Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“and also increase the information content of the data (e.g., in terms of reflecting the richness of the neural dynamics) [41, 42]”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
In the citing paper
“This efficiency increase can lead to substantially improved functional SNR (Feinberg et al., 2010; (Smith et al., 2011), the ability to acquire more diffusion data points (Sotiropoulos et al., 2013c), and/or increases in spatial resolution for fMRI or dMRI (Ugurbil et al. 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“The most significant pulse sequence development for the HCP was the implementation and optimization of slice-accelerated multiband (MB) acquisitions for fMRI and dMRI (Larkman et al., 2001; Moeller et al., 2008; Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Ugurbil et al., 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“Higher temporal resolution of the fMRI data can improve overall statistical sensitivity”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Self-citationFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Self-citationFunctional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Correspondence of the brain's functional architecture during activation and rest
Smith, S. M., Fox, P. T., Miller, K. L., Glahn, D. C., Fox, P. M., Mackay, C. E., Filippini, N., Watkins, K. E., Toro, R., Laird, A. R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905267106 · Cited by 5,150
Self-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Investigations into resting-state connectivity using independent component analysis
Beckmann, C. F., DeLuca, M., Devlin, J. T., & Smith, S. M. (2005) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2005.1634 · Cited by 3,398
Self-citationProbabilistic Independent Component Analysis for Functional Magnetic Resonance Imaging
Beckmann, C. F., & Smith, S. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.822821 · Cited by 2,715
Self-citationBayesian analysis of neuroimaging data in FSL
Woolrich, M. W., Jbabdi, S., Patenaude, B., Chappell, M., Makni, S., Behrens, T., Beckmann, C., Jenkinson, M., & Smith, S. M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.055 · Cited by 2,385
Self-citationMulti-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Principles of diffusion tensor imaging and its applications to basic neuroscience research
Mori, S., & Zhang, J. (2006) · Neuron · doi:10.1016/j.neuron.2006.08.012 · Cited by 1,708
Distinct patterns of brain activity in young carriers of the APOE -ε4 allele
Filippini, N., MacIntosh, B. J., Hough, M. G., Goodwin, G. M., Frisoni, G. B., Smith, S. M., Matthews, P. M., Beckmann, C. F., & Mackay, C. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811879106 · Cited by 1,613
Self-citationMoeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Self-citationCorrection for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
Diffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibers
Wedeen, V. J., Wang, R. P., Schmahmann, J. D., Benner, T., Tseng, W. Y. I., Dai, G., Pandya, D. N., Hagmann, P., D'Arceuil, H., & de Crespigny, A. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.036 · Cited by 941
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Physiological noise in oxygenation‐sensitive magnetic resonance imaging
Krüger, G., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1240 · Cited by 629
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<849::aid-mrm4>3.0.co;2-z · Cited by 576
High-field fMRI unveils orientation columns in humans
Yacoub, E., Harel, N., & Uğurbil, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804110105 · Cited by 566
Self-citationRetrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Self-citationMadore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Transmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421
Self-citation32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry
Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20925 · Cited by 375
Becerra, L. R., Breiter, H. C., Stojanovic, M., Fishman, S., Edwards, A., Comite, A. R., Gonzalez, R. G., & Borsook, D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199905)41:5<1044::aid-mrm25>3.0.co;2-m · Cited by 326
Diffusion magnetic resonance imaging: Its principle and applications
Mori, S., & Barker, P. B. (1999) · The Anatomical Record · doi:10.1002/(sici)1097-0185(19990615)257:3<102::aid-ar7>3.0.co;2-6 · Cited by 317
Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurements
Günther, M., Oshio, K., & Feinberg, D. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20580 · Cited by 293
Self-citationThree dimensional echo-planar imaging at 7 Tesla
Poser, B. A., Koopmans, P. J., Witzel, T., Wald, L. L., & Barth, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.108 · Cited by 284
Birn, R. M., Murphy, K., & Bandettini, P. A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20577 · Cited by 283
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
Self-citationUltrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252
Self-citationUltimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10597 · Cited by 238
Potential pitfalls of functional MRI using conventional gradient‐recalled echo techniques
Kim, S., Hendrich, K., Hu, X., Merkle, H., & Uǧurbil, K. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070111 · Cited by 224
Liu, G., Sobering, G., Duyn, J., & Moonen, C. T. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300617 · Cited by 205
Wiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans
Yacoub, E., Van De Moortele, P.-F., Shmuel, A., & Uğurbil, K. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.002 · Cited by 197
Self-citationHigh‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels
Hyde, J. S., Biswal, B. B., & Jesmanowicz, A. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1166 · Cited by 145
