Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There is interest in using convolutional neural networks (CNNs) to analyze medical imaging to provide computer-aided diagnosis (CAD). Recent work has suggested that image classification CNNs may not generalize to new data as well as previously believed. We assessed how well CNNs generalized across three hospital systems for a simulated pneumonia screening task. METHODS AND FINDINGS: A cross-sectional design with multiple model training cohorts was used to evaluate model generalizability to external sites using split-sample validation. A total of 158,323 chest radiographs were drawn from three institutions: National Institutes of Health Clinical Center (NIH; 112,120 from 30,805 patients), Mount Sinai Hospital (MSH; 42,396 from 12,904 patients), and Indiana University Network for Patient Care (IU; 3,807 from 3,683 patients). These patient populations had an age mean (SD) of 46.9 years (16.6), 63.2 years (16.5), and 49.6 years (17) with a female percentage of 43.5%, 44.8%, and 57.3%, respectively. We assessed individual models using the area under the receiver operating characteristic curve (AUC) for radiographic findings consistent with pneumonia and compared performance on different test sets with DeLong's test. The prevalence of pneumonia was high enough at MSH (34.2%) relative to NIH and IU (1.2% and 1.0%) that merely sorting by hospital system achieved an AUC of 0.861 (95% CI 0.855-0.866) on the joint MSH-NIH dataset. Models trained on data from either NIH or MSH had equivalent performance on IU (P values 0.580 and 0.273, respectively) and inferior performance on data from each other relative to an internal test set (i.e., new data from within the hospital system used for training data; P values both <0.001). The highest internal performance was achieved by combining training and test data from MSH and NIH (AUC 0.931, 95% CI 0.927-0.936), but this model demonstrated significantly lower external performance at IU (AUC 0.815, 95% CI 0.745-0.885, P = 0.001). To test the effect of pooling data from sites with disparate pneumonia prevalence, we used stratified subsampling to generate MSH-NIH cohorts that only differed in disease prevalence between training data sites. When both training data sites had the same pneumonia prevalence, the model performed consistently on external IU data (P = 0.88). When a 10-fold difference in pneumonia rate was introduced between sites, internal test performance improved compared to the balanced model (10× MSH risk P < 0.001; 10× NIH P = 0.002), but this outperformance failed to generalize to IU (MSH 10× P < 0.001; NIH 10× P = 0.027). CNNs were able to directly detect hospital system of a radiograph for 99.95% NIH (22,050/22,062) and 99.98% MSH (8,386/8,388) radiographs. The primary limitation of our approach and the available public data is that we cannot fully assess what other factors might be contributing to hospital system-specific biases. CONCLUSION: Pneumonia-screening CNNs achieved better internal than external performance in 3 out of 5 natural comparisons. When models were trained on pooled data from sites with different pneumonia prevalence, they performed better on new pooled data from these sites but not on external data. CNNs robustly identified hospital system and department within a hospital, which can have large differences in disease burden and may confound predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thus, the system was able to distinguish only which machine was used for imaging and not the risk of the patients.”
From Explainability for artificial intelligence in healthcare: a multidisciplinary perspective (2020) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In a study training AI to diagnose pneumonia from chest X-rays, the performance on unseen data from the institution where the training data were collected was significantly higher than its performance on data collected from external hospitals [72].”
From Fairness of artificial intelligence in healthcare: review and recommendations (2024) · cites this paper as [72]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Shortcut learning, in which a model latches onto a spurious correlate (eg, the scanner used at a particular site, a hospital-specific text template) rather than the clinical signal of interest, has been repeatedly documented in medical AI and can be difficult to detect without deliberate probing.62”
From Artificial Intelligence in Oncology: Practical Applications Across Clinical Care, Scholarship, and Translation. (2026) · cites this paper as [62]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This study hypothesized that multicenter training could enhance the generalizability of AI models, which has previously been demonstrated in other medical imaging scenarios25–27.”
From Federated deep learning for detecting COVID-19 lung abnormalities in CT: a privacy-preserving multinational validation study (2021) · cites this paper as [26]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, variations in data collection and processing can degrade model accuracy on data from new hospital deployments (Zech et al., 2018; AlBadawy et al., 2018).”
From WILDS: A Benchmark of in-the-Wild Distribution Shifts (2020) · cites this paper as Zech et al., 2018
12 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 2×
“Many different CNN architectures have been proposed, including ResNet-50 and DenseNet-121 used in this paper, and improving the performance of these models is an active area of research [14,15].”
MethodLeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDensely Connected Convolutional Networks
Huang, G., Liu, Z., van der Maaten, L., & Weinberger, K. Q. (2016) · arXiv · doi:10.48550/arxiv.1608.06993 · Cited by 48,960
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380 · cited 1×
“These studies are generally performed utilizing CNN techniques that were pioneered on well characterized computer vision datasets including the ImageNet Large Scale Visual Recognition Competition (ILSVRC) and the Modified National Institute of Standards and Technology (MNIST) database of hand drawn digits [6, 7].”
MethodDeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
(2017) · Cited by 11,625
Cited by
Items 101–200 of 1,005
Federated benchmarking of medical artificial intelligence with MedPerf
Karargyris, A., Umeton, R., Sheller, M. J., Aristizabal, A., George, J., Wuest, A., Pati, S., Kassem, H., Zenk, M., Baid, U., et al. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00652-2 · Cited by 188
“…studies have shown that models trained with data from limited and specific clinical settings are often biased with respect to specific patient populations 11–13 ; such data biases can lead to models that seem promising during development but have lower performance in wider deployment 14,15 .”
Explainable AI under contract and tort law: legal incentives and technical challenges
Hacker, P., Krestel, R., Grundmann, S., & Naumann, F. (2020) · Artificial Intelligence and Law · doi:10.1007/s10506-020-09260-6 · Cited by 186
“The clinical suitability criterion is particularly important in medical contexts where the consequences of false positive or false negative outcomes may be particularly undesirable (Caruana 2015; Zech et al. 2018; Rudin and Ustun 2018).”
BackgroundWickstrøm, K., Kampffmeyer, M., & Jenssen, R. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101619 · Cited by 185
Classification of COVID-19 chest X-rays with deep learning: new models or fine tuning?
Pham, T. D. (2021) · Health Information Science and Systems · doi:10.1007/s13755-020-00135-3 · Cited by 184
Deep Learning and Neurology: A Systematic Review
Valliani, A. A.-A., Ranti, D., & Oermann, E. K. (2019) · Neurology and Therapy · doi:10.1007/s40120-019-00153-8 · Cited by 179
“Much of the concern is based on the tendency of deep learning algorithms to overfit to the statistical characteristics of the training data, rendering them hyperspecialized for a hospital or certain patient demographic and less effective on the population at-large [81, 82].”
BackgroundSelf-citationMårtensson, G., Ferreira, D., Granberg, T., Cavallin, L., Oppedal, K., Padovani, A., Rektorova, I., Bonanni, L., Pardini, M., Kramberger, M. G., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101714 · Cited by 176
“Further, they demonstrated that a CNN could accurately classify which hospital an image was acquired at and thus potentially leverage this information to adjust the prediction method due to different disease prevalences in the cohorts [8].”
BackgroundAllgaier, J., Mulansky, L., Draelos, R. L., & Pryss, R. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102616 · Cited by 170
How far have we come? Artificial intelligence for chest radiograph interpretation
Kallianos, K., Mongan, J., Antani, S., Henry, T., Taylor, A., Abuya, J., & Kohli, M. (2019) · Clinical Radiology · doi:10.1016/j.crad.2018.12.015 · Cited by 173
CAD and AI for breast cancer—recent development and challenges
Chan, H.-P., Samala, R. K., & Hadjiiski, L. M. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20190580 · Cited by 173
“125 As a result, an AI-based CAD tool well trained and independently tested using data collected from some clinical sites may not translate to other sites.”
MethodSharma, S., & Guleria, K. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-16419-1 · Cited by 172
Zebin, T., & Rezvy, S. (2021) · Applied Intelligence · doi:10.1007/s10489-020-01867-1 · Cited by 166
“Deep learning algorithms have already been applied for the detection and classification of Pneumonia [17, 25] and other diseases on radiography.”
MethodArtificial Intelligence and Health Technology Assessment: Anticipating a New Level of Complexity
Alami, H., Lehoux, P., Auclair, Y., de Guise, M., Gagnon, M.-P., Shaw, J., Roy, D., Fleet, R., Ag Ahmed, M. A., & Fortin, J.-P. (2020) · Journal of Medical Internet Research · doi:10.2196/17707 · Cited by 164
“However, this requirement is difficult to achieve [13-16].”
BackgroundWei, L., Niraula, D., Gates, E. D. H., Fu, J., Luo, Y., Nyflot, M. J., Bowen, S. R., El Naqa, I. M., & Cui, S. (2023) · The British Journal of Radiology · doi:10.1259/bjr.20230211 · Cited by 162
Methods for clinical evaluation of artificial intelligence algorithms for medical diagnosis
Park, S. H., Han, K., Jang, H. Y., Park, J. E., Lee, J.-G., Kim, D. W., & Choi, J. (2023) · Radiology · doi:10.1148/radiol.220182 · Cited by 163
A Clinician's Guide to Artificial Intelligence: How to Critically Appraise Machine Learning Studies
Faes, L., Liu, X., Wagner, S. K., Fu, D. J., Balaskas, K., Sim, D. A., Bachmann, L. M., Keane, P. A., & Denniston, A. K. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.7 · Cited by 162
Detection of pneumonia using convolutional neural networks and deep learning
Szepesi, P., & Szilágyi, L. S. (2022) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2022.08.001 · Cited by 200
Barnett, A. J., Schwartz, F. R., Tao, C., Chen, C., Ren, Y., Lo, J. Y., & Rudin, C. (2021) · Nature Machine Intelligence · doi:10.1038/s42256-021-00423-x · Cited by 156
“, type of equipment) rather than medical information [4, 52, 57].”
