Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There is interest in using convolutional neural networks (CNNs) to analyze medical imaging to provide computer-aided diagnosis (CAD). Recent work has suggested that image classification CNNs may not generalize to new data as well as previously believed. We assessed how well CNNs generalized across three hospital systems for a simulated pneumonia screening task. METHODS AND FINDINGS: A cross-sectional design with multiple model training cohorts was used to evaluate model generalizability to external sites using split-sample validation. A total of 158,323 chest radiographs were drawn from three institutions: National Institutes of Health Clinical Center (NIH; 112,120 from 30,805 patients), Mount Sinai Hospital (MSH; 42,396 from 12,904 patients), and Indiana University Network for Patient Care (IU; 3,807 from 3,683 patients). These patient populations had an age mean (SD) of 46.9 years (16.6), 63.2 years (16.5), and 49.6 years (17) with a female percentage of 43.5%, 44.8%, and 57.3%, respectively. We assessed individual models using the area under the receiver operating characteristic curve (AUC) for radiographic findings consistent with pneumonia and compared performance on different test sets with DeLong's test. The prevalence of pneumonia was high enough at MSH (34.2%) relative to NIH and IU (1.2% and 1.0%) that merely sorting by hospital system achieved an AUC of 0.861 (95% CI 0.855-0.866) on the joint MSH-NIH dataset. Models trained on data from either NIH or MSH had equivalent performance on IU (P values 0.580 and 0.273, respectively) and inferior performance on data from each other relative to an internal test set (i.e., new data from within the hospital system used for training data; P values both <0.001). The highest internal performance was achieved by combining training and test data from MSH and NIH (AUC 0.931, 95% CI 0.927-0.936), but this model demonstrated significantly lower external performance at IU (AUC 0.815, 95% CI 0.745-0.885, P = 0.001). To test the effect of pooling data from sites with disparate pneumonia prevalence, we used stratified subsampling to generate MSH-NIH cohorts that only differed in disease prevalence between training data sites. When both training data sites had the same pneumonia prevalence, the model performed consistently on external IU data (P = 0.88). When a 10-fold difference in pneumonia rate was introduced between sites, internal test performance improved compared to the balanced model (10× MSH risk P < 0.001; 10× NIH P = 0.002), but this outperformance failed to generalize to IU (MSH 10× P < 0.001; NIH 10× P = 0.027). CNNs were able to directly detect hospital system of a radiograph for 99.95% NIH (22,050/22,062) and 99.98% MSH (8,386/8,388) radiographs. The primary limitation of our approach and the available public data is that we cannot fully assess what other factors might be contributing to hospital system-specific biases. CONCLUSION: Pneumonia-screening CNNs achieved better internal than external performance in 3 out of 5 natural comparisons. When models were trained on pooled data from sites with different pneumonia prevalence, they performed better on new pooled data from these sites but not on external data. CNNs robustly identified hospital system and department within a hospital, which can have large differences in disease burden and may confound predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, the system was able to distinguish only which machine was used for imaging and not the risk of the patients.”
From Explainability for artificial intelligence in healthcare: a multidisciplinary perspective (2020) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In a study training AI to diagnose pneumonia from chest X-rays, the performance on unseen data from the institution where the training data were collected was significantly higher than its performance on data collected from external hospitals [72].”
From Fairness of artificial intelligence in healthcare: review and recommendations (2024) · cites this paper as [72]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Shortcut learning, in which a model latches onto a spurious correlate (eg, the scanner used at a particular site, a hospital-specific text template) rather than the clinical signal of interest, has been repeatedly documented in medical AI and can be difficult to detect without deliberate probing.62”
From Artificial Intelligence in Oncology: Practical Applications Across Clinical Care, Scholarship, and Translation. (2026) · cites this paper as [62]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This study hypothesized that multicenter training could enhance the generalizability of AI models, which has previously been demonstrated in other medical imaging scenarios25–27.”
From Federated deep learning for detecting COVID-19 lung abnormalities in CT: a privacy-preserving multinational validation study (2021) · cites this paper as [26]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, variations in data collection and processing can degrade model accuracy on data from new hospital deployments (Zech et al., 2018; AlBadawy et al., 2018).”
From WILDS: A Benchmark of in-the-Wild Distribution Shifts (2020) · cites this paper as Zech et al., 2018
12 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 2×
“Many different CNN architectures have been proposed, including ResNet-50 and DenseNet-121 used in this paper, and improving the performance of these models is an active area of research [14,15].”
MethodLeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDensely Connected Convolutional Networks
Huang, G., Liu, Z., van der Maaten, L., & Weinberger, K. Q. (2016) · arXiv · doi:10.48550/arxiv.1608.06993 · Cited by 48,960
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
(2017) · Cited by 11,625
Cited by
Items 701–800 of 1,005
Li, M., Chang, K., Mei, X., Bernheim, A., Chung, M., Steinberger, S., Kalpathy–Cramer, J., & Little, B. P. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.21.26717 · Cited by 13
Shetty, S., Ananthanarayana, V. S., & Mahale, A. R. (2022) · Mathematics · doi:10.3390/math10193646 · Cited by 10
“1283 million parameters) on the Open-I dataset for pulmonary disease classification [24,34,36].”
BackgroundMethodInfluentialSharafutdinov, K., Bhat, J. S., Fritsch, S. J., Nikulina, K., E. Samadi, M., Polzin, R., Mayer, H., Marx, G., Bickenbach, J., & Schuppert, A. (2022) · Frontiers in Big Data · doi:10.3389/fdata.2022.603429 · Cited by 10
“ML models perform worse in external cohorts due to several reasons such as different protocols, confounding variables, or heterogeneous populations (Cabitza et al., 2017; Zech et al., 2018; Martensson et al., 2020; Goncalves et al., 2021).”
BackgroundSakowski, E. G., Uritskiy, G., Cooper, R., Gomes, M. L., McLaren, M. R., Meisel, J. S., Mickol, R. L., Mintz, C. D., Mongodin, E. F., Pop, M., et al. (2019) · mSystems · doi:10.1128/msystems.00392-19 · Cited by 13
Object detection based approach for Automatic detection of Pneumonia
Nayyar, A., Jain, R., & Upadhyay, Y. (2020) · International Conference on Artificial Intelligence, Big Data, Computing and Data Communication Systems (icABCD) · doi:10.1109/icabcd49160.2020.9183876 · Cited by 12
Wang, H., Wu, Z., & Xing, E. P. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/442442 · Cited by 11
Global Saliency: Aggregating Saliency Maps to Assess Dataset Artefact BiasPreprint
Pfau, J., Young, A. T., Wei, M. L., & Keiser, M. J. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.07604 · Cited by 22
“However, these models are often not robust, learning non-generalizable patterns and confounding visual artefacts with diseased tissue [2], [16].”
Structured dataset documentation: a datasheet for CheXpertPreprint
Garbin, C., Rajpurkar, P., Irvin, J., Lungren, M. P., & Marques, O. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2105.03020 · Cited by 31
“[11] [12] [13] There are indications in the literature that the sex and age of patients may affect the performance of models [14] [15].”
BackgroundEditorial: Interpretable and explainable machine learning models in oncology
Hrinivich, W. T., Wang, T., & Wang, C. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1184428 · Cited by 16
Diagnosing and remediating harmful data shifts for the responsible deployment of clinical AI modelsPreprint
Subasri, V., Krishnan, A., Dhalla, A., Pandya, D., Malkin, D. M., Razak, F. A., Verma, A. A., Goldenberg, A., & Dolatabadi, E. (2023) · medRxiv · doi:10.1101/2023.03.26.23286718 · Cited by 17
Dealing with expert bias in collective decision-making
Abels, A., Lenaerts, T., Trianni, V., & Nowé, A. (2023) · Artificial Intelligence · doi:10.1016/j.artint.2023.103921 · Cited by 16
A Machine Learning Model Selection considering Tradeoffs between Accuracy and Interpretability
Nazir, Z., Kaldykhanov, D., Tolep, K.-K., & Park, J.-G. (2021) · doi:10.1109/icitee53064.2021.9611872 · Cited by 9
Measuring trustworthiness is crucial for medical AI tools
Kundu, S. (2023) · Nature Human Behaviour · doi:10.1038/s41562-023-01711-9 · Cited by 11
Cross-site prognosis prediction for nasopharyngeal carcinoma from incomplete multi-modal data
Ren, C.-X., Xu, G.-X., Dai, D., Lin, L. C., Sun, Y. H., & Liu, Q. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103103 · Cited by 11
Han, T., Žigutytė, L., Huck, L. C., Huppertz, M., Siepmann, R. M., Gandelsman, Y., Blüthgen, C., Khader, F., Kuhl, C. K., Nebelung, S., et al. (2024) · Cell Reports Medicine · doi:10.1016/j.xcrm.2024.101713 · Cited by 11
“9 For example, metal tokens in radiographs, used to indicate body sides, can confound the presence of diseases like COVID-19.”