PRESTO-SENSE: An ultrafast whole-brain fMRI technique
Golay, X., Pruessmann, K. P., Weiger, M., Crelier, G. R., Folkers, P. J. M., Kollias, S., & Boesiger, P. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<779::aid-mrm1>3.0.co;2-4 · Cited by 120
Neggers, S. F. W., Hermans, E. J., & Ramsey, N. F. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1235 · Cited by 118
Wielopolski, P. A., Manning, W. J., & Edelman, R. R. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050406 · Cited by 105
Improved data reconstruction method for GRAPPA
Wang, Z., Wang, J., & Detre, J. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20601 · Cited by 105
Sodickson, D. K., Griswold, M. A., & Jakob, P. M. (1999) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00020-9 · Cited by 96
Simultaneous echo refocusing in EPI
Feinberg, D. A., Reese, T. G., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10227 · Cited by 90
Self-citationEfficient fat suppression by slice‐selection gradient reversal in twice‐refocused diffusion encoding
Nagy, Z., & Weiskopf, N. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21746 · Cited by 70
Does, M. D., & Gore, J. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<837::aid-mrm9>3.0.co;2-o · Cited by 66
Reese, T. G., Benner, T., Wang, R., Feinberg, D. A., & Wedeen, V. J. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21497 · Cited by 58
Self-citationFeinberg, D. A., & Jakab, P. D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160209 · Cited by 45
Self-citationA simple low‐SAR technique for chemical‐shift selection with high‐field spin‐echo imaging
Ivanov, D., Schäfer, A., Streicher, M., Heidemann, R. M., Trampel, R., & Turner, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22518 · Cited by 38
Fast algorithms for GS-model-based image reconstruction in data-sharing fourier imaging
Liang, Z., Madore, B., Glover, G. H., & Pelc, N. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815896 · Cited by 36
Rapid 3D radial multi-echo functional magnetic resonance imaging
Lee, G. R., Griswold, M. A., & Tkach, J. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.004 · Cited by 28
An echo-shifted gradient-echo MRI method for efficient diffusion weighting
Delalande, C., de Zwart, J. A., Trillaud, H., Grenier, N., & MOONEN, C. T. W. (1999) · Magnetic Resonance in Medicine · Cited by 20
Mansfield, P., Harvey, P. R., & Stehling, M. K. (1994) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01705255 · Cited by 16
Heßelmann, V., Girnus, R., Wedekind, C., Hunsche, S., Bunke, J., Schulte, O., Sorger, B., Lasek, K., Krug, B., Sturm, V., et al. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20101 · Cited by 8
Larkman (2001) · doi:10.1002/1522-2586(200102)13:2<313::aid-jmri1045>3.0.co;2-w
Cited by
The WU-Minn Human Connectome Project: An overview
Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E. J., Yacoub, E., & Ugurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.041 · Cited by 5,651
Self-citationMethods to detect, characterize, and remove motion artifact in resting state fMRI
Power, J. D., Mitra, A., Laumann, T. O., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.048 · Cited by 3,748
Dynamic functional connectivity: Promise, issues, and interpretations
Hutchison, R. M., Womelsdorf, T., Allen, E. A., Bandettini, P. A., Calhoun, V. D., Corbetta, M., Della Penna, S., Duyn, J. H., Glover, G. H., Gonzalez-Castillo, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.079 · Cited by 2,962
The Human Connectome Project: A data acquisition perspective
Van Essen, D. C., Ugurbil, K., Auerbach, E., Barch, D., Behrens, T. E. J., Bucholz, R., Chang, A., Chen, L., Corbetta, M., Curtiss, S. W., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.018 · Cited by 2,680
Self-citationWhite matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Metadata
- Authors
- Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E.
- Affiliations
- University of California, San Francisco (US)
- University of Minnesota (US)
- John Radcliffe Hospital (GB)
- Advanced MRI Technologies (United States) (US)
- Washington University in St. Louis (US)
- Corresponding author
- Feinberg, David A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-12-20
- Volume
- 5
- Issue
- 12
- Pages
- e15710
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3004955
- OpenAlex
- W2114809469
- Cited by
- 1,296
- References
- 57
- Citations by year
- 2026: 51 · 2025: 73 · 2024: 53 · 2023: 63 · 2022: 88 · 2021: 104 · 2020: 94 · 2019: 94 · 2018: 107 · 2017: 117 · 2016: 98 · 2015: 102 · 2014: 75 · 2013: 99 · 2012: 48
- FWCI
- 44.96
- Type
- journal article
- Language
- en
- Update notices
- correction (2011-09-28)
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (P30 NS057091, 1U54MH091657, 9907842)
- W. M. Keck Foundation
- National Institutes of Health (5u54mh091657-05, S10 RR1395, 1u54mh091657-01, 1U54‐MH‐091657, RR08079)
- National Institute of Mental Health (1U54-MH091657-01, U54-MH091657)
- National Institute of Neurological Disorders and Stroke (R44NS063537, R44NS073417, P30NS057091)
- National Institute of Biomedical Imaging and Bioengineering (R01EB000331)
- National Center for Research Resources (S10-RR1395, P41RR001395, P41RR008079, P41RR08079)
- NIH Blueprint for Neuroscience Research (1U54-MH-091657)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- echo planar imaging, whole-brain fMRI, scan time reduction, spatial multiplexing, time-division multiplexing, high angular resolution diffusion imaging, diffusion MRI, fat suppression, signal-to-noise ratio, resting-state networks, independent component analysis, temporal resolution, non-stationarity
- MeSH terms
- Algorithms, Brain, Brain Mapping, Diffusion, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Models, Biological, Neurons, Regression Analysis, Echo-Planar Imaging, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.