BackgroundInfluentialPutting the data before the algorithm in big data addressing personalized healthcare
Cahan, E. M., Hernandez-Boussard, T., Thadaney-Israni, S., & Rubin, D. L. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0157-2 · Cited by 149
“35”
Rauschecker, A. M., Rudie, J. D., Xie, L., Wang, J., Duong, M. T., Botzolakis, E. J., Kovalovich, A. M., Egan, J., Cook, T. C., Bryan, R. N., et al. (2020) · Radiology · doi:10.1148/radiol.2020190283 · Cited by 148
“Finally, the retrospective work described here was performed at a single health system, potentially limiting generalization (28).”
MethodDeep Learning for Automatic Pneumonia Detection
Gabruseva, T., Poplavskiy, D., & Kalinin, A. A. (2020) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00183 · Cited by 172
“To improve the efficiency and accuracy of diagnostic services computer-aided diagnosis systems for pneumonia detection has been widely exploited in the last decade [21, 20, 26, 31, 23].”
Clinician checklist for assessing suitability of machine learning applications in healthcare
Scott, I., Carter, S., & Coiera, E. (2021) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2020-100251 · Cited by 143
“35 An algo-rithm used to diagnose pneumonia on chest X-rays in one hospital system failed to generalise to radiographs from another hospital system, due to differences in prevalence of pneumonia between populations 36 (class imbalance).”
MethodEmerging Artificial Intelligence–Empowered mHealth: Scoping Review
Bhatt, P., Liu, J., Gong, Y., Wang, J., & Guo, Y. (2022) · JMIR mhealth and uhealth · doi:10.2196/35053 · Cited by 169
“Using AI techniques in the application of mHealth scenarios can have numerous benefits, such as the automatic detection of chronic disease occurrence [21], real-time prediction and intervention for suicide prevention [37], facilitating emergency response [38], enabling patient rehabilitation [39], providing noninvasiv…”
MethodAnalysis of the Human Protein Atlas Image Classification competition
Ouyang, W., Winsnes, C. F., Hjelmare, M., Cesnik, A. J., Åkesson, L., Xu, H., Sullivan, D. P., Dai, S., Lan, J., Jinmo, P., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0658-6 · Cited by 131
Better medicine through machine learning: What’s real, and what’s artificial?
Saria, S., Butte, A., & Sheikh, A. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002721 · Cited by 127
“Another pitfall of naive implementation lies in the capacity of ML, and particularly deep learning, to overfit to data—that is, to identify associations in the training dataset that are not truly intrinsic to the clinical prediction and will not be relevant externally [16].”
Clinical applications of artificial intelligence in radiology
Mello-Thoms, C. R., & Mello, C. A. B. (2023) · British Journal of Radiology · doi:10.1259/bjr.20221031 · Cited by 160
“10,11 This is because clinical standards and guidelines may change over time, disease prevalence or incidence may change, new imaging equipment may be added to the department, etc., and while humans can easily adapt to these changes, AI systems may succumb because the US Food and Drug…”
Park, S. H., Choi, J., & Byeon, J. (2021) · Korean Journal of Radiology · doi:10.3348/kjr.2021.0048 · Cited by 153
“의료 인공 지능 알고리즘 성능의 일반화에 대한 취 약성을 보여주는 몇 가지 예를 Table 1 에 정리해 놓았다[12-16].”
MethodWhat is new in computer vision and artificial intelligence in medical image analysis applications
Olveres, J., González, G., Torres-Robles, F., Moreno-Tagle, J. C., Carbajal-Degante, E., Valencia-Rodríguez, A., Méndez‐Sánchez, N., & Ramírez, B. E. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-1151 · Cited by 145
“(110) Detect pneumonia on chest radiographies Chest Xray 2018”
Background“Shortcuts” Causing Bias in Radiology Artificial Intelligence: Causes, Evaluation, and Mitigation
Banerjee, I., Bhattacharjee, K., Burns, J. L., Trivedi, H., Purkayastha, S., Seyyed-Kalantari, L., Patel, B. N., Shiradkar, R., & Gichoya, J. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.06.025 · Cited by 122
Machine learning in haematological malignancies
Radakovich, N., Nagy, M. R., & Nazha, A. (2020) · The Lancet Haematology · doi:10.1016/s2352-3026(20)30121-6 · Cited by 145
Intelligent Pneumonia Identification From Chest X-Rays: A Systematic Literature Review
Khan, W., Zaki, N., & Ali, L. (2021) · IEEE Access · doi:10.1109/access.2021.3069937 · Cited by 154
“Furthermore, distinct datasets should be used for training and testing to evaluate the diagnostic accuracy and generalizability of the proposed algorithms [109].”
