Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There is interest in using convolutional neural networks (CNNs) to analyze medical imaging to provide computer-aided diagnosis (CAD). Recent work has suggested that image classification CNNs may not generalize to new data as well as previously believed. We assessed how well CNNs generalized across three hospital systems for a simulated pneumonia screening task. METHODS AND FINDINGS: A cross-sectional design with multiple model training cohorts was used to evaluate model generalizability to external sites using split-sample validation. A total of 158,323 chest radiographs were drawn from three institutions: National Institutes of Health Clinical Center (NIH; 112,120 from 30,805 patients), Mount Sinai Hospital (MSH; 42,396 from 12,904 patients), and Indiana University Network for Patient Care (IU; 3,807 from 3,683 patients). These patient populations had an age mean (SD) of 46.9 years (16.6), 63.2 years (16.5), and 49.6 years (17) with a female percentage of 43.5%, 44.8%, and 57.3%, respectively. We assessed individual models using the area under the receiver operating characteristic curve (AUC) for radiographic findings consistent with pneumonia and compared performance on different test sets with DeLong's test. The prevalence of pneumonia was high enough at MSH (34.2%) relative to NIH and IU (1.2% and 1.0%) that merely sorting by hospital system achieved an AUC of 0.861 (95% CI 0.855-0.866) on the joint MSH-NIH dataset. Models trained on data from either NIH or MSH had equivalent performance on IU (P values 0.580 and 0.273, respectively) and inferior performance on data from each other relative to an internal test set (i.e., new data from within the hospital system used for training data; P values both <0.001). The highest internal performance was achieved by combining training and test data from MSH and NIH (AUC 0.931, 95% CI 0.927-0.936), but this model demonstrated significantly lower external performance at IU (AUC 0.815, 95% CI 0.745-0.885, P = 0.001). To test the effect of pooling data from sites with disparate pneumonia prevalence, we used stratified subsampling to generate MSH-NIH cohorts that only differed in disease prevalence between training data sites. When both training data sites had the same pneumonia prevalence, the model performed consistently on external IU data (P = 0.88). When a 10-fold difference in pneumonia rate was introduced between sites, internal test performance improved compared to the balanced model (10× MSH risk P < 0.001; 10× NIH P = 0.002), but this outperformance failed to generalize to IU (MSH 10× P < 0.001; NIH 10× P = 0.027). CNNs were able to directly detect hospital system of a radiograph for 99.95% NIH (22,050/22,062) and 99.98% MSH (8,386/8,388) radiographs. The primary limitation of our approach and the available public data is that we cannot fully assess what other factors might be contributing to hospital system-specific biases. CONCLUSION: Pneumonia-screening CNNs achieved better internal than external performance in 3 out of 5 natural comparisons. When models were trained on pooled data from sites with different pneumonia prevalence, they performed better on new pooled data from these sites but not on external data. CNNs robustly identified hospital system and department within a hospital, which can have large differences in disease burden and may confound predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, the system was able to distinguish only which machine was used for imaging and not the risk of the patients.”
From Explainability for artificial intelligence in healthcare: a multidisciplinary perspective (2020) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In a study training AI to diagnose pneumonia from chest X-rays, the performance on unseen data from the institution where the training data were collected was significantly higher than its performance on data collected from external hospitals [72].”
From Fairness of artificial intelligence in healthcare: review and recommendations (2024) · cites this paper as [72]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Shortcut learning, in which a model latches onto a spurious correlate (eg, the scanner used at a particular site, a hospital-specific text template) rather than the clinical signal of interest, has been repeatedly documented in medical AI and can be difficult to detect without deliberate probing.62”
From Artificial Intelligence in Oncology: Practical Applications Across Clinical Care, Scholarship, and Translation. (2026) · cites this paper as [62]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This study hypothesized that multicenter training could enhance the generalizability of AI models, which has previously been demonstrated in other medical imaging scenarios25–27.”
From Federated deep learning for detecting COVID-19 lung abnormalities in CT: a privacy-preserving multinational validation study (2021) · cites this paper as [26]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, variations in data collection and processing can degrade model accuracy on data from new hospital deployments (Zech et al., 2018; AlBadawy et al., 2018).”
From WILDS: A Benchmark of in-the-Wild Distribution Shifts (2020) · cites this paper as Zech et al., 2018
12 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 2×
“Many different CNN architectures have been proposed, including ResNet-50 and DenseNet-121 used in this paper, and improving the performance of these models is an active area of research [14,15].”
MethodLeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDensely Connected Convolutional Networks
Huang, G., Liu, Z., van der Maaten, L., & Weinberger, K. Q. (2016) · arXiv · doi:10.48550/arxiv.1608.06993 · Cited by 48,960
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
(2017) · Cited by 11,625
Cited by
Items 901–1,000 of 1,005
Balancing Performance and Interpretability in Medical Image Analysis: Case study of Osteopenia
Mikulić, M., Vičević, D., Nagy, E., Napravnik, M., Štajduhar, I., Tschauner, S., & Hržić, F. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01194-8 · Cited by 6
“Zech et al. [27] found that pneumonia detection in chest radiographs was affected by internal hospital-specific biases.”
Zhang, F., Cheng, J., Xu, P., Zhang, C., Qu, L., Zhang, S., Zhang, J., & Zhu, S. (2025) · Theranostics · doi:10.7150/thno.105500 · Cited by 5
Measuring the Intracluster Light Fraction with Machine Learning
Canepa, L., Brough, S., Lanusse, F., Montes, M., & Hatch, N. A. (2025) · The Astrophysical Journal · doi:10.3847/1538-4357/adabc7 · Cited by 10
Wasinger, G., Koeller, M. C., & Compérat, É. (2025) · Diagnostic histopathology · doi:10.1016/j.mpdhp.2025.04.003 · Cited by 6
Raymond, C., Yao, J., Kolkovsky, A. L. L., Feiweier, T., Clifford, B., Meyer, H., Zhong, X., Han, F., Cho, N. S., Sanvito, F., et al. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-025-05094-x · Cited by 7
“Additionally, the ATHENA model was trained using single-site data across multiple scanners, which may restrict its generalizability across different vendor platforms and institutional protocols, a common challenge in medical imaging AI [49, 50].”
Detecting the Undetected: Machine Learning in Early Disease Diagnosis
Rathi, K., Sharma, S., & Barnwal, A. P. (2025) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/bcpt.70104 · Cited by 4
“The quality of the data used to train ML models is paramount [80].”
Enzo Raschio, A., Cassandra Contreras, R., Felipe Allende, N., & Pablo Maturana, Q. (2021) · Revista de Fomento Social · doi:10.4067/s0717-93082021000100008 · Cited by 8
Levine, E. V. (2023) · Communications of the ACM · doi:10.1145/3606946 · Cited by 3
PNA-DCN: A Deep Convolution Network to Detect the Pneumonia Disease
Trivedi, R. B., Sahani, A., & Goyal, S. R. (2023) · Lecture notes in networks and systems · doi:10.1007/978-981-99-5085-0_11 · Cited by 4
A Systematic Review of Medical Expert Systems for Cardiac Arrest Prediction
Kaur, I., Ahmad, T., & Doja, M. N. (2023) · Current Bioinformatics · doi:10.2174/0115748936251658231002043812 · Cited by 5
Feng, R., Valliani, A. A.-A., Martini, M. L., Gal, J. S., Neifert, S. N., Kim, N. C., Geng, E. A., Kim, J., Cho, S. K.-W., Oermann, E. K., et al. (2024) · Clinical Spine Surgery A Spine Publication · doi:10.1097/bsd.0000000000001520 · Cited by 4
“16,17 In another Electronic Health Record – based study, Dexter and colleagues developed a model for diagnosing a few speci fi c infectious diseases.”
Self-citationRivera, S. C., Liu, X., Chan, A., Denniston, A. K., Calvert, M., y CONSORT-AI, G. D. T. S.-A., y CONSORT-AI, G. D. S.-A., & y CONSORT-AI, G. D. C. S.-A. (2024) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2024.12 · Cited by 8
A survey on medical image analysis using deep reinforcement learning approach
Shaikh, K. A.-H. (2024) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2024.21.2.0294 · Cited by 4
Worldwide research landscape of artificial intelligence in lung disease: A scientometric study
Zeng, M., Wang, X., & Chen, W. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e31129 · Cited by 4
Expected Integral Discrete Gradient: Diagnosing Autonomous Driving Model
Li, M., Sun, H., Cui, Z., Huang, Y., & Chen, H. (2024) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2024.3436614 · Cited by 4
“Formally, within this kind of approach, given a model f : R n → R , for an n - dimensional input x , feature attribution assigns a contribution value atr i ( x ; Therefore, it could be utilized within a machine learning-driven field to explain the prediction [17], [18].”
