Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“and also increase the information content of the data (e.g., in terms of reflecting the richness of the neural dynamics) [41, 42]”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
In the citing paper
“This efficiency increase can lead to substantially improved functional SNR (Feinberg et al., 2010; (Smith et al., 2011), the ability to acquire more diffusion data points (Sotiropoulos et al., 2013c), and/or increases in spatial resolution for fMRI or dMRI (Ugurbil et al. 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“The most significant pulse sequence development for the HCP was the implementation and optimization of slice-accelerated multiband (MB) acquisitions for fMRI and dMRI (Larkman et al., 2001; Moeller et al., 2008; Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Ugurbil et al., 2013).”
From The WU-Minn Human Connectome Project: An overview (2013) · cites this paper as Feinberg et al., 2010
In the citing paper
“Higher temporal resolution of the fMRI data can improve overall statistical sensitivity”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 2×
“Analysis was carried out using FSL (FMRIB’s Software Library) [51,52].”
MethodSelf-citationFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 1×
“The mean (over time) image was brain-extracted using BET [54].”
MethodSelf-citationFunctional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205 · cited 2×
“Multi-acquisition RSN analysis RSNs and structured artifacts in the data were identified using MELODIC (Multivariate Exploratory Linear Optimized Decomposition into Independent Components [55], FSL’s implementation of ICA (Independent Component Analysis [56]).”
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 5×
“Echo train shortening achieved by reducing the phase encoding steps by factor R using partial parallel acquisition techniques such as SENSE [11] or GRAPPA [10] and their derivatives, which is referred to as acceleration, or the use of partial Fourier sampling [9] can also be incorporated in this sequence and were empl…”
BackgroundMethodInfluentialCorrespondence of the brain's functional architecture during activation and rest
Smith, S. M., Fox, P. T., Miller, K. L., Glahn, D. C., Fox, P. M., Mackay, C. E., Filippini, N., Watkins, K. E., Toro, R., Laird, A. R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905267106 · Cited by 5,150 · cited 1×
“In addition to carrying out the high-dimensional analyses, we also used a set of 10 spatial maps from another study ([33]; 10 RSNs from 36 subjects) as the dual regression input maps.”
MethodSelf-citationDynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
BackgroundOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681 · cited 1×
“[1,2] and diffusion weighted imaging for neuronal fiber tracto-”
Background
Cited by
The WU-Minn Human Connectome Project: An overview
Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E. J., Yacoub, E., & Ugurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.041 · Cited by 5,651
Self-citationMethods to detect, characterize, and remove motion artifact in resting state fMRI
Power, J. D., Mitra, A., Laumann, T. O., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.048 · Cited by 3,748
“With advances such as short-TE or multi-band sequences (Bright and Murphy, 2013; Feinberg et al., 2010), future datasets will hopefully containwithin themselves powerfulmeans of artifact avoidance and removal.”
BackgroundDynamic functional connectivity: Promise, issues, and interpretations
Hutchison, R. M., Womelsdorf, T., Allen, E. A., Bandettini, P. A., Calhoun, V. D., Corbetta, M., Della Penna, S., Duyn, J. H., Glover, G. H., Gonzalez-Castillo, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.079 · Cited by 2,962
“There have been recent advances in MR pulse sequences and image reconstruction, such as multiband imaging (Larkman et al., 2001; Moeller et al., 2010; Feinberg et al., 2010), MR encephalography (MREG; Hennig et al.”
MethodThe Human Connectome Project: A data acquisition perspective
Van Essen, D. C., Ugurbil, K., Auerbach, E., Barch, D., Behrens, T. E. J., Bucholz, R., Chang, A., Chen, L., Corbetta, M., Curtiss, S. W., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.018 · Cited by 2,680
“These can be combined into Multiplexed EPI (Feinberg et al., 2010).”
BackgroundMethodSelf-citationWhite matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
“Moreover, recent developments such asmultiplexing (Feinberg et al., 2010; Reese et al., 2009) and compressed sensing Donoho et al.”
BackgroundMultimodal population brain imaging in the UK Biobank prospective epidemiological study
Miller, K. L., Alfaro-Almagro, F., Bangerter, N. K., Thomas, D. L., Yacoub, E., Xu, J., Bartsch, A. J., Jbabdi, S., Sotiropoulos, S. N., Andersson, J. L. R., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4393 · Cited by 2,020
“While this might not provide statistical certainty for a diagnosis or interventional recommendation, it should allow for single-patient imaging to be used in a similar way to current state-of-the-art patient-tuned genetic testing.”