BackgroundExpert-augmented machine learning
Gennatas, E. D., Friedman, J. H., Ungar, L. H., Pirracchio, R., Eaton, E., Reichmann, L. G., Interian, Y., Luna, J. M., Simone, C. B., Auerbach, A., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1906831117 · Cited by 120
“…that the CNN was basing some of its predictions on image artifacts that identified hospitals with higher prevalence of pneumonia or discriminated regular from portable radiographs (the latter is undertaken on sicker patients), while pathology present in the image was sometimes disregarded (7).”
BackgroundPark, S. J., Kim, G., Oh, Y., Seo, J. B., Lee, S. M., Kim, J. H., Moon, S.-J., Lim, J., & Ye, J. C. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102299 · Cited by 139
“…quantification of COVID-19 (Cohen et al., 2020a; Signoroni et al., 2020a; Zhu et al., 2020a; Wong et al., 2020), but they suffered from ineradicable drawbacks of poor generalization capability stemming from the scanty labelled COVID-19 data (Hu et al., 2020; Zech et al., 2018; Roberts et al., 2021).”
BackgroundOptimal Sparse Decision TreesPreprint
Hu, X., Rudin, C. D., & Seltzer, M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.12847 · Cited by 119
“[22] J.”
Higgins, D., & Madai, V. I. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000052 · Cited by 118
“In that case, the model might learn to identify that hardware-tag instead of the pathology [38].”
BackgroundJiao, Z., Choi, J. W., Halsey, K., Tran, T. M. L., Hsieh, B., Wang, D., Eweje, F., Wang, R., Chang, K., Wu, J., et al. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00039-x · Cited by 116
“Although a lower performance on external testing is a common finding in deep-learning studies using multi-institutional data, 26,27 including our study, the addition of chest x-rays to clinical data improved the artificial performance on both internal and external testing.”
BackgroundCurrent challenges of implementing artificial intelligence in medical imaging
Saw, S. N., & Ng, K. H. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.06.003 · Cited by 151
“Furthermore, AI models were found to have poor generalisability [34].”
BackgroundTackling prediction uncertainty in machine learning for healthcare
Chua, M., Kim, D., Choi, J., Lee, N. G., Deshpande, V., Schwab, J., Lev, M. H., Gonzalez, R. G., Gee, M. S., & Do, S. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00988-x · Cited by 114
Clinical implementation of AI technologies will require interpretable AI models
Jia, X., Ren, L., & Cai, J. (2020) · Medical Physics · doi:10.1002/mp.13891 · Cited by 113
Behzadi-khormouji, H., Rostami, H., Salehi, S., Derakhshande-Rishehri, T., Masoumi, M., Salemi, S., Keshavarz, A., Gholamrezanezhad, A., Assadi, M., & Batouli, A. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.105162 · Cited by 112
Jha, A. K., Bradshaw, T. J., Buvat, I., Hatt, M., KC, P., Liu, C., Obuchowski, N. F., Saboury, B., Slomka, P. J., Sunderland, J. J., et al. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.263239 · Cited by 110
“Results for one population may not necessarily translate to others ( 5,7 ).”
BackgroundMethodArtificial Intelligence in Imaging: The Radiologist’s Role
Rubin, D. L. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.05.036 · Cited by 110
“…an AI algorithm (both single institution and multi-institution) to detect pneumonia for testing found that the performance of the AI algorithm varied substantially [45], and decrease in performance of AI algorithms on independently collected data has been observed by other workers as well [46].”
MethodChoi, J. W., Cho, Y. J., Lee, S., Lee, J. S., Lee, S., Choi, Y. H., Cheon, J., & Ha, J. Y. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000615 · Cited by 119
Artificial intelligence and explanation: How, why, and when to explain black boxes
Marcus, E., & Teuwen, J. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111393 · Cited by 139
Artificial intelligence in radiology
Filipović-Grčić, L., & Đerke, F. (2019) · Rad Hrvatske akademije znanosti i umjetnosti Medicinske znanosti · doi:10.21857/y26kec3o79 · Cited by 119
Brain Tumor Detection using MRI Images and Convolutional Neural Network
Lamrani, D., Cherradi, B., Gannour, O. E., Bouqentar, M. A., & Bahatti, L. (2022) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2022.0130755 · Cited by 114
Detecting shortcut learning for fair medical AI using shortcut testing
Brown, A., Tomasev, N., Freyberg, J., Liu, Y., Karthikesalingam, A., & Schrouff, J. (2023) · Nature Communications · doi:10.1038/s41467-023-39902-7 · Cited by 105
“In prior work detecting shortcut learning, the typical assumption is that any effect of the attribute on model output is spurious 21,22 .”
