simulator design. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [32] G Zhou, 2006, Proton-HZE-Particle sequential dual-beam exposures increase anchorage-independent growth frequencies in primary human fibroblasts, Radiation Research source
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Given the continuous low-dose rates found in space (<1 mGy/day), challenges remain in simulating the galactic cosmic ray environment in Earth-based analogs [4].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Methods and models > Implementing the GCR simulator at the NSRL
What the sources say
- Supportedcites [4] JW Norbury, 2016, Galactic cosmic ray simulation at the NASA Space Radiation Laboratory, Life Sciences in Space Research source
Section 5.1 reports space dose rates of 0.3–0.6 mGy/day and says ground-based experiments generally use much higher rates because of facility and running-time constraints. The Introduction also states that ground-based GCR simulation can only approximate the space environment in dose and dose rate. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“With these control modifications and helium gas provided as a source, ion and energy changes are achieved by a single command in less than 2 minutes [39].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Results > NSRL facility modifications Investments in advanced ion-source technology and control systems were essential to enable a mixed-field irradiation capability. GCR simulator ion beams are extracted from BNL’s Booster synchrotron and transported to the shielded target room within the NSRL facility as shown in Fig 11. Three sources can supply ions to the Booster, including the Linear Accelerator (LINAC; protons only), the Tandem Van de Graaff (ions and protons), and the EBIS (any ion except protons) [39]. The GCR simulator relies on EBIS for helium and heavy ions and either the LINAC or Tandem for protons. EBIS has 2 ports for gas sources that are manually changed to switch between ion species generated. Helium occupies one of those ports during GCR simulations. In late 2013, EBIS was equipped with a laser ion source (LIS), which has the capability to produce ions from many different solid targets as well as to rapidly switch between solid-source targets through automated controls software. Modifications to fit the LIS’s vacuum chamber with a translation table enabled the installation of the specific solid targets needed for the production of 12C, 16O, 28Si, 48Ti, and 56Fe required by the simulator. With these control modifications and helium gas provided as a source, ion and energy changes are achieved by a single command in less than 2 minutes [39]. In late 2016, a variable thickness stripping foil changer was installed at the upstream end of the D6 septum magnet to improve control of source-beam optics after Booster extraction and prior to injection into the NSRL beam line. The foil changer consists of 8 individual thicknesses of foils from 0.25 to 16 mil (6.35 × 10−4 cm to 4.064 × 10−2 cm) with the thinnest foils made of aluminum and the thicker foils (≥1 mil or ≥2.54 × 10−3 cm) made of copper which are remotely controlled in the beam line to provide a range of thicknesses from 0.25 to 63.75 mils (6.35 × 10−4 to 1.619 × 10−1 cm). This upgrade from the previous 2 foil filter system enables better control of the beam shape at the target location in switching from one ion-energy combination to another [39]. In the summer of 2021, EBIS II will be installed replacing the current EBIS and provide the capability for direct gas injection into the beam line. Initial feasibility tests have provided confidence that EBIS II will have the capability to deliver protons to the NSRL and reduce the dependence on LINAC or Tandem as sources. Given the simulator delivers approximately 70% of dose from protons, this upgrade will provide an added level of autonomy and efficiency during operations. The software controlling the order and dose of ion-energy beam combinations to the target is run locally from the NSRL dosimetry console. After ion production at the source, all hardware control settings along the beam lines, including moving species through the EBIS, the transfer line to the Booster (including the big-bend magnet), the Booster itself (injection and extraction), and the NSRL beam line (R-line), must be able to change to sequentially deliver different beams within a reasonable amount of time (Fig 11). A single software application was developed and extensively tested to reliably move from one hardware setting to another. The simulator control file contains the sequential list of ion-energy-dose combinations (Table 3) to which various elements of the accelerator and dosimetry systems must respond in a precisely choreographed sequence. A significant challenge was developing the software architecture to archive and recall the unique hardware control settings for each beam. The ion-energy beam combinations are selected and controlled by the BNL complex-wide Linux cluster while a NSRL local software program controls dose delivered using essentially a dose-based beam cut-off system. Because there are many opportunities for any part of the system to fail at any given time, a means to exit the sequence without overexposing the targets is essential. This was challenging and added much complexity to the software control system. Incremental demonstration of the modified system was successfully demonstrated in 2016 with the delivery of H, Si, and Fe ions to the NSRL target room in a single day. As described previously (see Dose-rate studies), chronic GCR simulations require the delivery of individual beam fractions as low as 0.1 to 0.2 mGy. This represented another significant challenge for operations. In 2017, a series of tests were performed to demonstrate NSRL’s capability to image the beam at such low-dose rates, to retain sufficient monitoring and control over the beam shape, and to reliably measure the low daily doses specified for each beam. The Booster is a synchrotron, so the beam is delivered in “spills,” which last a few seconds. However, the beam can be terminated at a specified dose at any time during a spill. Located behind the biological target (or behind the cage array) is a digital imaging chamber capable of detecting doses as low as 0.05 mGy per beam spill. A cut-off chamber is positioned to intercept the beam at the upstream end of the optical bench or experimental rail system (see Fig 11B), where the beam area is smaller and the dose rate is about 10 times higher. At this location, the cut-off chamber can detect and reliably measure the beam. The cut-off chamber is calibrated against an NIST–(National Institute of Standards and Technology) traceable thimble ion reference chamber placed at the downstream end of the optical bench (in front of the imaging chamber) at the target location. The thimble ion reference chamber has also been verified against scintillation counters with various ions and energies to confirm fluence-dose relationships of delivered beams. Thus, dose calibration is transferred from a sensitive reference chamber at the target location, where the dose rate is low, to a chamber that can cut the accelerator beam off, located where the beam is much more intense. These dosimetry systems were tested at the extremely low doses required for chronic simulations confirming reliability and control over beam parameters. The GCR simulator can be delivered in a 20 × 20 cm2 or in a larger 60 × 60 cm2 beam configuration. Typical dose rates of approximately 10 Gy/min and approximately 0.5 Gy/min are available for the 20 × 20 cm2 and the 60 × 60 cm2 configurations, respectively. Beam uniformity is monitored with segmented thin ion chambers and fluorescent screen techniques during beam preparation and dose delivery. The ion chamber is capable of measuring differences in intensity of 2% to 3% over the 60 × 60 cm2 area. During the 2018 GCR simulator runs, an older variable thickness degrader (binary filter) system was used to deliver the 20 lower energy proton and helium beams to the target from incident beams of 100 MeV/n. The original system was designed to be used with a beam size much smaller than 60 × 60 cm2 and was placed 8-m upstream of the target area to intercept the incident beam where its cross-sectional area was still small (Fig 11B). Because of this distance, the degraded beams arrived at the target with a nonuniform spatial distribution, peaking in the center and reduced to approximately 75% intensity at the corners. This represented a nonuniformity in overall dose of about 4% over the entire 33-beam cycle. During the first GCR simulations in the fall of 2018, animals in exposure cages were limited to the central portion of the large beam, leaving the corner cage boxes vacant, and were rotated through locations within the beam spot during fractionated runs. In 2019, a large-area degrader