Self-citationSatterthwaite, T. D., Elliott, M. A., Gerraty, R. T., Ruparel, K., Loughead, J., Calkins, M. E., Eickhoff, S. B., Hakonarson, H., Gur, R. C., Gur, R. E., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.052 · Cited by 1,881
“Eighth and fi nally, as fast TR acquisitions become more common (Feinberg et al., 2010), slice timing correction may be avoided, perhaps allowing the effects of motion to be better isolated to the volumes in which motion occurs.”
BackgroundSalimi-Khorshidi, G., Douaud, G., Beckmann, C. F., Glasser, M. F., Griffanti, L., & Smith, S. M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.046 · Cited by 1,770
“Inanassociatedpaper(Griffantietal.,submittedforpublication),we have evaluated in detail the effect of ICA + FIX fMRI cleanup on both standard fMRI datasets and accelerated (Feinberg et al., 2010; Moeller et al., 2010) datasets.”
BackgroundSelf-citationFunction in the human connectome: task-fMRI and individual differences in behavior
Barch, D. M., Burgess, G. C., Harms, M. P., Petersen, S. E., Schlaggar, B. L., Corbetta, M., Glasser, M. F., Curtiss, S., Dixit, S., Feldt, C., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.033 · Cited by 1,529
“0 mm isotropic voxels, with a multi-band acceleration factor of 8 (Feinberg et al., 2010; Moeller et al., 2010).”
BackgroundSelf-citationResting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
“Early HCP piloting utilised a combination of two accelerations — the multiband method described above, and “simultaneous image refocused” (SIR) (Feinberg et al., 2002), the combined technique being referred to as “multiplexed” EPI (Feinberg et al., 2010).”
BackgroundMethodResultInfluentialSelf-citationClosed-loop brain training: the science of neurofeedback
Sitaram, R., Ros, T., Stoeckel, L., Haller, S., Scharnowski, F., Lewis-Peacock, J., Weiskopf, N., Blefari, M. L., Rana, M., Oblak, E., et al. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2016.164 · Cited by 1,306
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
“Parallel imaging based methods have recently been combined with the SER method to extend the number of simultaneous slices (18,19) and this approach has been recently explored for fMRI and diffusion applications (19).”
BackgroundMethodGriffanti, L., Salimi-Khorshidi, G., Beckmann, C. F., Auerbach, E. J., Douaud, G., Sexton, C. E., Zsoldos, E., Ebmeier, K. P., Filippini, N., Mackay, C. E., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.034 · Cited by 1,262
“…for all subjects: R – 3D high-resolution T1-weighted MR images were acquired using a MEMPRAGE sequence (TR = 2530 ms, TE = 1.79/3.65/5.51/7.37 ms, (Feinberg et al., 2010; Moeller et al., 267 2010; Setsompop et al., 2012; Xu et al., 2013); The same pre-processing was performed on both Standard…”
BackgroundMethodInfluentialSelf-citationThe Human Connectome Project's neuroimaging approach
Glasser, M. F., Smith, S. M., Marcus, D. S., Andersson, J. L. R., Auerbach, E. J., Behrens, T. E. J., Coalson, T. S., Harms, M. P., Jenkinson, M., Moeller, S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4361 · Cited by 1,090
“High-temporal-resolution fMRI data (i.e., TR 1 s) facilitates more selective and effective artifact removal 7,8 and improves statistical efficiency, particularly for multivariate statistics 50 .”
BackgroundSelf-citationCiric, R., Wolf, D. H., Power, J. D., Roalf, D. R., Baum, G. L., Ruparel, K., Shinohara, R. T., Elliott, M. A., Eickhoff, S. B., Davatzikos, C., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.020 · Cited by 1,042
“, 2016) and multiband acquisition (Feinberg et al., 2010).”
BackgroundInfluentialFunctional connectomics from resting-state fMRI
Smith, S. M., Vidaurre, D., Beckmann, C. F., Glasser, M. F., Jenkinson, M., Miller, K. L., Nichols, T. E., Robinson, E. C., Salimi-Khorshidi, G., Woolrich, M. W., et al. (2013) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2013.09.016 · Cited by 952
Self-citationReconstructing Visual Experiences from Brain Activity Evoked by Natural Movies
Nishimoto, S., Vu, A. T., Naselaris, T., Benjamini, Y., Yu, B., & Gallant, J. L. (2011) · Current Biology · doi:10.1016/j.cub.2011.08.031 · Cited by 933
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
“Amajor feature of the acquisition protocol involves acceleration using simultaneousmulti-slice echo planar imaging (EPI) withmultiband (MB) excitation and multiple receivers (Feinberg et al., 2010; Larkman et al., 2001; Moeller et al., 2010; Setsompop et al., 2012).”