Beyond generalization: a theory of robustness in machine learning
Freiesleben, T., & Grote, T. (2023) · Synthese · doi:10.1007/s11229-023-04334-9 · Cited by 106
“When transferred to real-world clinical settings, this is likely to result in diagnostic errors (Zech et al., 2018).”
BackgroundNoninterpretive Uses of Artificial Intelligence in Radiology
Richardson, M. L., Garwood, E. R., Lee, Y. Z., Li, M., Lo, H. S., Nagaraju, A., Nguyen, X. V., Probyn, L. J., Rajiah, P. S., Sin, J. M., et al. (2020) · Academic Radiology · doi:10.1016/j.acra.2020.01.012 · Cited by 123
Classification of optical coherence tomography images using a capsule network
Tsuji, T., Hirose, Y., Fujimori, K., Hirose, T., Oyama, A., Saikawa, Y., Mimura, T., Shiraishi, K., Kobayashi, T., Mizota, A., et al. (2020) · BMC Ophthalmology · doi:10.1186/s12886-020-01382-4 · Cited by 115
Weak supervision as an efficient approach for automated seizure detection in electroencephalography
Saab, K., Dunnmon, J., Ré, C., Rubin, D., & Lee-Messer, C. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0264-0 · Cited by 103
Feeny, A. K., Rickard, J., Patel, D. R., Toro, S., Trulock, K. M., Park, C. J., LaBarbera, M. A., Varma, N., Niebauer, M. J., Sinha, S. K., et al. (2019) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007316 · Cited by 127
Artificial intelligence-based pathology for gastrointestinal and hepatobiliary cancers
Calderaro, J., & Kather, J. N. (2021) · Gut · doi:10.1136/gutjnl-2020-322880 · Cited by 101
Voter, A. F., Larson, M. E., Garrett, J. W., & Yu, J.-P. J. (2021) · American Journal of Neuroradiology · doi:10.3174/ajnr.a7179 · Cited by 100
“16-18 Thus, rigorous studies to guide AI DSS installations in varied clinical settings and a greater understanding of the generalizability (or lack thereof) of AI DSSs are needed to safely translate this important tool into widespread clinical practice.”
BackgroundRajinikanth, V., Dey, N., Raj, A. N. J., Hassanien, A. E., Santosh, K., & Raja, N. S. M. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2004.03431 · Cited by 139
Applications of Artificial Intelligence for Retinopathy of Prematurity Screening
Campbell, J. P., Singh, P., Redd, T. K., Brown, J. M., Shah, P. K., Subramanian, P., Rajan, R. P., Valikodath, N. G., Cole, E. D., Ostmo, S. R., et al. (2021) · PEDIATRICS · doi:10.1542/peds.2020-016618 · Cited by 110
Use HiResCAM instead of Grad-CAM for faithful explanations of convolutional neural networksPreprint
Draelos, R. L., & Carin, L. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2011.08891 · Cited by 385
“[63] used class activation mapping [65] to reveal that a CNN trained to predict pneumonia from chest radiographs leveraged non-medical features to make the pneumonia prediction.”
Pneumonia Detection Using Deep Learning Approaches
Tilve, A., Nayak, S., Vernekar, S., Turi, D., Shetgaonkar, P. R., & Aswale, S. (2020) · International Conference on Emerging Trends in Information Technology and Engineering (ICETITE) · doi:10.1109/ic-etite47903.2020.152 · Cited by 118
“In [6] the authors obtained the data from three separate hospital system and asses how CNNs generalized across three hospital system for pneumonia detection.”
BackgroundArtificial intelligence and radiomics: fundamentals, applications, and challenges in immunotherapy
Dercle, L., McGale, J., Sun, S. H., Marabelle, A., Yeh, R., Deutsch, É., Mokrane, F., Farwell, M. D., Ammari, S., Schöder, H. M., et al. (2022) · Journal for ImmunoTherapy of Cancer · doi:10.1136/jitc-2022-005292 · Cited by 109
“…location of primary tumor, (4) imaging modality, (5) primary and secondary study objectives, (6) data collection strategy (retrospective vs prospective, single center vs multicenter), (7) radiomic signature validation strategy, (8) signature performance, and (9) metrics for calculation of an RQS.”
