Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There is interest in using convolutional neural networks (CNNs) to analyze medical imaging to provide computer-aided diagnosis (CAD). Recent work has suggested that image classification CNNs may not generalize to new data as well as previously believed. We assessed how well CNNs generalized across three hospital systems for a simulated pneumonia screening task. METHODS AND FINDINGS: A cross-sectional design with multiple model training cohorts was used to evaluate model generalizability to external sites using split-sample validation. A total of 158,323 chest radiographs were drawn from three institutions: National Institutes of Health Clinical Center (NIH; 112,120 from 30,805 patients), Mount Sinai Hospital (MSH; 42,396 from 12,904 patients), and Indiana University Network for Patient Care (IU; 3,807 from 3,683 patients). These patient populations had an age mean (SD) of 46.9 years (16.6), 63.2 years (16.5), and 49.6 years (17) with a female percentage of 43.5%, 44.8%, and 57.3%, respectively. We assessed individual models using the area under the receiver operating characteristic curve (AUC) for radiographic findings consistent with pneumonia and compared performance on different test sets with DeLong's test. The prevalence of pneumonia was high enough at MSH (34.2%) relative to NIH and IU (1.2% and 1.0%) that merely sorting by hospital system achieved an AUC of 0.861 (95% CI 0.855-0.866) on the joint MSH-NIH dataset. Models trained on data from either NIH or MSH had equivalent performance on IU (P values 0.580 and 0.273, respectively) and inferior performance on data from each other relative to an internal test set (i.e., new data from within the hospital system used for training data; P values both <0.001). The highest internal performance was achieved by combining training and test data from MSH and NIH (AUC 0.931, 95% CI 0.927-0.936), but this model demonstrated significantly lower external performance at IU (AUC 0.815, 95% CI 0.745-0.885, P = 0.001). To test the effect of pooling data from sites with disparate pneumonia prevalence, we used stratified subsampling to generate MSH-NIH cohorts that only differed in disease prevalence between training data sites. When both training data sites had the same pneumonia prevalence, the model performed consistently on external IU data (P = 0.88). When a 10-fold difference in pneumonia rate was introduced between sites, internal test performance improved compared to the balanced model (10× MSH risk P < 0.001; 10× NIH P = 0.002), but this outperformance failed to generalize to IU (MSH 10× P < 0.001; NIH 10× P = 0.027). CNNs were able to directly detect hospital system of a radiograph for 99.95% NIH (22,050/22,062) and 99.98% MSH (8,386/8,388) radiographs. The primary limitation of our approach and the available public data is that we cannot fully assess what other factors might be contributing to hospital system-specific biases. CONCLUSION: Pneumonia-screening CNNs achieved better internal than external performance in 3 out of 5 natural comparisons. When models were trained on pooled data from sites with different pneumonia prevalence, they performed better on new pooled data from these sites but not on external data. CNNs robustly identified hospital system and department within a hospital, which can have large differences in disease burden and may confound predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, the system was able to distinguish only which machine was used for imaging and not the risk of the patients.”
From Explainability for artificial intelligence in healthcare: a multidisciplinary perspective (2020) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In a study training AI to diagnose pneumonia from chest X-rays, the performance on unseen data from the institution where the training data were collected was significantly higher than its performance on data collected from external hospitals [72].”
From Fairness of artificial intelligence in healthcare: review and recommendations (2024) · cites this paper as [72]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Shortcut learning, in which a model latches onto a spurious correlate (eg, the scanner used at a particular site, a hospital-specific text template) rather than the clinical signal of interest, has been repeatedly documented in medical AI and can be difficult to detect without deliberate probing.62”
From Artificial Intelligence in Oncology: Practical Applications Across Clinical Care, Scholarship, and Translation. (2026) · cites this paper as [62]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This study hypothesized that multicenter training could enhance the generalizability of AI models, which has previously been demonstrated in other medical imaging scenarios25–27.”
From Federated deep learning for detecting COVID-19 lung abnormalities in CT: a privacy-preserving multinational validation study (2021) · cites this paper as [26]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, variations in data collection and processing can degrade model accuracy on data from new hospital deployments (Zech et al., 2018; AlBadawy et al., 2018).”