MethodSelf-citationThe NKI-Rockland Sample: A Model for Accelerating the Pace of Discovery Science in Psychiatry
Nooner, K. B., Colcombe, S. J., Tobe, R. H., Mennes, M., Benedict, M. M., Moreno, A. L., Panek, L. J., Brown, S., Zavitz, S. T., Li, Q., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00152 · Cited by 806
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
“Using this method to accelerate whole brain coverage, we demonstrated (Feinberg et al., 2010) that the statistical significance of the Resting State Networks (RSNs) detected by high dimensional ICA analysis from rfMRI time series significantly improved (Fig.”
MethodInfluentialSelf-citationGraph analysis of the human connectome: Promise, progress, and pitfalls
Fornito, A., Zalesky, A., & Breakspear, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.087 · Cited by 743
“In other cases, it has been found wanting (Bohland, et al., 2012).”
Andreu-Perez, J., Poon, C. C. Y., Merrifield, R. D., Wong, S. T. C., & Yang, G.-Z. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2450362 · Cited by 670
Informatics and Data Mining Tools and Strategies for the Human Connectome Project
Marcus, D. S., Harwell, J., Olsen, T., Hodge, M., Glasser, M. F., Prior, F., Jenkinson, M., Laumann, T., Curtiss, S. W., & Van Essen, D. C. (2011) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2011.00004 · Cited by 689
“Data retrieved from the database will then be processed as needed and sent to the viewer.”
BackgroundMethodSelf-citationZuo, X.-N., & Xing, X.-X. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2014.05.009 · Cited by 660
Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S. J., Evans, J. W., Luh, W.-M., & Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 615
“, 2006) and multislice excitation (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2011) should allow for substantial increases in resolution and efficiency.”
BackgroundInfluentialTractography: Where Do We Go from Here?
Jbabdi, S., & Johansen-Berg, H. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0033 · Cited by 614
“New developments in accelerated sequences (Feinberg et al., 2010) are likely to provide an order of magnitude increase in the amount of data we can acquire in a given time window.”
Mapping the human brain's cortical-subcortical functional network organization
Ji, J. L., Spronk, M., Kulkarni, K., Repovš, G., Anticevic, A., & Cole, M. W. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.006 · Cited by 585
Harms, M. P., Somerville, L. H., Ances, B. M., Andersson, J., Barch, D. M., Bastiani, M., Bookheimer, S. Y., Brown, T. B., Buckner, R. L., Burgess, G. C., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.060 · Cited by 584
“…readout time, which in turn (1) significantly reduces SNR and (2) limits the achievable slice acceleration factor, thereby resulting in longer TRs, which has implications for the robustness of certain denoising algorithms and multivariate-style analyses (Feinberg et al., 2010; Smith et al., 2013a).”
InfluentialSelf-citationPros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
“(Feinberg et al., 2010; Setsompop et al., 2012) This combined method has been commonly referred to as Multiplexed EPI.”
MethodSimultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
“Although an earlier abstract had demonstrated the combination of EPI with SMS (14), it was the subsequent publications of highly accelerated EPI images by Moeller et al (15), (initially in abstract form (16), who also introduced the term “multiband”) and Feinberg et al (17) that drew widespread attention to this techn…”
BackgroundMethodInfluentialMethods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“…protocols are adopted, such as MR-inverse imaging (Hennig et al., 2007; Kiviniemi et al., 2016; Lin et al., 2012) and simultaneous multislice (SMS) EPI (Feinberg et al., 2010; Moeller et al., 2010) (but see Scheel et al. (2014) for the need of physiological noise regression in SMS EPI data).”
InfluentialEvaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
“Certainly, the most straightforward application is to acquire a time series with a higher rate of sampling, which we have shown improves the statistical significance of resting state networks (RSNs) (Feinberg et al., 2010), or to enable novel analysis methods, as we recently demonstrated with the use of temporal ICA t…”
InfluentialSelf-citationZuo, X.-N., Xu, T., Jiang, L., Yang, Z., Cao, X.-Y., He, Y., Zang, Y.-F., Castellanos, F. X., & Milham, M. P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.017 · Cited by 505
“, 1997), especially for recently developed fast imaging sequences (Feinberg et al., 2010; Moeller et al., 2010; Smith et al., 2012).”
BackgroundGuell, X., Gabrieli, J. D. E., & Schmahmann, J. D. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.082 · Cited by 460
“EPI data acquired by the WU-Minn HCP used multi-band pulse sequences (Moeller et al., 2010; Feinberg et al., 2010; Setsompop et al., 2012; Xu et al., 2012).”
