The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Thermal Transport Characteristics of Human Skin Measured In Vivo Using Ultrathin Conformal Arrays of Thermal Sensors and Actuators
Open accessAbstract
Measurements of the thermal transport properties of the skin can reveal changes in physical and chemical states of relevance to dermatological health, skin structure and activity, thermoregulation and other aspects of human physiology. Existing methods for in vivo evaluations demand complex systems for laser heating and infrared thermography, or they require rigid, invasive probes; neither can apply to arbitrary regions of the body, offers modes for rapid spatial mapping, or enables continuous monitoring outside of laboratory settings. Here we describe human clinical studies using mechanically soft arrays of thermal actuators and sensors that laminate onto the skin to provide rapid, quantitative in vivo determination of both the thermal conductivity and thermal diffusivity, in a completely non-invasive manner. Comprehensive analysis of measurements on six different body locations of each of twenty-five human subjects reveal systematic variations and directional anisotropies in the characteristics, with correlations to the thicknesses of the epidermis (EP) and stratum corneum (SC) determined by optical coherence tomography, and to the water content assessed by electrical impedance based measurements. Multivariate statistical analysis establishes four distinct locations across the body that exhibit different physical properties: heel, cheek, palm, and wrist/volar forearm/dorsal forearm. The data also demonstrate that thermal transport correlates negatively with SC and EP thickness and positively with water content, with a strength of correlation that varies from region to region, e.g., stronger in the palmar than in the follicular regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Specifically, these skin-like thermal actuators can be used for prosthetic applications,[106,502] AR/VR feedback thermal stimulators,[191,503,504] and thermal therapy in rehabilitation.[505–507]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [502]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Endowing e-skins with”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [502]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 21,232
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationHighly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · cited 1×
“Here, we introduce strategies that exploit ultrathin, soft systems [9–18] of thermal actuators and sensors for robust, precise transport measurements, in a non-invasive manner that can rapidly capture both orientation and position dependent characteristics.”
MethodAn ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Gustafsson, S. E. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142087 · Cited by 1,480 · cited 1×
“The effective depth associated with the measurement can be approximated as [20] Dp 1⁄4 ffiffiffiffiffiffiffiffiffi atmax p ð2Þ”
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389 · cited 1×
“Here, we introduce strategies that exploit ultrathin, soft systems [9–18] of thermal actuators and sensors for robust, precise transport measurements, in a non-invasive manner that can rapidly capture both orientation and position dependent characteristics.”
MethodUltrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229 · cited 1×
“Our recent report [10] introduced a type of thermal sensor with thickness, modulus and thermal mass matched to the epidermis, for spatiotemporal mapping of temperature on the surface of the skin with precision equal to or better than that of state-of-the-art infrared thermography systems.”
BackgroundSelf-citationEgawa, M., Hirao, T., & Takahashi, M. (2007) · Acta Dermato-Venereologica · doi:10.2340/00015555-0183 · Cited by 336 · cited 1×
“OCT yielded accurate values of SC thickness for the palm and heel pad but not for the follicular regions, where previous studies indicate a typical value of ~15 μm [21–23].”
ResultStretchability of thin metal films on elastomer substrates
Li, T., Huang, Z., Suo, Z., Lacour, S. P., & Wagner, S. (2004) · Applied Physics Letters · doi:10.1063/1.1806275 · Cited by 315 · cited 1×
“Here, we introduce strategies that exploit ultrathin, soft systems [9–18] of thermal actuators and sensors for robust, precise transport measurements, in a non-invasive manner that can rapidly capture both orientation and position dependent characteristics.”
Method
Cited by
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
“stratum corneum thickness, and skin hydration level.(44) A modified version of this device has”
BackgroundMethodFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
“Examples include precision measurement of temperature and thermal transport characteristics ( 14 , 15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic…”
Self-citationInkjet-Printed Graphene/PEDOT:PSS Temperature Sensors on a Skin-Conformable Polyurethane Substrate
Vuorinen, T., Niittynen, J., Kankkunen, T., Kraft, T. M., & Mäntysalo, M. (2016) · Scientific Reports · doi:10.1038/srep35289 · Cited by 335
Self-citationAdvanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Metadata
- Authors
- Webb, R. C., Pielak, R. M., Bastien, P., Ayers, J., Niittynen, J., Kurniawan, J., Manco, M., Lin, A., Cho, N. H., Malyrchuk, V., Balooch, G., & Rogers, J. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- L'Oreal (United States) (US)
- L'Oréal (France) (FR)
- Tampere University of Technology (FI)
- Corresponding author
- Balooch, Guive
- Rogers, John A.
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-02-06
- Volume
- 10
- Issue
- 2
- Pages
- e0118131
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4319855
- OpenAlex
- W2034602349
- Semantic Scholar
- f4d4409a4f6983736a7639803d8181edb397ae6a
- Cited by
- 98
- References
- 23
- Citations by year
- 2026: 4 · 2025: 14 · 2024: 8 · 2023: 6 · 2022: 7 · 2021: 11 · 2020: 11 · 2019: 5 · 2018: 15 · 2017: 7 · 2016: 7 · 2015: 3
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Science Foundation (1144245, DGE‐1 144 245)
- L'Oreal USA
- Tekes
- University of Illinois at Urbana-Champaign (DGE-1144245)
- Division of Materials Research
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- thermal transport properties, in vivo skin measurement, thermal actuators, anisotropy, epidermal thickness, stratum corneum thickness, skin hydration, body region variation, thermoregulation
- MeSH terms
- Algorithms, Humans, Models, Theoretical, Regional Blood Flow, Skin Physiological Phenomena, Temperature, Thermosensing, Thermal Conductivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal Transport Characteristics of Human Skin Measured In Vivo Using Ultrathin Conformal Arrays of Thermal Sensors and Actuators. https://app.cochat.ai/papers/10.1371/journal.pone.0118131
- The paper
- Webb, R. C., Pielak, R. M., Bastien, P., Ayers, J., Niittynen, J., Kurniawan, J., Manco, M., Lin, A., Cho, N. H., Malyrchuk, V., Balooch, G., & Rogers, J. A. (2015). Thermal Transport Characteristics of Human Skin Measured In Vivo Using Ultrathin Conformal Arrays of Thermal Sensors and Actuators. PLOS ONE. https://doi.org/10.1371/journal.pone.0118131
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.