Dumkrieger, G. M., Chiang, C., Zhang, P., Minen, M. T., Cohen, F., & Hranilovich, J. A. (2024) · Headache The Journal of Head and Face Pain · doi:10.1111/head.14880 · Cited by 11
“41 Here the authors created a CNN for identifying pneumonia using X-rays from several hospital departments.”
Harper, J. P., Lee, G. R., Pan, I., Nguyen, X. V., Quails, N., & Prevedello, L. M. S. (2025) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8715 · Cited by 13
Overview of artificial intelligence in hand surgery
Ryhänen, J., Wong, G. C., Anttila, T., & Chung, K. C. (2025) · Journal of Hand Surgery (European Volume) · doi:10.1177/17531934251322723 · Cited by 10
“Strawman bias manifests when experts lack the expected level of expertise for accurate model training and evaluation (Abu-Mostafa et al., 2012; Park and Han, 2018; Zech et al., 2018).”
CNN-LSTM-Based Lung Sound Analysis for Pneumonia Detection
Pandey, P. V. K., Sahu, S. S., Chakravarty, S., & Chin, C. (2025) · IEEE SoutheastCon · doi:10.1109/southeastcon56624.2025.10971692 · Cited by 9
“Caruana et al ., worked on development of an intelligible model using generalized additive models (GAMs) [14] to make generalized additive models with pairwise interactions (GA2Ms) to achieve state-of-the-art accuracy on CXR data [15].”
InfluentialAli, S. A., Arain, K. R., Mushtaq, N.-U.-A., & Rehman, O. U. (2025) · VFAST Transactions on Software Engineering · doi:10.21015/vtse.v13i2.2082 · Cited by 12
Acute kidney injury: Detection, risk stratification, and predictive biomarkers
Bithi, N., Daniel, E. J. P., & Devaraj, S. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.120830 · Cited by 12
Pneumonia Diagnosis on Chest X-Rays with Machine Learning
Meng, Z., Meng, L., & Tomiyama, H. (2021) · Procedia Computer Science · doi:10.1016/j.procs.2021.04.032 · Cited by 10
Artificial Intelligence and Cardiac PET/Computed Tomography Imaging
Miller, R. J. H., Singh, A., Dey, D., & Slomka, P. J. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.011 · Cited by 9
Wang, J., Chavda, V. P., Prajapati, R., Bedse, A. P., Patel, J., Popat, S., Jogi, G., Nalla, L. V., Jetha, K. L., Shen, B., et al. (2023) · Current Research in Biotechnology · doi:10.1016/j.crbiot.2023.100159 · Cited by 10
Fast Diffusion-Based Counterfactuals for Shortcut Removal and Generation
Weng, N., Pegios, P., Petersen, E., Feragen, A., & Bigdeli, S. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-73016-0_20 · Cited by 54
Lung Nodule Sizes Are Encoded When Scaling CT Image for CNN's
Cherezov, D., Paul, R., Fetisov, N., Gillies, R. J., Schabath, M. B., Goldgof, D. B., & Hall, L. (2020) · Tomography · doi:10.18383/j.tom.2019.00024 · Cited by 9
“(11) presented a CNN model for pneumonia detection in chest xray images and showed that the resulting model could identify hospitals, departments, and imaging device because patients with different risk scores of pneumonia were scanned using different imaging protocols.”
BackgroundNomura, Y., Hanaoka, S., Nakao, T., Hayashi, N., Yoshikawa, T., Miki, S., Watadani, T., & Abe, O. (2021) · Japanese Journal of Radiology · doi:10.1007/s11604-021-01153-1 · Cited by 11
Ravindran, P., Wade, A. C., Owens, F. C., Shmulsky, R., & Wiedenhoeft, A. C. (2022) · Canadian Journal of Forest Research · doi:10.1139/cjfr-2022-0077 · Cited by 14
Tahghighi, P., Appleby, R. B., Norena, N., Ukwatta, E., & Komeili, A. (2023) · American Journal of Veterinary Research · doi:10.2460/ajvr.23.03.0062 · Cited by 11
“Nonetheless, as stated by Zach et al, 24 the performance of CNNs may vary significantly from one site to another, primarily related to the imaging device parameters and acquisition technique.”
BackgroundMethodLessons From Deep Neural Networks for Studying the Coding Principles of Biological Neural Networks
Bae, H., Kim, S. J., & Kim, C.-E. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2020.615129 · Cited by 12
“It may seem to be accurate for objects in a “common” context (e.g., a cow in a pasture) but unexpectedly fail on objects in an uncommon context (e.g., a cow on the beach) ( Supplementary Figure 1 ) (Szegedy et al., 2013; Beery et al., 2018; Zech et al., 2018).”