system was installed approximately 1-m upstream of the target location to enhance spatial uniformity across the 60 × 60 cm2 beam spot (See Fig 11B). This now allows for the full utilization of the beam area and alleviates the need to rotate animal cage positions within the beam spot. The binary filter thicknesses are the same thicknesses as the previous system ranging from 0.1, 0.2, …, 12.8 cm of polyethlylene (with a density of 0.93 g/cm3). The resolution of this system enables verification of incoming beam energies through Bragg curve/range measurements, which is especially important for the lowest energy proton and helium beams utilized in the simulation. Because of its closer proximity to the target, these energy-degraded beams do not lose their shape and maintain good uniformity in dose, intensity, and calibration quality. Prior to experimental runs, set-up and calibration files are tested several times to ensure the control systems are correctly reading files and providing required hardware settings. On a daily basis, operators confirm all ion beams are availble from the EBIS and run various ion-energy beam combinations (H20, He20, Si600, C1000, Ti1000, Fe600) to ensure the cut-off record is automatically created and that calibration and ion chambers readings are correctly recorded. These test runs help capture and track daily drifts in calibration, which are mainly caused by small drifts in beam shape and are typically within 4%. Other uncertainties, or errors, come from the beam cut-off system. The magnitude of the uncertainty depends on the dose delivered from a given ion-energy combination with larger percent errors associated with the smaller doses. Thus, this error is 0.1% to 2% for individual beams and about 0.2% for the cumulative dose delivered by the 33-beam cycle. These measures ensure the stability of the beam over long irradiation periods and over multiple days. Simulator set-up typically requires approximately 1 to 1.5 hours prior to daily experimental runs but can be much longer with unforeseen circumstances. Preparing for Simplified 5-Ion Simulator (Table 6) runs requires significantly less set-up time. Each GCR simulation run requires 21 switches of unique ion-energy beam combinations to the target room. Switch times range between approximately 2 to 4 minutes with longer switch times required for He species to wait for the EBIS to clear prior to the introduction of a new species. The additional 12 beams (lower energy H and He) are generated via the binary filter in the NSRL beam line. Approximately 70 to 75 minutes is required to deliver the doses from all 33 beams for either acute (250 to 750 mGy) or daily fractionated exposures, which may pose a challenge for certain animal or cell model systems. The simplified 5-ion GCR simulation requires approximately 20 to 25 minutes to deliver either acute or fractionated exposures. Additional software records dose over each individual GCR simulation ion as well as cumulative dose for both acute and fractionated dose-rate protocols. Each investigator is provided with a detailed record of the absorbed dose in tissue and the duration of each radiation exposure.
What the sources say
- Partly supportedcites [39] C La Tessa, 2016, Overview of the NASA Space Radiation Laboratory, Life Sci Space Res (Amst) sourceExperimental — accuracy not yet measured
Section 2.3 (p. 7) says control upgrades allow ion and energy changes by a single command in less than two minutes. Section 2.1 (p. 5) mentions two additional gas sources, but does not identify either as helium, so the helium-specific part is unsupported. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“This upgrade from the previous 2 foil filter system enables better control of the beam shape at the target location in switching from one ion-energy combination to another [39].”
§ NASA’s first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research > Results > NSRL facility modifications Investments in advanced ion-source technology and control systems were essential to enable a mixed-field irradiation capability. GCR simulator ion beams are extracted from BNL’s Booster synchrotron and transported to the shielded target room within the NSRL facility as shown in Fig 11. Three sources can supply ions to the Booster, including the Linear Accelerator (LINAC; protons only), the Tandem Van de Graaff (ions and protons), and the EBIS (any ion except protons) [39]. The GCR simulator relies on EBIS for helium and heavy ions and either the LINAC or Tandem for protons. EBIS has 2 ports for gas sources that are manually changed to switch between ion species generated. Helium occupies one of those ports during GCR simulations. In late 2013, EBIS was equipped with a laser ion source (LIS), which has the capability to produce ions from many different solid targets as well as to rapidly switch between solid-source targets through automated controls software. Modifications to fit the LIS’s vacuum chamber with a translation table enabled the installation of the specific solid targets needed for the production of 12C, 16O, 28Si, 48Ti, and 56Fe required by the simulator. With these control modifications and helium gas provided as a source, ion and energy changes are achieved by a single command in less than 2 minutes [39]. In late 2016, a variable thickness stripping foil changer was installed at the upstream end of the D6 septum magnet to improve control of source-beam optics after Booster extraction and prior to injection into the NSRL beam line. The foil changer consists of 8 individual thicknesses of foils from 0.25 to 16 mil (6.35 × 10−4 cm to 4.064 × 10−2 cm) with the thinnest foils made of aluminum and the thicker foils (≥1 mil or ≥2.54 × 10−3 cm) made of copper which are remotely controlled in the beam line to provide a range of thicknesses from 0.25 to 63.75 mils (6.35 × 10−4 to 1.619 × 10−1 cm). This upgrade from the previous 2 foil filter system enables better control of the beam shape at the target location in switching from one ion-energy combination to another [39]. In the summer of 2021, EBIS II will be installed replacing the current EBIS and provide the capability for direct gas injection into the beam line. Initial feasibility tests have provided confidence that EBIS II will have the capability to deliver protons to the NSRL and reduce the dependence on LINAC or Tandem as sources. Given the simulator delivers approximately 70% of dose from protons, this upgrade will provide an added level of autonomy and efficiency during operations. The software controlling the order and dose of ion-energy beam combinations to the target is run locally from the NSRL dosimetry console. After ion production at the source, all hardware control settings along the beam lines, including moving species through the EBIS, the transfer line to the Booster (including the big-bend magnet), the Booster itself (injection and extraction), and the NSRL beam line (R-line), must be able to change to sequentially deliver different beams within a reasonable amount of time (Fig 11). A single software application was developed and extensively tested to reliably move from one hardware setting to another. The simulator control file contains the sequential list of ion-energy-dose combinations (Table 3) to which various elements of the accelerator and dosimetry systems must respond in a precisely choreographed sequence. A significant challenge was developing the software architecture to archive and recall the unique hardware control settings for each beam. The ion-energy beam combinations are selected and controlled by the BNL complex-wide Linux cluster while a NSRL local software program controls dose delivered using essentially a dose-based beam cut-off system. Because there are many opportunities for any part of the system to fail at any given time, a means to exit the sequence without overexposing the targets is essential. This was challenging and added much complexity to the software control system. Incremental demonstration of the modified system was successfully demonstrated in 2016 with the delivery of H, Si, and Fe ions to the NSRL target room in a single day. As described previously (see Dose-rate studies), chronic GCR simulations require the delivery of individual beam fractions as low as 0.1 to 0.2 mGy. This represented another significant challenge for operations. In 2017, a series of tests were performed to demonstrate NSRL’s capability to image the beam at such low-dose rates, to retain sufficient monitoring and control over the beam shape, and to reliably measure the low daily doses specified for each beam. The Booster is a synchrotron, so the beam is delivered in “spills,” which last a few seconds. However, the beam can be terminated at a specified dose at any time during a spill. Located behind the biological target (or behind the cage array) is a digital imaging chamber capable of detecting doses as