From WILDS: A Benchmark of in-the-Wild Distribution Shifts (2020) · cites this paper as Zech et al., 2018
12 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 2×
“Many different CNN architectures have been proposed, including ResNet-50 and DenseNet-121 used in this paper, and improving the performance of these models is an active area of research [14,15].”
MethodLeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDensely Connected Convolutional Networks
Huang, G., Liu, Z., van der Maaten, L., & Weinberger, K. Q. (2016) · arXiv · doi:10.48550/arxiv.1608.06993 · Cited by 48,960
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
(2017) · Cited by 11,625
Cited by
Items 801–900 of 1,005
Noninvasive Glucose Monitoring: In God We Trust—All Others Bring Data
Klonoff, D. C., Nguyen, K. T., Xu, N. Y., & Arnold, M. A. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211046326 · Cited by 7
Preserving the Fairness Guarantees of Classifiers in Changing Environments: A Survey
Barrainkua, A., Gordaliza, P., Lozano, J. A., & Quadrianto, N. (2025) · ACM Computing Surveys · doi:10.1145/3637438 · Cited by 22
“For instance, health-care applications often face distribution shift scenarios, and for such critical settings, it is essential to provide robust fairness guarantees [17, 18, 35, 95, 116, 123].”
Lv, M., Chen, F., Li, Q., Xue, M., & Wang, J. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1670843 · Cited by 6
Ardıç, N., & Dinç, R. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1785381 · Cited by 9
Using routinely collected data for research purposes: challenges and mitigation strategies
Hoffmann, S., Morris, T. P., Herrmann, M., Heinze, G., Wynants, L., CALSTER, B. V., Bischl, B., Schmid, M., Shaw, P. A., Mathes, T., et al. (2026) · BMJ · doi:10.1136/bmj-2025-087812 · Cited by 12
On the Importance of Domain Awareness in Classifier Interpretations in Medical Imaging
Major, D., Lenis, D., Wimmer, M., Berg, A., Neubauer, T., & Bühler, K. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3247659 · Cited by 9
“That is, we can’t judge if numerically accurate predictions are based on meaningful insights or spurious correlations like image markers [9], [10].”
BackgroundPathni, R. K. (2023) · Journal of Healthcare Management Standards · doi:10.4018/jhms.329234 · Cited by 10
“An AI tool developed at Mount Sinai Hospital performed very well in identifying high-risk patients based on chest x-rays.”
Nakayama, L. F., Ribeiro, L. Z., Malerbi, F. K., & Regatieri, C. V. (2025) · International Journal of Retina and Vitreous · doi:10.1186/s40942-024-00596-8 · Cited by 13
“Furthermore, AI algorithms developed for radiology may overlook disease markers that manifest differently in Latin American patients, reinforcing the importance of using local data to ensure these systems work equitably across diverse populations [13].”
Pahde, F., Wiegand, T., Lapuschkin, S., & Samek, W. (2025) · Machine Learning · doi:10.1007/s10994-025-06834-w · Cited by 18
“Similarly, DNNs trained to detect pneumonia from radiographs have been known to predict the hospital system used for the scan, as the prevalence varied across hospitals in the study [79].”
Sun, M. G., Saha, S., Shah, S. A., Luz, S. F., Nair, H., & Saha, S. K. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-044461 · Cited by 6
Nayor, M. G., Shen, L., Hunninghake, G. M., Kochunov, P., Barr, R. G., Bluemke, D. A., Broeckel, U., Caravan, P. D., Cheng, S. C., de Vries, P. S., et al. (2021) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.121.012943 · Cited by 5
Sinaga, R. M., Maydiantoro, A., Ochayi, O. A., Yulianti, D., Arif, S., Basri, M., Bolado, J. R. T., & Suroto, S. (2022) · Journal of Educational and Social Research · doi:10.36941/jesr-2022-0026 · Cited by 23
Cheng, X.-Y., Wen, H., Hao, Y., Li, H., Wu, X., Cao, Q., & Jia-bao, L. (2022) · Technology in Cancer Research & Treatment · doi:10.1177/15330338221085375 · Cited by 7
Detecting Different Thoracic Disease Using CNN-Model
Tiwari, R., Verma, M., & Sar, S. K. (2022) · International Conference for Advancement in Technology (ICONAT) · doi:10.1109/iconat53423.2022.9725940 · Cited by 6
Gautam, S., Höhne, M., Hansen, S., Jenssen, R., & Kampffmeyer, M. (2022) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi52829.2022.9761651 · Cited by 13
Explainable AI and Its Applications in Healthcare
Sarkar, A. (2022) · Intelligent systems reference library · doi:10.1007/978-3-031-12807-3_6 · Cited by 6
Socha, M., Prażuch, W., Suwalska, A., Foszner, P., Tobiasz, J., Jaroszewicz, J., Gruszczyńska, K., Sliwinska, M., Nowak, M., Giżycka, B., et al. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107684 · Cited by 8
“They can indicate the type of scanning protocol, the patient’s osition during the procedure or the marking style of a particular acility [10,18,24] .”