BackgroundCurrent limitations to identify COVID-19 using artificial intelligence with chest X-ray imaging
López-Cabrera, J. D., Orozco‐Morales, R., Portal-Díaz, J. A., Enríquez, O. A. L., & Pérez-Díaz, M. (2021) · Health and Technology · doi:10.1007/s12553-021-00520-2 · Cited by 114
Nuclear Medicine and Artificial Intelligence: Best Practices for Algorithm Development
Bradshaw, T. J., Boellaard, R., Dutta, J., Jha, A. K., Jacobs, P., Li, Q., Liu, C., Sitek, A., Saboury, B., Scott, P. J. H., et al. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262567 · Cited by 94
“There are also valid concerns about the reproducibility of claims made in many published AI studies (2) and the generalizability of trained algorithms (3).”
BackgroundHadjiiski, L. M., Cha, K., Chan, H., Drukker, K., Morra, L., Näppi, J. J., Sahiner, B., Yoshida, H., Chen, Q., Deserno, T. M., et al. (2023) · Medical Physics · doi:10.1002/mp.16188 · Cited by 122
Explainability in medicine in an era of AI-based clinical decision support systems
Pierce, R. L., Van Biesen, W., Van Cauwenberge, D., Decruyenaere, J., & Sterckx, S. (2022) · Frontiers in Genetics · doi:10.3389/fgene.2022.903600 · Cited by 95
“(Zech et al., 2018).”
Artificial intelligence for pediatric ophthalmology
Reid, J. E., & Eaton, E. (2019) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000593 · Cited by 116
Deep Mining External Imperfect Data for Chest X-Ray Disease Screening
Luo, L., Yu, L., Chen, H., Liu, Q., Wang, X., Xu, J., & Heng, P. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3000949 · Cited by 104
“Previously, several works have been done on identifying the domain shift in the sense of different image distributions [13], [53], while few studies how to solve this problem in joint training.”
BackgroundMethodGradient Starvation: A Learning Proclivity in Neural Networks
Pezeshki, M., Kaba, S.-O., Bengio, Y., Courville, A. C., Precup, D., & Lajoie, G. (2021) · neural information processing systems · doi:10.48550/arxiv.2011.09468 · Cited by 187
Blake, N., Gaifulina, R., Griffin, L. D., Bell, I. M., & Thomas, G. M. H. (2022) · Diagnostics · doi:10.3390/diagnostics12061491 · Cited by 115
“Significant drops in ML model performances are well documented when a model is applied to data collected at another institute [56].”
Oakden-Rayner, L., Gale, W., Bonham, T. A., Lungren, M. P., Carneiro, G., Bradley, A. P., & Palmer, L. J. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00004-8 · Cited by 93
Jeong, J. J., Vey, B. L., Bhimireddy, A., Kim, T., Santos, T., Correa, R., Dutt, R., Mosunjac, M., Oprea-Ilies, G., Smith, G., et al. (2023) · Radiology Artificial Intelligence · doi:10.1148/ryai.220047 · Cited by 92
“Limited datasets lead to weak artificial intelligence models (11–13) that underperform with regard to patients not included in training data, leading to inadvertent systemic racial bias and health care disparities (14–17).”
BackgroundWhat Do Compressed Deep Neural Networks Forget?
Hooker, S., Courville, A. C., Clark, G., Dauphin, Y., & Frome, A. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1911.05248 · Cited by 84
“This can cause unexpected changes in model behavior in the wild that can compromise human welfare (Zech et al., 2018).”
BackgroundClinical Assessment of Deep Learning–based Super-Resolution for 3D Volumetric Brain MRI
Rudie, J. D., Gleason, T., Barkovich, M. J., Wilson, D. M., Shankaranarayanan, A., Zhang, T., Wang, L., Gong, E., Zaharchuk, G., & Villanueva-Meyer, J. E. (2022) · Radiology Artificial Intelligence · doi:10.1148/ryai.210059 · Cited by 91
“…been shown to improve image quality for a host of different structural MRI applications (7–9), it is important to determine whether they generalize beyond an individual scanner or practice setting, given that many AI algorithms have shown poorer performance when applied to exter-nal test sets (12).”