IMIL: Interactive Medical Image Learning Framework
Rao, A., Fisher, A. T., Chang, K., Panagides, J., McNamara, K. L., Lee, J.-Y., & Aalami, O. (2024) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw63382.2024.00533 · Cited by 7
“A focused algorithm should not only be able to make correct predictions but should make these predictions based on relevant regions of the medical image and at the same time, avoid spurious correlations from irrelevant parts of the image [38, 41].”
Deep learning for biomedical applications
Freitas, J. D., Glicksberg, B. S., Johnson, K. W., & Miotto, R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820273-9.00004-x · Cited by 5
Sabottke, C. F., Breaux, M. A., Lee, R., Foreman, A., & Spieler, B. M. (2021) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-021-00443-4 · Cited by 4
Adversarial Scrutiny of Evidentiary Statistical Software
Abebe, R., Hardt, M., Jin, A., Miller, J. A., Schmidt, L., & Wexler, R. (2022) · ACM Conference on Fairness, Accountability, and Transparency (FAccT) · doi:10.1145/3531146.3533228 · Cited by 17
“Scholars have observed that evaluation studies of machine learning systems are often over-optimistic estimates of performance on new test cases; the performance of these systems can drop dramatically under slight variations of the test distribution [17, 30, 67, 74, 97, 121].”
BackgroundLearn decision trees with deep visual primitives
Xue, M., Zhang, H., Huang, Q., Song, J., & Song, M. (2022) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2022.103682 · Cited by 5
Intelligent prognostic system for pediatric pneumonia based on sustainable IoHT
Sasikaladevi, N., & Revathi, A. A. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-14930-z · Cited by 4
“Deep learning models for pneumonia from CXR images are well studied by the researchers [12, 16, 19, 20, 23, 24, 31, 38, 44, 52, 56] for adults.”
BackgroundMachine learning technologies in CT-based diagnostics and classification of intracranial hemorrhages
Сморчкова, А. К., Khoruzhaya, A. N., Kremneva, E. I., & Petryaikin, A. V. (2023) · Burdenko s Journal of Neurosurgery · doi:10.17116/neiro20238702185 · Cited by 5
Furtado, F., Romero, Á. B., Hesami, M., Mostafavi, L., Najmi, Z., Queiroz, M. A., Mojtahed, A., Anderson, M., & Catalano, O. A. (2023) · Abdominal Radiology · doi:10.1007/s00261-023-03907-z · Cited by 5
“By using a machine learning approach to extract human-interpretable semantic features, the resultant algorithm is not affected by manufacturer shift or center-related bias that could throw off a deep learning model or require expensive annotation and re-training on new data [35, 36].”
MethodLeveraging Comprehensive Health Records for Breast Cancer Risk Prediction: A Binational Assessment
Chorev, M., Barros, V., Spiro, A., Evron, E., Barkan, E., Kagan, O., Amit, M., Ozery-Flato, M., Akselrod-Ballin, A., Shalev, V., et al. (2023) · PubMed Central · doi:10.5281/zenodo.11368013 · Cited by 5
Kikoo, D., Tamin, B., Hardjadilaga, S., Anderies, A., & Iswanto, I. A. (2023) · JOIV International Journal on Informatics Visualization · doi:10.30630/joiv.7.2.1015 · Cited by 4
“However, this dataset only contains 40 [41].”
Mullan, S. M., & Milan Sonka, A. (2023) · Journal of medical imaging · doi:10.1117/1.jmi.10.5.054001 · Cited by 3
“4 Within the domain of medical imaging, there are two key types of task that deep learning models have been applied to.”
BackgroundIdentification of pneumonia based on chest x-ray images using wavelet scattering network
Zaben, S. O., & Ali, A. E. (2021) · Periodicals of Engineering and Natural Sciences (PEN) · doi:10.21533/pen.v9i2.1953 · Cited by 4
“[37] investigated and tested the performance of ChexNet training on an internal dataset of pneumonia and normal medical CXRs.”
Deciphering musculoskeletal artificial intelligence for clinical applications: how do I get started?
Mutasa, S., & Yi, P. H. (2021) · Skeletal Radiology · doi:10.1007/s00256-021-03850-4 · Cited by 4
Understanding And Manipulating Neural Net Features Using Sparse Oblique Classification Trees
Hada, S. S., Carreira-Perpiñán, M. Á., & Zharmagambetov, A. S. (2021) · Proceedings - International Conference on Image Processing · doi:10.1109/icip42928.2021.9506373 · Cited by 4
“with previous works that have found that, in some specific cases, the reason why a deep net classifies an object as a certain class is caused by the background or more generally by some confounding variables [12, 35].”
