CoChat

Superresolution and Fluorescence Dynamics Evidence Reveal That Intact Liposomes Do Not Cross the Human Skin Barrier

Open access

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

In this study we use the combination of super resolution optical microscopy and raster image correlation spectroscopy (RICS) to study the mechanism of action of liposomes as transdermal drug delivery systems in human skin. Two different compositions of liposomes were applied to newly excised human skin, a POPC liposome and a more flexible liposome containing the surfactant sodium cholate. Stimulated emission depletion microscopy (STED) images of intact skin and cryo-sections of skin treated with labeled liposomes were recorded displaying an optical resolution low enough to resolve the 100 nm liposomes in the skin. The images revealed that virtually none of the liposomes remained intact beneath the skin surface. RICS two color cross correlation diffusion measurements of double labeled liposomes confirmed these observations. Our results suggest that the liposomes do not act as carriers that transport their cargo directly through the skin barrier, but mainly burst and fuse with the outer lipid layers of the stratum corneum. It was also found that the flexible liposomes showed a greater delivery of the fluorophore into the stratum corneum, indicating that they functioned as chemical permeability enhancers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0146514

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Cartoon depicting the sample preparation. Samples were labeled non-occlusively. Intact skin samples for imaging were mounted SC side down on a microscope cover glass for imaging. Samples for cryo sectioning were sectioned and mounted as depicted.
Fig 1 Cartoon depicting the sample preparation. Samples were labeled non-occlusively. Intact skin samples for imaging were mounted SC side down on a microscope cover glass for imaging. Samples for cryo sectioning were sectioned and mounted as depicted.CC BY · PubMed Central
Fig 2 Cryo frozen and sectioned skin labelled with the free dye, Atto-488-DPPE, in PBS buffer. A) A STED image of the sample in which the SC is clearly visible, as the bright u-shaped layer in the center of the image; the width of the lipid layers in the SC are measured to approximately 100–120 nm. A line scan across the marked line is shown in B, and the individual lipid layers are recognizable. C) A confocal cross section (XZ plane) through a skin section. The slice is orientated with the SC to the left. Only the upper surface of the SC, away from the cover glass, is labeled. This is where the SC was directly exposed to the label. In contrast, the SC facing the glass (lower part in the z direction) is unlabeled. This is likely due to barrier properties of the SC towards the dye. In contrast, the SG and SS/SB are labeled all the way through in the z direction. Scale bars are 5 μm.
Fig 2 Cryo frozen and sectioned skin labelled with the free dye, Atto-488-DPPE, in PBS buffer. A) A STED image of the sample in which the SC is clearly visible, as the bright u-shaped layer in the center of the image; the width of the lipid layers in the SC are measured to approximately 100–120 nm. A line scan across the marked line is shown in B, and the individual lipid layers are recognizable. C) A confocal cross section (XZ plane) through a skin section. The slice is orientated with the SC to the left. Only the upper surface of the SC, away from the cover glass, is labeled. This is where the SC was directly exposed to the label. In contrast, the SC facing the glass (lower part in the z direction) is unlabeled. This is likely due to barrier properties of the SC towards the dye. In contrast, the SG and SS/SB are labeled all the way through in the z direction. Scale bars are 5 μm.CC BY · PubMed Central
Fig 3 Image of the surface of intact skin. The skin samples were labeled using LUVs with Atto-488-DPPE. After labeling for 6–8 hours the samples were rinsed and patted dry, removing most of the LUVs from the surface. An intense labeling of the lipids around the corneocytes is observed. A) and B) shows a STED and confocal image, respectively, of a large area where several corneocytes can be distinguished. C) and D) are enlargements of the mark regions in A and B. The resolution difference between confocal and STED can clearly be seen. E) shows an intensity line profile across the line marked in C (blue) and D (green), again it is evident that STED reveals details not resolved in the confocal image. Both the STED and confocal image have been deconvolved. Scale bars are 5 μm for A and B, and 1 μm for C and D.
Fig 3 Image of the surface of intact skin. The skin samples were labeled using LUVs with Atto-488-DPPE. After labeling for 6–8 hours the samples were rinsed and patted dry, removing most of the LUVs from the surface. An intense labeling of the lipids around the corneocytes is observed. A) and B) shows a STED and confocal image, respectively, of a large area where several corneocytes can be distinguished. C) and D) are enlargements of the mark regions in A and B. The resolution difference between confocal and STED can clearly be seen. E) shows an intensity line profile across the line marked in C (blue) and D (green), again it is evident that STED reveals details not resolved in the confocal image. Both the STED and confocal image have been deconvolved. Scale bars are 5 μm for A and B, and 1 μm for C and D.CC BY · PubMed Central
Fig 4 STED images of FLUVs on intact skin. Several vesicles are visible on the surface (A) and at different depths of the skin (B-D). FLUVs are not observed deeper in the skin. In the lower layers, C and D, the FLUVs are generally located at the edge of the corneocytes. Scale bars are 5 μm.
Fig 4 STED images of FLUVs on intact skin. Several vesicles are visible on the surface (A) and at different depths of the skin (B-D). FLUVs are not observed deeper in the skin. In the lower layers, C and D, the FLUVs are generally located at the edge of the corneocytes. Scale bars are 5 μm.CC BY · PubMed Central
Fig 5 Cryoembedded and -sectioned skin exposed to POPC LUVs on the skin surface prior to processing for microscopy. Several LUVs can be seen on the surface of the SC, e.g. magnified region of interest in A. Some penetration of the dye into the superficial SC layers can be seen in B and C, where the underlying layers of the SC have become labeled by the dye included in the LUVs. LUVs are rarely found inside the SC. Scale bars are 2 μm.
Fig 5 Cryoembedded and -sectioned skin exposed to POPC LUVs on the skin surface prior to processing for microscopy. Several LUVs can be seen on the surface of the SC, e.g. magnified region of interest in A. Some penetration of the dye into the superficial SC layers can be seen in B and C, where the underlying layers of the SC have become labeled by the dye included in the LUVs. LUVs are rarely found inside the SC. Scale bars are 2 μm.CC BY · PubMed Central
Fig 6 Cryoembedded and -sectioned skin exposed to FLUVs on the skin surface prior to processing for imaging. Intact FLUVs were rarely found on the surface, and the SC was generally more intensely labeled by the dye from the FLUVs than from the LUVs, indicating a better penetration of the dye from the FLUVs. Sometimes the dye was observed deeply into the SC panel B) whereas in other cases the staining was more confined to the upper most layers of SC (panel A). Scale bars are 5 μm.
Fig 6 Cryoembedded and -sectioned skin exposed to FLUVs on the skin surface prior to processing for imaging. Intact FLUVs were rarely found on the surface, and the SC was generally more intensely labeled by the dye from the FLUVs than from the LUVs, indicating a better penetration of the dye from the FLUVs. Sometimes the dye was observed deeply into the SC panel B) whereas in other cases the staining was more confined to the upper most layers of SC (panel A). Scale bars are 5 μm.CC BY · PubMed Central
Fig 7 RICS data. The panels show the CC-RICS data (upper graph) and the fit (lower graph), for RhB-PE and ATTO-647N-PE labeled LUVs (panels A-C) and FLUVs (panels D-F) together with an intensity image of the ATTO-647N-PE channel. A) CC-RICS and fit for LUVs at the SC surface. A clear cross correlation is seen. B and C are CC-RICS and fit for LUVs at 4μm below the SC surface. In 15% of the measurements a cross correlation was found (panel B) while most of the measurements showed no cross correlation (panel C). D) CC-RICS and fit for FLUVs at the SC surface. A clear cross correlation is seen. E and F are CC-RICS and fit for FLUVs at 4μm below the SC surface. In 9% of the measurements a cross correlation was found (panel E) while most of the measurements showed no cross correlation (panel F). The image sizes are 22 x 22μm2.
Fig 7 RICS data. The panels show the CC-RICS data (upper graph) and the fit (lower graph), for RhB-PE and ATTO-647N-PE labeled LUVs (panels A-C) and FLUVs (panels D-F) together with an intensity image of the ATTO-647N-PE channel. A) CC-RICS and fit for LUVs at the SC surface. A clear cross correlation is seen. B and C are CC-RICS and fit for LUVs at 4μm below the SC surface. In 15% of the measurements a cross correlation was found (panel B) while most of the measurements showed no cross correlation (panel C). D) CC-RICS and fit for FLUVs at the SC surface. A clear cross correlation is seen. E and F are CC-RICS and fit for FLUVs at 4μm below the SC surface. In 9% of the measurements a cross correlation was found (panel E) while most of the measurements showed no cross correlation (panel F). The image sizes are 22 x 22μm2.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