BackgroundVoter, A. F., Meram, E., Garrett, J. W., & Yu, J. J. (2021) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2021.03.005 · Cited by 104
Garcia Santa Cruz, B., Bossa, M. N., Sölter, J., & Husch, A. D. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102225 · Cited by 89
Tang, S., Ghorbani, A., Yamashita, R., Rehman, S., Dunnmon, J. A., Zou, J., & Rubin, D. L. (2021) · Scientific Reports · doi:10.1038/s41598-021-87762-2 · Cited by 76
Orlhac, F., Nioche, C., Klyuzhin, I. S., Rahmim, A., & Buvat, I. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.007 · Cited by 107
SSP: Early prediction of sepsis using fully connected LSTM-CNN model
Rafiei, A., Rezaee, A., Hajati, F., Gheisari, S., & Golzan, M. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104110 · Cited by 101
Reliance on metrics is a fundamental challenge for AI
Thomas, R. L., & Uminsky, D. (2022) · Patterns · doi:10.1016/j.patter.2022.100476 · Cited by 236
“tal-system-specific biases and are susceptible to worse performance on X-rays from hospitals outside their training set.(14) This toy example is clearly myopic in its focus on recall alone, rather than a broader slate of considerations.”
BackgroundAnalyzing Transfer Learning of Vision Transformers for Interpreting Chest Radiography
Usman, M., Zia, T., & Tariq, S. A. (2022) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-022-00666-z · Cited by 102
“CXRs can be used to identify diseases such as Tuberculosis [3], pneumonia [4], cancer [5], cardiomegaly [6], etc.”
MethodAssessing the Economic Value of Clinical Artificial Intelligence: Challenges and Opportunities
Hendrix, N., Veenstra, D. L., Cheng, M., Anderson, N. C., & Verguet, S. (2022) · Value in Health · doi:10.1016/j.jval.2021.08.015 · Cited by 83
Barragán-Montero, A., Bibal, A., Dastarac, M. H., Draguet, C., Valdés, G., Nguyen, D., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2022) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac678a · Cited by 84
“Another well-known example is the study by Zech et al ( 2018 ) , already discussed in section 2.2.1 ( fi gure 2 ) .”
BackgroundMethodInfluential2020 IEEE Symposium Series on Computational Intelligence (SSCI)
(2020) · doi:10.1109/ssci47803.2020 · Cited by 85
Sjoding, M. W., Taylor, D., Motyka, J., Lee, E., Co, I., Claar, D., McSparron, J. I., Ansari, S., Kerlin, M. P., Reilly, J. P., et al. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00056-x · Cited by 81
Eng, D. K., Khandwala, N. B., Long, J., Fefferman, N. R., Lala, S. V., Strubel, N. A., Milla, S. S., Filice, R. W., Sharp, S. E., Towbin, A. J., et al. (2021) · Radiology · doi:10.1148/radiol.2021204021 · Cited by 84
Tackling the Radiological Society of North America Pneumonia Detection Challenge
Pan, I., Cadrin-Chênevert, A., & Cheng, P. M. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.19.21512 · Cited by 91
Introduction to Artificial Intelligence and Machine Learning for Pathology
Harrison, J. H., Gilbertson, J. R., Hanna, M. G., Olson, N. H., Seheult, J. N., Sorace, J. M., & Stram, M. N. (2021) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2020-0541-cp · Cited by 82
“These receiver-operating characteristic (ROC) curves show that a model for radiologic diagnosis trained on mixed data from 2 sites performed well against mixed test data (solid line) but had lower performance against pure data from either site (dotted lines).(143) Changes in data over time (drifts, shifts) may reduce…”
BackgroundPreventing Failures Due to Dataset Shift: Learning Predictive Models That TransportPreprint
Subbaswamy, A., Schulam, P., & Saria, S. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1812.04597 · Cited by 106
“When evaluated beyond this initial dataset, say in the deployment environment, model performance may significantly deteriorate and potentially cause harm in safety-critical applications such as healthcare (see e.g., Schulam and Saria (2017); Zech et al. (2018)).”
BackgroundDeep learning applications in pulmonary medical imaging: recent updates and insights on COVID-19
Farhat, H. J., Sakr, G. E., & Kilany, R. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01101-5 · Cited by 93
“[183] aimed to test the performance of deep learning models with variable generalization.”
BackgroundBashyam, V., Doshi, J. J., Erus, G., Srinivasan, D., Abdulkadir, A., Singh, A., Habes, M., Yong Fan, A., Masters, C. L., Maruff, P. T., et al. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27908 · Cited by 99
“In the medical imaging domain, poor generalization presents a major limitation to the widespread clinical adoption of deep learningbased predictors.(5,6) Restrictions in generalizability are a common characteristic of modeling high dimensional data with many degrees of freedom, which can be overcome partially if suffi…”
BackgroundRahman, M. A., Victoros, E., Ernest, J., Davis, R., Shanjana, Y., & Islam, M. R. (2024) · Clinical Pathology · doi:10.1177/2632010x241226887 · Cited by 122
Deep Learning Approaches in Histopathology
Ahmed, A. A., Abouzid, M., & Kaczmarek, E. (2022) · Cancers · doi:10.3390/cancers14215264 · Cited by 101
“When a CNN-based model for the detection of pneumonia was trained using data provided by one institution and then tested separately using data from another two institutions, Zech et al. [93] found a significant difference in the performance ( p < 0.001).”