Dimensionality Reduction for Improving Out-of-Distribution Detection in Medical Image Segmentation
Woodland, M. E., Patel, N., Taie, M. A., Yung, J. P., Netherton, T., Patel, A., & Brock, K. K. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-44336-7_15 · Cited by 14
“Deep learning (DL) models struggle to generalize to information that was not present while the model was being trained [1].”
BackgroundUnderstanding Bias in Artificial Intelligence: A Practice Perspective
Davis, M. A., Wu, O., Ikuta, I., Jordan, J. E., Johnson, M. H., & Quigley, E. P. (2023) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8070 · Cited by 6
RoMIA: a framework for creating Robust Medical Imaging AI models for chest radiographs
Anand, A., Krithivasan, S., & Roy, K. (2024) · Frontiers in Radiology · doi:10.3389/fradi.2023.1274273 · Cited by 9
Rajaraman, S., Zamzmi, G., Yang, F., Liang, Z., Xue, Z., & Antani, S. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000286 · Cited by 9
“Therefore, developing reliable and generalizable models mandates both internal and external/out-of-distribution testing [19].”
BackgroundEissa, T., Huber, M., Obermayer-Pietsch, B. M., Linkohr, B., Peters, A., Fleischmann, F., & Žigman, M. (2024) · PNAS Nexus · doi:10.1093/pnasnexus/pgae449 · Cited by 9
“Consequently, when applying a developed machine learning (ML) model to independently collected and experimentally measured samples, the model may fail to achieve the expected efficacy (8, 10 – 15).”
MethodAn Acquisition Parameter Study for Machine-Learning-Enabled Electron Backscatter Diffraction
Kaufmann, K., & Vecchio, K. S. (2021) · Microscopy and Microanalysis · doi:10.1017/s1431927621000556 · Cited by 9
“…confident that the model has truly learned relevant information, is robust to new conditions, and has not found an unscien-tific approach to solving the problem [such as learning the presence of a ruler means a lesion is more likely cancerous (Esteva et al., 2017)] (Zech et al., 2018; Riley, 2019).”
BackgroundQu, C., Zou, Y., Dai, Q., Ma, Y., He, J., Liu, Q., Kuang, W., Jia, Z., Chen, T., & Gong, Q. (2021) · Psychoradiology · doi:10.1093/psyrad/kkab017 · Cited by 6
“…many studies have suggested that although internal validation can effectively evaluate the technical performance of deep learning models, it may also lead to insufficient generalization performance in real-world, high-volume clinical environments (Zech et al. , 2018; Salehinejad et al. , 2021).”
BackgroundA novel abnormality annotation database for COVID-19 affected frontal lung X-rays
Mittal, S., Venugopal, V. K., Agarwal, V., Malhotra, M., Chatha, J. S., Kapur, S., Gupta, A., Batra, V., Majumdar, P., Malhotra, A., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0271931 · Cited by 8
“In this direction, multiple studies have been performed which analyze the generalization abilities of deep learning models and how the models exploit confounding information [47].”
