CoChat

A Method for Removal of Low Frequency Components Associated with Head Movements from Dual-Axis Swallowing Accelerometry Signals

Open access
Sejdić, Ervin, Steele, Catriona M., Chau, Tom · 2012 · PLoS ONE
Cited by 33

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Head movements can greatly affect swallowing accelerometry signals. In this paper, we implement a spline-based approach to remove low frequency components associated with these motions. Our approach was tested using both synthetic and real data. Synthetic signals were used to perform a comparative analysis of the spline-based approach with other similar techniques. Real data, obtained data from 408 healthy participants during various swallowing tasks, was used to analyze the processing accuracy with and without the spline-based head motions removal scheme. Specifically, we analyzed the segmentation accuracy and the effects of the scheme on statistical properties of these signals, as measured by the scaling analysis. The results of the numerical analysis showed that the spline-based technique achieves a superior performance in comparison to other existing techniques. Additionally, when applied to real data, we improved the accuracy of the segmentation process by achieving a 27% drop in the number of false negatives and a 30% drop in the number of false positives. Furthermore, the anthropometric trends in the statistical properties of these signals remained unaltered as shown by the scaling analysis, but the strength of statistical persistence was significantly reduced. These results clearly indicate that any future medical devices based on swallowing accelerometry signals should remove head motions from these signals in order to increase segmentation accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0033464