Wehbe, R. M., & Thomas, J. D. (2022) · JAMA Cardiology · doi:10.1001/jamacardio.2022.0193 · Cited by 4
Data Poisoning Attack and Defenses in Connectome-Based Predictive Models
Rosenblatt, M., & Scheinost, D. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-23223-7_1 · Cited by 4
Zero-Shot Domain Adaptation in CT Segmentation by Filtered Back Projection Augmentation
Saparov, T., Kurmukov, A. G., Shirokikh, B., & Belyaev, M. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-88210-5_24 · Cited by 6
Deep Convolutional Neural Networks (CNNs) to Detect Abnormality in Musculoskeletal Radiographs
Rath, M., Reddy, P. S. D., & Singh, S. K. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-84760-9_10 · Cited by 4
Underwhelming Generalization Improvements From Controlling Feature AttributionPreprint
Viviano, J. D., Simpson, B., Dutil, F., Bengio, Y., & Cohen, J. (2019) · arXiv (Cornell University) · Cited by 4
Deep Learning Improves Predictions of the Need for Total Knee Replacement
Richardson, M. L. (2020) · Radiology · doi:10.1148/radiol.2020202332 · Cited by 5
Disrupting Model Training with Adversarial ShortcutsPreprint
Evtimov, I., Covert, I., Kusupati, A., & Kohno, T. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.06654 · Cited by 9
“…trained models often rely on non-robust, localized, texture-based features (Zhang et al., 2016; Jo & Bengio, 2017; Madry et al., 2017; Geirhos et al., 2018; Ilyas et al., 2019), and, when available, confounders or shortcuts (Zech et al., 2018; Badgeley et al., 2019; DeGrave et al., 2021).”
MethodChallenges for cognitive decoding using deep learning methodsPreprint
Thomas, A. W., Ré, C., & Poldrack, R. A. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2108.06896 · Cited by 7
Barnett, A. J., Guo, Z., Jing, J., Ge, W., Kaplan, P. W., Kong, W. Y., Karakis, I., Herlopian, A., Jayagopal, L. A., Taraschenko, O., et al. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2211.05207 · Cited by 4
“Specifically, uninterpretable (or “black box”) models are prone to silent failures during clinical operations due to either poor generalization or over-reliance on trivial medically irrelevant features 16;17 .”
BackgroundSharafutdinov, K., Fritsch, S. J., Iravani, M., Ghalati, P. F., Saffaran, S., Bates, D. G., Hardman, J. G., Polzin, R., Mayer, H., Marx, G., et al. (2022) · medRxiv · doi:10.1101/2022.12.02.22283033 · Cited by 4
Slomka, P. J., & Miller, R. J. H. (2023) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2023.01.018 · Cited by 4
Validation is not enough: Longitudinal evidence of post-deployment fragility in clinical AI systems
Kopanitsa, G. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001534 · Cited by 9
“In medical imaging, Zech et al. showed that a pneumonia detection model learned site-specific and non-clinical confounders, resulting in large performance differences across hospitals despite strong internal validation [14].”
Brink, L., Romero, R. A., Coombs, L. P., Tilkin, M., Mazaheri, S., Gichoya, J. W., Zaiman, Z., Trivedi, H., Medina, A., Bizzo, B. C., et al. (2024) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2024.11.003 · Cited by 3
Assessing Generalization Capabilities of Malaria Diagnostic Models from Thin Blood Smears
Guillon, L., Biga, S., Puyo, A., Pasquier, G., Foucher, V., Kantchire, Y. E., Sossou, S. E., Dorkenoo, A. M., Bonnardot, L., Théllier, M., et al. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-82007-6_14 · Cited by 3
“[20].”
BackgroundMethodGeneralizing machine learning models from clinical free text
Pandian, B., Vandervest, J., Mentz, G. B., Varghese, J., Steadman, S., Kheterpal, S., Makar, M., Vydiswaran, V. G. V., & Burns, M. L. (2025) · Scientific Reports · doi:10.1038/s41598-025-17197-6 · Cited by 3
Artificial Intelligence in Ocular Oncology: Differentiating Choroidal Melanocytic Lesions
Harby, L. A., Korot, E., Keane, P. A., Lally, S. E., Ferenczy, S. R., Dalvin, L. A., Pellegrini, M., Duker, J. S., Fung, A. T.-C., Kaliki, S., et al. (2025) · Ophthalmology Science · doi:10.1016/j.xops.2025.100948 · Cited by 4
Wu, J., Tang, X., Zheng, Q., Gu, X., Ma, L. M., Xian, J., Mao, H. Z., Gan, J., & Ji, G. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1695749 · Cited by 3
Procházka, A., & Zeman, J. (2025) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2025.104963 · Cited by 6
Duke, S. A., Sandøe, P., Lund, T. B., Abenavoli, E. M., Beyer, T., Ferrara, D., Frille, A., Grünert, S., Sabri, O., Sciagrà, R., et al. (2025) · AI and Ethics · doi:10.1007/s43681-025-00837-y · Cited by 4
Gete, K. Y., & Ayele, A. A. (2025) · BMC Neurology · doi:10.1186/s12883-025-04528-3 · Cited by 9
“Generalizability was the dominant limitation: performance declined on external cohorts, consistent with known site-and scanner-shift effects [31].”