BackgroundAugmenting Decision Competence in Healthcare Using AI-based Cognitive Models
Keller, N., Jenny, M. A., Spies, C. A., & Herzog, S. M. (2020) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi48887.2020.9374376 · Cited by 16
Causal bootstrappingPreprint
Little, M. A., & Badawy, R. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.09648 · Cited by 34
“For example, empirical evidence points to these predictors easily exploiting spurious associations in observational data [Zech et al., 2018, Chyzhyk et al., 2018, Kaufman et al., 2012, Neto et al., 2019, Neto, 2018].”
BackgroundMethodZhang, Y., Wu, H., Liu, H., Li, T., & Wang, M. D. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.06745 · Cited by 17
“Another group of researchers [5] analyzed the generalization capability of deep learning models in screening pneumonis on Chest X-ray images and reported the followings: (1) Convolution Neural Network (CNN) models performed significantly worse (about 8% to 10% drop) in external hospital system than internal hold-out t…”
BackgroundNew Innovation Models in Medical AIPreprint
Price, W. N., II, Sachs, R. E., & Eisenberg, R. S. (2021) · SSRN Electronic Journal · doi:10.2139/ssrn.3783879 · Cited by 12
Hitting the Mark: Reducing Bias in AI Systems
Kahn, C. E. (2022) · Radiology Artificial Intelligence · doi:10.1148/ryai.220171 · Cited by 9
Deep learning applied to the imaging diagnosis of hepatocellular carcinoma
Ballotin, V. R., Bigarella, L. G., Soldera, J., & Soldera, J. (2021) · Artificial Intelligence in Gastrointestinal Endoscopy · doi:10.37126/aige.v2.i4.127 · Cited by 8
Topological structure of complex predictions
Liu, M., Dey, T. K., & Gleich, D. F. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00749-8 · Cited by 16
“Yet challenges in generalization may keep deep learning from use in practice [51, 30].”
BackgroundSelf-citationTahghighi, P., Appleby, R. B., Norena, N., Ukwatta, E., & Komeili, A. (2024) · Veterinary Radiology & Ultrasound · doi:10.1111/vru.13373 · Cited by 11
Hamon, G., Legrand, L., Hmeydia, G., Turc, G., Hassen, W. B., Charron, S., Debacker, C., Naggara, O. N., Thirion, B., Chen, B., et al. (2024) · European Stroke Journal · doi:10.1177/23969873241263418 · Cited by 7
“28 Our work suggests the feasibility of adapting a pre-trained model using a specific supervised domain adaptation method to overcome field strength and manufacturer shift from multicenter MRI data.”
Towards a neuro-symbolic cycle for human-centered explainability
Mileo, A. (2025) · Neurosymbolic Artificial Intelligence · doi:10.3233/nai-240740 · Cited by 18
“…during the California wildfires of 2018 when it was dangerously bad; 4 incorrect diagnosis of pneumonia in chest radiographs as the model was picking up on the word ‘portable’ within the X-ray image, representing the type of X-ray equipment rather than the medical content of the image [53].”
Curriculum check, 2025—equipping radiology residents for AI challenges of tomorrow
Venugopal, V. K., Kumar, A., Tan, M. O., & Szarf, G. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-05016-5 · Cited by 13
“They must recognize that high internal accuracy does not ensure generalizability and that external validation remains the gold standard for clinical reliability [13].”
Liu, Y., Deng, K., Zhang, C.-W., Yuan, Z., Zhou, J., & Liu, C. (2025) · Aesthetic Plastic Surgery · doi:10.1007/s00266-025-05068-4 · Cited by 12
“The blue line represents the time span, while embedded red line within indicates the duration of the keyword burst community hospital datasets [41], demonstrating that data quality fundamentally supersedes quantity.”
AI-based EEG analysis: new technology and the path to clinical adoption
Rutkowski, J., & Saab, M. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.2110994 · Cited by 8
Wolak, W., Plichta, A., & Orlicki, H. (2025) · Scientific Reports · doi:10.1038/s41598-025-31079-x · Cited by 14
“Evidence from other fields underscores this problem: Zech et al. (2018) demonstrated that convolutional neural networks trained to detect pneumonia on chest X-rays achieved substantially higher performance on internal datasets compared to external test sets, warning that “estimates of CNN…”
Hamamoto, R., Koyama, T., Takahashi, S., Yasuda, T., Kobayashi, K., Akagi, Y., Kouno, N., Sudo, K., Hirata, M., Sunami, K., et al. (2026) · Journal of Hematology & Oncology · doi:10.1186/s13045-026-01781-y · Cited by 8
“In parallel, performance may drift across institutions due to differences in sequencing panels, EHR structure, imaging protocols, pathology preparation, and local documentation practices (domain shift), which can impair the portability of both text-only and multimodal models [160, 161].”
