The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Digital PCR Modeling for Maximal Sensitivity, Dynamic Range and Measurement Precision
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This measurement uncertainty could be due to pipetting errors or variations in droplet or partition volume, which have a strong influence on platform sensitivity53,55,56.”
From Comparing the precision of two digital PCR applications for copy number comparisons in protists (2025) · cites this paper as [56]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770 · cited 1×
“Of interest to the investigator utilizing digital PCR techniques [1] are precision, dynamic range, and sensitivity of their digital PCR system.”
MethodHuggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859 · cited 1×
“The MIQE guidelines for digital PCR derive these equations using the number of positive partitions [4].”
Method
Research works printed but not linked: 4
- K Mather, 1949, The Analysis of Extinction Time Data in Bioassay, Biometrics, 5, 127, 10.2307/3001915 · DOI
- NR Beer, 2008, On-chip Single-copy Real-time Reverse-transcription PCR in Isolated Picoliter Droplets, Analytical Chemistry, 80, 1854, 10.1021/ac800048k · DOI · Paper page
- L Mazutis, 2009, Droplet-Based Microfluidic Systems for High-Throughput Single DNA Molecule Isothermal Amplification and Analysis, Analytical Chemistry, 81, 4813, 10.1021/ac900403z · DOI · Paper page
- LB Pinheiro, 2012, Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification, Analytical Chemistry, 84, 1003, 10.1021/ac202578x · DOI · Paper page
Cited by
Hart, O. E., & Halden, R. U. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138875 · Cited by 556
Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications
Cao, L., Cui, X., Hu, J., Li, Z., Choi, J. R., Yang, Q., Lin, M., Ying Hui, L., & Xu, F. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.082 · Cited by 291
Digital PCR: From early developments to its future application in clinics
Trouchet, A., Gines, G., Benhaim, L., & Taly, V. (2025) · Lab on a Chip · doi:10.1039/d5lc00055f · Cited by 43
Comparing the precision of two digital PCR applications for copy number comparisons in protists
Gross, M., Stoeck, T., Mauvisseau, Q., Schrøder-Nielsen, A., & Dunthorn, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-13143-8 · Cited by 6
Metadata
- Authors
- Majumdar, N., Wessel, T., & Marks, J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-03-25
- Volume
- 10
- Issue
- 3
- Pages
- e0118833
- ISSN
- 1932-6203
- Cited by
- 119
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digital PCR Modeling for Maximal Sensitivity, Dynamic Range and Measurement Precision. https://app.cochat.ai/papers/10.1371/journal.pone.0118833
- The paper
- Majumdar, N., Wessel, T., & Marks, J. (2015). Digital PCR Modeling for Maximal Sensitivity, Dynamic Range and Measurement Precision. PLOS ONE. https://doi.org/10.1371/journal.pone.0118833
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.