Metadata

Authors
Dreier, J., Sørensen, J. A., & Brewer, J. R.
Affiliations
  • University of Southern Denmark (DK)
  • Odense University Hospital (DK)
Corresponding author
Brewer, Jonathan R.
Venue
PLOS ONE
Published
2016-01-11
Volume
11
Issue
1
Pages
e0146514
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2239631636
Cited by
57
References
42
Citations by year
2026: 4 · 2025: 2 · 2024: 2 · 2023: 6 · 2022: 7 · 2021: 14 · 2020: 2 · 2019: 7 · 2018: 2 · 2017: 5 · 2016: 6
FWCI
3.80
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • University of Southern Denmark Research Portal (University of Southern Denmark) (acceptedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Funders
Villum Fonden (00007268)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Lipid Membrane Structure and Behavior
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
Keywords
liposomes, transdermal drug delivery, stratum corneum, liposome fusion, POPC liposomes, sodium cholate, chemical permeation enhancers, fluorescent liposomes, skin permeability
MeSH terms
Administration, Cutaneous, Diffusion, Drug Carriers, Fluorescence, Fluorescent Dyes, Humans, Liposomes, Microscopy, Fluorescence, Permeability, Phosphatidylcholines, Skin, Skin Absorption, Microscopy, Confocal, Cryoelectron Microscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.