Hwang, E. J., Lee, J. H., Kim, J. H., Lim, W. H., Goo, J. M., & Park, C. M. (2021) · BMC Pulmonary Medicine · doi:10.1186/s12890-021-01768-0 · Cited by 13
“Thus, it remains difficult to believe that deep learning-based CAD truly proved their clinical usefulness in pneumonia detection [22].”
BackgroundInfluentialDetecting total hip arthroplasty dislocations using deep learning: clinical and Internet validation
Wei, J., Li, D., Sing, D. C., Yang, J., Beeram, I. R., Puvanesarajah, V., Valle, C. J. D., Tornetta, P., Fritz, J. M., & Yi, P. H. (2022) · Emergency Radiology · doi:10.1007/s10140-022-02060-2 · Cited by 9
“…are promising, external testing of CNNs is paramount to evaluate for generalizability of this performance, as CNNs for medical imaging have demonstrated drops in performance when evaluated on testing data sourced differently (e.g., from a different hospital) than training and validation data [24].”
BackgroundMallon, D. H., McNamara, C., Rahmani, G., O’Regan, D. P., & Amiras, D. (2022) · Clinical Radiology · doi:10.1016/j.crad.2022.06.011 · Cited by 11
Minimum standards for evaluating machine-learned models of high-dimensional data
Chen, B. H. (2022) · Frontiers in Aging · doi:10.3389/fragi.2022.901841 · Cited by 9
“Another more medically related example was a study of chest x-rays, which were used to build a machine learning model to detect pneumonia only to find that the models were focused on artifacts in the image that denoted which hospital the images were taken (Zech et al., 2018).”
Detecting upper extremity native joint dislocations using deep learning: A multicenter study
Wei, J., Li, D., Sing, D. C., Beeram, I. R., Puvanesarajah, V., Tornetta, P., Fritz, J. M., & Yi, P. H. (2022) · Clinical Imaging · doi:10.1016/j.clinimag.2022.09.005 · Cited by 9
Jin, X., Hao, Y. W., Hilliard, J., Zhang, Z., Thomas, M., Li, H., Jha, A. K., & Hugo, G. D. (2023) · Medical Physics · doi:10.1002/mp.16846 · Cited by 12
Cappelletti, L., Rekerle, L., Fontana, T., Hansen, P., Casiraghi, E., Ravanmehr, V., Mungall, C., Yang, J. J., Spranger, L., Karlebach, G., et al. (2024) · Bioinformatics Advances · doi:10.1093/bioadv/vbae036 · Cited by 12
“One reason for this might be that published models not infrequently display methodological flaws or underlying biases (Zech et al. 2018, Biderman and Scheirer 2020; Wynants et al. 2020, Roberts et al. 2021).”
BackgroundFogleman, B. M., Goldman, M., Holland, A. B., Dyess, G. A., & Patel, A. (2024) · Cureus · doi:10.7759/cureus.58032 · Cited by 20
López, P. D. D., Cárdenas‐Montes, M., Troya, J., Ocaña-Tienda, B., Cepeda, S., Martínez, R. M., & Corrales-García, E. M. (2025) · Clinical & Translational Oncology · doi:10.1007/s12094-025-03948-4 · Cited by 10
“Furthermore, the manual annotation of neuroimaging or histopathological data is labor-intensive, susceptible to inter-observer variability, and often lacks standardization across centers, reducing the reproducibility of AI outputs [87].”