low as 0.05 mGy per beam spill. A cut-off chamber is positioned to intercept the beam at the upstream end of the optical bench or experimental rail system (see Fig 11B), where the beam area is smaller and the dose rate is about 10 times higher. At this location, the cut-off chamber can detect and reliably measure the beam. The cut-off chamber is calibrated against an NIST–(National Institute of Standards and Technology) traceable thimble ion reference chamber placed at the downstream end of the optical bench (in front of the imaging chamber) at the target location. The thimble ion reference chamber has also been verified against scintillation counters with various ions and energies to confirm fluence-dose relationships of delivered beams. Thus, dose calibration is transferred from a sensitive reference chamber at the target location, where the dose rate is low, to a chamber that can cut the accelerator beam off, located where the beam is much more intense. These dosimetry systems were tested at the extremely low doses required for chronic simulations confirming reliability and control over beam parameters. The GCR simulator can be delivered in a 20 × 20 cm2 or in a larger 60 × 60 cm2 beam configuration. Typical dose rates of approximately 10 Gy/min and approximately 0.5 Gy/min are available for the 20 × 20 cm2 and the 60 × 60 cm2 configurations, respectively. Beam uniformity is monitored with segmented thin ion chambers and fluorescent screen techniques during beam preparation and dose delivery. The ion chamber is capable of measuring differences in intensity of 2% to 3% over the 60 × 60 cm2 area. During the 2018 GCR simulator runs, an older variable thickness degrader (binary filter) system was used to deliver the 20 lower energy proton and helium beams to the target from incident beams of 100 MeV/n. The original system was designed to be used with a beam size much smaller than 60 × 60 cm2 and was placed 8-m upstream of the target area to intercept the incident beam where its cross-sectional area was still small (Fig 11B). Because of this distance, the degraded beams arrived at the target with a nonuniform spatial distribution, peaking in the center and reduced to approximately 75% intensity at the corners. This represented a nonuniformity in overall dose of about 4% over the entire 33-beam cycle. During the first GCR simulations in the fall of 2018, animals in exposure cages were limited to the central portion of the large beam, leaving the corner cage boxes vacant, and were rotated through locations within the beam spot during fractionated runs. In 2019, a large-area degrader system was installed approximately 1-m upstream of the target location to enhance spatial uniformity across the 60 × 60 cm2 beam spot (See Fig 11B). This now allows for the full utilization of the beam area and alleviates the need to rotate animal cage positions within the beam spot. The binary filter thicknesses are the same thicknesses as the previous system ranging from 0.1, 0.2, …, 12.8 cm of polyethlylene (with a density of 0.93 g/cm3). The resolution of this system enables verification of incoming beam energies through Bragg curve/range measurements, which is especially important for the lowest energy proton and helium beams utilized in the simulation. Because of its closer proximity to the target, these energy-degraded beams do not lose their shape and maintain good uniformity in dose, intensity, and calibration quality. Prior to experimental runs, set-up and calibration files are tested several times to ensure the control systems are correctly reading files and providing required hardware settings. On a daily basis, operators confirm all ion beams are availble from the EBIS and run various ion-energy beam combinations (H20, He20, Si600, C1000, Ti1000, Fe600) to ensure the cut-off record is automatically created and that calibration and ion chambers readings are correctly recorded. These test runs help capture and track daily drifts in calibration, which are mainly caused by small drifts in beam shape and are typically within 4%. Other uncertainties, or errors, come from the beam cut-off system. The magnitude of the uncertainty depends on the dose delivered from a given ion-energy combination with larger percent errors associated with the smaller doses. Thus, this error is 0.1% to 2% for individual beams and about 0.2% for the cumulative dose delivered by the 33-beam cycle. These measures ensure the stability of the beam over long irradiation periods and over multiple days. Simulator set-up typically requires approximately 1 to 1.5 hours prior to daily experimental runs but can be much longer with unforeseen circumstances. Preparing for Simplified 5-Ion Simulator (Table 6) runs requires significantly less set-up time. Each GCR simulation run requires 21 switches of unique ion-energy beam combinations to the target room. Switch times range between approximately 2 to 4 minutes with longer switch times required for He species to wait for the EBIS to clear prior to the introduction of a new species. The additional 12 beams (lower energy H and He) are generated via the binary filter in the NSRL beam line. Approximately 70 to 75 minutes is required to deliver the doses from all 33 beams for either acute (250 to 750 mGy) or daily fractionated exposures, which may pose a challenge for certain animal or cell model systems. The simplified 5-ion GCR simulation requires approximately 20 to 25 minutes to deliver either acute or fractionated exposures. Additional software records dose over each individual GCR simulation ion as well as cumulative dose for both acute and fractionated dose-rate protocols. Each investigator is provided with a detailed record of the absorbed dose in tissue and the duration of each radiation exposure.
What the sources say
- Could not verifycites [39] C La Tessa, 2016, Overview of the NASA Space Radiation Laboratory, Life Sci Space Res (Amst) sourceExperimental — accuracy not yet measured
Section 2.2 (p. 7) describes beam shaping with magnets, collimators and shielding blocks; Section 3.6 (p. 16) describes changing beam energy with a range shifter. Searches for a stripping-foil changer, a previous two-foil system and the claimed improvement in beam-shape control found no passage addressing that upgrade. (LLM, conf=0.74)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
60 more claims
Create a free account to see all 143 claims and every source verdict.
- It may state two separate claims as one. 45
- Probably not a substantial claim. 45
- Borderline: one of the tests for a substantial claim is unclear. 1
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“considering that the relative contribution to the GCR total dose is about 40% for protons, 20% for He-ions, 10% for Fe-ions, and 30% for ions between Helium and Iron [38]”
From Radiobiological damage by space radiation: extension of the BIANCA model to heavy ions up to iron, and pilot application to cosmic ray exposure (2022) · cites this paper as [38]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“HZE ions, although a small fraction of the overall GCR spectrum compared to protons, are more biologically damaging. They differ from terrestrial forms of radiation, such as X-rays and gamma-rays, in both the amount (dose) of exposure as well as in the patterns of DNA double-strand breaks and oxidative damage that they impart as they traverse through tissue and cells (Fig. 3)5.”
From Red risks for a journey to the red planet: The highest priority human health risks for a mission to Mars (2020) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Estimates of exposure for a round-trip, Mars planetary expedition are in the range of 870-1200 mSv (Simonsen et al., 2020).”
From Breaking the limit: Biological countermeasures for space radiation exposure to enable long-duration spaceflight (2022) · cites this paper as Simonsen et al., 2020
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Rather than studying single ions it is now possible to simulate the full GCR spectrum on Earth both in USA23 and European24 accelerators and this will pave the way to realistic RBE estimation of the full GCR.”
From Towards sustainable human space exploration—priorities for radiation research to quantify and mitigate radiation risks (2023) · cites this paper as [23]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Outside of the Earth’s protective magnetosphere, crews are exposed to pervasive, low dose-rate galactic cosmic rays (GCR) and to intermittent solar particle events (SPEs)5.”
From Red risks for a journey to the red planet: The highest priority human health risks for a mission to Mars (2020) · cites this paper as [5]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 2×
“The voxel models have been coupled to the Monte Carlo transport code, Geant4 [33], for radiation transport of single-particle beams and the complete 33 ion beam GCR simulator.”