BackgroundMcManigle, J. E., Bartz, R. R., & Carin, L. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176334 · Cited by 7
“Just as models trained to differentiate photographs of husky dogs from those of wolves famously relied on background information in the image [17], models trained on radiographs – especially multi-site datasets – use annotations and other image features [18] to deduce the hospital, ward, and even individual imaging ma…”
MethodFactors determining generalization in deep learning models for scoring COVID-CT images
Horry, M. J., Chakraborty, S., Pradhan, B., Fallahpoor, M., Chegeni, H., & Paul, M. (2021) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2021456 · Cited by 14
Schuhmacher, D., Gerwert, K. B., & Mosig, A. (2020) · medRxiv · doi:10.1101/2020.02.27.20028845 · Cited by 6
Lee, D., Cheng, Z., Mao, C., & Manzoor, E. (2018) · SSRN Electronic Journal · doi:10.2139/ssrn.3304756 · Cited by 6
Robust Semantic Interpretability: Revisiting Concept Activation VectorsPreprint
Pfau, J., Young, A. T., Wei, J., Wei, M. L., & Keiser, M. J. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2104.02768 · Cited by 22
Detecting and Adapting to Irregular Distribution Shifts in Bayesian Online LearningPreprint
Li, A., Boyd, A., Smyth, P., & Mandt, S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2012.08101 · Cited by 22
“Deployed machine learning systems are often faced with the problem of distribution shift, where the new data that the model processes is systematically different from the data the system was trained on [Zech et al., 2018, Ovadia et al., 2019].”
MethodThe Importance of External Validation for Neural Network Models
Goto, S., & Ozawa, H. (2023) · JACC Advances · doi:10.1016/j.jacadv.2023.100610 · Cited by 7
Bajunaid, R., Niu, C., Hambly, C., Liu, Z., Yamada, Y., Alemán-Mateo, H., Anderson, L. J., Arab, L., Baddou, I., Bandini, L. G., et al. (2025) · Nature Food · doi:10.1038/s43016-025-01175-2 · Cited by 7
Fragemann, J., Ardizzone, L., Egger, J., Kleesiek, J., & Workshop, M. (2022) · doi:10.36227/techrxiv.19364897.v1 · Cited by 6
Watson, M., Chambers, P., Steventon, L., King, J. H., Ercia, A., Shaw, H. M., & Moubayed, N. A. (2024) · BMJ Oncology · doi:10.1136/bmjonc-2024-000430 · Cited by 7
“While many of these proposed analyses would be straightforward to implement, recent research showing the prevalence of biased ML models 18 47 48 highlights their underutilisation.”
A sustainable neuromorphic framework for disease diagnosis using digital medical imaging
Gulakala, R., & Stoffel, M. (2024) · Computer Methods and Programs in Biomedicine Update · doi:10.1016/j.cmpbup.2024.100171 · Cited by 5
From pixels to patients: the evolution and future of deep learning in cancer diagnostics
Yang, Y., Shen, H., Chen, K., & Li, X. (2024) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2024.11.009 · Cited by 7
Mun, J., Jo, H.-G., & Park, C. S. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115359 · Cited by 7
Shen, J., Cheng, N., Xu, W., Wang, H., Quan, W., & Shen, X. (2025) · IEEE Transactions on Cognitive Communications and Networking · doi:10.1109/tccn.2025.3561292 · Cited by 6
“A study by Zech et al. [5] demonstrated this variation when examining chest X-rays across three hospitals, where pneumonia prevalence ranged from 1.2% to 8.4% among 158,323 patients, reflecting the distinct demographic populations served.”
InfluentialKashyap, S., Shukla, A. K., Naim, I., & Pal, S. (2025) · Biomedical Materials & Devices · doi:10.1007/s44174-025-00335-z · Cited by 6
Hsu, D., Persitz, J., Noori, A., Zhang, H., Mashouri, P., Shah, R., Chan, A. H. W., Madani, A., & Paul, R. (2025) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2025.04.015 · Cited by 6
From Data to Diagnosis: Rethinking Clinical Decision Support With Explainable AI
Ahmad, N., Julaihi, A. A., & Rajalingam, P. (2025) · Computer · doi:10.1109/mc.2025.3572653 · Cited by 5
Kleinig, O., Hains, L. R., Murugappa, A., Gluck, S., Marks, J., Gilbert, T., & Bacchi, S. (2025) · Internal Medicine Journal · doi:10.1111/imj.70150 · Cited by 5
Makrygiannakis, M. A., & Kaklamanos, E. G. (2025) · European Journal of Orthodontics · doi:10.1093/ejo/cjaf085 · Cited by 12
“AI models often exhibit lower accuracy when used outside their original training conditions, a phenomenon known as domain shift [37, 38].”