MethodFunctional gradients of the cerebellum
Guell, X., Schmahmann, J. D., Gabrieli, J. D., & Ghosh, S. S. (2018) · eLife · doi:10.7554/elife.36652 · Cited by 472
Real-time fMRI neurofeedback: Progress and challenges
Sulzer, J., Haller, S., Scharnowski, F., Weiskopf, N., Birbaumer, N., Blefari, M. L., Bruehl, A. B., Cohen, L. G., deCharms, R. C., Gassert, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.033 · Cited by 453
“Although whole brain fMRI data sampling can now be performed in around half a second (Feinberg et al., 2010), typical protocols still use sampling rates covering the brain approximately every two seconds.”
BackgroundUltra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
“Yet as shown in functional connectivity research [12,59],”
BackgroundInfluentialSelf-citationYan, C.-G., Craddock, R. C., Zuo, X.-N., Zang, Y.-F., & Milham, M. P. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.081 · Cited by 440
“Acquisition-related variations Scanner make and model (Friedman and Glover, 2006b), sequence vs. conventional acquisition (Feinberg et al., 2010; Lin et al., 2005) of repetitions, flip angle, echo time, and acquisition volume (field o 2.”
Imaging human connectomes at the macroscale
Craddock, R. C., Jbabdi, S., Yan, C.-G., Vogelstein, J. T., Castellanos, F. X., Di Martino, A., Kelly, C., Heberlein, K., Colcombe, S., & Milham, M. P. (2013) · Nature Methods · doi:10.1038/nmeth.2482 · Cited by 419
Altered functional and structural brain network organization in autism
Rudie, J. D., Brown, J. A., Beck-Pancer, D., Hernandez, L. M., Dennis, E. L., Thompson, P. M., Bookheimer, S. Y., & Dapretto, M. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2012.11.006 · Cited by 411
“Future studies may also benefit from advances in imaging acquisition (Feinberg et al., 2010), more flexible modeling approaches (Smith et al., 2012), and large-scale studies involving collaboration between institutions (Biswal et al., 2010).”
BackgroundIntegrated strategy for improving functional connectivity mapping using multiecho fMRI
Kundu, P., Brenowitz, N. D., Voon, V., Worbe, Y., Vértes, P. E., Inati, S. J., Saad, Z. S., Bandettini, P. A., & Bullmore, E. T. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301725110 · Cited by 399
“Single-echo multiband imaging may allow also denoising and tSNR increases with better resolution (19, 20).”
BackgroundResting-State Functional MR Imaging: A New Window to the Brain
Barkhof, F., Haller, S., & Rombouts, S. A. R. B. (2014) · Radiology · doi:10.1148/radiol.14132388 · Cited by 373
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
“Feinberg et al introduced a multiplexed method that adds a third approach to these two in which a few adjacent slices are excited with slight delays, so that the data from all three slices are measured in a longer data readout window [26].”
MethodDonahue, C. J., Sotiropoulos, S. N., Jbabdi, S., Hernandez-Fernandez, M., Behrens, T. E., Dyrby, T. B., Coalson, T., Kennedy, H., Knoblauch, K., Van Essen, D. C., et al. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.0493-16.2016 · Cited by 380
“The quality of postmortem dMRI imaging data used here surpasses typical spatial and angular resolutions used in conventional in vivo dMRI, though recent advances such as multiband acceleration (Feinberg et al., 2010; Setsompop et al., 2012) can reduce this gap (Sotiropoulos et al.”
BackgroundSelf-citationBabayan, A., Erbey, M., Kumral, D., Reinelt, J. D., Reiter, A. M. F., Röbbig, J., Schaare, H. L., Uhlig, M., Anwander, A., Bazin, P.-L., et al. (2019) · Scientific Data · doi:10.1038/sdata.2018.308 · Cited by 364
Chen, N.-K., Guidon, A., Chang, H.-C., & Song, A. W. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.038 · Cited by 364
“It should be noted that the multiplexed sensitivity encoding method is a pure postprocessing procedure, without requiring hardware or pulse sequence modification, and is different from the recently developed multiplexed EPI pulse sequence (Feinberg et al. (2010)).”
MethodAlves, P. N., Foulon, C., Karolis, V., Bzdok, D., Margulies, D. S., Volle, E., & Thiebaut de Schotten, M. (2019) · Communications Biology · doi:10.1038/s42003-019-0611-3 · Cited by 357
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
“Further reduction in acquisition time can be achieved by increasing the slice acceleration factor and/or by combining parallel imaging simultaneous multi-slice method with the SIR technique as shown in Feinberg et al. (2010); Setsompop et al. (2010).”
BackgroundMethodThe future of fMRI connectivity
Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.022 · Cited by 355
“Indeed, resting and task-FMRI at 7 T is already seeing spectacular gains in spatial resolution and/or effective SNR. Additionally, several groups are producing exciting new work on accelerated FMRI, with the ability to achieve sub-second whole-brain imaging (Feinberg et al., 2010).”