MethodHealth Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Recommendations of the International Commission on Radiological Protection
(1959) · Health Physics · doi:10.1097/00004032-195901000-00001 · Cited by 1,703
Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
(2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 904
Measurements of energetic particle radiation in transit to Mars on the Mars Science Laboratory
Zeitlin, C., Hassler, D. M., Cucinotta, F. A., Ehresmann, B., Wimmer-Schweingruber, R. F., Brinza, D. E., Kang, S., Weigle, G., Böttcher, S., Böhm, E., et al. (2013) · Science · doi:10.1126/science.1235989 · Cited by 641
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528 · cited 4×
“Physical shielding strategies designed to significantly reduce the health risks from GCR become prohibitively costly because of the high charge (Z) and energy (E) of the primary constituent particles, referred to as high charge and high energy (HZE) particles, and from the production of secondary protons, neutrons, an…”
BackgroundMethodInfluential(1991) · NASA STI Repository (National Aeronautics and Space Administration) · Cited by 384
Self-citationSpace radiation risks to the central nervous system
Cucinotta, F. A., Alp, M., Sulzman, F. M., & Wang, M. (2014) · Life Sciences in Space Research · doi:10.1016/j.lssr.2014.06.003 · Cited by 262 · cited 1×
“Computational analyses of accelerator GCR simulations have shown that a large percentage of cells will be hit with 2 or more particles in simulated chronic exposures of a week or less and recommend exposures of several weeks with times approaching 30 days or longer to avoid any high dose-rate artifacts [36,37].”
BackgroundKramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239 · cited 2×
“[13,16,17], vehicle computer-aided design (CAD) geometries, and human phantoms [15,18,19].”
BackgroundMethodSpace Radiation Cancer Risk Projections and Uncertainties – 2012
Cucinotta, F. A., Y.Kim, M.-H., & Chappell, L. J. (2013) · NASA · doi:10.13140/rg.2.1.1413.3528 · Cited by 218
Research works printed but not linked: 2
- National Research Council (NRC), 2006, BEIR VII Phase 2 report
- International Commission on Radiological Protection (ICRP), 1991, ICRP Publication 60
Cited by
Fundamental Biological Features of Spaceflight: Advancing the Field to Enable Deep-Space Exploration
Afshinnekoo, E., Scott, R. T., MacKay, M. J., Pariset, E., Cekanaviciute, E., Barker, R., Gilroy, S., Hassane, D., Smith, S. M., Zwart, S. R., et al. (2020) · Cell · doi:10.1016/j.cell.2020.10.050 · Cited by 478
“Currently available simulators of low dose rate irradiation include gamma ray flood sources (Bellone et al., 2016), a chronic neutron irradiation animal facility (Borak et al., 2019), and a series of low-dose, fractionated irradiations at NSRL. Cell.”
MethodInfluentialPatel, Z. S., Brunstetter, T. J., Tarver, W. J., Whitmire, A. M., Zwart, S. R., Smith, S. M., & Huff, J. L. (2020) · npj Microgravity · doi:10.1038/s41526-020-00124-6 · Cited by 373
Human Health during Space Travel: State-of-the-Art Review
Krittanawong, C., Singh, N. K., Scheuring, R. A., Urquieta, E., Bershad, E. M., Macaulay, T. R., Kaplin, S., Dunn, C., Kry, S. F., Russomano, T., et al. (2022) · Cells · doi:10.3390/cells12010040 · Cited by 170
“NASA has recently developed a space radiation simulator, named the “GCR Simulator”, which allows for the more accurate radiobiologic research into the development and mitigation of radiation-induced malignancies [139].”
BackgroundFactors mediating spaceflight-induced skeletal muscle atrophy
Lee, P. H. U., Chung, M., Ren, Z., Mair, D. B., & Kim, D. (2022) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00203.2021 · Cited by 122
Circulating miRNA Spaceflight Signature Reveals Targets for Countermeasure Development
Malkani, S., Chin, C. R., Cekanaviciute, E., Mortreux, M., Okinula, H., Tarbier, M., Schreurs, A., Shirazi‐Fard, Y., Tahimic, C. G. T., Rodríguez, D. N., et al. (2020) · Cell Reports · doi:10.1016/j.celrep.2020.108448 · Cited by 84
“Irradiations were carried out at Brookhaven National Lab using 50cGy of SimGCRSim (5-ion simplified galactic cosmic ray simulation: protons at 1000MeV, 28 Si at 600 MeV/n, 4 He at 250 MeV/n, 16 O at 350 MeV/n, 56 Fe at 600 MeV/n, and protons at 250 MeV).”
InfluentialGuo, J., Zeitlin, C., Wimmer-Schweingruber, R. F., Hassler, D. M., Ehresmann, B., Rafkin, S., Freiherr von Forstner, J. L., Khaksarighiri, S., Liu, W., & Wang, Y. (2021) · The Astronomy and Astrophysics Review · doi:10.1007/s00159-021-00136-5 · Cited by 73
“Recognizing these issues, steps have recently been taken at the NASA Space Radiation Laboratory to better align the exposures given to model systems with crew exposures, including the provision of mixed radiation fields, lower dose rates, and protracted exposures (Simonsen et al. 2020).”
MethodMechanical energy metamaterials in interstellar travel
Jiao, P. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101132 · Cited by 81
Tomsia, M., Cieśla, J., Śmieszek, J., Florek, S., Macionga, A. A., Michalczyk, K., & Stygar, D. M. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1284644 · Cited by 136
Fogtman, A., Baatout, S., Baselet, B., Berger, T., Hellweg, C. E., Jiggens, P., La Tessa, C., Narici, L., Nieminen, P., Sabatier, L., et al. (2023) · npj Microgravity · doi:10.1038/s41526-023-00262-7 · Cited by 70
Biology and crop production in Space environments: Challenges and opportunities
Pascale, S. D., Arena, C., Aronne, G., Micco, V. D., Pannico, A., Paradiso, R., & Rouphael, Y. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2021.02.005 · Cited by 91
Neuro-consequences of the spaceflight environment
Mhatre, S. D., Iyer, J. S., Puukila, S., Paul, A. M., Tahimic, C. G. T., Rubinstein, L., Lowe, M. G., Alwood, J. S., Sowa, M. B., Bhattacharya, S., et al. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.09.055 · Cited by 68
Genomic Changes Driven by Radiation-Induced DNA Damage and Microgravity in Human Cells
Beheshti, A., McDonald, J. T., Hada, M., Takahashi, A., Mason, C. E., & Mognato, M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910507 · Cited by 100
Willey, J. S., Britten, R. A., Blaber, E. A., Tahimic, C. G. T., Chancellor, J., Mortreux, M., Sanford, L. D., Kubik, A. J., Delp, M. D., & Mao, X. W. (2021) · Journal of Environmental Science and Health Part C · doi:10.1080/26896583.2021.1885283 · Cited by 78
“2017;10;8(10):2117 [102] Simonsen LC, Slaba TC, Guida P, Rusek A.”
Carcinogenesis induced by space radiation: A systematic review
Guo, Z., Zhou, G., & Hu, W. (2022) · Neoplasia · doi:10.1016/j.neo.2022.100828 · Cited by 98
Krukowski, K., Grue, K. A., Becker, M., Elizarraras, E., Frias, E. S., Halvorsen, A. T., Koenig-Zanoff, M., Frattini, V., Nimmagadda, H., Feng, X., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg6702 · Cited by 87
“This protocol is one of two NASA-approved simulations of the galactic cosmic ray environment that can be produced by the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) ( 15 ).”
InfluentialBiological research and self-driving labs in deep space supported by artificial intelligence
Sanders, L. M., Scott, R. T., Yang, J. H., Qutub, A. A., Garcia Martin, H., Berrios, D. C., Hastings, J. J. A., Rask, J., Mackintosh, G., Hoarfrost, A. L., et al. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00618-4 · Cited by 49
“The majority of current space biology knowledge originated through ground-analogue experiments 27,28 , satellites in LEO 17 , and from experiments on the Space Shuttle 29 or the International Space Station (ISS) 30,31 .”