Thomas, N. R., Anitha, J., Popîrlan, C., Popirlan, C.-I., & Hemanth, D. J. (2025) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2025.070689 · Cited by 5
“Models trained on controlled datasets do not perform as well in heterogeneous, real-world imaging environments due to variability in factors such as quality, protocols, and ground truth labels [137,138].”
Bias-Mitigated AI as a Foundation for Resilient and Effective Health Systems
Júnior, J. B. D. S., Birminghamm, M., Rivière-Cinnamond, A., Boisson, E., Valdez, M. L., García-Saisó, S., Souza, J. P., Martí, M., Richards, L.-M. L.-M., Guzman, J., et al. (2026) · JMIR Public Health and Surveillance · doi:10.2196/88457 · Cited by 5
“An algorithm trained in a high-resource tertiary hospital may perform poorly in a rural clinic with different patient demographics and resources [9].”
Gong, M., Wu, Z., He, Y., Xiao, J., Men, X., & Chen, H. (2026) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545826300053 · Cited by 5
Shen, Y., Chen, Q., He, X., Agrawal, R. V., Grzybowski, A. E., Jin, K., & Ye, X. (2026) · Ophthalmology and Therapy · doi:10.1007/s40123-026-01316-1 · Cited by 4
“Biases arising from uneven representation of disease stages, patient demographics, or geographical regions can lead to suboptimal performance in specific populations [60].”
Transparent reporting is central to reproducible radiological AI research: A call to action
White, S. J., Yaxley, K. L., To, M., & Chau, M. T. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112777 · Cited by 4
Alkhatatbeh, T., Alkhatatbeh, A., Liao, Y., Zhang, Z., Fang, H., Chen, W., & Zhang, R. (2026) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.70254 · Cited by 6
“Following established protocols for medical imaging domain adaptation [ 15–17 ], we evaluated two transfer scenarios: (1) zero-shot inference using the OAI-trained model without modification, and (2) selective fine-tuning on the external target domain.”
InfluentialFaa, G., Lai, E., Cau, F., Coghe, F., Rugge, M., Suri, J. S., Codipietro, C., Congiu, B., Graziano, S., Tiwari, E., et al. (2026) · Cancers · doi:10.3390/cancers18071184 · Cited by 5
“Publicly available datasets may contain slides originating from a limited number of institutions, scanners, or staining protocols [90,91].”
Coombs, L. P., Brink, L., Kim, W., Wald, C., Schmidt, K., Tilkin, M., Dreyer, K., Cook, T. S., & Bizzo, B. C. (2026) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2026.04.024 · Cited by 8
Wi, C.-I., Overgaard, S. M., Malik, M., Watson, D., Sharma, D., Le‐Rademacher, J. G., Kelleher, D. P., Zheng, L., Ohde, J. W., Lynch, B., et al. (2026) · Journal of the National Medical Association · doi:10.1016/j.jnma.2026.04.001 · Cited by 7
Padmanabhan, K., Lu, M., Feng, D., Kan‐Dobrosky, N., Konduri, S., Litman, H. J., & Livieratos, A. (2026) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocag077 · Cited by 4
“The risk of deploying non-explainable ML systems has been demonstrated by several real-world examples: Zech et al. (2018) [19] proved that a deep learning model for pneumonia detection relied on hospital-specific artifacts on the chest X-rays rather than actual pathology; Caruana et al. (2015) [20]…”
Saraboji, K., Gopalakrishnan, K., Sood, D., Kaur, A., Shivaram, S., Helgeson, S. A., Arunachalam, S. P., & Mitra, D. (2026) · AI in Medicine · doi:10.3390/aimed1020016 · Cited by 4
“This often-neglected stage is essential for maintaining safety and effectiveness over time [22].”