Patient safety in AI-powered diagnostic pathology
Rugge, M., Fraschini, M., Orvieto, E., Didaci, L., Sandonà, L., D’Amuri, A., Saba, L., & Faa, G. (2025) · Journal of Clinical Pathology · doi:10.1136/jcp-2025-210231 · Cited by 6
Artificial superintelligence alignment in healthcare
Ueda, D., Walston, S. L., Kurokawa, R., Saida, T., Honda, M., Iima, M., Watabe, T., Yanagawa, M., Nishioka, K., Sofue, K., et al. (2025) · Japanese Journal of Radiology · doi:10.1007/s11604-025-01907-1 · Cited by 10
“A pivotal study revealed this vulnerability in stark detail [ 35 ].”
InfluentialKaur, A. P., Cherukuri, S. P., Handral, M. S., Kukunoor, H. R., Kc, R., Godugu, S., Lee, J., Yerrapragada, G., Elangovan, P., Shariff, M. N., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14238500 · Cited by 8
“Furthermore, supervised models tend to underperform when applied to new geographic regions or when using different data acquisition devices, due to biases in the original training datasets [135].”
Vyas, R., & Pandey, R. K. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.109272 · Cited by 8
Foundation models in radiology: a primer for pediatric radiologists
Gupta, A., Fanni, S. C., Veiga-Canuto, D., & Guarnera, A. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06544-y · Cited by 7
“…narrowly defined task and a single training distribution; while they can generalize within that distribution, their performance may degrade under domain shifts (e.g., changes in acquisition protocols, case-mix, or label definitions), typically requiring substantial retraining or recalibration [18].”
Artificial Intelligence for Image Reconstruction in Children: Counterpoint—Proceed With Caution
Chung, T., & Muthupillai, R. (2024) · American Journal of Roentgenology · doi:10.2214/ajr.23.30746 · Cited by 5
Obwegeser, D., Timofte, R., Mayer, C., Bornstein, M. M., Schätzle, M. A., & Patcas, R. (2024) · Orthodontics and Craniofacial Research · doi:10.1111/ocr.12820 · Cited by 6
“Given the evidence that CNNs perform better when trained on pooled data from different sources, 37 caution should be applied prior considering unrestrained deployment of the presented systems without first assessing its generalizability.”
Multi-Source-Free Domain Adaptation via Uncertainty-Aware Adaptive Distillation
Song, Y., Fan, J., Liu, D., & Cai, W. (2024) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi56570.2024.10635548 · Cited by 5
“Since the distinctions of the data from multiple centres are large, the models trained on datasets derived from single or multiple healthcare institutions have not demonstrated a consistent ability to generalise their applicability to external sites [16].”
Allen, K., Yawson, A. K., Haggenmüller, S., Kather, J. N., & Brinker, T. J. (2024) · ESMO Real World Data and Digital Oncology · doi:10.1016/j.esmorw.2024.100077 · Cited by 10
“12 For instance, AIDTs typically show lower accuracy when confronted with real-world data 13-16 due to several factors, including distribution shifts, 17 performance based on shortcuts rather than signal, 18,19 and model biases by factors such as ethnicity 20-22 and gender.”
Stress classification with in-ear heartbeat sounds
Benesch, D., Villatte, B., Vinet, A., Hébert, S., Voix, J., & Bouserhal, R. E. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109555 · Cited by 6
Neto, L. A. A., Freire, A. M., & Silva, L. P. (2025) · Biomedicines · doi:10.3390/biomedicines13010208 · Cited by 5
Artificial intelligence in spinal imaging - a narrative review
Ibrahim, M., Milliron, E. M., & Yu, E. (2025) · Artificial Intelligence Surgery · doi:10.20517/ais.2024.41 · Cited by 6
Contreras, K., Gutierrez-Rengifo, J., Casanova-Carvajal, Ó., Álvarez, A. L., Vélez-Varela, P. E., & Bojorge, A. L. U. (2025) · Applied Sciences · doi:10.3390/app15116274 · Cited by 6
Su, C., Miao, K., Zhang, L., Yu, X., Guo, Z., Li, D., Xu, M., Zhang, Q., & Dong, X. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01566-8 · Cited by 9
A Counterfactual Account of Algorithmic Robustness
Bjerring, J. C., Busch, J., & Munch, L. A. (2025) · Minds and Machines · doi:10.1007/s11023-025-09734-z · Cited by 9
“For instance, as reported in Zech et al. (2018), a machine learning model used to diagnose pneumonia from X-rays was found to achieve its predictive performance by exploiting confounding features—such as hooks at the edges of the images—rather than focusing on the relevant medical indicators.”