BackgroundEffects of spaceflight on the brain
Seidler, R. D., Mao, X. W., Tays, G. D., Wang, T., & zu Eulenburg, P. (2024) · The Lancet Neurology · doi:10.1016/s1474-4422(24)00224-2 · Cited by 67
Boice, J. D., Quinn, B. M., Al‐Nabulsi, I., Ansari, A. J., Blake, P. K., Blattnig, S. R., Caffrey, E., Cohen, S. S., Golden, A. P., Held, K. D., et al. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2021.1988183 · Cited by 60
“Exposures can also be relatively high, with a mission to Mars estimated to be of the order of 300–450 mGy (870–1200 mSv) (Simonsen et al. 2020).”
BackgroundInfluentialHuff, J. L., Poignant, F., Rahmanian, S., Khan, N., Blakely, E. A., Britten, R. A., Chang, P. Y., Fornace, A. J., Hada, M., Kronenberg, A., et al. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.09.001 · Cited by 67
Self-citationMortality among workers at the Los Alamos National Laboratory, 1943–2017
Boice, J. D., Cohen, S. S., Mumma, M. T., Golden, A. P., Howard, S. C., Girardi, D. J., Ellis, E. D., Bellamy, M. B., Dauer, L. T., Samuels, C. E., et al. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2021.1917784 · Cited by 54
Hirayama, J., Hattori, A., Takahashi, A., Furusawa, Y., Tabuchi, Y., Shibata, M., Nagamatsu, A., Yano, S., Maruyama, Y., Matsubara, H., et al. (2022) · Journal of Pineal Research · doi:10.1111/jpi.12834 · Cited by 48
“Understanding the effects of space radiation in detail is essential to improve the safety of space missions.(180) At low‐Earth orbit, where the ISS is located (altitude of 300–400 km; orbital inclination of 51.”
BackgroundPaul, A. M., Cheng-Campbell, M., Blaber, E. A., Anand, S., Bhattacharya, S., Zwart, S. R., Crucian, B. E., Smith, S. M., Meller, R., Grabham, P. W., et al. (2020) · iScience · doi:10.1016/j.isci.2020.101747 · Cited by 40
Improving astronaut cancer risk assessment from space radiation with an ensemble model framework
Simonsen, L. C., & Slaba, T. C. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2021.07.002 · Cited by 36
Self-citationGalactic cosmic radiation exposure causes multifaceted neurocognitive impairments
Alaghband, Y., Klein, P., Kramár, E. A., Cranston, M. N., Perry, B. C., Shelerud, L. M., Kane, A. E., Doan, N.-L., Ru, N., Acharya, M. M., et al. (2023) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-022-04666-8 · Cited by 44
Earth-Based Research Analogs to Investigate Space-Based Health Risks
Cromwell, R. L., Huff, J. L., Simonsen, L. C., & Patel, Z. S. (2021) · New Space · doi:10.1089/space.2020.0048 · Cited by 43
Self-citationMiller, K. B., Mi, K. L., Nelson, G. A., Norman, R. B., Patel, Z. S., & Huff, J. L. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1008640 · Cited by 42
“that are four to ten times greater (Norbury et al., 2016; Simonsen et al., 2020) (Figure 2).”
BackgroundA Mission to Mars: Prediction of GCR Doses and Comparison with Astronaut Dose Limits
Ramos, R. L., Carante, M. P., FERRARI, A., SALA, P. R., Vercesi, V. I., & Ballarini, F. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032328 · Cited by 37
Wadhwa, A., Moreno‐Villanueva, M., Crucian, B. E., & Wu, H. (2024) · Immunity & Ageing · doi:10.1186/s12979-024-00449-w · Cited by 45
“Radiation encountered by astronauts during spaceflight largely consists of galactic cosmic radiation (GCR) that originates outside the solar system [51].”
BackgroundDetrimental impacts of mixed-ion radiation on nervous system function
Klein, P., Parihar, V. K., Szabo, G. G., Zöldi, M., Angulo, M. C., Allen, B. D., Amin, A. N., Nguyen, Q.-A., Katona, I., Baulch, J. E., et al. (2021) · Neurobiology of Disease · doi:10.1016/j.nbd.2021.105252 · Cited by 39
“…multi-ion GCR irradiation produce a similar scope of cognitive deficits, there remains debate concerning how accurately the full GCR spectrum experienced in space must be recapitulated to sufficiently assess the hazards that future astronauts will face (Norbury et al. 2016; Simonsen et al. 2020).”
BackgroundMethodInfluentialCardiovascular Disease Risk Modeling for Astronauts: Making the Leap From Earth to Space
Huff, J. L., Plante, I., Blattnig, S. R., Norman, R. B., Little, M. P., Khera, A., Simonsen, L. C., & Patel, Z. S. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.873597 · Cited by 39
Self-citationSpace radiation damage rescued by inhibition of key spaceflight associated miRNAs
McDonald, J. T., Kim, J., Farmerie, L., Johnson, M. L., Trovão, N. S., Arif, S., Siew, K., Tsoy, S., Bram, Y., Park, J., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48920-y · Cited by 38
Consequences of space radiation on the brain and cardiovascular system
Davis, C. M., Allen, A. R., & Bowles, D. E. (2021) · Journal of Environmental Science and Health Part C · doi:10.1080/26896583.2021.1891825 · Cited by 35
“Only recently have studies been performed with the new GCR simulation capabilities where multiple ions and energies are delivered in a single exposure.(6) JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH.”
BackgroundChauhan, V., Hamada, N., Monceau, V., Ebrahimian, T. G., Adam, N., Wilkins, R. C., Sebastian, S., Patel, Z. S., Huff, J. L., Simonetto, C., et al. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2021.1969466 · Cited by 34
“2018), the risk would be relevant after longer missions to Mars, where astronauts would be exposed to multiple stressors including galactic cosmic rays (Patel et al. 2020; Simonsen et al. 2020).”
BackgroundDose-Effects Models for Space Radiobiology: An Overview on Dose-Effect Relationships
Strigari, L., Strolin, S., MORGANTI, A. G., & Bartoloni, A. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.733337 · Cited by 37
“Experiments performed at the NASA Space Radiation Laboratory revealed that heavy ions induce expression of the TGF-β1 isoform, which canmodulate late post-radiation changes and increase the risk of tumor development and metastasis even when cells were irradiated with doses as low as 0.1Gy (63).”
BackgroundInfluentialVerma, S. D., de la Chapelle, E. P., Malkani, S., Juran, C. M., Boyko, V., Costes, S. V., & Cekanaviciute, E. (2022) · Frontiers in Immunology · doi:10.3389/fimmu.2022.864923 · Cited by 41
Long term food stability for extended space missions: a review
Watkins, P., Hughes, J., Gamage, T. V., Knoerzer, K., Ferlazzo, M. L., & Banati, R. B. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2021.12.003 · Cited by 37
Hybrid Active-Passive Space Radiation Simulation Concept for GSI and the Future FAIR Facility
Schuy, C., Weber, U., & Durante, M. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.00337 · Cited by 27
Spaceflight Stressors and Skin Health
Radstake, W. E., Baselet, B., Baatout, S., & Verslegers, M. (2022) · Biomedicines · doi:10.3390/biomedicines10020364 · Cited by 33
“Researchers at the NASA Space Radiation Laboratory (NSRL) have developed a GCR Simulator which overcomes this limitation by using fast beam switching to be able to expose samples to a variety of ion beams and, as such, gives a better representation of the space radiation spectrum to be experienced by astronauts in dee…”
BackgroundMicrostructural changes in GaN and AlN under 950 MeV Au swift heavy ion irradiation
Mahfuz, M., Reza, F., Liu, X., et al. (2024) · Applied Physics Letters · doi:10.1063/5.0189812 · Cited by 26
Brains in space: impact of microgravity and cosmic radiation on the CNS during space exploration
Wuyts, F. L., Deblieck, C., Vandevoorde, C., & Durante, M. (2025) · Nature reviews. Neuroscience · doi:10.1038/s41583-025-00923-4 · Cited by 40
“However, the sequential GCR field can be delivered in daily fractions over several weeks, with individual beam fractions as low as 0.1–0.2 mGy 220 .”
