The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The study investigated the residual impact of eyeblinks on the electroencephalogram (EEG) after application of different correction procedures, namely a regression method (eye movement correction procedure, EMCP) and a component based method (Independent Component Analysis, ICA). METHODOLOGY/PRINCIPLE FINDINGS: Real and simulated data were investigated with respect to blink-related potentials and the residual mutual information of uncorrected vertical electrooculogram (EOG) and corrected EEG, which is a measure of residual EOG contribution to the EEG. The results reveal an occipital positivity that peaks at about 250 ms after the maximum blink excursion following application of either correction procedure. This positivity was not observable in the simulated data. Mutual information of vertical EOG and EEG depended on the applied regression procedure. In addition, different correction results were obtained for real and simulated data. ICA yielded almost perfect correction in all conditions. However, under certain conditions EMCP yielded comparable results to the ICA approach. CONCLUSION: In conclusion, for EMCP the quality of correction depended on the EMCP variant used and the structure of the data, whereas ICA always yielded almost perfect correction. However, its disadvantage is the much more complex data processing, and that it requires a suitable amount of data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055 · cited 9×
“In summary the mean mutual information of vertical (uncorrected) EOG and corrected EEG-channels was significant lower following application of extended infomax and EMCP w/s than after EMCPs (Figure 2).”
MethodInfluentialRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Independent Component Analysis: Principles and Practice
(2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511624148 · Cited by 1,917
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 1×
“These procedures are highly efficient in detecting linear trends and improbable data segments [29].”
Background
Cited by
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Diagnosis of Alzheimers Disease from EEG Signals: Where Are We Standing?
Dauwels, J., Vialatte, F., & Cichocki, A. (2010) · Current Alzheimer Research · doi:10.2174/156720510792231720 · Cited by 492
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372
Focus of attention modulates the heartbeat evoked potential
Petzschner, F. H., Weber, L. A., Wellstein, K. V., Paolini, G., Do, C. T., & Stephan, K. E. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.11.037 · Cited by 248
“One generally powerful method for artefact correction of EEG data is independent component analysis (ICA) (Debener, Thorne, Schneider, & Viola, 2010; Devuyst, Dutoit, Stenuit, Kerkhofs, & Stanus, 2008; Hoffmann & Falkenstein, 2008).”
Investigating Cooperative Behavior in Ecological Settings: An EEG Hyperscanning Study
Toppi, J., Borghini, G., Petti, M., He, E. J., De Giusti, V., He, B., Astolfi, L., & Babiloni, F. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154236 · Cited by 198
“Then, Independent Component Analysis (ICA) was applied in order to remove eyeblinks artifacts [37] and the EEG traces were segmented according to the flight phases.”
MethodVecchio, F., Miraglia, F., Marra, C., Quaranta, D., Vita, M. G., Bramanti, P., & Rossini, P. M. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-132087 · Cited by 182
“It has been proposed as an effective method for separating ocular movement and blink artifacts from EEG data [68–71].”
Intra- and Inter-Brain Synchronization during Musical Improvisation on the Guitar
Müller, V., Sänger, J., & Lindenberger, U. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073852 · Cited by 159
“As stated by Hoffmann and Falkenstein [31], regression-based eye correction methods (e.g., Gratton and Coles algorithm) provide comparable results to an independent component analysis (ICA) approach.”
MethodExpected reward modulates encoding-related theta activity before an event
Gruber, M. J., Watrous, A. J., Ekstrom, A. D., Ranganath, C., & Otten, L. J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.064 · Cited by 108
“Blinks and eye movements were removed via independent component analysis (Bell and Sejnowski, 1995; Delorme and Makeig, 2004), which has been shown to be an effective way to eliminate such artifacts from EEG (e.g. Hoffmann and Falkenstein, 2008).”
BackgroundMethodVecchio, F., Miraglia, F., Alù, F., Menna, M., Judica, E., Cotelli, M., & Rossini, P. M. (2020) · Journal of Alzheimer’s Disease · doi:10.3233/jad-200171 · Cited by 73
P300 Speller Performance Predictor Based on RSVP Multi-feature
Won, K., Kwon, M., Jang, S., Ahn, M., & Jun, S. C. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00261 · Cited by 34
“Then, artifacts such as eye blinks and eyeball movements were corrected with extended infomax independent component analysis (ICA) implemented in EEGLAB (Delorme and Makeig, 2004; Hoffmann and Falkenstein, 2008).”
Method
Metadata
- Authors
- Hoffmann, S., & Falkenstein, M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2008-08-20
- Volume
- 3
- Issue
- 8
- Pages
- e3004
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2146003031
- Cited by
- 261
- References
- 28
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.