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 31

  1. NP Reddy, 1990, Biomechanical measurements to characterize the oral phase of dysphagia., IEEE Transactions on Biomedical Engineering, 37, 392, 10.1109/10.52346 · DOI · Paper page
  2. NP Reddy, 1991, Noninvasive accelaration measurements to characterize the pharyngeal phase of swallowing., Journal of Biomedical Engineering, 13, 379, 10.1016/0141-5425(91)90018-3 · DOI · Paper page
  3. NP Reddy, 1988, Biomechanical quantification for assessment and diagnosis of dysphagia., IEEE Engineering in Medicine and Biology Magazine, 7, 16, 10.1109/51.7929 · DOI
  4. O Ekberg, 2002, Social and psychological burden of dysphagia: Its impact on diagnosis and treatment., Dysphagia, 17, 139, 10.1007/s00455-001-0113-5 · DOI · Paper page
  5. C Steele, 2007, Dysphagia service delivery by speech-language pathologists in Canada: results of a national survey., Canadian Journal of Speech-Language Pathology and Audiology, 31, 166
  6. DJC Ramsey, 2006, Can pulse oximetry or a bedside swallowing assessment be used to detect aspiration after stroke?, Stroke, 37, 2984, 10.1161/01.STR.0000248758.32627.3b · DOI
  7. R Ishida, 2002, Hyoid motion during swallowing: Factors affecting forward and upward displacement., Dysphagia, 17, 262, 10.1007/s00455-002-0064-5 · DOI · Paper page
  8. Y Kim, 2008, Maximum hyoid displacement in normal swallowing., Dysphagia, 23, 274, 10.1007/s00455-007-9135-y · DOI · Paper page
  9. J Lee, 2008, Time and time-frequency characterization of dual-axis swallowing accelerometry signals., Physiological Measurement, 29, 1105, 10.1088/0967-3334/29/9/008 · DOI · Paper page
  10. J Lee, 2006, A radial basis classifier for the automatic detection of aspiration in children with dysphagia., Journal of NeuroEngineering and Rehabilitation, 3
  11. T Chau, 2005, Investigating the stationarity of paediatric aspiration signals., IEEE Transactions on Neural Systems and Rehabilitation Engineering, 13, 99, 10.1109/TNSRE.2004.841384 · DOI · Paper page
  12. A Das, 2001, Hybrid fuzzy logic committee neural networks for recognition of swallow acceleration signals., Computer Methods and Programs in Biomedicine, 64, 87, 10.1016/S0169-2607(00)00099-7 · DOI
  13. NP Reddy, 2000, Measurements of acceleration during videouorographic evaluation of dysphagic patients., Medical Engineering and Physics, 22, 405, 10.1016/S1350-4533(00)00047-3 · DOI · Paper page
  14. E Sejdić, 2011, Scaling analysis of baseline dual-axis cervical accelerometry signals., Computer Methods and Programs in Biomedicine, 103, 113, 10.1016/j.cmpb.2010.06.010 · DOI
  15. E Sejdić, 2010, Understanding statistical persistence of dual-axis swallowing accelerometry signals., Computers in Biology and Medicine, 40, 839, 10.1016/j.compbiomed.2010.09.002 · DOI
  16. D Hung, 2009, Extraction of average neck exion angle during swallowing in neutral and chin-tuck positions., BioMedical Engineering OnLine, 8, 25, 10.1186/1475-925X-8-25 · doi:10.1186/1475-925x-8-25
  17. E Sejdić, 2010, A procedure for denoising dual-axis swallowing accelerometry signals., Physiological Measurement, 31, N1, 10.1088/0967-3334/31/1/N01 · DOI · Paper page
  18. E Sejdić, 2010, Vocalization removal for improved automatic segmentation of dual-axis swallowing accelerometry signals., Medical Engineering and Physics, 32, 668, 10.1016/j.medengphy.2010.04.008 · DOI
  19. M Unser, 1991, Fast B-spline transforms for continuous image representation and interpolation., IEEE Transactions on Pattern Analysis and Machine Intelligence, 13, 277, 10.1109/34.75515 · DOI
  20. M Unser, 1993, B-spline signal processing: Part I - theory., IEEE Transactions on Signal Processing, 41, 821, 10.1109/78.193220 · DOI · Paper page
  21. M Unser, 1999, Splines: a perfect fit for signal and image processing., IEEE Signal Processing Magazine, 16, 22, 10.1109/79.799930 · DOI · Paper page
  22. M Unser, 2002, Splines: a perfect fit for medical imaging., 10.1117/12.467162 · doi:10.1117/12.467162
  23. M Unser, 1993, B-spline signal processing: Part II - efficiency design and applications., IEEE Transactions on Signal Processing, 41, 834, 10.1109/78.193221 · DOI · Paper page
  24. M Karczewicz, 1997, ECG data compression by spline approximation., Signal Processing, 59, 43, 10.1016/S0165-1684(97)00037-6 · doi:10.1016/s0165-1684(97)00037-6
  25. M Unser, 1992, Polynomial spline signal approximations: filter design and asymptotic equivalence with Shannon's sampling theorem., IEEE Transactions on Information Theory, 38, 95, 10.1109/18.108253 · DOI
  26. E Sejdić, 2010, The effects of head movement on dual-axis cervical accelerom- etry signals., BMC Research Notes, 3, 269, 10.1186/1756-0500-3-269 · DOI · Paper page
  27. H Liang, 2005, Application of the empirical mode decomposition to the analysis of esophageal manometric data in gastroesophageal reux disease., IEEE Transactions on Biomedical Engineering, 52, 1692, 10.1109/TBME.2005.855719 · DOI · Paper page
  28. MP Tarvainen, 2002, An advanced detrending method with application to HRV analysis., IEEE Transactions on Biomedical Engineering, 49, 172, 10.1109/10.979357 · DOI · Paper page
  29. A Ghaffari, 2009, Parallel processing of ECG and blood pressure waveforms for detection of acute hypotensive episodes: a simulation study using a risk scoring model., Computer Methods in Biomechanics and Biomedical Engineering
  30. HB Mann, 1947, On a test of whether one of two random variables is stochastically larger than the other., The Annals of Mathematical Statistics, 18, 50, 10.1214/aoms/1177730491 · DOI · Paper page
  31. WH Kruskal, 1952, Use of ranks in one-criterion analysis of variance., Journal of the American Statistical Association, 47, 583, 10.1080/01621459.1952.10483441 · DOI · Paper page

Cited by

See all 33

Metadata

Authors
Sejdić, E., Steele, C. M., & Chau, T.
Venue
PLoS ONE
Published
2012-03-29
Volume
7
Issue
3
Pages
e33464
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1981638466
Cited by
33
References
3
FWCI
7.88
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Method for Removal of Low Frequency Components Associated with Head Movements from Dual-Axis Swallowing Accelerometry Signals. https://app.cochat.ai/papers/10.1371/journal.pone.0033464
The paper
Sejdić, E., Steele, C. M., & Chau, T. (2012). A Method for Removal of Low Frequency Components Associated with Head Movements from Dual-Axis Swallowing Accelerometry Signals. PLoS ONE. https://doi.org/10.1371/journal.pone.0033464

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.