InfluentialRaber, J., Holden, S. J., Sudhakar, R., Hall, R., Glaeser, B., Lenarczyk, M., Rockwell, K., Nawarawong, N. N., Sterrett, J., Perez, R., et al. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.746509 · Cited by 26
“The simGCRsim beam set was designed to broadly represent the distribution of primary and secondary ions produced behind shielding in a spacecraft or habitat, which is where crew members will spend the majority of their time on extended exploratory class missions (Simonsen et al., 2020).”
BackgroundMethodInfluentialSoler, I., Yun, S., Reynolds, R. P., Whoolery, C. W., Tran, F. H., Kumar, P. L., Rong, Y., DeSalle, M. J., Gibson, A. D., Stowe, A. M., et al. (2021) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2021.722780 · Cited by 28
Keiser, A. A., Kramár, E. A., Dong, T. N., Shanur, S., Pirodan, M., Ru, N., Acharya, M. M., Baulch, J. E., Limoli, C. L., & Wood, M. A. (2020) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2020.107367 · Cited by 30
“Such information provides scientists the opportunity to simulate these exposures on earth using animal models (Simonsen et al., 2020) in efforts to extrapolate these findings to human health risks.”
BackgroundInfluentialSleep Fragmentation Exacerbates Executive Function Impairments Induced by Low Doses of Si Ions
Britten, R. A., Fesshaye, A. S., Duncan, V. D., Wellman, L. L., & Sanford, L. D. (2020) · Radiation Research · doi:10.1667/rade-20-00080.1 · Cited by 25
“Astronauts on the proposed mission to Mars are estimated to receive ;30 cGy SR (2, 3).”
Method8-OxodG: A Potential Biomarker for Chronic Oxidative Stress Induced by High-LET Radiation
Kumar, K., Fornace, A. J., & Suman, S. (2024) · DNA · doi:10.3390/dna4030015 · Cited by 29
“…the scenarios of high-LET radiation exposure are quite limited: (1) astronauts undertaking deep space exploration beyond Earth’s magnetosphere [40,41], (2) patients undergoing high-LET cancer radiotherapy using proton or carbon beams [42], (3) exposure to neutron radiation originated from a…”
BackgroundBoutros, S. W., Zimmerman, B., Nagy, S. C., Lee, J. S., Perez, R., & Raber, J. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.770502 · Cited by 28
Desai, R. I., Kangas, B. D., Luc, O. T., Solakidou, E., Smith, E. C., Dawes, M. H., Ma, X., Makriyannis, A., Chatterjee, S., Dayeh, M. A., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42173-x · Cited by 29
Kiffer, F. C., Luitel, K., Tran, F. H., Patel, R., Guzman, C. S., Soler, I., Xiao, R., Shay, J. W., Yun, S., & Eisch, A. J. (2021) · Behavioural Brain Research · doi:10.1016/j.bbr.2021.113677 · Cited by 26
Wuu, Y. R., Hu, B., Okunola, H. L., Paul, A. M., Blaber, E. A., Cheng-Campbell, M., Beheshti, A., & Grabham, P. W. (2020) · iScience · doi:10.1016/j.isci.2020.101771 · Cited by 24
Everything you wanted to know about space radiation but were afraid to ask
Chancellor, J. C., Nowadly, C. D., Williams, J. P., Auñón-Chancellor, S. M., Chesal, M., Looper, J., & Newhauser, W. D. (2021) · Journal of Environmental Science and Health Part C · doi:10.1080/26896583.2021.1897273 · Cited by 49
Late onset cardiovascular dysfunction in adult mice resulting from galactic cosmic ray exposure
Bishawi, M. M., Lee, F. H., Abraham, D., Glass, C., Blocker, S. J., Cox, D. J., Brown, Z. D., Rockman, H. A., Mao, L., Slaba, T. C., et al. (2022) · iScience · doi:10.1016/j.isci.2022.104086 · Cited by 28
“Mice that had been exposed to 150 cGy of GCR5-ion demonstrated significant diminishment in load-dependent measures of cardiac function, including stroke work (SW) (Figure 3A), stroke volume (SV) (Figure 3B), (A) Experimental set up included c57BL/6 mice undergoing radiation at six months of age with sham radiation con…”
BackgroundInfluentialSelf-citationLuoni, F., Boscolo, D., Fiore, G., Bocchini, L., Horst, F., Reidel, C.-A., Schuy, C., Cipriani, C., Binello, A., Baricco, M., et al. (2022) · Radiation Research · doi:10.1667/rade-22-00147.1 · Cited by 29
“However, this is important for biological experiments (45), while with materials, one could conceivably construct a GCR simulator by collecting singlebeam data on the same target.”
BackgroundRapid Loss of Fine Motor Skills after Low Dose Space Radiation Exposure
Blackwell, A. A., Fesshaye, A. S., Tidmore, A., Lake, R. I., Wallace, D. G., & Britten, R. A. (2022) · Behavioural Brain Research · doi:10.1016/j.bbr.2022.113907 · Cited by 25
Cope, H., Willis, C. R. G., MacKay, M. J., Rutter, L. A., Toh, L. S., Williams, P. M., Herranz, R., Borg, J., Bezdan, D., Giacomello, S., et al. (2022) · Patterns · doi:10.1016/j.patter.2022.100550 · Cited by 24
Santosh, K. C., & Abolfath, R. (2022) · Scientific Reports · doi:10.1038/s41598-022-23727-3 · Cited by 25
Modeling and countering the effects of cosmic radiation using bioengineered human tissues
Tavakol, D. N., Nash, T. R., Kim, Y., He, S., Fleischer, S., Graney, P. L., Brown, J. A., Liberman, M., Tamargo, M. A., Harken, A. D., et al. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122267 · Cited by 25
Everything you wanted to know about space radiation but were afraid to ask
Chancellor, J. C., Nowadly, C. D., Williams, J. P., Auñón-Chancellor, S. M., Chesal, M., Looper, J., & Newhauser, W. D. (2021) · Civil War Book Review · Cited by 20
Rienecker, K. D. A., Grue, K. A., Paladini, M. S., Frias, E. S., Frattini, V., Borlongan, M. C., Chou, A., Espin, A. T., Krukowski, K., Ferguson, A. R., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-28508-0 · Cited by 19
“188), but individually were correlated for 0 cGy group housed (r(7) = 0.”