BackgroundMethodInfluentialSelf-citationThe Human Connectome Project: A retrospective
Elam, J. S., Glasser, M. F., Harms, M. P., Sotiropoulos, S. N., Andersson, J. L. R., Burgess, G. C., Curtiss, S. W., Oostenveld, R., Larson-Prior, L. J., Schoffelen, J.-M., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118543 · Cited by 307
Self-citationMulti-echo fMRI: A review of applications in fMRI denoising and analysis of BOLD signals
Kundu, P., Voon, V., Balchandani, P., Lombardo, M. V., Poser, B. A., & Bandettini, P. A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.033 · Cited by 321
q-Space Deep Learning: Twelve-Fold Shorter and Model-Free Diffusion MRI Scans
Golkov, V., Dosovitskiy, A., Sperl, J. I., Menzel, M. I., Czisch, M., Samann, P., Brox, T., & Cremers, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2551324 · Cited by 310
Cheung, V. K. M., Harrison, P. M. C., Meyer, L., Pearce, M. T., Haynes, J.-D., & Koelsch, S. (2019) · Current Biology · doi:10.1016/j.cub.2019.09.067 · Cited by 298
In vivo histology of the myelin g-ratio with magnetic resonance imaging
Stikov, N., Campbell, J. S. W., Stroh, T., Lavelée, M., Frey, S., Novek, J., Nuara, S., Ho, M.-K., Bedell, B. J., Dougherty, R. F., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.023 · Cited by 295
A Hitchhiker's Guide to Functional Magnetic Resonance Imaging
Soares, J. M., Magalhães, R., Moreira, P. S., Sousa, A., Ganz, E., Sampaio, A., Alves, V., Marques, P., & Sousa, N. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00515 · Cited by 272
“…Structural equation modeling analysis GLM Flex http://mrtools.mgh.harvard.edu/ Statistical analysis Granger Multivariate Autoregressive Connectivity (GMAC; Tana et al., 2012) https://www.nitrc.org/projects/gmac_2012/ Preprocessing, analysis (Granger causality mapping)”
MethodTwenty years of functional MRI: The science and the stories
Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.026 · Cited by 265
“These include: work describing the challenge of performing fMRI auditory experiments in the loud scanning environment (Talavage et al., 1999) by Tom Talavage (2012), correction of geometric distortions associated with EPI (Jezzard and Balaban, 1995) by Peter Jezzard (2012), the development and use of EPI by two of its…”
InfluentialConsciousness in humans and non-human animals: recent advances and future directions
Boly, M., Seth, A. K., Wilke, M., Ingmundson, P., Baars, B., Laureys, S., Edelman, D. B., & Tsuchiya, N. (2013) · Frontiers in Psychology · doi:10.3389/fpsyg.2013.00625 · Cited by 291
Wu, G.-R., Liao, W., Stramaglia, S., Ding, J.-R., Chen, H., & Marinazzo, D. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.01.003 · Cited by 284
“Two data sets with different TR (TR=1.4s and TR=0.645s) were acquired on Siemens 3T Trio Tim scanners using developed multiplexed echo planar imaging (Feinberg et al., 2010).”
MethodPsychoradiology: The Frontier of Neuroimaging in Psychiatry
Lui, S., Zhou, X. J., Sweeney, J. A., & Gong, Q. (2016) · Radiology · doi:10.1148/radiol.2016152149 · Cited by 272
Recent advances in parallel imaging for MRI
Hamilton, J., Franson, D., & Seiberlich, N. (2017) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2017.04.002 · Cited by 251
A 64‐channel 3T array coil for accelerated brain MRI
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260
“Similar to the regular parallel imaging techniques, the smaller elements sizes and its increased loop count of the 64-channel coil provide a stronger spatial distinction of the sensitivity profiles, which permit a better separation of the simultaneously exited slices (19,26,20).”
Bachtiar, V., Near, J., Johansen-Berg, H., & Stagg, C. J. (2015) · eLife · doi:10.7554/elife.08789 · Cited by 250
Interslice leakage artifact reduction technique for simultaneous multislice acquisitions
Cauley, S. F., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24898 · Cited by 255
“Parallel imaging methods that incorporate SER have also been introduced for fMRI and diffusion applications [12, 13].”