InfluentialErdoğan, H. M., & Koç, U. (2026) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-026-02084-x · Cited by 3
Survey of the Knowledge of Korean Radiology Residents on Medical Artificial Intelligence
Lee, H., Park, S. H., Kim, C., Kim, S., & Cha, J. (2020) · Journal of the Korean Society of Radiology · doi:10.3348/jksr.2019.0179 · Cited by 3
“최근 인공지능에 대한 관심이 증가함에 따라 의료 분야에서 딥러닝(deep learning) 모델이 갖 는 취약성에 대해 논의가 되는 등(11-14), 인공지능에 대한 과도한 기대감을 경계하는 목소리가 커 지고 있다(6, 8, 13, 15, 16).”
Deep learning: Opening a third eye to myocardial perfusion imaging
Hagio, T., & Murthy, V. L. (2022) · Journal of Nuclear Cardiology · doi:10.1007/s12350-022-02959-w · Cited by 3
“[14] in which a DL algorithm for chest radiography performed significantly worse on external data compared to internal data (data from the same institution as training data).”
Zhang, R., Griner, D., Garrett, J. W., Qi, Z., & Chen, G. (2023) · Scientific Reports · doi:10.1038/s41598-023-39855-3 · Cited by 6
“A major challenge is poor generalizability, where performance significantly drops when applied to external datasets 1–3 .”
BackgroundLiu, X., Rivera, S. C., Moher, D., Calvert, M., Denniston, A. K., & y CONSORT-AI, G. D. T. S.-A. (2024) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2024.13 · Cited by 6
Interpretable Classifier Models for Decision Support Using High Utility Gain Patterns
Krishnamoorthy, S. (2024) · IEEE Access · doi:10.1109/access.2024.3455563 · Cited by 7
“In the healthcare domain, Zech et al [4], analyze the performance of a black-box model for predicting pneumonia in chest radiographs.”
BackgroundArtificial Neural Networks: A New Frontier in Dental Tissue Regeneration
Nor, N. H. M., Mansor, N. I., & Hasim, N. A. (2024) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2024.0216 · Cited by 4
Patel, R., Price, N., Bahr, R. H., Bedrick, S. D., Bensoussan, Y. E., Bélisle‐Pipon, J., Dorr, D. A., Jackson, C., Krussel, A., Cruz, S. S., et al. (2024) · Frontiers in Digital Health · doi:10.3389/fdgth.2024.1484503 · Cited by 3
Pang, W. M., Liew, T. W., Tan, S.-M., Teo, S. C., Lee, Y. Y., & Lim, T. Q. (2024) · World Symposium on Software Engineering (WSSE) · doi:10.1145/3698062.3698093 · Cited by 6
“Consequently, AI techniques are now widely employed for tasks like disease detection, identification, prediction, and diagnosis [6, 7].”
Radiology AI Lab: Evaluation of Radiology Applications with Clinical End-Users
Paalvast, O., Sevenster, M., Hertgers, O., de Bliek, H., Wijn, V., Buil, V., Knoester, J., Vosbergen, S., & Lamb, H. J. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01453-2 · Cited by 5
“Despite growing research interest and increasing industry investments, the anticipated widespread adoption of AI-drive workflow enhancements has yet to materialise] [2–5].”
Yu, W., McNitt‐Gray, M. F., Goldin, J. G., Song, J. W., & Kim, G. H. J. (2025) · Medical Physics · doi:10.1002/mp.17752 · Cited by 3
CAD: Computer-Aided Detection of Pneumonia Using Convolutional Neural Networks (CNN)
Jain, M., Shah, A., Sharma, P. R., & Campisi, M. (2025) · International Journal of Computer Science and Mobile Computing · doi:10.47760/ijcsmc.2025.v14i05.005 · Cited by 6
In-context learning for label-efficient cancer image classification in oncology
Shrestha, M., Mandal, B., Mandal, V., Shrestha, A., & Shrestha, A. B. (2025) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2025.101683 · Cited by 8
Harnessing Large Language Models for Digital Building Logbook Implementation
Urlainis, A., Giat, Y., & Mitelman, A. (2025) · Buildings · doi:10.3390/buildings15183399 · Cited by 4
“In addition to LLMs, other ML-based methods, such as CNNs, have been proved successful at interpreting visual data, such as pneumonia screenings [43].”