MethodInfluentialAIBx, Artificial Intelligence Model to Risk Stratify Thyroid Nodules
Thomas, J., & Haertling, T. (2020) · Thyroid · doi:10.1089/thy.2019.0752 · Cited by 84
The challenges of deploying artificial intelligence models in a rapidly evolving pandemic
Hu, Y., Jacob, J., Parker, G. J. M., Hawkes, D. J., Hurst, J. R., & Stoyanov, D. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-0185-2 · Cited by 78
Petersen, E., Potdevin, Y., Mohammadi, E., Zidowitz, S., Breyer, S., Nowotka, D., Henn, S., Pechmann, L., Leucker, M., Rostalski, P., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3178382 · Cited by 113
“…X-ray recording [10], poor generalization performance of a chest radiograph-based pneumonia detection system from one recording site to others [11], surgical skin markings influencing the decision-making of a system designed for melanoma recognition [12], improper performance evaluation…”
BackgroundDetecting and Remediating Harmful Data Shifts for the Responsible Deployment of Clinical AI Models
Subasri, V., Krishnan, A., Kore, A., Dhalla, A., Pandya, D., Wang, B., Malkin, D., Razak, F., Verma, A. A., Goldenberg, A., et al. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.13685 · Cited by 87
Integration of AI and traditional medicine in drug discovery
Khan, S. R., Rijjal, D. A., Piro, A., & Wheeler, M. B. (2021) · Drug Discovery Today · doi:10.1016/j.drudis.2021.01.008 · Cited by 91
Explaining deep neural networks for knowledge discovery in electrocardiogram analysis
Hicks, S. A., Isaksen, J. L., Thambawita, V., Ghouse, J., Ahlberg, G., Linneberg, A., Grarup, N., Strümke, I., Ellervik, C., Olesen, M. S., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-90285-5 · Cited by 77
Artificial intelligence: A promising frontier in bladder cancer diagnosis and outcome prediction
Borhani, S., Borhani, R., & Kajdacsy‐Balla, A. (2022) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2022.103601 · Cited by 89
Salvi, M., Seoni, S., Campagner, A., Gertych, A., Acharya, U. R., Molinari, F., & Cabitza, F. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2025.105846 · Cited by 118
London, A. J. (2022) · Cell Reports Medicine · doi:10.1016/j.xcrm.2022.100622 · Cited by 76
“26 Common clinical practices also create potential confounders such as when the sickest patients in a hospital are most likely to have radiographs taken from portable machines, or from a particular angle, allowing algorithms to improve their performance by conditioning on these arbitrary features…”
Lapins, S., Goitom, B., Kendall, J. M., Werner, M. J., Cashman, K. V., & Hammond, J. O. S. (2021) · Journal of Geophysical Research Solid Earth · doi:10.1029/2021jb021910 · Cited by 85
“However, as with practically any deep learning model, they can also suffer significant loss in performance when faced with data that differs in source or distribution from their training data (e.g., Barbedo, 2018; Zech et al., 2018, Figure 7).”
Zhan, C., Dai, Z., Yin, S., Carroll, K. C., & Soltanian, M. R. (2024) · Water Research · doi:10.1016/j.watres.2024.121679 · Cited by 77
Metadata
- Authors
- Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K.
- Affiliations
- California Pacific Medical Center (US)
- Verily Life Sciences LLC (United States) (US)
- Icahn School of Medicine at Mount Sinai (US)
- Corresponding author
- Oermann, Eric Karl
- ORCID
- Venue
- PLOS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-11-06
- Volume
- 15
- Issue
- 11
- Pages
- e1002683
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- PMC
- PMC6219764
- OpenAlex
- W2811374795
- Cited by
- 1,719
- References
- 34
- Citations by year
- 2026: 412 · 2025: 212 · 2024: 186 · 2023: 190 · 2022: 206 · 2021: 236 · 2020: 173 · 2019: 90 · 2018: 12
- FWCI
- 87.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Icahn School of Medicine at Mount Sinai
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- pneumonia detection, chest radiograph, convolutional neural networks, model generalization, external validation, computer-aided diagnosis, pneumonia screening, split-sample validation, radiographic findings, deep learning for medical imaging
- MeSH terms
- Deep Learning, Adult, Aged, Cross-Sectional Studies, Diagnosis, Computer-Assisted, Female, Humans, Male, Middle Aged, Pneumonia, Predictive Value of Tests, Radiographic Image Interpretation, Computer-Assisted, Radiology Information Systems, Retrospective Studies, Radiography, Thoracic, United States, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.