BackgroundMitochondrial stress in the spaceflight environment
Rudolf, A. M., & Hood, W. R. (2024) · Mitochondrion · doi:10.1016/j.mito.2024.101855 · Cited by 21
Roy, M. K., Carpia, F. L., Cendali, F. I., Fernando, S., Moriconi, C., Wójczyk, B. S., Wang, L., Nemkov, T. G., Hod, E. A., & D’Alessandro, A. (2022) · Journal of Proteome Research · doi:10.1021/acs.jproteome.1c00912 · Cited by 19
Ramos, R. L., Embriaco, A., Carante, M. P., Ferrari, A., Sala, P., Vercesi, V., & Ballarini, F. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac6991 · Cited by 17
“C-ions were considered as representative of the ions between Helium and Iron.”
InfluentialAbdullaev, S. A., Glukhov, S. I., & Gaziev, A. I. (2021) · Antioxidants · doi:10.3390/antiox10121885 · Cited by 24
“In this case, it happens that the main risks are mostly associated with the possible consequences of cosmic irradiation’s effects on the central nervous system and spleen, which lead to potential neurological disorders, degenerative effects, and decrease in the immune system and affect many aspects of the crew’s healt…”
BackgroundSexual dimorphism during integrative endocrine and immune responses to ionizing radiation in mice
Burke, M., Wong, K., Talyansky, Y., Mhatre, S. D., Mitchell, C., Juran, C. M., Olson, M., Iyer, J. S., Puukila, S., Tahimic, C. G. T., et al. (2024) · Scientific Reports · doi:10.1038/s41598-023-33629-7 · Cited by 21
Effects of Low Dose Space Radiation Exposures on the Splenic Metabolome
Laiakis, E. C., Shuryak, I., Deziel, A., Wang, Y.-W., Barnette, B. L., Yu, Y., Ullrich, R. L., Fornace, A. J., & Emmett, M. R. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22063070 · Cited by 18
“It is estimated that a mission to Mars lasting between 650 and 920 days will lead to a dose equivalent of 870–1200 mSv (300–450 mGy) [42].”
BackgroundSchaeffer, E. A., Blackwell, A. A., Oltmanns, J. R. O., Einhaus, R. M., Lake, R. I., Hein, C., Baulch, J. E., Limoli, C. L., Ton, S. T., Kartje, G. L., et al. (2021) · Behavioural Brain Research · doi:10.1016/j.bbr.2021.113577 · Cited by 16
“The 33 exposures were delivered in order, energy, and dose as previously described [29].”
MethodPlante, I., Poignant, F., & Slaba, T. C. (2021) · Life · doi:10.3390/life11111112 · Cited by 20
“In future work, we intend to use this approach and investigate the effect of radiation transport in digital mice to better represent radiation environment in vivo cells experience in ground-based experiments [42], and for microdosimetry calculation for realistic Galactic Cosmic Ray beams with or without shielding.”
MethodSelf-citationUnraveling astrocyte behavior in the space brain: Radiation response of primary astrocytes
Roggan, M. D., Kronenberg, J., Wollert, E., Hoffmann, S., Nisar, H., Konda, B., Diegeler, S., Liemersdorf, C., & Hellweg, C. E. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1063250 · Cited by 22
“GCR simulation composed of protons, helium nuclei and selected heavy ions became only recently available at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratories (BNL) (7).”
MethodThe biomedical challenge associated with the Artemis space program
Bizzarri, M., Gaudenzi, P., & Angeloni, A. (2023) · Acta Astronautica · doi:10.1016/j.actaastro.2023.07.021 · Cited by 19
Response of Arabidopsis thaliana and Mizuna Mustard Seeds to Simulated Space Radiation Exposures
Zhang, Y., Richards, J. T., Feiveson, A. H., Richards, S. E., Neelam, S., Dreschel, T. W., Plante, I., Hada, M., Wu, H., Massa, G. D., et al. (2022) · Life · doi:10.3390/life12020144 · Cited by 16
“Although current Earth-based radiation facilities can only approximately reproduce the space-radiation environment, recent improvements in technology can be utilized to improve our knowledge about the effect of space radiation on crop plants [15].”
BackgroundDynan, W. S., Chang, P. Y., Sishc, B. J., & Elgart, S. R. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.10.003 · Cited by 12
Fu, S., Ding, Z., Zhang, Y., Zhang, X., Li, C., Li, G., Tang, S. W., Zhang, H., Xu, Y., Wang, Y., et al. (2022) · The Astrophysical Journal Letters · doi:10.3847/2041-8213/ac80f5 · Cited by 16
“The main sources of these particles are Galactic cosmic rays (GCRs), which are highly energetic and highly penetrating particles (Simonsen et al. 2020).”
BackgroundBioSentinel: Validating Sensitivity of Yeast Biosensors to Deep Space Relevant Radiation
Liddell, L. C., Gentry, D. M., Gilbert, R., Marina, D. B., Tieze, S. M., Padgen, M. R., Akiyama, K., Keenan, K., Bhattacharya, S., & Maria, S. R. S. (2023) · Astrobiology · doi:10.1089/ast.2022.0124 · Cited by 15
Impact of galactic cosmic ray simulation on nutritional content of foods
Douglas, G. L., Cooper, M. P. I., Wu, H., Gaza, R., Guida, P. M., & Young, M. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2020.12.001 · Cited by 14
Self-citationMicco, V. D., Francesco, S. D., Amitrano, C., & Arena, C. (2021) · Plants · doi:10.3390/plants10112272 · Cited by 16
“Currently, the re-supply of resources is still an open issue, as for short-duration missions supplies are entirely shipped from Earth.”
BackgroundInfluentialSleiman, A., Miller, K. B., Flores, D., Kuan, J., Altwasser, K., Smith, B. J., Kozbenko, T., Hocking, R., Wood, S. J., Huff, J. L., et al. (2024) · Environmental and Molecular Mutagenesis · doi:10.1002/em.22622 · Cited by 16
Holden, S. J., Perez, R., Hall, R., Fallgren, C. M., Ponnaiya, B., Garty, G. Y., Brenner, D. J., Weil, M. M., & Raber, J. (2021) · Radiation Research · doi:10.1667/rade-20-00228.1 · Cited by 13
“1, the LET distribution for the high-LET component of simulated GCR at Brookhaven National Laboratory (Upton, NY) (27, 28) is compared with those calculated based on spectroscopic measurements (14, 15) for the fields used in this study.”
BackgroundMethodFemale astronauts: Impact of space radiation on menopause
Rose, B. I. (2022) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2022.02.022 · Cited by 13
Stati, G., Passaretta, F., Gindraux, F., Centurione, L., & Pietro, R. D. (2021) · Life · doi:10.3390/life11121437 · Cited by 14
“This approach allows relating the biological effects of space radiation to effects from similar exposure to ground-based gamma rays and X-rays to extrapolate the results to large human epidemiological cohorts [6,7].”
BackgroundAcute, Low-Dose Neutron Exposures Adversely Impact Central Nervous System Function
Klein, P., Alaghband, Y., Doan, N.-L., Ru, N., Drayson, O. G. G., Baulch, J. E., Kramár, E. A., Wood, M. A., Soltész, I., & Limoli, C. L. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22169020 · Cited by 14
“To probe the impact of acute neutron irradiation on the central nervous system, adult male mice received a single 18 cGy dose of whole body neutron irradiation, equivalent to an expected dose received by astronauts in transit to Mars [3,33].”
BackgroundVitale, E., Izzo, L. G., Amitrano, C., Velikova, V., Tsonev, T. D., Simoniello, P., Micco, V. D., & Arena, C. (2022) · Plants · doi:10.3390/plants11141816 · Cited by 12
“Carbon (C) and titanium (Ti) are among the heavy ions considered representative of HZE and are often used to simulate the GRC spectrum in ground-based experiments [14,15].”