A Generalized Deep Learning Model for Multi-disease Chest X-Ray Diagnostics
Bajwa, N., Bajwa, K., Shakeel, M. F., Rana, A. I., Haqqi, K., & Khan, S. A. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-43085-5_43 · Cited by 3
da Costa, N. J. C., Sousa, J., Santos, D. B. S., Marques, F., & de Melo, R. T. (2020) · Revista Brasileira de Computação Aplicada · doi:10.5335/rbca.v12i3.10343 · Cited by 6
The clinicians’ perspectives on machine learning
Pattarabanjird, T., & McNamara, C. A. (2022) · Nature Cardiovascular Research · doi:10.1038/s44161-022-00033-9 · Cited by 3
Bastida, J. P. C., Pearson, E. A., & Al‐Hallaq, H. (2022) · Journal of medical imaging · doi:10.1117/1.jmi.9.4.045002 · Cited by 5
“13,28,29 For example, it could be possible that image edges contain fingerprints of the hardware where the patient was scanned, which may correlate with the anatomic class since patients of the same treatment site are often grouped on the same treatment machine.”
BackgroundPneumonia Detection from Chest X-Ray Images Using Deep Learning Methods
Christopher, L., Margharet, A. A., Shiny, B., Tigga, S., & George, S. T. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-2177-3_60 · Cited by 3
Generating novel pituitary datasets from open-source imaging data and deep volumetric segmentation
Gologorsky, R., Harake, E. S., von Oiste, G. G., Nasir-Moin, M., Couldwell, W. T., Oermann, E. K., & Hollon, T. C. (2022) · Pituitary · doi:10.1007/s11102-022-01255-7 · Cited by 4
“…dataset of relatively normal imaging to investigate the classification of pituitary pathol - ogy, and to generate a normal control group for training Confounding factors, such as different patient populations, imaging protocols, and systems, can impact a model’s generalization performance [32 ].”
BackgroundSelf-citationAn Artificial Intelligence Outlook for Colorectal Cancer Screening
Katrakazas, P., Ballas, A., Anisetti, M., & Spais, I. (2022) · IEEE International Conference on Big Data Computing Service and Applications (BigDataService) · doi:10.1109/bigdataservice55688.2022.00018 · Cited by 5
“Furthermore, the majority of deep learning models fail to generalize adequately on previously ‘unseen’ data [29].”
BackgroundMedical Radiology Image processing for Pneumonia Detection Using Convolutional Neural Network
Singh, V., Manay, A., Singh, R. P., Tomer, S., Chandan, A., Darapaneni, N., Manoj, V., Rastogi, A., & Paduri, A. R. (2023) · IEEE Annual Computing and Communication Workshop and Conference (CCWC) · doi:10.1109/ccwc57344.2023.10099292 · Cited by 3
“They found out that a more generalized model is needed to detect pneumonia in all sorts of clinical settings [21].”
BackgroundArtificial intelligence in healthcare
Argenson, A., & Devi-Chou, V. (2023) · Principles of Gender-Specific Medicine · doi:10.1016/b978-0-323-88534-8.00025-0 · Cited by 4
Müller, N. M., Jacobs, J., Williams, J. R., & Böttinger, K. (2023) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw59228.2023.00382 · Cited by 6
“Chest X-ray images have been previously found to contain shortcuts [26], especially when obtained from multiple sources, such as different hospitals.”
BackgroundMin, K. (2023) · Journal of Veterinary Clinics · doi:10.17555/jvc.2023.40.4.243 · Cited by 4
Hernandez, S., Burger, H., Nguyen, C. M., Paulino, A. C., Lucas, J. T., Faught, A. M., Duryea, J., Netherton, T., Rhee, D. J., Cardenas, C. E., et al. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1221792 · Cited by 3
Bridging the Source-Target Mismatch with Pseudo Labeling for Neonatal Seizure Detection
Daly, A., Lightbody, G., & Temko, A. (2023) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco58844.2023.10290015 · Cited by 4
“This source of performance reduction is also seen in other domain areas such as medical imaging applications [8], cross language models in NLP [9] and microbiology [10].”
BackgroundWang, S., Liu, Y., Zhang, H., & Liu, Z. (2024) · BMC Bioinformatics · doi:10.1186/s12859-024-05745-2 · Cited by 3
“This word only indicated the type of the X-ray machine rather than the medical knowledge [32].”