Yoon, H., Kim, B. R., Kim, H. Y., Park, D. K., Kim, H. S., Cho, H.-Y., Lee, H.-C., & Lee, H. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01949-9 · Cited by 12
“Thisaddressesamajorlimitationofpriorstudies,which frequentlyreportedsigni fi cant performance declines during external validation 10,24 – 27 .”
Chang, K., Singh, P., Vepakomma, P., Poirot, M. G., Raskar, R., Rubin, D. L., & Kalpathy–Cramer, J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-821259-2.00006-5 · Cited by 6
Artificial Intelligence in Ophthalmology: Promises, Hazards and Challenges
Grzybowski, A. E. (2021) · Springer eBooks · doi:10.1007/978-3-030-78601-4_1 · Cited by 9
A deep-learning toolkit for visualization and interpretation of segmented medical images
Ghosal, S., & Shah, P. P. (2021) · Cell Reports Methods · doi:10.1016/j.crmeth.2021.100107 · Cited by 7
“As a result, DL models memorize rather than learn and perform poorly when tested with out-of-distribution (OoD) but related medical tasks [24].”
BackgroundDeep-COVID: Detection and Analysis of COVID-19 Outcomes Using Deep Learning
Khalil, M. I., Rehman, S. U., Alhajlah, M., Mahmood, A., Karamat, T., Haneef, M., & Alhajlah, A. (2022) · Electronics · doi:10.3390/electronics11223836 · Cited by 6
Thoughts on Non-IID Data Impact in Healthcare with Federated Learning Medical Blockchain
Shae, Z., Chen, K.-Y., Chang, C.-Y., Tsai, Y., Chou, C., Baskett, W. I., Shyu, C., & Tsai, J. J. P. (2022) · IEEE International Conference on Cognitive Machine Intelligence (CogMI) · doi:10.1109/cogmi56440.2022.00013 · Cited by 7
“Zech et al. [13] showed that deep learning models trained on data from a single institution can have high accuracy when evaluated on the same clinical institution's data.”
BackgroundDeep learning approach for disease detection in lumbosacral spine radiographs using ConvNet
Vieira, P. D. A., Vogado, L. H. S., Lopes, L. A., Ricardo, R., Neto, P. D. A. D. S., Mathew, M. J., Magalhães, D. M. V., & Silva, R. (2023) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2023.2245922 · Cited by 5
“According to (Zech et al. 2018) and (Geirhos et al. 2020), metallic hospital tokens and radiograph metadata can bias the learning of CNNs.”
BackgroundConsiderations in the assessment of machine learning algorithm performance for medical imaging
Gossmann, A., Sahiner, B., Samala, R. K., Wen, S., Cha, K. H., & Petrick, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-32-385124-4.00029-5 · Cited by 5
Cao, N., & Saukh, O. (2023) · IEEE International Conference on Parallel and Distributed Systems (ICPADS) · doi:10.1109/icpads60453.2023.00084 · Cited by 8
Liu, Z., Tieu, A., Patel, N., Soultanidis, G., Deyer, L., Wang, Y., Huver, S. D., Zhou, A., Mei, Y., Fayad, Z. A., et al. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-73290-4_10 · Cited by 18
“…traditional deep learning models are specifically trained for designated applications, such as the classification of interstitial lung disease [2] or COVID-19 [3], and consistently underperform when repurposed for other tasks [4], foundation models offer more generalized and adaptable capabilities.”
Turing’s Test vs the Moral Turing Test
Proudfoot, D. (2024) · Philosophy & Technology · doi:10.1007/s13347-024-00825-w · Cited by 7
“For example, a medical image model training on lung x-rays learned to correlate a pneumonia diagnosis, not with anatomical features, but with hospital information embedded in the images (Zech et al., 2018).”
Song, F., Li, Y., Jiang, M., Li, K., Zhang, J., Zhang, Y., & Pang, Z. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3531419 · Cited by 5
“Centralized Learning (CL) attempts to address this limitation [9], [10].”