BackgroundHaptic Systems: Trends and Lessons Learned for Haptics in Spacesuits
Kuhail, M. A., Berengueres, J. O. L., Taher, F., Al-Kuwaiti, M. H. H., & Khan, S. (2023) · Electronics · doi:10.3390/electronics12081888 · Cited by 15
Biomedical Research Programs at Present and Future High-Energy Particle Accelerators
Patera, V., Prezado, Y., Azaiez, F., Battistoni, G., Bettoni, D., Brandenburg, S., Bugay, A. N., Cuttone, G., Dauvergne, D., de France, G., et al. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.00380 · Cited by 16
RRx-001 and the “Right stuff”: Protection and treatment in outer space
Oronsky, B., Caroen, S., Abrouk, N., & Reid, T. R. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.05.001 · Cited by 11
Kidane, Y. H., Lee, F. H., Smith, M. F., Wang, C., Mirza, J. B., Sharma, S., Lobo, A. A., Dewan, K. C., Chen, J., Diaz, T. E., et al. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1248276 · Cited by 11
Werneth, C. M., Patel, Z. S., Thompson, M. S., Blattnig, S. R., & Huff, J. L. (2024) · Communications Medicine · doi:10.1038/s43856-023-00408-4 · Cited by 13
“Two main categories of health risks associated with space radiation exposure are cancers and cardiovascular disease 2 .”
BackgroundInfluence of the spaceflight environment on macrophage lineages
An, R., Blackwell, V. K., Harandi, B. F., Gibbons, A. C., Siu, O., Irby, I., Rees, A., Cornejal, N., Sattler, K. M., Sheng, T., et al. (2024) · npj Microgravity · doi:10.1038/s41526-023-00293-0 · Cited by 16
Tang, Y. M., Ip, W. H., Yung, K. L., & Bi, Z. (2024) · Journal of Industrial Information Integration · doi:10.1016/j.jii.2024.100721 · Cited by 16
Lenarczyk, M., Kronenberg, A., Mäder, M., KOMOROWSKI, R. A., Hopewell, J. W., & Baker, J. E. (2023) · PLoS ONE · doi:10.1371/journal.pone.0283877 · Cited by 13
A Current Overview of the Biological Effects of Combined Space Environmental Factors in Mammals
Xu, Y., Pei, W., & Hu, W. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.861006 · Cited by 14
Kozbenko, T., Adam, N., Grybas, V. S., Smith, B. J., Alomar, D., Hocking, R., Abdelaziz, J., Pace, A., Boerma, M., Azimzadeh, O., et al. (2024) · Environmental and Molecular Mutagenesis · doi:10.1002/em.22636 · Cited by 15
“Heavy ions present a particular challenge due to their large contribution to the dose equivalent and high ionization potential, making them capable of creating secondary particles as they penetrate shielding (Cucinotta et al., 2006; Simonsen et al., 2020).”
Microglia: Rheostats of space radiation effects in the CNS microenvironment
Kerry O'Banion, M. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.08.002 · Cited by 10
Suman, S., & Fornace, A. J. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.09.005 · Cited by 14
Effects of neutron radiation generated in deep space-like environments on food resources
Hatsuda, M., Kawasaki, H., Shigenaga, A., Taketani, A., Takanashi, T., Wakabayashi, Y., Otake, Y., Kamata, Y., Ichinose, A., Nishioka, H., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-38990-1 · Cited by 12
Brojakowska, A., Jackson, C. J., Bisserier, M., Khlgatian, M. K., Jagana, V., Eskandari, A., Grano, C., Blattnig, S. R., Zhang, S., Fish, K. M., et al. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1292033 · Cited by 10
Ramos, R. L., Carante, M. P., Bernardini, E., FERRARI, A., SALA, P. R., Vercesi, V. I., & Ballarini, F. (2024) · Life Sciences in Space Research · doi:10.1016/j.lssr.2024.03.006 · Cited by 17
“At solar minimum, the doses involved for sustained lunar operations of 1-year duration have been estimated to be in the range 0.10 – 0.12 Gy, corresponding to 0.18 – 0.22 Gy-Eq or 0.3 – 0.4 Sv (Simonsen et al., 2020).”
InfluentialDauer, L. T., Mumma, M. T., Lima, J. C., Cohen, S. S., Andresen, D., Bahadori, A. A., Bellamy, M. B., Bierman, D. A., Blattnig, S. R., French, B. C., et al. (2024) · Radiation Research · doi:10.1667/rade-23-00186.1 · Cited by 11
“Furthermore, future missions that operate outside of LEO will experience prolonged exposures with increased cumulative doses from the complex radiation environment of GCR, including the energetic high-LET heavy ions found therein ( 79 ).”
Why Do the Cosmic Rays Induce Aging?
Giovanetti, A., Tortolici, F., & Rufini, S. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00955 · Cited by 12
“HZE ions penetrate by many centimeters, producing along their track large ionizations’ clusters, differently from the more uniform energy depositions by low LET radiation (Simonsen et al., 2020).”
BackgroundVivas, J. A. R., Navarro-González, R., de la Rosa, J., Molina, P., Sedov, S., & McKay, C. P. (2020) · Astrobiology · doi:10.1089/ast.2020.2257 · Cited by 13
“Protons account for * 87% of the total flux of galactic cosmic rays with kinetic energies spanning from 0.2 to 160 GeV (Simonsen et al. , 2020).”
InfluentialWhat can space radiation protection learn from radiation oncology?
Tinganelli, W., Luoni, F., & Durante, M. (2021) · Life Sciences in Space Research · doi:10.1016/j.lssr.2021.06.002 · Cited by 15
Yun, S., Kiffer, F. C., Bancroft, G. L., Guzman, C. S., Soler, I., Haas, H. A., Shi, R., Patel, R., Lara‐Jiménez, J., Kumar, P. L., et al. (2024) · Journal of Neurochemistry · doi:10.1111/jnc.16225 · Cited by 14
“However, particle accelerators have been limited in the number of particle types and energies that can be generated in a reasonable time-frame (Simonsen et al., 2020).”
Influential
Metadata
- Authors
- Simonsen, L. C., Slaba, T. C., Guida, P., & Rusek, A.
- Affiliations
- Langley Research Center (US)
- Brookhaven National Laboratory (US)
- Corresponding author
- Simonsen, Lisa C.
- Venue
- PLOS Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-05-19
- Volume
- 18
- Issue
- 5
- Pages
- e3000669
- ISSN
- 1544-9173 (ISSN-L)
- 1545-7885
- PMC
- PMC7236977
- OpenAlex
- W3026227230
- Cited by
- 263
- References
- 42
- Citations by year
- 2026: 39 · 2025: 46 · 2024: 45 · 2023: 34 · 2022: 40 · 2021: 46 · 2020: 13
- FWCI
- 22.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/publicdomain/zero/1.0/ (vor)
- Locations
- PLoS Biology (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- NASA
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Keywords
- galactic cosmic rays, space radiation, low-dose-rate exposure, heavy ions, radiation-induced cancer, central nervous system effects, immunological effects, radiation countermeasures, lunar and Mars missions, NASA Space Radiation Laboratory
- MeSH terms
- Animals, Cosmic Radiation, Humans, Radiobiology, Space Flight, Space Simulation, Mice, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.