Visual attribution for deep learning segmentation in medical imaging
Mullan, S. M., & Milan Sonka, A. (2022) · SPIE Medical Imaging: Image Processing · doi:10.1117/12.2612288 · Cited by 9
“Without a detailed understanding of how a deep learning model works, we are unable to validate if the accuracy of the model will generalize beyond the lab environment and perform well in a clinical setting.(4) Two key medical imaging tasks that CNNs are applied to are classification, providing a single decision for an…”
BackgroundSpiller, T. R., Tufan, E., Petry, H., Böttger, S., Fuchs, S., Duek, O. A., Ben‐Zion, Z., Korem, N., Harpaz‐Rotem, I., von Känel, R., et al. (2022) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2022.10.018 · Cited by 8
GAN Latent Space Manipulation and Aggregation for Federated Learning in Medical Imaging
Pennisi, M., Salanitri, F. P., Palazzo, S., Pino, C., Rundo, F., Giordano, D., & Spampinato, C. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-18523-6_7 · Cited by 10
Park, S. H., Choi, J., & Byeon, J. (2020) · Journal of Korean Medical Association · doi:10.5124/jkma.2020.63.11.696 · Cited by 8
Effect of Different Batch Size Parameters on Predicting of COVID19 Cases
Narin, A., & Pamuk, Z. (2020) · Journal of Intelligent Systems with Applications · doi:10.54856/jiswa.202012119 · Cited by 10
The Utility of General Domain Transfer Learning for Medical Language TasksPreprint
Ranti, D. L., Hanss, K., Zhao, S., Arvind, V., Titano, J. J., Costa, A. B., & Oermann, E. K. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2002.06670 · Cited by 9
Self-citationMulti-Task Learning in Histo-pathology for Widely Generalizable ModelPreprint
Gamper, J., Koohbanani, N. A., & Rajpoot, N. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2005.08645 · Cited by 10
“Some recent studies have pointed to limited clinical applicability of AI due to weak experimental design even with datasets obtained in the developed world (Liu et al., 2019; Zech et al., 2018).”
BackgroundGeneralization and Invariances in the Presence of Unobserved Confounding.Preprint
Bellot, A., & van der Schaar, M. (2020) · arXiv (Cornell University) · Cited by 13
Continental generalization of an AI system for clinical seizure recognitionPreprint
Yang, Y., Truong, N. D., Maher, C., Nikpour, A., & Kavehei, O. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.03.07.433990 · Cited by 8
Park, S. J., Kim, G., Oh, Y., Seo, J. B., Lee, S. M., Kim, J. H., Moon, S.-J., Lim, J., & Ye, J. C. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2104.07235 · Cited by 8
“…quantification of COVID-19 (Cohen et al., 2020a; Signoroni et al., 2020a; Zhu et al., 2020a; Wong et al., 2020), but they suffered from ineradicable drawbacks of poor generalization capability stemming from the scanty labelled COVID-19 data (Hu et al., 2020; Zech et al., 2018; Roberts et al., 2021).”
BackgroundAn Information-theoretic Approach to Distribution ShiftsPreprint
Federici, M., Tomioka, R., & Forré, P. D. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.03783 · Cited by 20
“, 2018), data collected on a limited set of hospitals may not be representative of the variation introduced by the use of different machines or procedures (Zech et al., 2018; Beede et al., 2020).”
BackgroundNow You See It, Now You Dont: Adversarial Vulnerabilities in Computational PathologyPreprint
Foote, A., Asif, A., Azam, A. S., Marshall-Cox, T., Rajpoot, N., & Minhas, F. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.08153 · Cited by 20
“There is substantial evidence to show that ML models can exploit unexpected properties of a task to achieve high accuracy, including in the context of medical imaging [34].”
BackgroundWhat Is Needed for Artificial Intelligence to Be Trusted?
Pellikka, P. A., Hamza, I., & Carter, R. E. (2021) · The American Journal of Medicine · doi:10.1016/j.amjmed.2021.11.010 · Cited by 8
An open, analysis-ready, and quality controlled resource for pediatric brain white-matter researchPreprint
Richie-Halford, A., Cieslak, M., Ai, L., Caffarra, S., Covitz, S. C., Franco, A. R., Karipidis, I. I., Kruper, J., Milham, M. P., Avelar‐Pereira, B., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.02.24.481303 · Cited by 8
ClinVec: Unified Embeddings of Clinical Codes Enable Knowledge-Grounded AI in MedicinePreprint
Johnson, R., Gottlieb, U., Shaham, G., Eisen, L., Waxman, J. G., Devons-Sberro, S., Ginder, C. R., Hong, P. J., Sayeed, R., Su, X., et al. (2024) · medRxiv · doi:10.1101/2024.12.03.24318322 · Cited by 8
On the Readiness of Scientific Data Papers for a Fair and Transparent Use in Machine Learning
Giner-Miguelez, J., Gómez, A., & Cabot, J. (2025) · Scientific Data · doi:10.1038/s41597-025-04402-4 · Cited by 15
Kim, J., Oh, S. W., Lee, H. Y., Choi, M. H., Meyer, H., Huwer, S., Zhao, G., Gibson, E., & Han, D. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.04.046 · Cited by 8
de Vente, C., Valmaggia, P., Hoyng, C. B., Holz, F. G., Islam, M. M., Klaver, C. C. W., Boon, C. J. F., Schmitz-Valckenberg, S., Tufail, A., Saßmannshausen, M., et al. (2024) · Translational Vision Science & Technology · doi:10.1167/tvst.13.9.11 · Cited by 10
Park, K., Lim, J., Shin, S. H., Ryu, M., Shin, H., Lee, M., Hong, S. W., Hwang, S. W., Park, S. H., Yang, D., et al. (2024) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.16788 · Cited by 9
“30,31 Furthermore, although the overall accuracy of pooled observers with AI-assisted interpretation was 88.8% in the external dataset, which was not markedly superior to the accuracies of the aforementioned diagnostic methods in previous literatures, it is signi fi cant as it introduces a new…”
InfluentialKromrey, M., Steiner, L., Schön, F., Gamain, J., Roller, C., & Malsch, C. (2024) · Healthcare · doi:10.3390/healthcare12222225 · Cited by 9
AI-assisted detection for chest X-rays (AID-CXR): a multi-reader multi-case study protocol
Khan, F. A., Das, I., Kotnik, M., Wing, L., van Beek, E. J. R., Murchison, J. T., Ahn, J. S., Lee, S. H., Seth, A., Morgado, A. T. E., et al. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-080554 · Cited by 9
Fracture detection of distal radius using deep-learning-based dual-channel feature fusion algorithm
Li, J., Shan, H.-J., & Yu, X.-W. (2025) · Chinese Journal of Traumatology · doi:10.1016/j.cjtee.2024.10.006 · Cited by 9
“Zech et al. 32 highlighted that models trained on data from a single source might exhibit reduced generalizability across diverse populations and environments.”