Serin, O., Akbasli, I. T., Cetin, S. B., Köseoğlu, B., Deveci, A. F., Ugur, M. Z., & Özsürekçi, Y. (2025) · JMIRx Med · doi:10.2196/57719 · Cited by 5
“It has been seen that the vast majority of data science studies on pneumonia aims to provide diagnostic support to the physician by processing radiological images [18].”
Fair Deep Learning Prediction for Healthcare Applications with Confounder Filtering.
Wu, Z., Wang, H., Cao, M., Chen, Y., & Xing, E. P. (2018) · Cited by 6
Batch-wise Regularization of Deep Neural Networks for Interpretability
Burkart, N., Faller, P. M., Peinsipp-Byma, E., & Huber, M. F. (2020) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi49285.2020.9235209 · Cited by 8
Checking Robustness of Representations Learned by Deep Neural Networks
Szyc, K., Walkowiak, T., & Maciejewski, H. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-86517-7_25 · Cited by 9
“[31] and [14] showed that deep models trained in the context of medical diagnostic tasks involving chest X-rays usually generalize poorly to new data or data from other sources (e.g., hospitals).”
BackgroundNedios, S., Iliodromitis, K. E., Kowalewski, C., Bollmann, A., Hindricks, G., Dagres, N., & Bogossian, H. (2022) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-022-00837-z · Cited by 6
A Privacy-Preserving Walk in the Latent Space of Generative Models for Medical Applications
Pennisi, M., Salanitri, F. P., Bellitto, G., Palazzo, S., Bağcı, U., & Spampinato, C. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-43898-1_41 · Cited by 6
Mark My Words: Dangers of Watermarked Images in ImageNet
Bykov, K., Müller, K., & Höhne, M. (2024) · Communications in computer and information science · doi:10.1007/978-3-031-50396-2_24 · Cited by 11
Wiratman, A. B., & Wella, W. (2024) · JOIV International Journal on Informatics Visualization · doi:10.62527/joiv.8.1.1905 · Cited by 5
Why Radiologists Have Nothing to Fear From Deep Learning
Bratt, A. K. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.02.037 · Cited by 5
Detecting and ranking pornographic content in videos
Borg, M. G., Tabone, A., Bonnici, A., Cristina, S., Farrugia, R. A., & Camilleri, K. P. (2022) · Forensic Science International Digital Investigation · doi:10.1016/j.fsidi.2022.301436 · Cited by 13
Convolutional Neural Network with Attention Modules for Pneumonia Detection
Ali, G., Shahin, A. H., El-Hadidi, M. S., & Elattar, M. (2020) · International Conference on Innovation and Intelligence for Informatics, Computing, and Technologies (3ICT) · doi:10.1109/3ict51146.2020.9311985 · Cited by 4
“In plain words, for the results to be comparable, all methods should be subjected to the exact same data, with the exact same data split [4].”
MethodMitigating the Effect of Dataset Bias on Training Deep Models for Chest X-rays.Preprint
Zhang, Y., Wu, H., Liu, H., Li, T., & Wang, M. D. (2019) · arXiv (Cornell University) · Cited by 6
Validation of a deep learning mammography model in a population with low screening ratesPreprint
Wu, K., Wu, E., Wu, Y., Tan, H., Sorensen, G., Wang, M., & Lotter, B. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1911.00364 · Cited by 6
“I V ] 1 N ov 2019 sensitivity of deep learning models to input statistics [12, 13].”
I-SPEC: An End-to-End Framework for Learning Transportable, Shift-Stable ModelsPreprint
Subbaswamy, A., & Saria, S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2002.08948 · Cited by 12
“Consider the study of Zech et al. (2018), who trained a model to diagnose pneumonia from chest X-rays using data from one hospital.”
Was there COVID-19 back in 2012? Challenge for AI in Diagnosis with Similar IndicationsPreprint
Banerjee, I., Sinha, P., Purkayastha, S., Mashhaditafreshi, N., Tariq, A., Jeong, J., Trivedi, H., & Gichoya, J. W. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2006.13262 · Cited by 8
“, image compression[11]), and overlooked pathology[12].”