BackgroundUllah, M. A., Zia, T., Kim, J.-E., & Kadry, S. (2024) · PLoS ONE · doi:10.1371/journal.pone.0311879 · Cited by 4
RetractedCausal debiasing for unknown bias in histopathology—A colon cancer use case
Correa, R., Pai, R. K., Ebare, K., Buchanan, D. D., Jenkins, M. A., Phipps, A. I., Newcomb, P. A., Gallinger, S., Grant, R. C., Marchand, L. L., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0303415 · Cited by 3
A Pipeline for Automated Quality Control of Chest Radiographs
Selby, I., González-Solares, E., Breger, A., Roberts, M., Sánchez, L. E., Babar, J. L., Rudd, J. H. F., Walton, N. A., Sala, E., Schönlieb, C., et al. (2025) · Radiology Artificial Intelligence · doi:10.1148/ryai.240003 · Cited by 8
AI, Federated Learning, and Explainable AI for Developing Secure and Robust Healthcare 4.0 Networks
Shrivastava, K., Jumaah, A. H., Adel, A.-H., Jabbar, K. A., & Sahu, M. K. (2025) · OPJU International Technology Conference on Smart Computing for Innovation and Advancement in Industry (OTCON) · doi:10.1109/otcon65728.2025.11071020 · Cited by 3
“Securely managing and checking decentralized healthcare data using blockchain may aid federated learning [10].”
Searching for Pneumothorax in Half a Million Chest X-Ray Images
Sze-To, A., & Tizhoosh, H. R. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59137-3_40 · Cited by 3
Multi-Site Assessment of Pediatric Bone Age Using Deep Learning
Valliani, A. A.-A., Schwartz, J., Arvind, V., Taree, A., Kim, J., & Cho, S. K.-W. (2020) · ACM International Conference on Bioinformatics, Computational Biology, and Health Informatics (ACM-BCB) · doi:10.1145/3388440.3412429 · Cited by 3
Automated Method for Evaluating Neural Network’s Attention Focus
Szandała, T., & Maciejewski, H. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-77964-1_33 · Cited by 3
External COVID-19 Deep Learning Model Validation on ACR AI-LAB: It’s a Brave New World
Ardestani, A., Li, M., Chea, P., Wortman, J. R., Medina, A., Kalpathy–Cramer, J., & Wald, C. (2022) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2022.03.013 · Cited by 4
“This variability in generalization of the performance is a known issue, especially for models created based on single-institution data [16].”
BackgroundImpact of Data Quality and Target Representation on Predictions for Urban Bus Networks
Reich, T., Budka, M., & Hulbert, D. (2020) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci47803.2020.9308166 · Cited by 4
“More wellknown examples highlighting the importance of target representation come from medical image classification, where algorithms have been found to use confounding clues such as cables visible in an image to make a prediction [17].”
BackgroundAloo, R., Mutoh, A., Moriyama, K., Matsui, T., & Inuzuka, N. (2022) · Artificial Life and Robotics · doi:10.1007/s10015-022-00781-8 · Cited by 4
“Due to the sensitive nature of data sets, especially relating to medical data of patients, the availability of large data sets is a key setback [8].”
BackgroundIntegration of AI for Clinical Decision Support
Visweswaran, S., King, A. J., & Cooper, G. F. (2022) · Cognitive informatics in biomedicine and healthcare · doi:10.1007/978-3-031-09108-7_10 · Cited by 4
Artificial intelligence in oncological therapies
Adluru, S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15280-1.00014-5 · Cited by 3
Metadata
- Authors
- Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K.
- Affiliations
- California Pacific Medical Center (US)
- Verily Life Sciences LLC (United States) (US)
- Icahn School of Medicine at Mount Sinai (US)
- Corresponding author
- Oermann, Eric Karl
- ORCID
- Venue
- PLOS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-11-06
- Volume
- 15
- Issue
- 11
- Pages
- e1002683
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- PMC
- PMC6219764
- OpenAlex
- W2811374795
- Cited by
- 1,719
- References
- 34
- Citations by year
- 2026: 412 · 2025: 212 · 2024: 186 · 2023: 190 · 2022: 206 · 2021: 236 · 2020: 173 · 2019: 90 · 2018: 12
- FWCI
- 87.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Icahn School of Medicine at Mount Sinai
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- pneumonia detection, chest radiograph, convolutional neural networks, model generalization, external validation, computer-aided diagnosis, pneumonia screening, split-sample validation, radiographic findings, deep learning for medical imaging
- MeSH terms
- Deep Learning, Adult, Aged, Cross-Sectional Studies, Diagnosis, Computer-Assisted, Female, Humans, Male, Middle Aged, Pneumonia, Predictive Value of Tests, Radiographic Image Interpretation, Computer-Assisted, Radiology Information Systems, Retrospective Studies, Radiography, Thoracic, United States, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.