Yadav, V. K., & Singhai, J. (2025) · IETE Technical Review · doi:10.1080/02564602.2025.2501936 · Cited by 10
Howard, J. P., Zhang, Q., Salih, A. M., Petersen, S. E., Lekadir, K., & Raisi‐Estabragh, Z. (2025) · Heart · doi:10.1136/heartjnl-2024-324612 · Cited by 14
Challenges and Strategies for Deep Learning in Cardiovascular Imaging
Pasdeloup, D., Østvik, A., Olaisen, S. H., Skogvoll, E., Dalen, H., & Løvstakken, L. (2025) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2025.02.011 · Cited by 11
Chang, L., Li, H., Wu, W., Liu, X., Yan, J., Chen, Z., Wu, H., & Song, S. (2025) · Journal of Translational Medicine · doi:10.1186/s12967-025-07591-z · Cited by 10
“…biases—including site/ scanner fingerprints, stage distribution, smoking status, ancestry, and socioeconomic proxies—that models learn and amplify [179]; (iv) leakage risks (patient overlap across splits and refitting normalization on combined data) that overstate performance [180]; and (v)…”
Han, Q., Jing, F., Sun, Z., Liu, F., Zhang, J., Wang, J., & Liang, H. (2023) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-22-1115 · Cited by 8
Matsuyama, E., Nishiki, M., Takahashi, N., & Watanabe, H. (2024) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2024.171001 · Cited by 8
Zhang, J., Xiao, F., Zou, H., Feng, R. E., & He, J. (2024) · iScience · doi:10.1016/j.isci.2024.110566 · Cited by 7
“19 These limitations likely stem from the SL training methodology, which promotes the creation of ‘‘specialist models’’ focused on label-specific features rather than on fea-turesthatbroadlyrepresentdatadistribution.”
Zhang, Q., Shao, D., Lin, L., Gong, G., Xu, R., Kido, S., & Cui, H. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3481012 · Cited by 8
“Zech et al. (2018) [5] found inconsistencies in DL’s pneumonia detection in X-rays, likely due to training-test data differences.”
Hoebers, F. J. P., Wee, L., Likitlersuang, J., Mak, R. H., Bitterman, D. S., Huang, Y., Dekker, A. L. A. J., Aerts, H. J. W. L., & Kann, B. H. (2023) · BJR|Open · doi:10.1093/bjro/tzae039 · Cited by 14
Lee, M. C. M., Farahvash, A., & Zezos, P. (2025) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izaf050 · Cited by 9
Artificial Intelligence Applications to Improve Risk Prediction Tools in Electrophysiology
Kowlgi, G. N., Ezzeddine, F. M., & Kapa, S. (2020) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-020-00649-1 · Cited by 6
Evaluation of Machine Learning Architectures in Healthcare
Verma, Y., & Tayeb, S. (2021) · IEEE Annual Computing and Communication Workshop and Conference (CCWC) · doi:10.1109/ccwc51732.2021.9375834 · Cited by 7
“Zech et al. [19] publish another paper to detect and classify Pneumonia from X-rays.”