Satterthwaite, T. D., Wolf, D. H., Ruparel, K., Erus, G., Elliott, M. A., Eickhoff, S. B., Gennatas, E. D., Jackson, C., Prabhakaran, K., Smith, A., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.045 · Cited by 253
“Fifth, the increasing availability of multiplex EPI acquisitions with sub-second TR (Feinberg et al., 2010) may allow for better control of motion artifact by preventing the aliasing of higher-frequency motion-related signals into lower frequencies that provide greater contributions to functional…”
BackgroundBehrens, T. E., & Sporns, O. (2012) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2011.08.005 · Cited by 237
MGH–USC Human Connectome Project datasets with ultra-high b-value diffusion MRI
Fan, Q., Witzel, T., Nummenmaa, A., Van Dijk, K. R. A., Van Horn, J. D., Drews, M. K., Somerville, L. H., Sheridan, M. A., Santillana, R. M., Snyder, J., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.075 · Cited by 254
Functional Magnetic Resonance Imaging Methods
Chen, J. E., & Glover, G. H. (2015) · Neuropsychology Review · doi:10.1007/s11065-015-9294-9 · Cited by 212
“2002) and simultaneous multiple slices (SMS) (Feinberg et al. 2010; Setsompop et al. 2012) can change these tradeoffs by reducing the amount of data that need to be acquired and thereby increasing scan efficiency.”
BackgroundInfluentialModelling with independent components
Beckmann, C. F. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.020 · Cited by 235
“Recent advances in MR sequence development (Feinberg et al., 2010)”
BackgroundYeo, B. T. T., Krienen, F. M., Chee, M. W. L., & Buckner, R. L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.046 · Cited by 242
“1 ms, FA = 52°, 2 × 2 × 2 mm voxels, FOV = 208 × 180 mm, and 72 oblique axial slices alternated between phase encoding in a right to left direction in one run and phase encoding in a left to right direction in the other run (Feinberg et al., 2010; Moeller et al., 2010; Setsompop et al., 2012; Xu et al., 2012).”
Imaging structural and functional brain networks in temporal lobe epilepsy
Bernhardt, B. C., Hong, S., Bernasconi, A., & Bernasconi, N. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00624 · Cited by 237
“…directly measure neural activity, but only activity-dependent hemodynamic alterations, and has a relatively low temporal resolution in the range of 1–2 s [but see Feinberg et al. (2010); Smith et al. (2012), for a recent example of increasing the temporal resolution in functional MRI acquisitions].”
BackgroundQuantitative mapping of the per‐axon diffusion coefficients in brain white matter
Kaden, E., Kruggel, F., & Alexander, D. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25734 · Cited by 234
Wave‐CAIPI for highly accelerated 3D imaging
Bilgic, B., Gagoski, B. A., Cauley, S. F., Fan, A. P., Polimeni, J. R., Grant, P. E., Wald, L. L., & Setsompop, K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25347 · Cited by 231
“x m1⁄2x; y ; z e i2pkx=N [6]”
Prospective representation of navigational goals in the human hippocampus
Brown, T. I., Carr, V. A., LaRocque, K. F., Favila, S. E., Gordon, A. M., Bowles, B., Bailenson, J. N., & Wagner, A. D. (2016) · Science · doi:10.1126/science.aaf0784 · Cited by 233
Spatially constrained hierarchical parcellation of the brain with resting-state fMRI
Blumensath, T., Jbabdi, S., Glasser, M. F., Van Essen, D. C., Ugurbil, K., Behrens, T. E. J., & Smith, S. M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.024 · Cited by 232
“During each session, six 10-min fMRI datasets were acquired from each subject using the accelerated protocol described in Feinberg et al. (2010), providing whole brain coverage at a TR of 0.8 s and with an isotropic spatial resolution of 3 mm. Datawas acquired on a 3 T scanner (Siemens Trio).”
MethodInfluentialSelf-citationParallel distributed networks dissociate episodic and social functions within the individual
DiNicola, L. M., Braga, R. M., & Buckner, R. L. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00529.2019 · Cited by 217
Physiological Noise in Brainstem fMRI
Brooks, J. C. W., Faull, O. K., Pattinson, K. T. S., & Jenkinson, M. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00623 · Cited by 222
High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project
Vu, A. T., Auerbach, E., Lenglet, C., Moeller, S., Sotiropoulos, S. N., Jbabdi, S., Andersson, J., Yacoub, E., & Ugurbil, K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.004 · Cited by 218
“…the success of multiband (MB) acceleration (Larkman et al., 2001; Moeller et al., 2010; Setsompop et al., 2012) applied to dMRI at 3 T in the HCP (Feinberg et al., 2010; Setsompop et al., 2013; Sotiropoulos et al., 2013b; Ugurbil et al., 2013), there have been recent efforts to exploit MB…”
Self-citationAssessment of system dysfunction in the brain through MRI-based connectomics
Filippi, M., van den Heuvel, M. P., Fornito, A., He, Y., Hulshoff Pol, H. E., Agosta, F., Comi, G., & Rocca, M. A. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70144-3 · Cited by 215
Burgess, G. C., Kandala, S., Nolan, D., Laumann, T. O., Power, J. D., Adeyemo, B., Harms, M. P., Petersen, S. E., & Barch, D. M. (2016) · Brain Connectivity · doi:10.1089/brain.2016.0435 · Cited by 216
“Whole-brain EPI acquisitions were acquired on the 3T Siemens Connectome scanner: 32-channel head coil, TR = 720 msec, TE = 33.1msec, in-plane FOV = 208 · 180 mm, 72 slices, 2.0 mm isotropic voxels, and multi-band acceleration factor of 8 (Feinberg et al., 2010).”