Addressing Fairness, Bias and Class Imbalance in Machine Learning: the FBI-lossPreprint
Ferrari, E., & Bacciu, D. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2105.06345 · Cited by 12
Mair, D., Witz, G., do Prado, A. H., Garefalakis, P., & Schlunegger, F. (2023) · EarthArXiv (California Digital Library) · doi:10.31223/x51h31 · Cited by 5
Hurt, B., Rubel, M., Masutani, E., Jacobs, K. E., Hahn, L. D., Horowitz, M., Kligerman, S. J., & Hsiao, A. (2022) · PubMed · doi:10.1097/rti.0000000000000618 · Cited by 4
“% AP 45% 73% 89% % Men 56% 52% 56% Mean age (range) 47 (1-92) 57 (18-98) 55 (19-100)”
Gaze-guided vision transformer for chest X-ray image classification
Chen, Z., Liu, Z., & Song, Y. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108298 · Cited by 6
Elbahi, M. K., Muhammed, A., Mohamednour, M. F. A., & Mukhtar, F. S. (2025) · Cureus · doi:10.7759/cureus.93124 · Cited by 4
“The Stanford MURA dataset (2018) includes over 40,000 upper-extremity radiographs collected from a single U.S. academic hospital [17].”
InfluentialPesapane, F., & Sardanelli, F. (2025) · Insights into Imaging · doi:10.1186/s13244-025-02171-7 · Cited by 7
“Marked variation under such shifts could be a signal that the model is relying on shortcuts rather than clinically valid cues [27, 30, 32].”
Pathak, A. K., Gupta, M., & Jain, G. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2025.1692454 · Cited by 9
Moshe, Y. H., Teicher, M., & Artzi, M. (2026) · Technology in Cancer Research & Treatment · doi:10.1177/15330338251405180 · Cited by 4
Qiqi, K., & Ban, Y. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1745519 · Cited by 7
Ramadan, R. Α., Madi, N. K. M., Fageeri, S. O., Yousif, K. A., Al-Daweri, M. S., & Rajhi, W. K. H. A. (2026) · Neurocomputing · doi:10.1016/j.neucom.2026.132919 · Cited by 5
Clinical AI in Radiology: Foundations, Trends, Applications, and Emerging Directions
Hartsock, I., Koutsoubis, N., Ahmed, S., Parker, N. H., Schabath, M. B., Araujo, C. R., Qayyum, A., Lam, C. A., Gatenby, R. A., & Rasool, G. (2026) · Cancers · doi:10.3390/cancers18060942 · Cited by 12
Learning to See with Less: A Survey on Computer Vision with Limited and Imperfect Data
Fawakherji, M., Alaoui, S., & Turjya, S. M. (2026) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-026-10558-y · Cited by 11
Haupt, M., & Maurer, M. H. (2026) · European Journal of Radiology Artificial Intelligence · doi:10.1016/j.ejrai.2026.100098 · Cited by 9
Zhalechian, M., Saghafian, S., & Robles, O. (2026) · Management Science · doi:10.1287/mnsc.2024.06477 · Cited by 7
Metadata
- Authors
- Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K.
- Affiliations
- California Pacific Medical Center (US)
- Verily Life Sciences LLC (United States) (US)
- Icahn School of Medicine at Mount Sinai (US)
- Corresponding author
- Oermann, Eric Karl
- ORCID
- Venue
- PLOS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-11-06
- Volume
- 15
- Issue
- 11
- Pages
- e1002683
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- PMC
- PMC6219764
- OpenAlex
- W2811374795
- Cited by
- 1,719
- References
- 34
- Citations by year
- 2026: 412 · 2025: 212 · 2024: 186 · 2023: 190 · 2022: 206 · 2021: 236 · 2020: 173 · 2019: 90 · 2018: 12
- FWCI
- 87.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Icahn School of Medicine at Mount Sinai
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- pneumonia detection, chest radiograph, convolutional neural networks, model generalization, external validation, computer-aided diagnosis, pneumonia screening, split-sample validation, radiographic findings, deep learning for medical imaging
- MeSH terms
- Deep Learning, Adult, Aged, Cross-Sectional Studies, Diagnosis, Computer-Assisted, Female, Humans, Male, Middle Aged, Pneumonia, Predictive Value of Tests, Radiographic Image Interpretation, Computer-Assisted, Radiology Information Systems, Retrospective Studies, Radiography, Thoracic, United States, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.