BackgroundCross-site Epileptic Seizure Detection Using Convolutional Neural Networks
Currey, D., Hsu, D., Ahmed, R., Venkataraman, A., & Craley, J. (2021) · Conference on Information Sciences and Systems · doi:10.1109/ciss50987.2021.9400222 · Cited by 7
“Studies have shown that results suffer when models are used on new clinical data sets [3], [4].”
BackgroundCritical Appraisal of a Machine Learning Paper: A Guide for the Neurologist
Vinny, P. W., Garg, R. D., Srivastava, M. P., Lal, V., & Vishnu, V. Y. (2021) · Annals of Indian Academy of Neurology · doi:10.4103/aian.aian_1120_20 · Cited by 8
“[27] Similarly, another model learnt to diagnose pneumonia from chest X-rays based on the increased association between a portable X-ray machine used for recording X rays and pneumonia.[40] These are examples of the model adjusting its parameters to spurious signals within the development dataset.”
Backgroundvan der Kamp, A., Waterlander, T. J., de Bel, T., van der Laak, J. A. W. M., van den Heuvel‐Eibrink, M. M., Mavinkurve‐Groothuis, A. M. C., & de Krijger, R. R. (2022) · Pediatric and Developmental Pathology · doi:10.1177/10935266211059809 · Cited by 7
“For example, in a study of Zech et al, 66 the developed AI model determined the risk prediction on the basis of meta-data related to the type of X-ray machine instead of patient data.”
Understanding required to consider AI applications to the field of ophthalmology
Tabuchi, H. (2022) · Taiwan Journal of Ophthalmology · doi:10.4103/tjo.tjo_8_22 · Cited by 7
“[24] Caution needs to be exercised when an AI diagnostic application is applied to an area outside the prescribed frame.”
BackgroundCancer immunotherapy efficacy and machine learning
Fang, Y., Chen, X., & Cao, C. (2024) · Expert Review of Anticancer Therapy · doi:10.1080/14737140.2024.2311684 · Cited by 7
“There is some variation in disease burden across systems and departments, and the accuracy of the DL model’s predictions will vary [73].”
BackgroundThe future of artificial intelligence in healthcare
Radakovich, N., & Nazha, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820273-9.00016-6 · Cited by 7
Matsuyama, E., Watanabe, H., & Takahashi, N. (2022) · Open Journal of Medical Imaging · doi:10.4236/ojmi.2022.123009 · Cited by 7
“ages were learned as strong features for classification [6].”
BackgroundClassification of Pediatric Pneumonia Prediction Approaches
Singh, A., Shalini, S., & Garg, R. (2021) · International Conference on Cloud Computing, Data Science & Engineering (Confluence) · doi:10.1109/confluence51648.2021.9376884 · Cited by 7
Learning Predictive Models That Transport.Preprint
Subbaswamy, A., Schulam, P., & Saria, S. (2018) · arXiv (Cornell University) · Cited by 8
Left ventricle segmentation in the era of deep learning
Wolterink, J. M. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-01674-3 · Cited by 7
Horry, M. J., Chakraborty, S., Pradhan, B., Fallahpoor, M., Chegeni, H., & Paul, M. (2021) · doi:10.31224/osf.io/tfqa4 · Cited by 7
Jha, A. K., Myers, K. J., Obuchowski, N. A., Liu, Z., Rahman, A., Saboury, B., Rahmim, A., & Siegel, B. A. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2107.04540 · Cited by 7
Metadata
- Authors
- Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K.
- Affiliations
- California Pacific Medical Center (US)
- Verily Life Sciences LLC (United States) (US)
- Icahn School of Medicine at Mount Sinai (US)
- Corresponding author
- Oermann, Eric Karl
- ORCID
- Venue
- PLOS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-11-06
- Volume
- 15
- Issue
- 11
- Pages
- e1002683
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- PMC
- PMC6219764
- OpenAlex
- W2811374795
- Cited by
- 1,719
- References
- 34
- Citations by year
- 2026: 412 · 2025: 212 · 2024: 186 · 2023: 190 · 2022: 206 · 2021: 236 · 2020: 173 · 2019: 90 · 2018: 12
- FWCI
- 87.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Icahn School of Medicine at Mount Sinai
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- pneumonia detection, chest radiograph, convolutional neural networks, model generalization, external validation, computer-aided diagnosis, pneumonia screening, split-sample validation, radiographic findings, deep learning for medical imaging
- MeSH terms
- Deep Learning, Adult, Aged, Cross-Sectional Studies, Diagnosis, Computer-Assisted, Female, Humans, Male, Middle Aged, Pneumonia, Predictive Value of Tests, Radiographic Image Interpretation, Computer-Assisted, Radiology Information Systems, Retrospective Studies, Radiography, Thoracic, United States, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.