CoChat

Evaluation of Brain Iron Content Based on Magnetic Resonance Imaging (MRI): Comparison among Phase Value, R2* and Magnitude Signal Intensity

Open access
Yan, Shen-Qiang, Sun, Jian-Zhong, Yan, Yu-Qing, Wang, He, Lou, Min · 2012 · PLoS ONE
Cited by 35

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND PURPOSE: Several magnetic resonance imaging (MRI) techniques are being exploited to measure brain iron levels increasingly as iron deposition has been implicated in some neurodegenerative diseases. However, there remains no unified evaluation of these methods as postmortem measurement isn't commonly available as the reference standard. The purpose of this study was to make a comparison among these methods and try to find a new index of brain iron. METHODS: We measured both phase values and R2* in twenty-four adults, and performed correlation analysis among the two methods and the previously published iron concentrations. We also proposed a new method using magnitude signal intensity and compared it with R2* and brain iron. RESULTS: We found phase value correlated with R2* in substantia nigra (r = -0.723, p<0.001) and putamen (r = -0.514, p = 0.010), while no correlations in red nucleus (r = -0.236, p = 0.268) and globus pallidus (r = -0.111, p = 0.605). And the new magnitude method had significant correlations in red nucleus (r = -0.593, p = 0.002), substantia nigra (r = -0.521, p = 0.009), globus pallidus (r = -0.750, p<0.001) and putamen (r = -0.547, p = 0.006) with R2*. A strong inverse correlation was also found between the new magnitude method and previously published iron concentrations in seven brain regions (r = -0.982, P<0.001). CONCLUSIONS: Our study indicates that phase value may not be used for assessing the iron content in some brain regions especially globus pallidus. The new magnitude method is highly consistent with R2* especially in globus pallidus, and we assume that this approach may be acceptable as an index of iron content in iron-rich brain regions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0031748

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 35

Metadata

Authors
Yan, S.-Q., Sun, J.-Z., Yan, Y.-Q., Wang, H., & Lou, M.
Venue
PLoS ONE
Published
2012-02-20
Volume
7
Issue
2
Pages
e31748
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2031474123
Cited by
35
References
10
FWCI
3.78
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Brain Iron Content Based on Magnetic Resonance Imaging (MRI): Comparison among Phase Value, R2* and Magnitude Signal Intensity. https://app.cochat.ai/papers/10.1371/journal.pone.0031748
The paper
Yan, S.-Q., Sun, J.-Z., Yan, Y.-Q., Wang, H., & Lou, M. (2012). Evaluation of Brain Iron Content Based on Magnetic Resonance Imaging (MRI): Comparison among Phase Value, R2* and Magnitude Signal Intensity. PLoS ONE. https://doi.org/10.1371/journal.pone.0031748

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.