InfluentialFunctional Integration Between Brain Regions at Rest Occurs in Multiple-Frequency Bands
Gohel, S. R., & Biswal, B. B. (2015) · Brain Connectivity · doi:10.1089/brain.2013.0210 · Cited by 213
“Recent advancements in data acquisition sequences and multiband imaging techniques (Feinberg et al., 2010; Feinberg and Yacoub, 2012; Jesmanowicz et al., 2011) have enabled whole-brain fMRI scanning at subsecond temporal resolution.”
BackgroundFunctional specialization within the inferior parietal lobes across cognitive domains
Numssen, O., Bzdok, D., & Hartwigsen, G. (2021) · eLife · doi:10.7554/elife.63591 · Cited by 185
Seth, A. K., Chorley, P., & Barnett, L. C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.049 · Cited by 198
BOLD5000, a public fMRI dataset while viewing 5000 visual images
Chang, N., Pyles, J. A., Marcus, A., Gupta, A., Tarr, M. J., & Aminoff, E. M. (2019) · Scientific Data · doi:10.1038/s41597-019-0052-3 · Cited by 159
“Functional Images and Fieldmaps: Functional images were collected using a T2*-weighted gradient recalled echo echoplanar imaging multi-band pulse sequence (cmrr_mbep2d_bold) from the University of Minnesota Center for Magnetic Resonance Research (CMRR) [24, 25].”
MethodFast fMRI can detect oscillatory neural activity in humans
Lewis, L. D., Setsompop, K., Rosen, B. R., & Polimeni, J. R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608117113 · Cited by 189
The future of the human connectome
Van Essen, D. C., & Ugurbil, K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.032 · Cited by 192
“It has already been shown to significantly increase the statistical power in functional connectivity analyses (Feinberg et al., 2010) and reduce the acquisition time of diffusion data; therefore, it has become the core sequence design for both HCP consortia.”
BackgroundMethodInfluentialAdvances in MRI-based computational neuroanatomy: from morphometry to in-vivo histology
Weiskopf, N., Mohammadi, S., Lutti, A., & Callaghan, M. F. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000222 · Cited by 191
Extreme Learning Machine-Based Classification of ADHD Using Brain Structural MRI Data
Peng, X., Lin, P., Zhang, T., & Wang, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079476 · Cited by 194
“Several studies using structural MRI have demonstrated anatomical differences be-tween ADHD and normal children [23–25].”
BackgroundBastiani, M., Shah, N. J., Goebel, R., & Roebroeck, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.002 · Cited by 192
“In addition, this computational cost will increase more than linearly with increase in spatial resolution of the DWI data as MR hardware and sequences advance (e.g. Feinberg et al., 2010; Heidemann et al., 2010).”
BackgroundSotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24623 · Cited by 186
“Whole brain DW images were acquired with a 32-channel head coil (Siemens) using a multiband echo planar imaging sequence with simultaneous multislice excitation (9,10,12) and a Stejskal-Tanner (i.”
MethodSelf-citationLiao, X.-H., Xia, M.-R., Xu, T., Dai, Z.-J., Cao, X.-Y., Niu, H.-J., Zuo, X.-N., Zang, Y.-F., & He, Y. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.058 · Cited by 187
“Nonetheless , the signal-to-noise ratio of the images might also be reduced due to the short acquisition time of each volume (Feinberg et al., 2010).”
BackgroundMethodInfluentialNoninvasive mapping of water diffusional exchange in the human brain using filter‐exchange imaging
Nilsson, M., Lätt, J., van Westen, D., Brockstedt, S., Lasič, S., Ståhlberg, F., & Topgaard, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24395 · Cited by 188
“Acceleration techniques (43) and filtering of large slabs with subsequent slice-selective detection could further increase the volume coverage per unit time.”
MethodDeery, H. A., Di Paolo, R., Moran, C., Egan, G. F., & Jamadar, S. D. (2023) · Psychophysiology · doi:10.1111/psyp.14159 · Cited by 166
“…connectivity, as it provides exquisite spatial resolution with moderate temporal resolution (sub-second resolution is now obtainable with fast imaging techniques like multiband acquisition; Feinberg et al., 2010, Feinberg & Setsompop, 2013; see Risk et al., 2021 for resting-state multiband fMRI).”
