Increased Anatomical Specificity of Neuromodulation via Modulated Focused Ultrasound
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Transcranial ultrasound can alter brain function transiently and nondestructively, offering a new tool to study brain function now and inform future therapies. Previous research on neuromodulation implemented pulsed low-frequency (250-700 kHz) ultrasound with spatial peak temporal average intensities (ISPTA) of 0.1-10 W/cm(2). That work used transducers that either insonified relatively large volumes of mouse brain (several mL) with relatively low-frequency ultrasound and produced bilateral motor responses, or relatively small volumes of brain (on the order of 0.06 mL) with relatively high-frequency ultrasound that produced unilateral motor responses. This study seeks to increase anatomical specificity to neuromodulation with modulated focused ultrasound (mFU). Here, 'modulated' means modifying a focused 2-MHz carrier signal dynamically with a 500-kHz signal as in vibro-acoustography, thereby creating a low-frequency but small volume (approximately 0.015 mL) source of neuromodulation. Application of transcranial mFU to lightly anesthetized mice produced various motor movements with high spatial selectivity (on the order of 1 mm) that scaled with the temporal average ultrasound intensity. Alone, mFU and focused ultrasound (FUS) each induced motor activity, including unilateral motions, though anatomical location and type of motion varied. Future work should include larger animal models to determine the relative efficacy of mFU versus FUS. Other studies should determine the biophysical processes through which they act. Also of interest is exploration of the potential research and clinical applications for targeted, transcranial neuromodulation created by modulated focused ultrasound, especially mFU's ability to produce compact sources of ultrasound at the very low frequencies (10-100s of Hertz) that are commensurate with the natural frequencies of the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Therapeutic application of repetitive transcranial magnetic stimulation: a review
Wassermann, E. M., & Lisanby, S. H. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00585-5 · Cited by 601 · cited 1×
“TMS works well on shallow anatomical brain structures and within relatively large volumes of tissue [22,23].”
BackgroundThe Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“Linear activation of neural tissue may be a key advantage of ultrasound stimulation, as non-linear activation of the peripheral nervous system, for example, has limited the clinical utility of functional electrical stimulation [16,17].”
Background
Cited by
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Transcranial focused ultrasound stimulation of human primary visual cortex
Lee, W., Kim, H.-C., Jung, Y., Chung, Y. A., Song, I.-U., Lee, J.-H., & Yoo, S.-S. (2016) · Scientific Reports · doi:10.1038/srep34026 · Cited by 415
Ultrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353
Neuromodulation with single‐element transcranial focused ultrasound in human thalamus
Legon, W., Ai, L., Bansal, P., & Mueller, J. K. (2018) · Human Brain Mapping · doi:10.1002/hbm.23981 · Cited by 334
Non-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Ultrasonic Neuromodulation Causes Widespread Cortical Activation via an Indirect Auditory Mechanism
Sato, T., Shapiro, M. G., & Tsao, D. Y. (2018) · Neuron · doi:10.1016/j.neuron.2018.05.009 · Cited by 329
Transcranial focused ultrasound neuromodulation of the human primary motor cortex
Legon, W., Bansal, P., Tyshynsky, R., Ai, L., & Mueller, J. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-28320-1 · Cited by 328
Focused Ultrasound-mediated Non-invasive Brain Stimulation: Examination of Sonication Parameters
Kim, H., Chiu, A., Lee, S. D., Fischer, K., & Yoo, S.-S. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.06.011 · Cited by 304
Ultrasound Produces Extensive Brain Activation via a Cochlear Pathway
Guo, H., Hamilton, M., Offutt, S. J., Gloeckner, C. D., Li, T., Kim, Y., Legon, W., Alford, J. K., & Lim, H. H. (2018) · Neuron · doi:10.1016/j.neuron.2018.04.036 · Cited by 291
Ultrasonic Neuromodulation via Astrocytic TRPA1
Oh, S.-J., Lee, J. M., Kim, H.-B., Lee, J., Han, S., Bae, J. Y., Hong, G.-S., Koh, W., Kwon, J., Hwang, E.-S., et al. (2019) · Current Biology · doi:10.1016/j.cub.2019.08.021 · Cited by 249
“Thus, we first stimulated the motor cortex in vivo of wild-type (WT) and TRPA1 knockout (KO) mice by transcranial LILFU (Figure S1) and checked the tail movement score (Figure 1A; Video S1) as previously described [31].”
MethodNeuromodulation with transcranial focused ultrasound
Kubanek, J. (2018) · Neurosurgical Focus · doi:10.3171/2017.11.focus17621 · Cited by 195
“13,17, 22,34 35, 38, 56”
Focused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
A review of low-intensity focused ultrasound for neuromodulation
Baek, H., Pahk, K. J., & Kim, H. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0007-y · Cited by 184
Activation of Piezo1 but Not NaV1.2 Channels by Ultrasound at 43 MHz
Prieto, M. L., Firouzi, K., Khuri-Yakub, B. T., & Maduke, M. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.12.020 · Cited by 178
Mahoney, J. J., Hanlon, C. A., Marshalek, P. J., Rezai, A. R., & Krinke, L. (2020) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2020.117149 · Cited by 121
Lee, J.-H., Cho, I.-J., Ko, K., Yoon, E.-S., Park, H.-H., & Kim, T. S. (2017) · Microsystem Technologies · doi:10.1007/s00542-016-2912-5 · Cited by 68
Metadata
- Authors
- Mehić, E., Xu, J. M., Caler, C. J., Coulson, N. K., Moritz, C. T., & Mourad, P. D.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-02-04
- Volume
- 9
- Issue
- 2
- Pages
- e86939
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2003984876
- Cited by
- 174
- References
- 2
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.