BackgroundMassively parallel MRI detector arrays
Keil, B., & Wald, L. L. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.001 · Cited by 175
“Finally we note that at some point, if all the elements are coupled enough to give identical profiles, parallel MRI reconstructions will become highly ill-conditioned; i.e. the sensitivity patterns contain less distinct spatial information than the uncoupled coils would.”
InfluentialMagnetic Resonance Imaging at Ultrahigh Fields
Ugurbil, K. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2313619 · Cited by 171
“to improve the statistical significance of the resulting RSNs detected [150], [157]; in the HCP, this was further confirmed, resulting in previously unobtainable number of independent and”
BackgroundTodd, N., Moeller, S., Auerbach, E. J., Yacoub, E., Flandin, G., & Weiskopf, N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.056 · Cited by 173
“…have used amultiband 2D EPI sequence for functionalMRI (fMRI) studies to demonstrate that the faster scan time can improve statistical power (Feinberg et al., 2010; Smith et al., 2013) and better sample signal fluctuations due to physiology (Tong and Frederick, 2014; Tong et al., 2014).”
MethodSelf-citationBOLD fractional contribution to resting-state functional connectivity above 0.1 Hz
Chen, J. E., & Glover, G. H. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.012 · Cited by 173
“Recent advances in MR techniques have allowed the examination of brain FC at faster temporal scales with improved signal to noise ratio (SNR) (Feinberg et al., 2010; Hennig et al., 2007; Larkman et al., 2001; Lin et al., 2006; Moeller et al., 2010; Zahneisen et al., 2011), and emerging evidence has…”
BackgroundImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“In the HCP, initially we combined the MB/SMS sequence we developed with the SIR approach (Gunther and Feinberg, 2005) for achieving greater acceleration, which we called Multiplexed EPI (Feinberg et al., 2010; Ugurbil et al., 2013); we used this sequence to demonstrate that increasing temporal sampling in a fMRI time…”
MethodInfluentialSetsompop, K., Fan, Q., Stockmann, J., Bilgic, B., Huang, S., Cauley, S. F., Nummenmaa, A., Wang, F., Rathi, Y., Witzel, T., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26653 · Cited by 177
Bingham–NODDI: Mapping anisotropic orientation dispersion of neurites using diffusion MRI
Tariq, M., Schneider, T., Alexander, D. C., Gandini Wheeler-Kingshott, C. A., & Zhang, H. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.046 · Cited by 169
“Obtaining a very high orientation sampling is not yet clinically feasible with existing imaging sequences, but emerging technologies such as multi-band imaging (Feinberg et al., 2010) will make it possible to acquire more data per unit time, enabling higher orientation sampling in the same acquisition time.”
Background
Metadata
- Authors
- Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E.
- Affiliations
- University of California, San Francisco (US)
- University of Minnesota (US)
- John Radcliffe Hospital (GB)
- Advanced MRI Technologies (United States) (US)
- Washington University in St. Louis (US)
- Corresponding author
- Feinberg, David A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-12-20
- Volume
- 5
- Issue
- 12
- Pages
- e15710
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3004955
- OpenAlex
- W2114809469
- Cited by
- 1,296
- References
- 57
- Citations by year
- 2026: 51 · 2025: 73 · 2024: 53 · 2023: 63 · 2022: 88 · 2021: 104 · 2020: 94 · 2019: 94 · 2018: 107 · 2017: 117 · 2016: 98 · 2015: 102 · 2014: 75 · 2013: 99 · 2012: 48
- FWCI
- 44.96
- Type
- journal article
- Language
- en
- Update notices
- correction (2011-09-28)
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (P30 NS057091, 1U54MH091657, 9907842)
- W. M. Keck Foundation
- National Institutes of Health (5u54mh091657-05, S10 RR1395, 1u54mh091657-01, 1U54‐MH‐091657, RR08079)
- National Institute of Mental Health (1U54-MH091657-01, U54-MH091657)
- National Institute of Neurological Disorders and Stroke (R44NS063537, R44NS073417, P30NS057091)
- National Institute of Biomedical Imaging and Bioengineering (R01EB000331)
- National Center for Research Resources (S10-RR1395, P41RR001395, P41RR008079, P41RR08079)
- NIH Blueprint for Neuroscience Research (1U54-MH-091657)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- echo planar imaging, whole-brain fMRI, scan time reduction, spatial multiplexing, time-division multiplexing, high angular resolution diffusion imaging, diffusion MRI, fat suppression, signal-to-noise ratio, resting-state networks, independent component analysis, temporal resolution, non-stationarity
- MeSH terms
- Algorithms, Brain, Brain Mapping, Diffusion, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Models, Biological, Neurons, Regression Analysis, Echo-Planar Imaging, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.